1.
Phys Imaging Radiat Oncol ; 31: 100612, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39161728

RESUMO

Background and purpose: Magnetic resonance imaging (MRI)-to-computed tomography (CT) synthesis is essential in MRI-only radiotherapy workflows, particularly through deep learning techniques known for their accuracy. However, current supervised methods are limited to specific center's learnings and depend on registration precision. The aim of this study was to evaluate the accuracy of unsupervised and supervised approaches in the context of prostate MRI-to-CT generation for radiotherapy dose calculation. Methods: CT/MRI image pairs from 99 prostate cancer patients across three different centers were used. A comparison between supervised and unsupervised conditional Generative Adversarial Networks (cGAN) was conducted. Unsupervised training incorporates a style transfer method with. Content and Style Representation for Enhanced Perceptual synthesis (CREPs) loss. For dose evaluation, the photon prescription dose was 60 Gy delivered in volumetric modulated arc therapy (VMAT). Imaging endpoint for sCT evaluation was Mean Absolute Error (MAE). Dosimetric endpoints included absolute dose differences and gamma analysis between CT and sCT dose calculations. Results: The unsupervised paired network exhibited the highest accuracy for the body with a MAE at 33.6 HU, the highest MAE was 45.5 HU obtained with unsupervised unpaired learning. All architectures provided clinically acceptable results for dose calculation with gamma pass rates above 94 % (1 % 1 mm 10 %). Conclusions: This study shows that multicenter data can produce accurate sCTs via unsupervised learning, eliminating CT-MRI registration. The sCTs not only matched HU values but also enabled precise dose calculations, suggesting their potential for wider use in MRI-only radiotherapy workflows.

2.
Phys Imaging Radiat Oncol ; 28: 100511, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38077271

RESUMO

Background and Purpose: Addressing the need for accurate dose calculation in MRI-only radiotherapy, the generation of synthetic Computed Tomography (sCT) from MRI has emerged. Deep learning (DL) techniques, have shown promising results in achieving high sCT accuracies. However, existing sCT synthesis methods are often center-specific, posing a challenge to their generalizability. To overcome this limitation, recent studies have proposed approaches, such as multicenter training . Material and methods: The purpose of this work was to propose a multicenter sCT synthesis by DL, using a 2D cycle-GAN on 128 prostate cancer patients, from four different centers. Four cases were compared: monocenter cases, monocenter training and test on another center, multicenter trainings and a test on a center not included in the training and multicenter trainings with an included center in the test. Trainings were performed using 20 patients. sCT accuracy evaluation was performed using Mean Absolute Error, Mean Error and Peak-Signal-to-Noise-Ratio. Dose accuracy was assessed with gamma index and Dose Volume Histogram comparison. Results: Qualitative, quantitative and dose results show that the accuracy of sCTs for monocenter trainings and multicenter trainings using a seen center in the test did not differ significantly. However, when the test involved an unseen center, the sCT quality was inferior. Conclusions: The aim of this work was to propose generalizable multicenter training for MR-to-CT synthesis. It was shown that only a few data from one center included in the training cohort allows sCT accuracy equivalent to a monocenter study.

3.
Front Oncol ; 13: 1279750, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38090490

RESUMO

Introduction: For radiotherapy based solely on magnetic resonance imaging (MRI), generating synthetic computed tomography scans (sCT) from MRI is essential for dose calculation. The use of deep learning (DL) methods to generate sCT from MRI has shown encouraging results if the MRI images used for training the deep learning network and the MRI images for sCT generation come from the same MRI device. The objective of this study was to create and evaluate a generic DL model capable of generating sCTs from various MRI devices for prostate radiotherapy. Materials and methods: In total, 90 patients from three centers (30 CT-MR prostate pairs/center) underwent treatment using volumetric modulated arc therapy for prostate cancer (PCa) (60 Gy in 20 fractions). T2 MRI images were acquired in addition to computed tomography (CT) images for treatment planning. The DL model was a 2D supervised conditional generative adversarial network (Pix2Pix). Patient images underwent preprocessing steps, including nonrigid registration. Seven different supervised models were trained, incorporating patients from one, two, or three centers. Each model was trained on 24 CT-MR prostate pairs. A generic model was trained using patients from all three centers. To compare sCT and CT, the mean absolute error in Hounsfield units was calculated for the entire pelvis, prostate, bladder, rectum, and bones. For dose analysis, mean dose differences of D 99% for CTV, V 95% for PTV, Dmax for rectum and bladder, and 3D gamma analysis (local, 1%/1 mm) were calculated from CT and sCT. Furthermore, Wilcoxon tests were performed to compare the image and dose results obtained with the generic model to those with the other trained models. Results: Considering the image results for the entire pelvis, when the data used for the test comes from the same center as the data used for training, the results were not significantly different from the generic model. Absolute dose differences were less than 1 Gy for the CTV D 99% for every trained model and center. The gamma analysis results showed nonsignificant differences between the generic and monocentric models. Conclusion: The accuracy of sCT, in terms of image and dose, is equivalent to whether MRI images are generated using the generic model or the monocentric model. The generic model, using only eight MRI-CT pairs per center, offers robust sCT generation, facilitating PCa MRI-only radiotherapy for routine clinical use.