Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Am J Cardiol ; 220: 102-110, 2024 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-38432334

RESUMO

Proximal radial artery (PRA) access for cardiac catheterization is safe but can jeopardize subsequent use of the artery because of occlusion. Distal radial artery (DRA) access in the anatomical snuffbox preserves the RA but safety and potential detrimental effects on hand function are unknown. We aimed to assess hand function and complications after DRA and PRA. In this single-center trial, 300 patients were randomly allocated 1:1 to cardiac catheterization through DRA or PRA. The primary end point of change in hand function from baseline to 1 year was a composite of the Quick Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire, hand grip test, and thumb-forefinger pinch test. The secondary end points included access feasibility and complications. Of 216 patients with 1-year completed follow-up, 112 were randomly allocated to DRA and 104 to PRA, with balanced demographics and procedural characteristics. Both groups had similar access site bleeding rates (DRA 0% vs PRA 1.4%, p = 0.25). Radial artery occlusion occurred in 1 PRA patient versus 2 in DRA. There was no significant difference in change of hand function, median (interquartile range) hand grip (DRA 0.7 [-3 to 4.5] vs PRA 1.3 [-2 to 4.3] kg, p = 0.57), pinch grip (DRA -0.1 [-1.1 to 1] vs PRA -0.3 [-1 to 0.7] kg, p = 0.66), and Quick DASH (DRA 0 [-6.6 to 2.3] vs PRA 0 [-4.6 to 2.9] points, p = 0.58). The composite of hand function was comparable between PRA and DRA. In conclusion, DRA is a safe strategy for cardiac catheterization, with a low complication rate. Compared with PRA, there is no increased risk of hand dysfunction or radial artery occlusion at 1 year.


Assuntos
Cateterismo Cardíaco , Artéria Radial , Humanos , Masculino , Feminino , Cateterismo Cardíaco/métodos , Pessoa de Meia-Idade , Idoso , Força da Mão/fisiologia , Seguimentos , Fatores de Tempo
2.
Proc (Bayl Univ Med Cent) ; 37(2): 218-226, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38343489

RESUMO

Background: In March 2022, a COVID-19 outbreak disrupted the global supply of iodine contrast media (ICM). Healthcare systems implemented contrast-saving strategies to maintain their remaining ICM supplies. This study sought to determine the impact of contrast shortage on the incidence of contrast-associated acute kidney injury (CA-AKI). Methods: This was a retrospective study of 265 patients undergoing 278 percutaneous coronary interventions (PCI) during 4-month periods prior to (9/1/2021 to 12/31/2021) and during (5/1/2022 to 8/31/2022) contrast shortage at a single center. The primary endpoint was the incidence of CA-AKI between study periods. Results: A total of 148 and 130 PCIs were performed before and during contrast shortage, respectively. The incidence of CA-AKI significantly decreased from 11.5% to 4.6% during contrast shortage (P = 0.04). During the shortage, average contrast volume per PCI was significantly lower (123 ± 62 mL vs 88 ± 46 mL, P < 0.001), while coronary imaging was significantly higher (34.3% vs 50%, P = 0.009) compared to preshortage. All-cause mortality at discharge was comparable between study periods (2.8% vs 3.3%, respectively; P = 0.90). Conclusion: The scarcity of ICM for PCI procedures in this single-center experience was associated with a significant increase in the utilization of intravascular imaging and a significant reduction in CA-AKI.

3.
J Am Heart Assoc ; 12(21): e030774, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37889176

RESUMO

Background Proximal radial artery (pRA) access for cardiac catheterization is safe but can jeopardize subsequent use of the artery because of occlusion. Distal radial artery (dRA) access in the anatomical snuffbox preserves the radial artery, but safety and potential detrimental effects on hand function are unknown. Methods and Results In the DIPRA (Distal Versus Proximal Radial Artery Access for Cardiac Catheterization and Intervention) study, a single-center trial, 300 patients were randomized 1:1 to cardiac catheterization through dRA or pRA. The primary end point of change in hand function from baseline to 30 days was a composite of the QuickDASH (Quick Disabilities of the Arm, Shoulder and Hand) questionnaire, hand-grip test, and thumb forefinger pinch test. Secondary end points included access feasibility and complications; 254 of 300 patients completed follow-up at 30 days; of these, 128 were randomized to dRA and 126 to pRA with balanced demographic and procedural characteristics. Both groups had similar rates of access site bleeding (dRA 0% versus pRA 1.4%; P=0.25). Six patients with dRA failed access compared with 2 patients with pRA. Radial artery occlusion occurred in 2 pRA versus none in dRA. There were no significant differences in change in hand function, median hand-grip (dRA 0 [-3.2, 3.3] versus pRA 0.7 [-2.3, 3.3] kg; P=0.21), pinch-grip (dRA -0.3 [-1.2, 0.5] versus pRA 0 [-0.9, 0.9] kg; P=0.09), and QuickDASH (dRA 0 [-4.6, 2.3] versus pRA 0 [-4.6, 2.3] points, P=0.96). There was no significant difference in the composite of hand function between pRA and dRA. Conclusions dRA is a safe strategy for cardiac catheterization with a low complication rate. Compared with pRA, there is no increased risk of hand dysfunction at 30 days. Registration URL: https://www.ClinicalTrials.gov. Unique identifier: NCT04318990.


Assuntos
Arteriopatias Oclusivas , Intervenção Coronária Percutânea , Humanos , Artéria Radial , Punho , Cateterismo Cardíaco/efeitos adversos , Angiografia Coronária/métodos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
4.
Cardiovasc Revasc Med ; 35: 104-109, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33926835

RESUMO

BACKGROUND: Radial artery (RA) catheterization is the access of choice over femoral artery access for most interventional vascular procedures given its safety and faster patient recovery. There has been growing interest in distal radial artery (dRA) access as an alternative to the conventional proximal radial artery (pRA) access. Preserving the RA is important which serves as a potential conduit for future coronary artery bypass surgery, dialysis conduit or preserve the artery for future cardiovascular procedures. The dRA runs in close proximity to the radial nerve, which raises the concern of potential detrimental effects on hand function. STUDY DESIGN: The Distal versus Proximal Radial Artery Access for cardiac catheterization and intervention (DIPRA) trial is a prospective, randomized, parallel-controlled, open-label, single center study evaluating the outcomes of hand function and effectiveness of dRA compared to pRA access in patients undergoing cardiac catheterization. The eligible subjects will be randomized to dRA and pRA access in a (1:1) fashion. The primary end point is an evaluation of hand function at one and twelve months follow-up. Secondary end points include rates of access site hematoma, access site bleeding, other vascular access complications, arterial access success rate, and RA occlusion at one and twelve months follow up. CONCLUSION: Effects of dRA on hand function remains unknown and it's use questionable in the presence of a widely accepted pRA. DIPRA trial is designed to determine the safety and effectiveness of dRA for diagnostic and interventional cardiovascular procedures compared to the standard of care pRA.


Assuntos
Cateterismo Periférico , Intervenção Coronária Percutânea , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Cateterismo Periférico/efeitos adversos , Angiografia Coronária/métodos , Ponte de Artéria Coronária , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Artéria Radial/diagnóstico por imagem , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA