Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
1.
J Ultrasound Med ; 43(3): 513-523, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38050780

RESUMO

OBJECTIVES: The number and distribution of lung ultrasound (LUS) imaging artifacts termed B-lines correlate with the presence of acute lung disease such as infection, acute respiratory distress syndrome (ARDS), and pulmonary edema. Detection and interpretation of B-lines require dedicated training and is machine and operator-dependent. The goal of this study was to identify radio frequency (RF) signal features associated with B-lines in a cohort of patients with cardiogenic pulmonary edema. A quantitative signal indicator could then be used in a single-element, non-imaging, wearable, automated lung ultrasound sensor (LUSS) for continuous hands-free monitoring of lung fluid. METHODS: In this prospective study a 10-zone LUS exam was performed in 16 participants, including 12 patients admitted with acute cardiogenic pulmonary edema (mean age 60 ± 12 years) and 4 healthy controls (mean age 44 ± 21). Overall,160 individual LUS video clips were recorded. The LUS exams were performed with a phased array probe driven by an open-platform ultrasound system with simultaneous RF signal collection. RF data were analyzed offline for candidate B-line indicators based on signal amplitude, temporal variability, and frequency spectrum; blinded independent review of LUS images for the presence or absence of B-lines served as ground truth. Predictive performance of the signal indicators was determined with receiving operator characteristic (ROC) analysis with k-fold cross-validation. RESULTS: Two RF signal features-temporal variability of signal amplitude at large depths and at the pleural line-were strongly associated with B-line presence. The sensitivity and specificity of a combinatorial indicator were 93.2 and 58.5%, respectively, with cross-validated area under the ROC curve (AUC) of 0.91 (95% CI = 0.80-0.94). CONCLUSION: A combinatorial signal indicator for use with single-element non-imaging LUSS was developed to facilitate continuous monitoring of lung fluid in patients with respiratory illness.


Assuntos
Edema Pulmonar , Síndrome do Desconforto Respiratório , Humanos , Pessoa de Meia-Idade , Idoso , Adulto Jovem , Adulto , Estudos Prospectivos , Pulmão/diagnóstico por imagem , Sensibilidade e Especificidade , Ultrassonografia/métodos
2.
Ultrasonics ; 138: 107225, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38141356

RESUMO

This work was focused on the newly developed ultrasonic approach for non-invasive surgery - boiling histotripsy (BH) - recently proposed for mechanical ablation of tissues using pulsed high intensity focused ultrasound (HIFU). The BH lesion is known to depend in size and shape on exposure parameters and mechanical properties, structure and composition of tissue being treated. The aim of this work was to advance the concept of BH dose by investigating quantitative relationships between the parameters of the lesion, pulsing protocols, and targeted tissue properties. A HIFU focus of a 1.5 MHz 256-element array driven by power-enhanced Verasonics system was electronically steered along the grid within 12 × 4 × 12 mm volume to produce volumetric lesions in porcine liver (soft, with abundant collagenous structures) and bovine myocardium (stiff, homogenous cellular) ex vivo tissues with various pulsing protocols (1-10 ms pulses, 1-15 pulses per point). Quantification of the lesion size and completeness was performed through serial histological sectioning, and a computer vision approach using a combination of manual and automated detection of fully fractionated and residual tissue based on neural network ResNet-18 was developed. Histological sample fixation led to underestimation of BH ablation rate compared to the ultrasound-based estimations, and provided similar qualitative feedback as did gross inspection. This suggests that gross observation may be sufficient for qualitatively evaluating the BH treatment completeness. BH efficiency in liver tissue was shown to be insensitive to the changes in pulsing protocol within the tested parameter range, whereas in bovine myocardium the efficiency increased with either increasing pulse length or number of pulses per point or both. The results imply that one universal mechanical dose metric applicable to an arbitrary tissue type is unlikely to be established. The dose metric as a product of the BH pulse duration and the number of pulses per sonication point (BHD1) was shown to be more relevant for initial planning of fractionation of collagenous tissues. The dose metric as a number of pulses per point (BHD2) is more suitable for the treatment planning of softer targets primarily containing cellular tissue, allowing for significant acceleration of treatment using shorter pulses.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Animais , Bovinos , Suínos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Miocárdio , Fígado/diagnóstico por imagem , Fígado/cirurgia , Ultrassonografia , Sonicação
3.
Artigo em Inglês | MEDLINE | ID: mdl-37318967

RESUMO

Boiling histotripsy (BH) is a pulsed high-intensity focused ultrasound (HIFU) method relying on the generation of high-amplitude shocks at the focus, localized enhanced shock-wave heating, and bubble activity driven by shocks to induce tissue liquefaction. BH uses sequences of 1-20 ms long pulses with shock fronts of over 60 MPa amplitude, initiates boiling at the focus of the HIFU transducer within each pulse, and the remainder shocks of the pulse then interact with the boiling vapor cavities. One effect of this interaction is the creation of a prefocal bubble cloud due to reflection of shocks from the initially generated mm-sized cavities: the shocks are inverted when reflected from a pressure-release cavity wall resulting in sufficient negative pressure to reach intrinsic cavitation threshold in front of the cavity. Secondary clouds then form due to shock-wave scattering from the first one. Formation of such prefocal bubble clouds has been known as one of the mechanisms of tissue liquefaction in BH. Here, a methodology is proposed to enlarge the axial dimension of this bubble cloud by steering the HIFU focus toward the transducer after the initiation of boiling until the end of each BH pulse and thus to accelerate treatment. A BH system comprising a 1.5 MHz 256-element phased array connected to a Verasonics V1 system was used. High-speed photography of BH sonications in transparent gels was performed to observe the extension of the bubble cloud resulting from shock reflections and scattering. Volumetric BH lesions were then generated in ex vivo tissue using the proposed approach. Results showed up to almost threefold increase of the tissue ablation rate with axial focus steering during the BH pulse delivery compared to standard BH.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Transdutores , Sonicação
4.
Artigo em Inglês | MEDLINE | ID: mdl-36197870

RESUMO

Boiling histotripsy (BH) is a mechanical tissue liquefaction method that uses sequences of millisecond-long high intensity focused ultrasound (HIFU) pulses with shock fronts. The BH treatment generates bubbles that move within the sonicated volume due to acoustic radiation force. Since the velocity of the bubbles and tissue debris is expected to depend on the lesion size and liquefaction completeness, it could provide a quantitative metric of the treatment progression. In this study, the motion of bubble remnants and tissue debris immediately following BH pulses was investigated using high-pulse repetition frequency (PRF) plane-wave color Doppler ultrasound in ex vivo myocardium tissue. A 256-element 1.5 MHz spiral HIFU array with a coaxially integrated ultrasound imaging probe (ATL P4-2) produced 10 ms BH pulses to form volumetric lesions with electronic beam steering. Prior to performing volumetric BH treatments, the motion of intact myocardium tissue and anticoagulated bovine blood following isolated BH pulses was assessed as two limiting cases. In the liquid blood the velocity of BH-induced streaming at the focus reached over 200 cm/s, whereas the intact tissue was observed to move toward the HIFU array consistent with elastic rebound of tissue. Over the course of volumetric BH treatments tissue motion at the focus locations was dependent on the axial size of the forming lesion relative to the corresponding size of the HIFU focal area. For axially small lesions, the maximum velocity after the BH pulse was directed toward the HIFU transducer and monotonically increased over time from about 20-100 cm/s as liquefaction progressed, then saturated when tissue was fully liquefied. For larger lesions obtained by merging multiple smaller lesions in the axial direction, the high-speed streaming away from the HIFU transducer was observed at the point of full liquefaction. Based on these observations, the maximum directional velocity and its location along the HIFU propagation axis were proposed and evaluated as candidate metrics of BH treatment completeness.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Miocárdio , Animais , Bovinos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Movimento (Física) , Transdutores , Ondas de Choque de Alta Energia , Ultrassonografia Doppler em Cores
5.
Artigo em Inglês | MEDLINE | ID: mdl-35981067

RESUMO

One of the challenges of transcutaneous high-intensity focused ultrasound (HIFU) therapies, especially ones relying heavily on shock formation, such as boiling histotripsy (BH), is the loss of focusing from aberration induced by the heterogeneities of the body wall. Here, a methodology to execute aberration correction in vivo is proposed. A custom BH system consisting of a 1.5-MHz phased array of 256 elements connected to a Verasonics V1 system is used in pulse/echo mode on a porcine model under general anesthesia. Estimation of the time shifts needed to correct for aberration in the liver and kidney is done by maximizing the value of the coherence factor on the acquired backscattered signals. As this process requires multiple pulse/echo sequences on a moving target to converge to a solution, tracking is also implemented to ensure that the same target is used between each iteration. The method was validated by comparing the acoustic power needed to generate a boiling bubble at one target with aberration correction and at another target within a 5-mm radius without aberration correction. Results show that the aberration correction effectively lowers the acoustic power required to reach boiling by up to 45%, confirming that it indeed restored formation of the nonlinear shock front at the focus.


Assuntos
Tratamento por Ondas de Choque Extracorpóreas , Ablação por Ultrassom Focalizado de Alta Intensidade , Abdome , Animais , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Rim , Fígado/diagnóstico por imagem , Fígado/cirurgia , Suínos
6.
J Acoust Soc Am ; 151(5): 3007, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35649925

RESUMO

Phase aberration induced by soft tissue inhomogeneities often complicates high-intensity focused ultrasound (HIFU) therapies by distorting the field and, previously, we designed and fabricated a bilayer gel phantom to reproducibly mimic that effect. A surface pattern containing size scales relevant to inhomogeneities of a porcine body wall was introduced between gel materials with fat- and muscle-like acoustic properties-ballistic and polyvinyl alcohol gels. Here, the phantom design was refined to achieve relevant values of ultrasound absorption and scattering and make it more robust, facilitating frequent handling and use in various experimental arrangements. The fidelity of the interfacial surface of the fabricated phantom to the design was confirmed by three-dimensional ultrasound imaging. The HIFU field distortions-displacement of the focus, enlargement of the focal region, and reduction of focal pressure-produced by the phantom were characterized using hydrophone measurements with a 1.5 MHz 256-element HIFU array and found to be similar to those induced by an ex vivo porcine body wall. A phase correction approach was used to mitigate the aberration effect on nonlinear focal waveforms and enable boiling histotripsy treatments through the phantom or body wall. The refined phantom represents a practical tool to explore HIFU therapy systems capabilities.


Assuntos
Tratamento por Ondas de Choque Extracorpóreas , Ablação por Ultrassom Focalizado de Alta Intensidade , Acústica , Animais , Géis , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imagens de Fantasmas , Suínos , Ultrassonografia
7.
Soins Psychiatr ; 42(335): 38-42, 2021.
Artigo em Francês | MEDLINE | ID: mdl-34266549

RESUMO

The treatment of post-traumatic stress disorder is one of the priorities of the armed forces' health service, but there are few measures for families, who are nevertheless the first to be affected. At the Robert-Picqué army training hospital in Bordeaux, an information and exchange day for carers was set up in 2018. It takes place once every term. Here is a look at how it works, its benefits and its limitations.


Assuntos
Militares , Transtornos de Estresse Pós-Traumáticos , Cuidadores , Humanos
8.
Artigo em Inglês | MEDLINE | ID: mdl-33905328

RESUMO

Extracorporeal boiling histotripsy (BH), a noninvasive method for mechanical tissue disintegration, is getting closer to clinical applications. However, the motion of the targeted organs, mostly resulting from the respiratory motion, reduces the efficiency of the treatment. Here, a practical and affordable unidirectional respiratory motion compensation method for BH is proposed and evaluated in ex vivo tissues. The BH transducer is fixed on a robotic arm following the motion of the skin, which is tracked using an inline ultrasound imaging probe. In order to compensate for system lags and obtain a more accurate compensation, an autoregressive motion prediction model is implemented. BH pulse gating is also implemented to ensure targeting accuracy. The system is then evaluated with ex vivo BH treatments of tissue samples undergoing motion simulating breathing with the movement of amplitudes between 5 and 10 mm, the frequency between 16 and 18 breaths/min, and a maximum speed of 14.2 mm/s. Results show a reduction of at least 89% of the value of the targeting error during treatment while only increasing the treatment time by no more than 1%. The lesions obtained by treating with the motion compensation were close in size and affected area to the no-motion case, whereas lesions obtained without the compensation were often incomplete and had larger affected areas. This approach to motion compensation could benefit extracorporeal BH and other histotripsy methods in clinical translation.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Procedimentos Cirúrgicos Robóticos , Abdome/diagnóstico por imagem , Transdutores , Ultrassonografia
9.
Artigo em Inglês | MEDLINE | ID: mdl-33052845

RESUMO

Phase aberrations induced by heterogeneities in body wall tissues introduce a shift and broadening of the high-intensity focused ultrasound (HIFU) focus, associated with decreased focal intensity. This effect is particularly detrimental for HIFU therapies that rely on shock front formation at the focus, such as boiling histotripsy (BH). In this article, an aberration correction method based on the backscattering of nonlinear ultrasound pulses from the focus is proposed and evaluated in tissue-mimicking phantoms. A custom BH system comprising a 1.5-MHz 256-element array connected to a Verasonics V1 engine was used as a pulse/echo probe. Pulse inversion imaging was implemented to visualize the second harmonic of the backscattered signal from the focus inside a phantom when propagating through an aberrating layer. Phase correction for each array element was derived from an aberration-correction method for ultrasound imaging that combines both the beamsum and the nearest neighbor correlation method and adapted it to the unique configuration of the array. The results were confirmed by replacing the target tissue with a fiber-optic hydrophone. Comparing the shock amplitude before and after phase-aberration correction showed that the majority of losses due to tissue heterogeneity were compensated, enabling fully developed shocks to be generated while focusing through aberrating layers. The feasibility of using a HIFU phased-array transducer as a pulse-echo probe in harmonic imaging mode to correct for phase aberrations was demonstrated.


Assuntos
Tratamento por Ondas de Choque Extracorpóreas , Ablação por Ultrassom Focalizado de Alta Intensidade , Imagens de Fantasmas , Transdutores , Ultrassonografia
10.
Ultrasound Med Biol ; 47(3): 603-619, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33250219

RESUMO

Infected abscesses are walled-off collections of pus and bacteria. They are a common sequela of complications in the setting of surgery, trauma, systemic infections and other disease states. Current treatment is typically limited to antibiotics with long-term catheter drainage, or surgical washout when inaccessible to percutaneous drainage or unresponsive to initial care efforts. Antibiotic resistance is also a growing concern. Although bacteria can develop drug resistance, they remain susceptible to thermal and mechanical damage. In particular, short pulses of focused ultrasound (i.e., histotripsy) generate mechanical damage through localized cavitation, representing a potential new paradigm for treating abscesses non-invasively, without the need for long-term catheterization and antibiotics. In this pilot study, boiling and cavitation histotripsy treatments were applied to subcutaneous and intramuscular abscesses developed in a novel porcine model. Ultrasound imaging was used to evaluate abscess maturity for treatment monitoring and assessment of post-treatment outcomes. Disinfection was quantified by counting bacteria colonies from samples aspirated before and after treatment. Histopathological evaluation of the abscesses was performed to identify changes resulting from histotripsy treatment and potential collateral damage. Cavitation histotripsy was more successful in reducing the bacterial load while having a smaller treatment volume compared with boiling histotripsy. The results of this pilot study suggest focused ultrasound may lead to a technology for in situ treatment of acoustically accessible abscesses.


Assuntos
Abscesso/terapia , Ablação por Ultrassom Focalizado de Alta Intensidade , Ultrassonografia de Intervenção , Animais , Modelos Animais de Doenças , Feminino , Projetos Piloto , Suínos
11.
Ultrasonics ; 103: 106066, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32028115

RESUMO

This work focuses on the evaluation of a type of piezoelectric lithotripter with similar dimensions of a commercial lithotripter and composed of either 3 or 4 large lens focused piezoelectric transducers set either in a confocal coplanar C-shape or a confocal spherical shape. Each transducer is made with a 92 mm diameter 220 kHz flat piezoelectric ceramic disc and a 3D printed acoustic lens. Both confocal setups pressure field were measured with a fiber optic hydrophone, and in vitro fragmentations of 13 mm diameter and 14 mm length cylindrical model stones were done in a 2 mm mesh basket. The acoustic characterization of the three transducers confocal setup revealed a disc shaped focal volume, with a 2.2 mm width on one axis and a 9.6 mm width on the other, and a peak positive pressure of 40.9 MPa and a peak negative pressure of -16.9 MPa, while the focus of the four transducers confocal setup was similar to a traditional narrow focus high pressure lithotripter with a focus width of 2.1 mm, and a peak positive pressure of 71.9 MPa and peak negative pressure of -24.3 MPa. Both confocal setups showed in vitro fragmentation efficiency close to a commercial electroconductive lithotripter.

12.
Nat Commun ; 10(1): 1749, 2019 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-30988298

RESUMO

Global loss of DNA methylation and CpG island (CGI) hypermethylation are key epigenomic aberrations in cancer. Global loss manifests itself in partially methylated domains (PMDs) which extend up to megabases. However, the distribution of PMDs within and between tumor types, and their effects on key functional genomic elements including CGIs are poorly defined. We comprehensively show that loss of methylation in PMDs occurs in a large fraction of the genome and represents the prime source of DNA methylation variation. PMDs are hypervariable in methylation level, size and distribution, and display elevated mutation rates. They impose intermediate DNA methylation levels incognizant of functional genomic elements including CGIs, underpinning a CGI methylator phenotype (CIMP). Repression effects on tumor suppressor genes are negligible as they are generally excluded from PMDs. The genomic distribution of PMDs reports tissue-of-origin and may represent tissue-specific silent regions which tolerate instability at the epigenetic, transcriptomic and genetic level.


Assuntos
Neoplasias da Mama/genética , Ilhas de CpG , Metilação de DNA , Epigênese Genética , Feminino , Humanos , Modelos Logísticos
13.
Artigo em Inglês | MEDLINE | ID: mdl-29733286

RESUMO

Focused transducers composed of flat piezoelectric ceramic coupled with an acoustic lens present an economical alternative to curved piezoelectric ceramics and are already in use in a variety of fields. Using a displacement/pressure (u/p) mixed finite element formulation combined with parametric level-set functions to implicitly define the boundaries between the materials and the fluid-structure interface, a method to optimize the shape of acoustic lens made of either one or multiple materials is presented. From that method, two 400 kHz focused transducers using acoustic lens were designed and built with different rapid prototyping methods, one of them made with a combination of two materials, and experimental measurements of the pressure field around the focal point are in good agreement with the presented model.

14.
Sensors (Basel) ; 18(2)2018 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-29401745

RESUMO

Carbon nanotube yarns are micron-scale fibers comprised by tens of thousands of carbon nanotubes in their cross section and exhibiting piezoresistive characteristics that can be tapped to sense strain. This paper presents the details of novel foil strain gauge sensor configurations comprising carbon nanotube yarn as the piezoresistive sensing element. The foil strain gauge sensors are designed using the results of parametric studies that maximize the sensitivity of the sensors to mechanical loading. The fabrication details of the strain gauge sensors that exhibit the highest sensitivity, based on the modeling results, are described including the materials and procedures used in the first prototypes. Details of the calibration of the foil strain gauge sensors are also provided and discussed in the context of their electromechanical characterization when bonded to metallic specimens. This characterization included studying their response under monotonic and cyclic mechanical loading. It was shown that these foil strain gauge sensors comprising carbon nanotube yarn are sensitive enough to capture strain and can replicate the loading and unloading cycles. It was also observed that the loading rate affects their piezoresistive response and that the gauge factors were all above one order of magnitude higher than those of typical metallic foil strain gauges. Based on these calibration results on the initial sensor configurations, new foil strain gauge configurations will be designed and fabricated, to increase the strain gauge factors even more.

15.
Breast Cancer Res ; 19(1): 98, 2017 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-28830573

RESUMO

BACKGROUND: Genome-wide association studies (GWAS) have to date identified 94 genetic variants (single nucleotide polymorphisms (SNPs)) associated with risk of developing breast cancer. A score based on the combined effect of the 94 risk alleles can be calculated to measure the global risk of breast cancer. We aimed to test the hypothesis that the 94-SNP-based risk score is associated with clinico-pathological characteristics, breast cancer subtypes and outcomes in early breast cancer. METHODS: A 94-SNP risk score was calculated in 8703 patients in the PHARE and SIGNAL prospective case cohorts. This score is the total number of inherited risk alleles based on 94 selected SNPs. Clinical data and outcomes were prospectively registered. Genotyping was obtained from a GWAS. RESULTS: The median 94-SNP risk score in 8703 patients with early breast cancer was 77.5 (range: 58.1-97.6). The risk score was not associated with usual prognostic and predictive factors (age; tumor, node, metastasis (TNM) status; Scarff-Bloom-Richardson grade; inflammatory features; estrogen receptor status; progesterone receptor status; human epidermal growth factor receptor 2 (HER2) status) and did not correlate with breast cancer subtypes. The 94-SNP risk score did not predict outcomes represented by overall survival or disease-free survival. CONCLUSIONS: In a prospective case cohort of 8703 patients, a risk score based on 94 SNPs was not associated with breast cancer characteristics, cancer subtypes, or patients' outcomes. If we hypothesize that prognosis and subtypes of breast cancer are determined by constitutional genetic factors, our results suggest that a score based on breast cancer risk-associated SNPs is not associated with prognosis. TRIAL REGISTRATION: PHARE cohort: NCT00381901 , Sept. 26, 2006 - SIGNAL cohort: INCa RECF1098, Jan. 28, 2009.


Assuntos
Neoplasias da Mama/genética , Neoplasias da Mama/mortalidade , Estudos de Associação Genética , Predisposição Genética para Doença , Polimorfismo de Nucleotídeo Único , Adulto , Idoso , Idoso de 80 Anos ou mais , Alelos , Biomarcadores Tumorais , Neoplasias da Mama/patologia , Ensaios Clínicos Fase III como Assunto , Estudos de Coortes , Feminino , Genótipo , Humanos , Pessoa de Meia-Idade , Gradação de Tumores , Metástase Neoplásica , Estadiamento de Neoplasias , Prognóstico , Ensaios Clínicos Controlados Aleatórios como Assunto , Análise de Sobrevida , Carga Tumoral , Adulto Jovem
16.
J Dairy Sci ; 100(10): 8197-8204, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28822546

RESUMO

Claw lesions are one of the most important health issues in dairy cattle. Although the frequency of claw lesions depends greatly on herd management, the frequency can be lowered through genetic selection. A genetic evaluation could be developed based on trimming records collected by claw trimmers; however, not all cows present in a herd are usually selected by the breeder to be trimmed. The objectives of this study were to investigate the importance of the preselection of cows for trimming, to account for this preselection, and to estimate genetic parameters of claw health traits. The final data set contained 25,511 trimming records of French Holstein cows. Analyzed claw lesion traits were digital dermatitis, heel horn erosion, interdigital hyperplasia, sole hemorrhage circumscribed, sole hemorrhage diffused, sole ulcer, and white line fissure. All traits were analyzed as binary traits in a multitrait linear animal model. Three scenarios were considered: including only trimmed cows in a 7-trait model (scenario 1); or trimmed cows and contemporary cows not trimmed but present at the time of a visit (considering that nontrimmed cows were healthy) in a 7-trait model (scenario 2); or trimmed cows and contemporary cows not trimmed but present at the time of a visit (considering lesion records for trimmed cows only), in an 8-trait model, including a 0/1 trimming status trait (scenario 3). For scenario 3, heritability estimates ranged from 0.02 to 0.09 on the observed scale. Genetic correlations clearly revealed 2 groups of traits (digital dermatitis, heel horn erosion, and interdigital hyperplasia on the one hand, and sole hemorrhage circumscribed, sole hemorrhage diffused, sole ulcer, and white line fissure on the other hand). Heritabilities on the underlying scale did not vary much depending on the scenario: the effect of the preselection of cows for trimming on the estimation of heritabilities appeared to be negligible. However, including untrimmed cows as healthy caused bias in the estimation of genetic correlations. The use of a trimming status trait to account for preselection appears promising, as it allows consideration of the exhaustive population of cows present at the time a trimmer visited a farm without causing bias in genetic parameters.


Assuntos
Criação de Animais Domésticos/estatística & dados numéricos , Doenças dos Bovinos/epidemiologia , Dermatite Digital/epidemiologia , Doenças do Pé/veterinária , Casco e Garras , Seleção Genética , Animais , Bovinos , Doenças dos Bovinos/prevenção & controle , Dermatite Digital/prevenção & controle , Feminino , Doenças do Pé/epidemiologia , Doenças do Pé/prevenção & controle , Fenótipo
17.
NPJ Breast Cancer ; 3: 4, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28649644

RESUMO

Human epidermal growth factor receptor 2-positive breast cancer is a subtype of interest regarding its outcome and the impressive impact of human epidermal growth factor receptor 2 targeted therapy. Constitutional variants may be involved in the aetiology of human epidermal growth factor receptor 2-positive breast cancer, and we propose a case-case study to test the hypothesis that single nucleotide polymorphisms may be associated with human epidermal growth factor receptor 2 status. A Genome-Wide Association Study was used in a cohort of 9836 patients from the SIGNAL/PHARE study (NCT00381901-RECF1098). The main goal was to identify variants specifically related to human epidermal growth factor receptor 2-positive breast cancer. A two-staged genotyping strategy was carried out to cover as large a proportion of the genome as possible. All subjects were genotyped using the Illumina HumanCore Exome chip set. Principal Components Analysis and k-means were then used to characterize the ancestry of the participants. A random sample of subjects from the main "European" cluster was genotyped with the Omni5 chip set. These data were then used to impute missing genotypes from the remaining subjects genotyped only using the HumanCore Exome array. From the 9836 patients, a total of 8703 cases including 3230 patients with human epidermal growth factor receptor 2-positive breast cancer were analyzed. Despite having 80% power to detect an odds ratio of 1.23 in this population, no variant achieved genome-wide significance for association with the occurrence of human epidermal growth factor receptor 2-positive breast cancer vs. any other subtype of breast tumour. Our study was unable to identify constitutional polymorphisms that are strongly associated with human epidermal growth factor receptor 2-positive status among breast cancer patients.

18.
Artigo em Inglês | MEDLINE | ID: mdl-28252394

RESUMO

A linear acoustic levitation transportation system based on a ring-type vibrator is presented. The system is composed by two 21-kHz Langevin transducers connected to a ring-shaped structure formed by two semicircular sections and two flat plates. In this system, a flexural standing wave is generated along the ring structure, producing an acoustic standing wave between the vibrating ring and a plane reflector located at a distance of approximately a half wavelength from the ring. The acoustic standing wave in air has a series of pressure nodes, where small particles can be levitated and transported. The ring-type transportation system was designed and analyzed by using the finite element method. Additionally, a prototype was built and the acoustic levitation and transport of a small polystyrene particle was demonstrated.

19.
Oncotarget ; 7(47): 77358-77364, 2016 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-27764800

RESUMO

Genetic polymorphisms are associated with breast cancer risk. Clinical and epidemiological observations suggest that clinical characteristics of breast cancer, such as estrogen receptor or HER2 status, are also influenced by hereditary factors. To identify genetic variants associated with pathological characteristics of breast cancer patients, a Genome Wide Association Study was performed in a cohort of 9365 women from the French nationwide SIGNAL/PHARE studies (NCT00381901/RECF1098). Strong association between the FGFR2 locus and ER status of breast cancer patients was observed (ER-positive n=6211, ER-negative n=2516; rs3135718 OR=1.34 p=5.46×10-12). This association was limited to patients with HER2-negative tumors (ER-positive n=4267, ER-negative n=1185; rs3135724 OR=1.85 p=1.16×10-11). The FGFR2 locus is known to be associated with breast cancer risk. This study provides sound evidence for an association between variants in the FGFR2 locus and ER status among breast cancer patients, particularly among patients with HER2-negative disease. This refinement of the association between FGFR2 variants and ER-status to HER2-negative disease provides novel insight to potential biological and clinical influence of genetic polymorphisms on breast tumors.


Assuntos
Biomarcadores Tumorais , Neoplasias da Mama/genética , Estudo de Associação Genômica Ampla , Receptor ErbB-2/genética , Receptor Tipo 2 de Fator de Crescimento de Fibroblastos/genética , Ensaios Clínicos Fase III como Assunto , Estudos de Coortes , Feminino , Predisposição Genética para Doença , Humanos , Polimorfismo de Nucleotídeo Único , Ensaios Clínicos Controlados Aleatórios como Assunto , Receptores de Estrogênio/genética
20.
Nat Commun ; 7: 12910, 2016 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-27666519

RESUMO

A recent comprehensive whole genome analysis of a large breast cancer cohort was used to link known and novel drivers and substitution signatures to the transcriptome of 266 cases. Here, we validate that subtype-specific aberrations show concordant expression changes for, for example, TP53, PIK3CA, PTEN, CCND1 and CDH1. We find that CCND3 expression levels do not correlate with amplification, while increased GATA3 expression in mutant GATA3 cancers suggests GATA3 is an oncogene. In luminal cases the total number of substitutions, irrespective of type, associates with cell cycle gene expression and adverse outcome, whereas the number of mutations of signatures 3 and 13 associates with immune-response specific gene expression, increased numbers of tumour-infiltrating lymphocytes and better outcome. Thus, while earlier reports imply that the sheer number of somatic aberrations could trigger an immune-response, our data suggests that substitutions of a particular type are more effective in doing so than others.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...