Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 144
Filtrar
1.
Int J Cardiol Heart Vasc ; 50: 101323, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38188347

RESUMO

Background: A chronic total coronary occlusion (CTO) is associated with ventricular arrhythmias (VA) in patients with an implantable cardioverter-defibrillator (ICD). Limited data is available on the incidence of VA in CTO patients without an ICD. Objectives: To investigate the incidence of sustained VA in CTO patients after successful CTO revascularization and in patients with untreated CTO or failed CTO revascularization. Methods: Prospective, multicenter observational pilot study including CTO patients who were not eligible for an ICD and had a left ventricular ejection fraction >35 %. We enrolled patients with a successful CTO revascularization (group A) and patients with untreated CTO or failed CTO revascularization (group B). All patients received an implantable loop recorder with remote monitoring. The primary endpoint was sustained VA. Results: Ninety patients were enrolled (mean age 63 ± 10 years, 83.3 % man, mean LVEF 55 ± 8 %). Group A (n = 45) had a higher prevalence of CTO in the left anterior descending artery in comparison to group B (n = 45) (28.9 % versus 4.4 %, P = 0.002). Other baseline characteristics were similar. During a median follow-up time of 26 months (IQR, 19-35), five patients (5.6 %) had a sustained VA. There was no difference in the incidence of sustained VA between groups (3-year cumulative event rate: 8.8 % (group A) versus 4.5 % (Group B), log-rank P = 0.71). Conclusion: Patients with an CTO, who do not qualify for an ICD, have a substantial risk of sustained VA. In our study the incidence was not different between patients with revascularized and those with untreated CTO.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38286881

RESUMO

BACKGROUND: The use of an antibacterial envelope is cost-effective for patients at high risk of developing cardiac implantable electronic device (CIED) infection. The identification of these high-risk patients may be facilitated using a clinical risk score. The aim of the current study is to evaluate the PADIT score for identifying high-risk patients in patients undergoing a CIED procedure in a tertiary academic center. METHODS: This was a retrospective single-center study of consecutive patients undergoing a CIED procedure between January 2016 and November 2021. Patients who received an antibacterial envelope were excluded from this study. The primary endpoint was hospitalization for a CIED infection in the first year after the procedure. RESULTS: A total of 2333 CIED procedures were performed in the study period (mean age 61.6 ± 16.3 years, male sex 64.5%, previous CIED infection 1.7%, immunocompromised 5.4%). The median PADIT score was 4 (interquartile range, 2-6). CIED infection occurred in 10 patients (0.43%). The PADIT score had good discrimination in predicting major CIED infection (C-statistic 0.70; 95% confidence interval [CI] 0.54 to 0.86, P = 0.03). Using an optimal PADIT score cut-off value of 7, the risk of CIED infection was higher in the patients with a PADIT score of ≥ 7 in comparison to those with a lower PADIT score (1.23% vs. 0.26%, P = 0.02; odds ratio 4.8, 95% CI 1.4 to 16.6, P = 0.01). CONCLUSIONS: The PADIT score is a clinically useful score for identifying patients at high risk of developing CIED infection. The use of an antibacterial envelope in these high-risk patients may be cost-effective.

3.
Int J Cardiol ; 390: 131205, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37482094

RESUMO

BACKGROUND: The presence of an untreated chronic total coronary occlusion (CTO) is associated with a higher risk of ventricular arrhythmias (VAs). This increased risk may be modulated by the presence of an existing scar. OBJECTIVES: To evaluate whether scar size is associated with VA in patients with an implantable cardioverter-defibrillator (ICD) and a CTO. METHODS: In this retrospective study we included patients with a CTO that received an ICD between 2005 and 2015. Scar size was estimated using the Selvester QRS score on a baseline 12­lead ECG. The primary endpoint was any appropriate ICD therapy. RESULTS: Our study population comprised 148 CTO patients with a median scar size at baseline of 18% (IQR, 9-27%). Patients with a scar size ≥18% more often had a CTO located in the left anterior descending artery and a higher proportion of poor left ventricular function (<35%) and infarct-related CTO compared to patients with a smaller scar size (<18%). During a median follow-up of 35 months (interquartile range [IQR], 8-60 months), 42 patients (28%) received appropriate ICD therapy. The cumulative 5-year event rate was higher in the patients with a large scar in comparison to those with a smaller or no scar (36% versus 19%, P = 0.04). Multivariable Cox regression analysis demonstrated that large scar and diabetes mellitus were independent factors associated with appropriate ICD therapy. CONCLUSION: In ICD recipients with an untreated CTO, a larger scar is an independent factor associated with an increased risk of VA.


Assuntos
Oclusão Coronária , Desfibriladores Implantáveis , Humanos , Oclusão Coronária/diagnóstico , Oclusão Coronária/diagnóstico por imagem , Estudos Retrospectivos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Desfibriladores Implantáveis/efeitos adversos , Fatores de Risco , Resultado do Tratamento
4.
JACC Clin Electrophysiol ; 9(8 Pt 1): 1368-1378, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37141904

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) are frequently used for primary and secondary prevention in patients with cardiomyopathies due to different etiologies. However, long-term outcome studies in patients with noncompaction cardiomyopathy (NCCM) are scarce. OBJECTIVES: This study summarizes the long-term outcome of ICD therapy in patients with NCCM compared with those with dilated cardiomyopathy (DCM) or hypertrophic cardiomyopathy (HCM). METHODS: Prospective data from our single-center ICD registry were used to analyze the ICD interventions and survival in patients with NCCM (n = 68) compared with patients with DCM (n = 458) and patients with HCM (n = 158) from January 2005 to January 2018. RESULTS: This NCCM population with an ICD for primary prevention comprised 56 (82%) patients with a median age of 43 years and 52% males, compared with 85% in patients with DCM and 79% in patients with HCM (P = 0.20). During a median follow-up of 5 years (IQR: 2.0-6.9 years), appropriate and inappropriate ICD interventions were not significantly different. Nonsustained ventricular tachycardia during Holter monitoring in patients with NCCM was the only significant risk factor for appropriate ICD therapy in patients with NCCM, with a HR of 5.29 (95% CI: 1.12-24.96). The long-term survival was significantly better in the univariable analysis in the NCCM group. However, there was no difference in multivariable Cox regression analyses between the cardiomyopathy groups. CONCLUSIONS: At 5 years of follow-up, the rate of appropriate and inappropriate ICD interventions in NCCM was comparable to that in DCM or HCM. In multivariable analysis, no differences in survival were found between the cardiomyopathy groups.


Assuntos
Cardiomiopatias , Cardiomiopatia Dilatada , Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Masculino , Humanos , Adulto , Feminino , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/terapia , Estudos Prospectivos , Cardiomiopatias/complicações , Cardiomiopatias/terapia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/terapia , Fatores de Risco
5.
Eur Heart J ; 44(31): 2911-2926, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37216272

RESUMO

AIMS: Telemonitoring modalities in heart failure (HF) have been proposed as being essential for future organization and transition of HF care, however, efficacy has not been proven. A comprehensive meta-analysis of studies on home telemonitoring systems (hTMS) in HF and the effect on clinical outcomes are provided. METHODS AND RESULTS: A systematic literature search was performed in four bibliographic databases, including randomized trials and observational studies that were published during January 1996-July 2022. A random-effects meta-analysis was carried out comparing hTMS with standard of care. All-cause mortality, first HF hospitalization, and total HF hospitalizations were evaluated as study endpoints. Sixty-five non-invasive hTMS studies and 27 invasive hTMS studies enrolled 36 549 HF patients, with a mean follow-up of 11.5 months. In patients using hTMS compared with standard of care, a significant 16% reduction in all-cause mortality was observed [pooled odds ratio (OR): 0.84, 95% confidence interval (CI): 0.77-0.93, I2: 24%], as well as a significant 19% reduction in first HF hospitalization (OR: 0.81, 95% CI 0.74-0.88, I2: 22%) and a 15% reduction in total HF hospitalizations (pooled incidence rate ratio: 0.85, 95% CI 0.76-0.96, I2: 70%). CONCLUSION: These results are an advocacy for the use of hTMS in HF patients to reduce all-cause mortality and HF-related hospitalizations. Still, the methods of hTMS remain diverse, so future research should strive to standardize modes of effective hTMS.


Assuntos
Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/terapia , Hospitalização
6.
Cardiovasc Drugs Ther ; 37(6): 1243-1248, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36227441

RESUMO

BACKGROUND: The presence of atrial fibrillation (AF) in heart failure (HF) patients with reduced ejection fraction is common and associated with an increased risk of stroke, hospitalization and mortality. Recent research findings indicate that a reduction in nicotinamide adenine dinucleotide (NAD+) levels results in mitochondrial dysfunction, DNA damage and consequently cardiomyocyte impairment in experimental and clinical HF and AF. The HF-AF ENERGY trial aims to investigate the cardioprotective effects of the NAD+ precursor nicotinamide riboside (NR) treatment in ischemic heart disease patients diagnosed with AF. STUDY DESIGN: The HF-AF ENERGY trial is a prospective intervention study. The study consists of a (retrospective) 4 months observation period and a 4 months intervention period. The cardioprotective effect of NR on AF burden is investigated by remote monitoring software of implantable cardiac defibrillators (ICDs), which enables continuous atrial rhythm monitoring detection. Cardiac dimension and function are examined by echocardiography. Laboratory blood analysis is performed to determine mitochondrial function markers and energy metabolism. All the study parameters are assessed at two fixed time points (pre- and post-treatment). Pre- and post-treatment outcomes are compared to determine the effects of NR treatment on AF burden, mitochondrial function markers and energy metabolism. CONCLUSION: The HF-AF ENERGY trial investigates the cardioprotective effects of NR on AF burden and whether NR normalizes blood-based mitochondrial function markers and energy metabolites of the NAD metabolome in ischemic heart disease patients diagnosed with AF. The study outcomes elucidate whether NAD+ metabolism can be used as a future therapy for HF patients with AF.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Isquemia Miocárdica , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/complicações , NAD , Estudos Prospectivos , Estudos Retrospectivos , Volume Sistólico , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Isquemia Miocárdica/complicações
8.
Ann Noninvasive Electrocardiol ; 27(3): e12960, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35481956

RESUMO

BACKGROUND: Insertable cardiac monitors (ICMs) are increasingly used to evaluate the atrial fibrillation (AF) burden after catheter ablation of AF. BioMonitor III (BM3) is an ICM with a long sensing vector, which enhances sensing capabilities. The AF detection algorithm of the BM3 is based on R-R interval variability. OBJECTIVE: To evaluate the performance of the AF detection algorithm of BM3 in patients before and after catheter ablation of AF using simultaneous Holter recordings. METHODS: In this prospective study, we enrolled patients scheduled for catheter ablation of paroxysmal or persistent AF. After BM3 implantation, patients had a 4 days Holter registration before and 3 months after ablation. All true AF episodes ≥2 min on the Holter were annotated and matched with BM3 detected AF detections. RESULTS: Thirty-one patients were enrolled (mean age 60 ± 8, 74% male, 68% paroxysmal AF). Fifty-six Holter registrations were performed in 30 patients. Twelve patients demonstrated at least one true AF episode with a total AF duration of 570 h. The AF burden accuracy of BM3 before catheter ablation was 99.6%, with a duration sensitivity of 98.6% and a duration specificity of 99.9%. The AF burden accuracy of BM3 after catheter ablation was 99.8%, with a duration sensitivity of 90.2% and a duration specificity of 99.9%. Overall, the AF burden detected on the Holter and BM3 demonstrated a high Pearson correlation coefficient of 0.996. CONCLUSION: BM3 accurately detects AF burden in patients before and after catheter ablation of AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Eletrocardiografia , Eletrocardiografia Ambulatorial/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
9.
Int J Cardiol Heart Vasc ; 39: 101005, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35310376

RESUMO

Background: Direct oral anticoagulants (DOACs) are the preferred choice of oral anticoagulation in patients with atrial fibrillation (AF). Randomized trials have demonstrated the efficacy and safety of DOAC in patients undergoing a cardiac implantable electronic device procedure (CIED); however, there is limited real-world data. Objective: To evaluate the outcome of patients undergoing an elective CIED procedure in a tertiary referral center with an interrupted DOAC or continued vitamin K antagonist (VKA) regimen. Methods: This was a retrospective single-center study of consecutive patients with AF undergoing an elective CIED procedure between January 2016 and June 2019. The primary endpoint was a clinically significant pocket hematoma < 30 days after surgery. The secondary endpoint was any systemic thromboembolic complication < 30 days after surgery. Results: Of a total of 1,033 elective CIED procedures, 283 procedures were performed in patients with AF using oral anticoagulation. One-third of the procedures were performed under DOAC (N = 81, 29%) and the remainder under VKA (N = 202, 71%). The DOAC group was younger, had less chronic renal disease, more paroxysmal AF and a lower HAS-BLED score. The VKA group more often underwent a generator change only in comparison to the DOAC group. Clinically significant pocket hematoma occurred in 5 patients (2.5%) in the VKA group and did not occur in the DOAC group (P = 0.33). There were no thromboembolic events reported. Conclusion: In patients with AF undergoing an elective CIED procedure, the risk of a pocket hematoma and a systemic thromboembolic event is comparably low when using either continued VKA or interrupted DOAC.

10.
Sensors (Basel) ; 21(11)2021 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-34071624

RESUMO

The management of heart failure remains challenging despite evidence-based medical and pharmacological advances, especially in the ambulatory setting. There is an urgent need to develop strategies to reduce hospitalizations and readmission rates due to heart failure. Frequent monitoring of high-risk patients is imperative, and with the development of wireless and remote technology, frequent monitoring is now possible via remote monitoring. Nowadays, remote management of patients with cardiac implantable electronic devices is being increasingly adopted and integrated into clinical practice. Several clinical trials studied the impact of remote monitoring on clinical outcomes in patients with implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization defibrillators (CRT-Ds). This point of view will focus on the remote monitoring of ICDs and CRT-Ds in patients with heart failure and discusses whether remote monitoring can be used as a potential instrument for the early identification of patients at risk of worsening heart failure.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos
11.
ESC Heart Fail ; 8(5): 3726-3736, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34184828

RESUMO

AIMS: Risk stratification models of sudden cardiac death (SCD) are based on the assumption that risk factors of SCD affect risk to a similar extent in both sexes. The aim of the study is to evaluate differences in clinical outcomes between sexes and evaluate whether risk factors associated with appropriate device therapy (ADT) differ between men and women. METHODS AND RESULTS: We performed a cohort study of implantable cardioverter defibrillator (ICD) patients referred for primary or secondary prevention of SCD between 2009 and 2018. Multivariable Cox regression models for prediction of ADT were constructed for men and women separately. Of 2300 included patients, 571 (25%) were women. Median follow-up was 4.6 (inter-quartile range: 4.4-4.9) years. Time to ADT was shorter for men compared with women [hazard ratio (HR) 1.71, P < 0.001], as was time to mortality (HR 1.37, P = 0.003). In women, only secondary prevention ICD therapy (HR 1.82, P < 0.01) was associated with ADT, whereas higher age (HR 1.20, P < 0.001), absence of left bundle branch block (HR 0.72, P = 0.01), and secondary prevention therapy (HR 1.80, P < 0.001) were independently associated with ADT in men. None of the observed parameters showed a distinctive sex-specific pattern in ADT. CONCLUSIONS: Male ICD patients were at higher risk of ADT and death compared with female ICD patients, irrespective of an ischaemic or non-ischaemic underlying cardiomyopathy. Our study highlights the importance to stratify outcomes of ICD trials by sex, as study results differ between men and women. However, none of the available clinical parameters showed a clear sex-specific relation to ventricular arrhythmias. As a consequence, sex-specific risk stratification models of SCD using commonly available clinical parameters could not be derived.


Assuntos
Desfibriladores Implantáveis , Arritmias Cardíacas , Estudos de Coortes , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Feminino , Humanos , Masculino , Medição de Risco
12.
J Cardiovasc Electrophysiol ; 32(6): 1687-1694, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33825257

RESUMO

INTRODUCTION: Cardiac resynchronization defibrillator (CRT-D) as primary prevention is known to reduce mortality. At the time of replacement, higher age and comorbidities may attenuate the benefit of implantable cardioverter-defibrillator (ICD) therapy. The purpose of this study was to evaluate the progression of comorbidities after implantation and their association with mortality following CRT-D generator replacement. In addition, a risk score was developed to identify patients at high risk for mortality after replacement. METHODS AND RESULTS: We identified patients implanted with a primary prevention CRT-D (n = 648) who subsequently underwent elective generator replacement (n = 218) from two prospective ICD registries. The cohort consisted of 218 patients (median age: 70 years, male gender: 73%, mean left ventricular ejection fraction [LVEF]: 36 ± 11% at replacement). Median follow-up after the replacement was 4.2 years during which 64 patients (29%) died and 11 patients (5%) received appropriate ICD shocks. An increase in comorbidities was observed in 77 patients (35%). The 5-year mortality rate was 41% in patients with ≥2 comorbidities at the time of replacement. A risk score incorporating age, gender, LVEF, atrial fibrillation, anemia, chronic kidney disease, and history of appropriate ICD shocks at time of replacement accurately predicted 5-year mortality (C-statistic 0.829). Patients with a risk score of greater than 2.5 had excess mortality at 5-year postreplacement compared with patients with a risk score less than 1.5 (57% vs. 6%; p < .001). CONCLUSION: A simple risk score accurately predicts 5-year mortality after replacement in CRT-D patients, as patients with a risk score of greater than 2.5 are at high risk of dying despite ICD protection.


Assuntos
Fibrilação Atrial , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Idoso , Fibrilação Atrial/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
13.
J Am Heart Assoc ; 10(7): e018063, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33787324

RESUMO

Background One third of primary prevention implantable cardioverter-defibrillator patients receive appropriate therapy, but all remain at risk of defibrillator complications. Information on these complications in contemporary cohorts is limited. This study assessed complications and their risk factors after defibrillator implantation in a Dutch nationwide prospective registry cohort and forecasts the potential reduction in complications under distinct scenarios of updated indication criteria. Methods and Results Complications in a prospective multicenter registry cohort of 1442 primary implantable cardioverter-defibrillator implant patients were classified as major or minor. The potential for reducing complications was derived from a newly developed prediction model of appropriate therapy to identify patients with a low probability of benefitting from the implantable cardioverter-defibrillator. During a follow-up of 2.2 years (interquartile range, 2.0-2.6 years), 228 complications occurred in 195 patients (13.6%), with 113 patients (7.8%) experiencing at least one major complication. Most common ones were lead related (n=93) and infection (n=18). Minor complications occurred in 6.8% of patients, with lead-related (n=47) and pocket-related (n=40) complications as the most prevailing ones. A surgical reintervention or additional hospitalization was required in 53% or 61% of complications, respectively. Complications were strongly associated with device type. Application of stricter implant indication results in a comparable proportional reduction of (major) complications. Conclusions One in 13 patients experiences at least one major implantable cardioverter-defibrillator-related complication, and many patients undergo a surgical reintervention. Complications are related to defibrillator implantations, and these should be discussed with the patient. Stricter implant indication criteria and careful selection of device type implanted may have significant clinical and financial benefits.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Cardioversão Elétrica , Complicações Pós-Operatórias , Implantação de Prótese/efeitos adversos , Idoso , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/classificação , Desfibriladores Implantáveis/estatística & dados numéricos , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Análise de Falha de Equipamento/métodos , Análise de Falha de Equipamento/estatística & dados numéricos , Feminino , Humanos , Masculino , Avaliação das Necessidades , Países Baixos/epidemiologia , Seleção de Pacientes , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros/estatística & dados numéricos , Reoperação/estatística & dados numéricos , Medição de Risco , Fatores de Risco
14.
Europace ; 23(6): 887-897, 2021 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-33582797

RESUMO

AIMS: This study was performed to develop and externally validate prediction models for appropriate implantable cardioverter-defibrillator (ICD) shock and mortality to identify subgroups with insufficient benefit from ICD implantation. METHODS AND RESULTS: We recruited patients scheduled for primary prevention ICD implantation and reduced left ventricular function. Bootstrapping-based Cox proportional hazards and Fine and Gray competing risk models with likely candidate predictors were developed for all-cause mortality and appropriate ICD shock, respectively. Between 2014 and 2018, we included 1441 consecutive patients in the development and 1450 patients in the validation cohort. During a median follow-up of 2.4 (IQR 2.1-2.8) years, 109 (7.6%) patients received appropriate ICD shock and 193 (13.4%) died in the development cohort. During a median follow-up of 2.7 (IQR 2.0-3.4) years, 105 (7.2%) received appropriate ICD shock and 223 (15.4%) died in the validation cohort. Selected predictors of appropriate ICD shock were gender, NSVT, ACE/ARB use, atrial fibrillation history, Aldosterone-antagonist use, Digoxin use, eGFR, (N)OAC use, and peripheral vascular disease. Selected predictors of all-cause mortality were age, diuretic use, sodium, NT-pro-BNP, and ACE/ARB use. C-statistic was 0.61 and 0.60 at respectively internal and external validation for appropriate ICD shock and 0.74 at both internal and external validation for mortality. CONCLUSION: Although this cohort study was specifically designed to develop prediction models, risk stratification still remains challenging and no large group with insufficient benefit of ICD implantation was found. However, the prediction models have some clinical utility as we present several scenarios where ICD implantation might be postponed.


Assuntos
Desfibriladores Implantáveis , Antagonistas de Receptores de Angiotensina , Inibidores da Enzima Conversora de Angiotensina , Estudos de Coortes , Morte Súbita Cardíaca/prevenção & controle , Humanos , Prevenção Primária , Fatores de Risco
15.
Int J Cardiol ; 330: 73-79, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33516838

RESUMO

BACKGROUND: The Heart Failure (HF) Meta-score may be useful in predicting prognosis in patients with primary prevention cardiac resynchronization defibrillators (CRT-D) considering the competing risk of appropriate defibrillator shock versus mortality. METHODS: Data from 648 consecutive patients from two centers were used for the evaluation of the performance of the HF Meta-score. The primary endpoint was mortality and the secondary endpoint was time to first appropriate implantable cardioverter-defibrillator (ICD) shock or death without prior appropriate ICD shock. Fine-Gray model was used for competing risk regression analysis. RESULTS: In the entire cohort, 237 patients died over a median follow-up of 5.2 years. Five-year cumulative incidence of mortality ranged from 12% to 53%, for quintiles 1 through 5 of the HF Meta-score, respectively (log-rank P < 0.001). Compared with the lowest quintile, mortality risk was higher in the highest quintile (HR 6.9; 95%CI 3.7-12.8). The HF Meta-score had excellent calibration, accuracy, and good discrimination in predicting mortality (C-statistic 0.76 at 1-year and 0.71 at 5-year). The risk of death without appropriate ICD shock was higher in risk quintile 5 compared to quintile 1 (sub HR 5.8; 95%CI 3.1-11.0, P < 0.001). CONCLUSIONS: Our study demonstrated a good ability of the HF Meta-score to predict survival in HF patients treated with CRT-D as primary prevention. The HF Meta-score proved to be useful in identifying a subgroup with a significantly poor prognosis despite a CRT-D.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Prognóstico , Medição de Risco , Fatores de Risco , Resultado do Tratamento
16.
Cardiology ; 146(2): 207-212, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33477163

RESUMO

AIMS: The aim of the present study was to compare the rate of actionable arrhythmic events between patients with hypertrophic cardiomyopathy (HCM) who are monitored with an insertable cardiac monitor (ICM) or Holter monitoring. METHODS: We studied 50 patients (mean age 52 years, 72% men) with HCM at low or intermediate risk for sudden cardiac death (SCD), of whom 25 patients received an ICM between November 2014 and February 2019. We retrospectively identified a control group of 25 patients who were matched on age, sex, and HCM Risk-SCD score category. The mean HCM Risk-SCD score was 3.41 ± 1.31 and 3.31 ± 1.43 for the ICM and Holter groups, respectively. The primary endpoint was an actionable event which was defined as an arrhythmic event resulting in a change in patient management. The secondary endpoint was the occurrence of ventricular tachycardia (VT). RESULTS: The cumulative actionable event rate at 30 months was higher in the ICM group (51 vs. 27%, log-rank p value <0.01). De novo atrial fibrillation requiring oral anticoagulation occurred only in the ICM group (n = 3). Overall, 4 implantable cardioverter-defibrillators were implanted for primary prevention (n = 2 in each group). The cumulative rate of VT episodes at 30 months was similar between groups (23% [ICM group] vs. 42% [Holter group], log-rank p value = 0.71). Furthermore, the characteristics of VT were similar between groups with regard to the number of beats and rate. CONCLUSIONS: In adults with HCM, an ICM will detect more arrhythmic events requiring an intervention than a conventional Holter strategy. In contrast, the diagnostic yield of detecting VT seems similar for both groups.


Assuntos
Fibrilação Atrial , Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Taquicardia Ventricular , Adulto , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco
18.
J Interv Card Electrophysiol ; 62(2): 239-248, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33029695

RESUMO

PURPOSE: During transvenous lead extraction (TLE), the femoral snare has mainly been used as a bail-out procedure. The purpose of the present study is to evaluate the efficacy and safety of a TLE approach with a low threshold to use a combined superior and femoral approach. METHODS: This is a single-center observational study including all TLE procedures between 2012 till 2019. RESULTS: A total of 264 procedures (median age 63 (51-71) years, 67.0% male) were performed in the study period. The main indications for TLE were lead malfunction (67.0%), isolated pocket infection (17.0%) and systemic infection (11.7%). The median dwelling time of the oldest targeted lead was 6.8 (4.0-9.7) years. The techniques used to perform the procedure were the use of a femoral snare only (30%), combined rotational powered sheath and femoral snare (25%), manual traction only (20%), rotational powered sheath only (17%) and locking stylet only (8%). The complete and clinical procedural success rate was 90.2% and 97.7%, respectively, and complete lead removal rate was 94.1% of all targeted leads. The major and minor procedure-related complication rates were 1.1% and 10.2%, respectively. There was one case (0.4%) of emergent sternotomy for management of cardiac avulsion. Furthermore, there were 5 in-hospital non-procedure-related deaths (1.9%), of whom 4 were related to septic shock due to a Staphylococcus aureus endocarditis after an uncomplicated TLE with complete removal of all leads. CONCLUSION: An effective and safe TLE procedure can be achieved by using the synergy between a superior and femoral approach.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
20.
Gen Hosp Psychiatry ; 66: 154-160, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32866884

RESUMO

OBJECTIVE: To examine whether anxiety and depression at time of implantation of an implantable cardioverter defibrillator (ICD) is associated with ventricular arrhythmias (VAs) and mortality 7 years later. METHODS: A cohort of 399 patients (80% men; mean (SD) age = 58.3 (12.2)) implanted with an ICD completed the Hospital Anxiety and Depression Scale (HADS) and the State-Trait Anxiety Inventory at time of implantation. Patients were followed up for VAs and mortality at 7 years. RESULTS: At 7-years follow-up, 34% of the patients had died and 38% had experienced VAs. Baseline depression (score ≥ 8) (HR:2.10; 95% CI:1.44-3.05, p < 0.001) was associated with 7-year mortality in adjusted analyses while state anxiety (score ≥ 40) (HR:1.45; 95% CI:1.02-2.06, p = 0.039) and trait anxiety (score ≥ 40) (HR:1.51; 95% CI:1.06-2.16, p = 0.022) showed a trend towards an association with mortality. No association was found between VAs and anxiety and depression. There was a dose-response relationship with higher burden of anxiety (HR:2.13; 95% CI:1.31-3.46, p = 0.002) and depression (HR:2.13; 95% CI:1.33-3.42, p = 0.002) measured with the HADS (scores < 8, 8-10 and > 10) being associated with an increased risk of mortality. CONCLUSION: Patients with depression had greater risk of mortality, whereas anxiety only showed a trend. Neither anxiety nor depression was associated with VAs during follow-up.


Assuntos
Ansiedade/epidemiologia , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/estatística & dados numéricos , Depressão/epidemiologia , Avaliação de Resultados em Cuidados de Saúde , Personalidade , Adulto , Idoso , Arritmias Cardíacas/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...