Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Front Endocrinol (Lausanne) ; 14: 1236881, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37780613

RESUMO

We review the rationale, methodology, and clinical utility of quantitative [18F] sodium fluoride ([18F]NaF) positron emission tomography-computed tomography (PET-CT) imaging to measure bone metabolic flux (Ki, also known as bone plasma clearance), a measurement indicative of the local rate of bone formation at the chosen region of interest. We review the bone remodelling cycle and explain what aspects of bone remodelling are addressed by [18F]NaF PET-CT. We explain how the technique works, what measurements are involved, and what makes [18F]NaF PET-CT a useful tool for the study of bone remodelling. We discuss how these measurements can be simplified without loss of accuracy to make the technique more accessible. Finally, we briefly review some key clinical applications and discuss the potential for future developments. We hope that the simplified method described here will assist in promoting the wider use of the technique.


Assuntos
Neoplasias Ósseas , Fluoreto de Sódio , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Osso e Ossos/diagnóstico por imagem
2.
BMC Nephrol ; 23(1): 379, 2022 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-36443713

RESUMO

BACKGROUND: Changes in renal perfusion may play a pathophysiological role in hypertension and kidney disease, however to date, no method for renal blood flow (RBF) determination in humans has been implemented in clinical practice. In a previous study, we demonstrated that estimation of renal perfusion based on a single positron emission tomography/computed tomography (PET/CT) scan with Rubidium-82 (82Rb) is feasible and found an approximate 5% intra-assay coefficient of variation for both kidneys, indicative of a precise method.This study's aim was to determine the day-to day variation of 82Rb PET/CT and to test the method's ability to detect increased RBF induced by infusion of amino acids. METHODS: Seventeen healthy subjects underwent three dynamic 82Rb PET/CT scans over two examination days comprising: Day A, a single 8-minute dynamic scan and Day B, two scans performed before (baseline) and after RBF stimulation by a 2-hour amino acid-infusion. The order of examination days was determined by randomization. Time activity curves for arterial and renal activity with a 1-tissue compartment model were used for flow estimation; the K1 kinetic parameter representing renal 82Rb clearance. Day-to-day variation was calculated based on the difference between the unstimulated K1 values on Day A and Day B and paired t-testing was performed to compare K1 values at baseline and after RBF stimulation on Day B. RESULTS: Day-to-day variation was observed to be 5.5% for the right kidney and 6.0% for the left kidney (n = 15 quality accepted scans). K1 values determined after amino acid-infusion were significantly higher than pre-infusion values (n = 17, p = 0.001). The mean percentage change in K1 from baseline was 13.2 ± 12.9% (range - 10.4 to 35.5) for the right kidney; 12.9 ± 13.2% (range - 15.7 to 35.3) for the left kidney. CONCLUSION: Day-to-day variation is acceptably low. A significant K1 increase from baseline is detected after application of a known RBF stimulus, indicating that 82Rb PET/CT scanning can provide a precise method for evaluation of RBF and it is able to determine changes herein. CLINICAL TRIAL REGISTRATION: EU Clinical Trials Register, 2017-005008-88. Registered 18/01/2018.


Assuntos
Rim , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Aminoácidos , Voluntários Saudáveis , Rim/diagnóstico por imagem , Perfusão , Reprodutibilidade dos Testes
3.
Am J Nephrol ; 53(6): 490-502, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35671711

RESUMO

INTRODUCTION: Invasive bone biopsy to assess bone metabolism in patients with chronic kidney disease-mineral and bone disorder may be replaced by the noninvasive 18F-NaF PET/CT and biomarkers of bone metabolism. We aimed to compare parameters of bone turnover, mineralization, and volume assessed by bone biopsies with results derived from 18F-NaF PET/CT and biomarkers (bone-specific alkaline phosphatase, osteocalcin, fibroblast growth factor 23, and osteoprotegerin). METHODS: A cross-sectional study included 17 dialysis patients, and results from 18F-NaF PET/CT scans and the biomarkers were directly compared with the results of histomorphometric analyses of tetracycline double-labeled trans-iliac bone biopsies. RESULTS: Bone biopsies showed 40% high, 20% normal, and 40% low bone turnover. No biopsies had generalized abnormal mineralization, and the bone volume/total tissue volume was low in 80% and high in 7%. The pelvic skeletal plasma clearance (Ki) from 18F-NaF PET/CT correlated with bone turnover parameters obtained by bone biopsy (activation frequency: r = 0.82, p < 0.01; bone formation rate/bone surface: r = 0.81, p < 0.01), and Ki defined low turnover with high sensitivity (83%) and specificity (100%). CT-derived radiodensity correlated with bone volume, r = 0.82, p < 0.01. Of the biomarkers, only osteocalcin showed a correlation with turnover assessed by histomorphometry. CONCLUSION: In conclusion, 18F-NaF PET/CT may be applicable for noninvasive assessment of bone turnover and volume in CKD-MBD.


Assuntos
Distúrbio Mineral e Ósseo na Doença Renal Crônica , Insuficiência Renal Crônica , Biomarcadores , Biópsia , Remodelação Óssea/fisiologia , Distúrbio Mineral e Ósseo na Doença Renal Crônica/diagnóstico por imagem , Distúrbio Mineral e Ósseo na Doença Renal Crônica/etiologia , Estudos Transversais , Radioisótopos de Flúor , Humanos , Minerais/metabolismo , Osteocalcina , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Sódio/metabolismo , Fluoreto de Sódio/metabolismo
4.
Clin Physiol Funct Imaging ; 41(6): 488-496, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34418886

RESUMO

BACKGROUND: Accurate, precise and straightforward methods for measuring glomerular filtration rate (GFR) and/or renal plasma flow (RPF) are still in demand today. The time-consuming constant infusion technique (CIT) is the gold standard and preferred for research, whereas the simple, but less precise, single injection technique (SIT) is used in clinical settings. This study investigated the use of 99m Tc-DTPA and 99m Tc-MAG3 by CIT as a measure of renal function. We developed and evaluated a model to balance the primer dose and infusion rate in an attempt to obtain plasma steady state as quickly as possible. METHODS: 14 healthy subjects received 99m Tc-DTPA and 6 hypertensive patients received 99m Tc-MAG3 in a standardized protocol. All participants had an eGFR above 60 ml/min and none had fluid retention. An intravenous primer injection of the relevant tracer was followed by a sustained infusion over 4.5 h with the same radiopharmaceutical. Blood and urine samples were collected at fixed intervals. RESULTS: 99m Tc-DTPA clearance reached steady state after 210 min (plasma clearance 78 ± 18 ml/min, urine clearance 110 ± 28 ml/min), whereas 99m Tc-MAG3  clearance achieved steady state after 150 min (plasma clearance 212 ± 56 ml/min, urine clearance 233 ± 59 ml/min). CONCLUSION: Constant infusion technique with fixed primer and infusion rate using 99m Tc-MAG3 is feasible for research purposes. The longer time for reaching plasma steady state using 99m Tc-DTPA makes CIT with this tracer less optimal. If the primer/sustained balance can be optimized, for example using a priori SIT information, 99m Tc-DTPA as tracer for CIT may also be feasible.


Assuntos
Tecnécio Tc 99m Mertiatida , Pentetato de Tecnécio Tc 99m , Taxa de Filtração Glomerular , Humanos , Testes de Função Renal , Tecnécio
5.
EJNMMI Phys ; 8(1): 43, 2021 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-34057645

RESUMO

BACKGROUND: Changes in renal blood flow (RBF) may play a pathophysiological role in hypertension and kidney disease. However, RBF determination in humans has proven difficult. We aimed to confirm the feasibility of RBF estimation based on positron emission tomography/computed tomography (PET/CT) and rubidium-82 (82Rb) using the abdominal aorta as input function in a 1-tissue compartment model. METHODS: Eighteen healthy subjects underwent two dynamic 82Rb PET/CT scans in two different fields of view (FOV). FOV-A included the left ventricular blood pool (LVBP), the abdominal aorta (AA) and the majority of the kidneys. FOV-B included AA and the kidneys in their entirety. In FOV-A, an input function was derived from LVBP and from AA, in FOV-B from AA. One-tissue compartmental modelling was performed using tissue time activity curves generated from volumes of interest (VOI) contouring the kidneys, where the renal clearance of 82Rb is represented by the K1 kinetic parameter. Total clearance for both kidneys was calculated by multiplying the K1 values with the volume of VOIs used for analysis. Intra-assay coefficients of variation and inter-observer variation were calculated. RESULTS: For both kidneys, K1 values derived from AA did not differ significantly from values obtained from LVBP, neither were significant differences seen between AA in FOV-A and AA in FOV-B, nor between the right and left kidneys. For both kidneys, the intra-assay coefficients of variation were low (~ 5%) for both input functions. The measured K1 of 2.80 ml/min/cm3 translates to a total clearance for both kidneys of 766 ml/min/1.73 m2. CONCLUSION: Measurement of renal perfusion based on PET/CT and 82Rb using AA as input function in a 1-tissue compartment model is feasible in a single FOV. Based on previous studies showing 82Rb to be primarily present in plasma, the measured K1 clearance values are most likely representative of effective renal plasma flow (ERPF) rather than estimated RBF values, but as the accurate calculation of total clearance/flow is very much dependent on the analysed volume, a standardised definition for the employed renal volumes is needed to allow for proper comparison with standard ERPF and RBF reference methods.

6.
Nucl Med Commun ; 34(2): 155-61, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23196674

RESUMO

OBJECTIVE: The aim of this study was to investigate the feasibility of F-fluoroazomycinarabinofuranoside (F-FAZA) positron emission tomography (PET)/computed tomography (CT) in patients with locally advanced rectal cancer. MATERIALS AND METHODS: The study included 14 patients with locally advanced rectal cancer. Before chemoradiotherapy, PET/CT with F-FAZA was performed with static 15 min images 2 h after injection of F-FAZA. Attenuation correction was obtained with a low-dose CT, and a contrast-enhanced CT was performed immediately after the PET scan. RESULTS: F-FAZA uptake [mean and maximum standardized uptake value (SUVmean) and (SUVmax)] was significantly higher in rectal tumours than in both muscles (P<0.003) and normal intestinal walls (P<5×10). The tumour to muscle (T/M) ratios ranged from 1.19 to 3.05 with a mean of 1.97, whereas the tumour to intestinal wall (T/I) ratios had values of 1.73-5.81 with a mean of 2.83. Intense activity accumulating in the bladder produced obvious scattered activity, which spread into the surrounding tissue. Tumour volumes excluding scatter were therefore determined, in which the SUVmax and SUVmean were also significantly higher than in both muscles (P<0.004) and normal intestinal walls (P<2×10) and had T/M ratios of 1.19-2.72 with a mean of 1.85 and T/I ratios of 1.71-5.40 with a mean of 2.67. The individual SUVmax, SUVmean, T/M and T/I values were significantly higher in the entire tumour volume compared with the tumour volume adjusted for scatter from the urinary bladder (P<0.005), although the absolute differences were small. CONCLUSION: F-FAZA PET/CT is feasible for visualization of hypoxia in patients with rectal cancer, but scattered activity from the urinary bladder should be taken into consideration.


Assuntos
Imagem Multimodal , Nitroimidazóis , Tomografia por Emissão de Pósitrons , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/patologia , Tomografia Computadorizada por Raios X , Idoso , Transporte Biológico , Hipóxia Celular , Estudos de Viabilidade , Feminino , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Nitroimidazóis/metabolismo , Neoplasias Retais/metabolismo , Carga Tumoral , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/metabolismo
7.
Radiother Oncol ; 105(1): 14-20, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23083497

RESUMO

PURPOSE: Hypoxia is a cause of resistance to radiotherapy, especially in patients with head and neck squamous cell carcinoma (HNSCC). The purpose of this study was to evaluate (18)F-fluoroazomycin arabinoside (FAZA) positron emission tomography (PET)/computed tomography (CT) hypoxia imaging as a prognostic factor in HNSCC patients receiving radiotherapy. MATERIAL AND METHODS: Forty patients with HNSCC treated with radiotherapy (66-76 Gy) were included. Static FAZA PET/CT imaging 2h post injection was conducted prior to irradiation. The hypoxic volume (HV) was delineated using a tumor-to-muscle value ≥ 1.4. In 13 patients, a repetitive FAZA PET/CT scan was conducted during the radiotherapy treatment. RESULTS: A hypoxic volume could be identified in 25 (63%) of the 40 tumors. FAZA PET HV varied considerably with a range from 0.0 to 30.9 (median: 0.3) cm(3). The T(max)/M(med) ranged from 1.1 to 2.9 (median: 1.5). The distribution of hypoxia among the Human Papillomavirus (HPV) positive (12/16) and negative (13/24) tumors was not significant different. In the FAZA PET/CT scans performed during radiotherapy, hypoxia could be detected in six of the 13 patients. For these six patients the location of HV remained stable in location during radiotherapy treatment, though the size of the HV decreased. In 30 patients a positive correlation was detected between maximum FAZA uptake in the primary tumor and the lymph node. During a median follow up of 19 months a significant difference in disease free survival rate with 93% for patients with non hypoxic tumors and 60% for patients with hypoxic tumors could be detected. CONCLUSION: This study emphasizes the role of FAZA PET/CT imaging as a suitable assay with prognostic potential for detection of hypoxia in HNSCC.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/radioterapia , Hipóxia Celular/fisiologia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/mortalidade , Feminino , Neoplasias de Cabeça e Pescoço/mortalidade , Humanos , Linfonodos/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Nitroimidazóis , Tomografia por Emissão de Pósitrons , Prognóstico , Tomografia Computadorizada por Raios X
8.
Biomark Insights ; 6: 79-82, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21918598

RESUMO

OBJECTIVE: In this prospective study we investigated the role of plasma levels of soluble urokinase plasminogen activator receptor (suPAR) in children with urinary tract infection. MATERIAL AND METHODS: We measured the levels of plasma suPAR during admission in 42 children with suspected acute pyelonephritis and compared the results to acute DMSA scintigraphy. RESULTS: The mean level of plasma suPAR at admission was significantly elevated in children with renal involvement (7.3 ng/ml) assessed by the DMSA scintigraphy compared to children without renal involvement (4.4 ng/ml, P = 0.010). The positive predictive value of suPAR seems high, since all patients without renal involvement had low suPAR values. During treatment the mean level of plasma suPAR decreased. CONCLUSION: We conclude that plasma suPAR could be of clinical use for the diagnosis of acute pyelonephritis and that high levels of plasma suPAR might reflect the level of renal involvement and could therefore be a new indicator for renal scarring.

9.
Radiother Oncol ; 99(3): 418-23, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21723634

RESUMO

PURPOSE: Tumor hypoxia is a known cause of resistance to radiotherapy. The aim of this study was to investigate the prognostic value of hypoxia measured by (18)F-fluoroazomycin arabinoside ((18)F-FAZA) PET or the Eppendorf oxygen electrode in a pre-clinical tumor model. MATERIAL/METHODS: Pretreatment (18)F-FAZA PET scans and blood sampling was conducted in 92 Female CDF1 mice with subcutaneous C3H mammary carcinomas grown in the right foot. Similarly, oxygenation status of 80 equivalent tumors was assessed using an invasive oxygen sensitive electrode. Tumors were then irradiated with a single dose of 55 Gy and local tumor control up to 90 days after the treatment was determined. RESULTS: A significant difference in local tumor control between "more hypoxic" or "less hypoxic" groups separated either by a median (18)F-FAZA PET determined tumor-to-blood ratio (P=0.007; hazard ratio, HR=0.21 [95% CI: 0.06-0.74]), or the fraction of oxygen partial pressure (pO(2)) values ≤2.5 mmHg (P=0.018; HR=0.31 [95% CI: 0.11-0.87]), was found. Both assays showed that the more hypoxic tumors had significantly lower tumor control. CONCLUSION: (18)F-FAZA PET analysis showed that pre treatment tumor hypoxia was prognostic of radiation response. Similar results were obtained when oxygenation status was assessed by the Eppendorf pO(2) Histograph. The results of this study support the role of (18)F-FAZA as a non-invasive prognostic marker for tumor hypoxia.


Assuntos
Radioisótopos de Flúor , Neoplasias Mamárias Experimentais/diagnóstico por imagem , Neoplasias Mamárias Experimentais/radioterapia , Nitroimidazóis , Tomografia por Emissão de Pósitrons/métodos , Animais , Hipóxia Celular , Modelos Animais de Doenças , Eletrodos , Feminino , Camundongos , Prognóstico , Tolerância a Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...