Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
mSphere ; 4(3)2019 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-31217308

RESUMO

In 2011, the human pneumococcal standard reference serum, 007sp, was established as a replacement for the previous standard, lot 89SF, supplies of which were dwindling. The pneumococcal reference serum is used primarily in the standardized pneumococcal enzyme-linked immunosorbent assay (World Health Organization reference enzyme-linked immunosorbent assay) but has also been used in functional assays. Serotype-specific IgG values for 24 pneumococcal capsular serotypes have previously been assigned to 007sp by bridging to the original values derived for lot 89SF. In this study, by bridging to existing values in lot 89SF, we assign weight-based serotype-specific IgA, IgG1, and IgG2 to 007sp for 11 pneumococcal capsular serotypes (1, 3, 4, 5, 6B, 7F, 9V, 14, 18C, 19F, and 23F), as well as serotype 19A-specific IgA. Concentrations for serotype-specific IgA, IgG1, and IgG2 present in 007sp were comparable to those previously assigned to lot 89SF. In addition, the concentration of serotype-specific IgG1 plus IgG2 assigned to 007sp significantly correlated to previously assigned 007sp IgG values. The accuracy of antibody assignments to 007sp from lot 89SF was assessed by comparing the concentration of serotype-specific IgA, IgG1, and IgG2 in 16 unknown samples using both 007sp and lot 89SF as the standard. Interpolated values for the unknown samples were highly correlated with average R2 values of 0.9729, 0.9951, and 0.9933 for IgA, IgG1, and IgG2, respectively, for all serotypes demonstrating the precise nature assignments to 007sp made in this study. Nonparallelism between 007sp and lot 89SF has precluded the derivation of serotype-specific IgM values.IMPORTANCE A well-characterized antibody standard is an indispensable reagent for use in assays designed to measure antibodies with precision and where assays between laboratories need to be comparable. The human pneumococcal standard reference serum, lot 89SF, greatly facilitated the standardization of enzyme-linked immunosorbent assay methodologies during a critical period when the first pneumococcal polysaccharide-conjugate vaccines were being evaluated for licensure. Due to dwindling supplies of lot 89SF, a new reference standard, 007sp, was produced in 2011. Understanding the isotype and subclass composition of either natural or vaccine induced responses to pathogens has assumed increasing importance. In this study, we have assigned IgA, IgG1, and IgG2 values to pneumococcal serotypes 1, 3, 4, 5, 6B, 7F, 9V, 14, 18C, 19A, 19F, and 23F by bridging to existing values in lot 89SF.


Assuntos
Cápsulas Bacterianas/imunologia , Imunoglobulina A/classificação , Imunoglobulina G/classificação , Sorogrupo , Soro , Anticorpos Antibacterianos , Ensaio de Imunoadsorção Enzimática/normas , Humanos , Peso Molecular , Padrões de Referência , Streptococcus pneumoniae/imunologia
2.
Clin Infect Dis ; 61(11): 1637-44, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26374816

RESUMO

INTRODUCTION: In England, antenatal pertussis immunization using a tetanus/low-dose diphtheria/5-component acellular-pertussis/inactivated-polio (TdaP5/IPV) vaccine was introduced in October 2012. We assessed infant responses to antigens in the maternal vaccine and to those conjugated to tetanus (TT) or the diphtheria toxin variant, CRM. METHODS: Infants of 141 TdaP5/IPV-vaccinated mothers in Southern England immunized with DTaP5/IPV/Haemophilus influenzae b (Hib-TT) vaccine at 2-3-4 months, 13-valent pneumococcal vaccine (PCV13, CRM-conjugated) at 2-4 months and 1 or 2 meningococcal C vaccine (MCC-CRM- or MCC-TT) doses at 3-4 months had blood samples taken at 2 and/or 5 months of age. RESULTS: Antibody responses to pertussis toxin (PT), filamentous hemagglutinin (FHA), fimbriae 2 + 3 (FIMs), diphtheria, tetanus, Hib, MCC and PCV13 serotypes were compared to responses in a historical cohort of 246 infants born to mothers not vaccinated in pregnancy. Infants had high pertussis antibody concentrations pre-immunization but only PT antibodies increased post-immunization (fold-change, 2.64; 95% confidence interval [CI], 2.12-3.30; P < .001), whereas FHA antibodies fell (fold-change, 0.56; 95% CI, .48-.65; P < .001). Compared with infants of unvaccinated mothers, PT, FHA, and FIMs antibodies were lower post-vaccination, with fold-differences of 0.67 (0.58-0.77; P < .001), 0.62 (0.54-0.71; P < .001) and 0.51 (0.42-0.62; P < .001), respectively. Antibodies to diphtheria and some CRM-conjugated antigens were also lower, although most infants achieved protective thresholds; antibodies to tetanus and Hib were higher. CONCLUSIONS: Antenatal pertussis immunization results in high infant pre-immunization antibody concentrations, but blunts subsequent responses to pertussis vaccine and some CRM-conjugated antigens. In countries with no pertussis booster until school age, continued monitoring of protection against pertussis is essential.


Assuntos
Anticorpos Antibacterianos/sangue , Bordetella pertussis/imunologia , Vacinas contra Difteria, Tétano e Coqueluche Acelular/imunologia , Imunidade Materno-Adquirida , Coqueluche/imunologia , Antígenos de Bactérias/imunologia , Estudos de Coortes , Vacinas contra Difteria, Tétano e Coqueluche Acelular/administração & dosagem , Inglaterra , Feminino , Vacinas Anti-Haemophilus/administração & dosagem , Vacinas Anti-Haemophilus/imunologia , Humanos , Imunização Secundária , Imunoglobulina G/sangue , Lactente , Masculino , Vacinas Meningocócicas/administração & dosagem , Vacinas Pneumocócicas/administração & dosagem , Vacinas Pneumocócicas/imunologia , Vacina Antipólio de Vírus Inativado/administração & dosagem , Gravidez , Toxoide Tetânico/administração & dosagem , Toxoide Tetânico/imunologia , Vacinas Conjugadas/administração & dosagem , Vacinas Conjugadas/imunologia , Coqueluche/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA