Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Cureus ; 10(5): e2713, 2018 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-30079279

RESUMO

Background Non-resected locally advanced and microscopic positive-margin resected (R1) pancreatic adenocarcinoma are associated with a dismal prognosis. The combination of high dose radiotherapy and concomitant chemotherapy is among the strategies that are used to improve the outcome. The aims of this study were to evaluate the acute and late toxicities and patients' outcome in a retrospective study from a single center. Material and methods From 2009 to 2015, 24 patients, with non-resected locally advanced or R1 resected pancreatic adenocarcinoma, have been treated with concomitant radiochemotherapy, with a median dose of 60 Gy and gemcitabine (50 mg/m2 administered bi-weekly). The acute and late toxicities were evaluated during and after the treatment. Results The actuarial overall survival rates were 39% at 24 months and 8.6% at 36 months. The disease-free survival rates were 32.5% at 24 months and 12.2% at 36 months. Acute toxicities were mainly grade 1 (G1) to grade 2 (G2) except for one patient who presented with severe digestive bleeding potentially linked to the treatment. Late toxicities consisted mainly of G1 digestive toxicities. Conclusion This study confirms the feasibility of high dose radiotherapy combined with gemcitabine-based chemotherapy in patients with locally advanced pancreatic adenocarcinoma. While the outcome remains unsatisfactory, some patients seem to have benefited from this aggressive therapy, which merits to be investigated further.

3.
Radiother Oncol ; 79(1): 101-8, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16621076

RESUMO

BACKGROUND AND PURPOSE: Daily use of conventional electronic portal imaging devices (EPID) for organ tracking is limited due to the relatively high dose required for high quality image acquisition. We studied the use of a novel dose saving acquisition mode (RadMode) allowing to take images with one monitor unit per image in prostate cancer patients undergoing intensity-modulated radiotherapy (IMRT) and tracking of implanted fiducial gold markers. PATIENTS AND METHODS: Twenty five patients underwent implantation of three fiducial gold markers prior to the planning CT. Before each treatment of a course of 37 fractions, orthogonal localization images from the antero-posterior and from the lateral direction were acquired. Portal images of both the setup procedure and the five IMRT treatment beams were analyzed. RESULTS: On average, four localization images were needed for a correct patient setup, resulting in four monitor units extra dose per fraction. The mean extra dose delivered to the patient was thereby increased by 1.2%. The procedure was precise enough to reduce the mean displacements prior to treatment to < o =0.3 mm. CONCLUSIONS: The use of a new dose saving acquisition mode enables to perform daily EPID-based prostate tracking with a cumulative extra dose of below 1 Gy. This concept is efficiently used in IMRT-treated patients, where separation of setup beams from treatment beams is mandatory.


Assuntos
Eletrônica Médica/instrumentação , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia de Intensidade Modulada , Ouro , Humanos , Masculino , Próstata/efeitos da radiação , Neoplasias da Próstata/diagnóstico por imagem , Radiografia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...