Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Eur J Radiol ; 150: 110116, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34996651

RESUMO

Positron emission tomography/computed tomography (PET/CT) with 18F-fluorodeoxyglucose (18F-FDG) has become the method of choice for tumor staging in lung cancer patients with improved diagnostic accuracy for the evaluation of lymph node involvement and distant metastasis. Due to its spectral capabilities, dual-energy CT (DECT) employs a material decomposition algorithm enabling precise quantification of iodine concentrations in distinct tissues. This technique enhances the characterization of tumor blood supply and has demonstrated promising results for the assessment of therapy response in patients with lung cancer. Several studies have demonstrated that DECT provides additional value to the PET-based evaluation of glycolytic activity, especially for the evaluation of therapy response and follow-up of patients with lung cancer. The combination of PET and DECT in a single scanner system enables the simultaneous assessment of glycolytic activity and iodine enhancement, offering further insight to the characterization of tumorous tissues. Recently a new approach of a novel integrated PET/DECT was investigated in a pilot study on patients with non-small cell lung cancer (NSCLC). The study showed a moderate correlation between PET-based standard uptake values (SUV) and DECT-based iodine densities in the evaluation of lung tumorous tissue but with limited assessment of lymph nodes. The following review on tumorous tissue characterization using PET and DECT imaging describes the strengths and limitations of this novel technique.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Iodo , Neoplasias Pulmonares , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Estadiamento de Neoplasias , Projetos Piloto , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X/métodos
3.
J Thorac Imaging ; 37(6): W72-W77, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34534998

RESUMO

PURPOSE: The purpose of this study was to compare image quality and coronary interpretability of triple-rule-out systolic and diastolic protocols in patients with acute chest pain. MATERIALS AND METHODS: From March 2016 to October 2017 the authors prospectively enrolled patients with undifferentiated acute chest pain, who were at low to intermediate cardiovascular risk. Those with heart rate >75 bpm underwent a systolic prospectively triggered acquisition (systolic triggering [ST]), and in those with ≤75 bpm, end-diastolic triggering (DT) was instead performed. Examinations were evaluated for coronary artery disease, aortic dissection, and pulmonary embolism. Image quality was assessed using a Likert scale. Coronary arteries interpretability was evaluated both on a per-vessel and a per segment basis. The occurrence of major adverse cardiovascular events was investigated. RESULTS: The final study population was 189 patients. Fifty-two patients (27.5%) underwent systolic acquisition and 137 (72.5%) underwent diastolic acquisition. No significant differences in overall image quality were observed between DT and ST groups (median score 5 [interquartile ranges 4 to 5] vs. 4 [interquartile ranges 4 to 5], P =0.074). Although both DT and ST protocols showed low percentages of noninterpretable coronary arteries on a per-vessel (1.5% and 6.7%, respectively) and per-segment analysis (1% and 4.7%, respectively), these percentages resulted significantly higher for ST groups ( P <0.001). Obstructive coronary stenosis was observed in 18 patients. Only one case of pulmonary embolism was diagnosed and no cases of aortic dissection were found in our population. No death or major adverse cardiovascular events were observed during follow-up among the 2 groups. CONCLUSIONS: Results showed that triple-rule-out computed tomography angiography is a reliable technique in patients with acute chest pain and that an ST acquisition protocol could be considered an alternative acquisition protocol in patients with higher heart rate, reaching a good image quality.


Assuntos
Dissecção Aórtica , Estenose Coronária , Embolia Pulmonar , Humanos , Doses de Radiação , Dor no Peito/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Eletrocardiografia/métodos , Angiografia Coronária/métodos
4.
Acta Radiol ; 63(12): 1619-1626, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34779269

RESUMO

BACKGROUND: Chest radiography (CR) patterns for the diagnosis of COVID-19 have been established. However, they were not ideated comparing CR features with those of other pulmonary diseases. PURPOSE: To create the most accurate COVID-19 pneumonia pattern comparing CR findings of COVID-19 and non-COVID-19 pulmonary diseases and to test the model against the British Society of Thoracic Imaging (BSTI) criteria. MATERIAL AND METHODS: CR of COVID-19 and non-COVID-19 pulmonary diseases, admitted to the emergency department, were evaluated. Assessed features were interstitial opacities, ground glass opacities, and/or consolidations and the predominant lung alteration. We also assessed uni-/bilaterality, location (upper/middle/lower), and distribution (peripheral/perihilar), as well as pleural effusion and perihilar vessels blurring. A binary logistic regression was adopted to obtain the most accurate CR COVID-19 pattern, and sensitivity and specificity were computed. The newly defined pattern was compared to BSTI criteria. RESULTS: CR of 274 patients were evaluated (146 COVID-19, 128 non-COVID-19). The most accurate COVID-19 pneumonia pattern consisted of four features: bilateral alterations (Expß=2.8, P=0.002), peripheral distribution of the predominant (Expß=2.3, P=0.013), no pleural effusion (Expß=0.4, P=0.009), and perihilar vessels' contour not blurred (Expß=0.3, P=0.002). The pattern showed 49% sensitivity, 81% specificity, and 64% accuracy, while BSTI criteria showed 51%, 77%, and 63%, respectively. CONCLUSION: Bilaterality, peripheral distribution of the predominant lung alteration, no pleural effusion, and perihilar vessels contour not blurred determine the most accurate COVID-19 pneumonia pattern. Lower field involvement, proposed by BSTI criteria, was not a distinctive finding. The BSTI criteria has lower specificity.


Assuntos
COVID-19 , Derrame Pleural , Humanos , COVID-19/diagnóstico por imagem , SARS-CoV-2 , Diagnóstico Diferencial , Tomografia Computadorizada por Raios X/métodos , Radiografia , Pulmão/diagnóstico por imagem , Radiografia Torácica/métodos , Estudos Retrospectivos
5.
Heart Fail Clin ; 17(2): 187-194, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33673944

RESUMO

During the past decade, coronary computed tomography angiography has emerged as the primary modality to noninvasively detect and rule out coronary artery disease. Therefore, this technique could play an important role in identifying patients at high risk of heart failure, considering the high prevalence of coronary artery disease in these patients. The latest technologies have also increased diagnostic accuracy, helping to close the gap with the other functional imaging modalities.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/complicações , Insuficiência Cardíaca/prevenção & controle , Tomografia Computadorizada por Raios X/métodos , Doença da Artéria Coronariana/diagnóstico , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Humanos , Valor Preditivo dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...