Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BJOG ; 108(2): 215-8, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11236123

RESUMO

The results of screening for the common aneuploidies involving chromosomes 13, 18, 21, X and Y by florescent in-situ hybridisation (FISH) in direct preparations from 100 chorionic villus samples from pregnancies between 10 and 20 weeks' gestation are reported. Samples prepared using routine methods and analysed with commercially available probes, accurately detected 12 cases of fetal aneuploidy, all referred because of developmental abnormality. Three of the four cases where chromosome abnormality was detected in cultured villi but not by the direct fluorescence in situ hybridisation (FISH) assay, were due to confined placental mosaicism. No chromosomal anomalies were found in the 20 low risk cases where the referral reason was a familial single gene disorder. We conclude that the FISH assay with commercial probes may act as an accurate and less labour intensive alternative to direct chromosome analysis of chorionic villus samples. In cytogenetically low risk cases its use can obtain a result within the time needed for DNA analysis and avoid the need to set up cultures.


Assuntos
Aneuploidia , Amostra da Vilosidade Coriônica/métodos , Sondas de DNA , Hibridização in Situ Fluorescente/instrumentação , Hibridização in Situ Fluorescente/normas , Feminino , Humanos , Masculino , Projetos Piloto , Gravidez
2.
J Clin Laser Med Surg ; 18(6): 295-300, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11572223

RESUMO

OBJECTIVE: To assay the safety of the ArF excimer laser in the integrity of human pulp elements. BACKGROUND DATA: The use of lasers in dentistry remains controversial, in spite of their increasing application in medical practice. The main reason for this discrepancy is the frequent report of damage to surrounding tissues and the dental pulp, due to the energy transfer, from the site of laser impact. The progress made on laser technology during the last 10 years, could overcome this obstacle and allow the use of lasers in dentistry. METHODS AND RESULTS: The present study reports the use of the ArF 193 excimer laser, under conditions of strict control of frequency and fluency, for the ablation of dental carries, plaque, and calculi, by the use of a new, articulated arm. We have tested 10 teeth, extracted for prosthetic reasons, immediately after extraction. Our in vitro results show that the ArF193 excimer laser does not produce any harm to the dental pulp (at least at the photo- or electronic microscopy level), whereas in a matter of seconds, it can be effective in removing all dental deposits. In addition, the use of the flexible articulated arm, makes this treatment comfortable and easier for both the dentist and patient. CONCLUSION: Under a strict control of laser technology, and the use of the new articulated arm presented, the use of the ArF excimer laser in dentistry is safe and comfortable.


Assuntos
Cálculos Dentários/cirurgia , Placa Dentária/cirurgia , Terapia a Laser , Polpa Dentária/patologia , Humanos , Técnicas In Vitro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...