1.
Langmuir ; 39(7): 2676-2691, 2023 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-36757323

RESUMO

The effect of lipid composition on models of the inner leaflet of mammalian cell membranes has been investigated. Grazing incidence X-ray diffraction and X-ray and neutron reflectivity have been used to characterize lipid packing and solvation, while electrochemical and infrared spectroscopic methods have been employed to probe phase behavior in an applied electric field. Introducing a small quantity of the anionic lipid dimyristoylphosphatidylserine (DMPS) into bilayers of zwitterionic dimyristoylphosphatidylethanolamine (DMPE) results in a significant change in the bilayer response to an applied field: the tilt of the hydrocarbon chains increases before returning to the original tilt angle on detachment of the bilayer. Equimolar mixtures, with slightly closer chain packing, exhibit a similar but weaker response. The latter also tend to incorporate more solvent during this electrochemical phase transition, at levels similar to those of pure DMPS. Reflectivity measurements reveal greater solvation of lipid layers for DMPS > 30 mol %, matching the greater propensity for DMPS-rich bilayers to incorporate water. Taken together, the data indicate that the range of 10-35 mol % DMPS provides optimum bilayer properties (in flexibility and function as a barrier), which may explain why the DMPS content of cell membranes tends to be found within this range.


Assuntos
Bicamadas Lipídicas , Mamíferos , Animais , Bicamadas Lipídicas/química , Membrana Celular , Espectrofotometria Infravermelho , Membranas , Difração de Raios X
2.
J AOAC Int ; 104(4): 1036-1048, 2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-33528010

RESUMO

BACKGROUND: AOAC Method 2015.06 is a Final Action Official MethodSM for the determination of 12 elements (Na, Mg, P, K, Ca, Cr, Mn, Fe, Cu, Zn, Se, and Mo) in infant formula and adult nutritional products, based on inductively coupled plasma (ICP)-MS. Currently, its scope does not include certain kinds of formulations used in India. The method would likely be used more in Indian laboratories if its performance were characterized on Indian matrixes. OBJECTIVE: In this study we describe a typical single-laboratory validation (SLV) exercise designed to characterize the precision and accuracy of AOAC Method 2015.06 for common Indian nutritional matrixes so that the scope of the method can be extended to include them. METHOD: Six matrixes specific to the Indian market were carried through an SLV and the Standard Method Performance Requirements (SMPRs®) previously published for this method were used to evaluate the results. RESULTS: The method demonstrated typical repeatability (<5% RSD), and intermediate precision (5-8% RSD) on the Indian matrixes, with very few exceptions. Accuracy was demonstrated by overspike recoveries in the range of 90-110% over 3 days for the Indian matrixes, as well as excellent agreement with previously published results for three additional matrixes tested. Some of the new Indian matrixes required alternate sample preparation procedures versus the usual reconstitution prescribed by the SMPRs. CONCLUSIONS: The SLV results showed that AOAC Method 2015.06 can be extended to include these Indian matrices. HIGHLIGHTS: The two special sample preparation procedures can now be considered validated.


Assuntos
Fórmulas Infantis , Laboratórios , Adulto , Criança , Alimentos Formulados , Humanos , Índia , Lactente
3.
PLoS One ; 14(6): e0218251, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31194810

RESUMO

In tasks that demand rapid performance, actions must be executed as efficiently as possible. Theories of expert motor performance such as the motor chunking framework suggest that efficiency is supported by automatization, where many serial actions are automatized into smaller chunks, or groups of commonly co-occuring actions. We use the fast-paced, professional eSport StarCraft 2 as a test case of the explanatory power of the motor chunking framework and assess the importance of chunks in explaining expert performance. To do so, we test three predictions motivated by a simple motor chunking framework. (1) StarCraft 2 players should exhibit an increasing number of chunks with expertise. (2) The proportion of actions falling within a chunk should increase with skill. (3) Chunks should be faster than non-chunks containing the same atomic behaviours. Although our findings support the existence of chunks, they also highlight two problems for existing accounts of rapid motor execution and expert performance. First, while better players do use more chunks, the proportion of actions within a chunks is stable across expertise and expert sequences are generally more varied (the diversity problem). Secondly, chunks, which are supposed to enjoy the most extreme automatization, appear to save little or no time overall (the time savings problem). Instead, the most parsimonious description of our latency analysis is that players become faster overall regardless of chunking.


Assuntos
Comportamento , Modelos Teóricos , Humanos , Análise e Desempenho de Tarefas
4.
J AOAC Int ; 101(2): 536-561, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29151407

RESUMO

AOAC Final Action Official MethodSM 2015.06 "Minerals and Trace Elements in Milk, Milk Products, Infant Formula and Adult/Pediatric Nutritional Formula, ICP-MS Method" was collaboratively studied. Note that "milk, milk products" has now been added to the title of the Final Action method because whole milk and several dairy ingredients were successfully incorporated into the collaborative study for the purpose of developing an International Organization for Standardization/International Dairy Federation standard (ISO/DIS 21424; in progress). The method determines sodium, magnesium, phosphorus, potassium, calcium, iron, manganese, zinc, copper, chromium, molybdenum, and selenium by inductively coupled plasma (ICP)-MS after microwave digestion. Ten laboratories participated in the study, and data from five different model ICP-MS units were represented. Thirteen products, five placebo products, and six dairy samples were tested as blind duplicates in this study, along with a standard reference material, for a total 50 samples. The overall repeatability and reproducibility for all samples met Standard Method Performance Requirements put forth by the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals, with a few exceptions. Comparisons are made to ICP-atomic emission data from a collaborative study of AOAC Official Method 2011.14 carried out concurrently on these same samples.


Assuntos
Laticínios/análise , Fórmulas Infantis/análise , Leite/química , Minerais/análise , Oligoelementos/análise , Adulto , Animais , Criança , Humanos , Lactente , Espectrometria de Massas/métodos , Metais/análise , Fósforo/análise , Reprodutibilidade dos Testes , Selênio/análise , Espectrofotometria Atômica/métodos
5.
Top Cogn Sci ; 9(2): 467-484, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28176483

RESUMO

Many theories of complex cognitive-motor skill learning are built on the notion that basic cognitive processes group actions into easy-to-perform sequences. The present work examines predictions derived from laboratory-based studies of motor chunking and motor preparation using data collected from the real-time strategy video game StarCraft 2. We examined 996,163 action sequences in the telemetry data of 3,317 players across seven levels of skill. As predicted, the latency to the first action (thought to be the beginning of a chunked sequence) is delayed relative to the other actions in the group. Other predictions, inspired by the memory drum theory of Henry and Rogers, received only weak support.


Assuntos
Destreza Motora , Jogos de Vídeo , Cognição , Humanos , Memória , Telemetria
6.
J AOAC Int ; 100(2): 522-531, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28118572

RESUMO

A limited single-laboratory validation (SLV) was conducted in the authors' laboratory to investigate the performance of AOAC Official MethodsSM 2011.19 Determination of Chromium (Cr), Selenium (Se), and Molybdenum (Mo) in Infant Formula and Adult Nutritional Products by Inductively Coupled Plasma/Mass Spectrometry and 2015.06 Determination of Minerals and Trace Elements in Infant Formula and Adult/Pediatric Nutritional Formula by Inductively Coupled Plasma/Mass Spectrometry at analyte levels below the practical LOQs (PLOQs) already published for these Final Action Official Methods. This work was needed to verify that the actual LOQs were below the minimum requirements for minerals in infant formula as given in CODEX STAN 72 (1981). Linearity studies at low levels were conducted as well as the analysis of blanks over multiple days to establish the LOQs (as opposed to PLOQs) for these nutrients. Several placebo matrixes from the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) program were tested over multiple days at two different sample sizes to quantitate the effect of doubling the sample size given in the original publications. The SLV results indicate that both methods can meet the Codex minimum requirements as-is, without modification of the methods, albeit with a relaxation of the stringent precision criteria originally established for these methods by SPIFAN. Precision can be improved by doubling the sample size, but this step is not necessary to use the method for its intended purpose. A concurrent collaborative study of Method 2015.06 showed that the RSDR obtained across eight laboratories for several infant formula placebos containing mineral concentrations between the PLOQ and LOQ were indeed worse than SPIFAN expectations, but reasonable Horwitz ratios (HorRat) were nonetheless obtained for these analytes.


Assuntos
Fórmulas Infantis/análise , Cromo/análise , Humanos , Fórmulas Infantis/normas , Metais Alcalinos/análise , Metais Alcalinoterrosos/análise , Molibdênio/análise , Fósforo/análise , Selênio/análise
7.
J AOAC Int ; 98(6): 1702-10, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26651583

RESUMO

AOAC First Action Method 2011.19: Chromium, Selenium, and Molybdenum in Infant Formula and Adult Nutritional Products, was collaboratively studied. This method uses microwave digestion of samples with nitric acid, hydrogen peroxide, and internal standard followed by simultaneous detection of the elements by an inductively coupled plasma (ICP)/MS instrument equipped with a collision/reaction cell. During this collaborative study, nine laboratories from four different countries, using seven different models of ICP/MS instruments, analyzed blind duplicates of seven infant, pediatric, and adult nutritional formulas. One laboratory's set of data was rejected in its entirety. The method demonstrated acceptable repeatability and reproducibility and met the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) Standard Method Performance Requirements (SMPRs®) for almost all of the matrixes analyzed. The Cr, Mo, and Se SPIFAN requirement for repeatability was ≤5% RSD. The SMPR called for a reproducibility of ≤15% RSD for products with ultratrace element concentrations above the targeted LOQ of 20 µg/kg Cr/Mo and 10 µg/kg Se (as ready-to-feed). During this collaborative study, RSDr ranged from 1.0 to 7.0% and RSDR ranged from 2.5 to 13.4% across all three ultratrace elements.


Assuntos
Cromo/análise , Alimentos Formulados/análise , Fórmulas Infantis/química , Molibdênio/análise , Selênio/análise , Espectrofotometria Atômica/métodos , Adulto , Comportamento Cooperativo , Humanos , Lactente , Reprodutibilidade dos Testes
8.
J AOAC Int ; 98(6): 1711-20, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26651584

RESUMO

A method for determination of 12 minerals and trace elements (Na, Mg, P, K, Ca, Cr, Mn, Fe, Cu, Zn, Se, and Mo) in infant formula and adult/ pediatric nutritional formula was developed and evaluated in a single-laboratory validation. Some additional reproducibility data were obtained from a small interlaboratory study. The method involves microwave digestion of the sample followed by inductively coupled plasma/MS and uses Ge and Te as internal standards. The method is an extension of Official Method(SM) 2011.19 and was compared to AOAC Standard Method Performance Requirements (SMPRs®) 2011.009 and 2014.004 developed by the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN). Repeatability precision for the 12 elements in 11 SPIFAN matrixes and National Institute of Standards and Technology Standard Reference Material (SRM) 1849a was <5%, meeting the SMPR criterion for repeatability. Intermediate reproducibility (8 days, two analysts, two instruments) in the 11 SPIFAN matrixes was <5% for nine (Na, Mg, P, K, Mn, Fe, Cu, Zn, Se) of the 12 elements in all 11 matrixes. The mean reproducibility across 6-7 laboratories and seven SPIFAN matrixes ranged from 2.5% for Cu to 7.1% for P. Recovery from spiked matrixes varied from 90.1 to 109%, and accuracy of determination using SRM 1849a ranged from 96.2 to 107.7%, meeting the requirement of 90-110% recovery/accuracy.


Assuntos
Alimentos Formulados/análise , Fórmulas Infantis/química , Minerais/análise , Espectrofotometria Atômica/métodos , Oligoelementos/análise , Adulto , Humanos , Lactente , Limite de Detecção , Reprodutibilidade dos Testes
9.
J AOAC Int ; 98(5): 1395-406, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26110467

RESUMO

A single-laboratory validation (SLV) has been performed for a method that simultaneously determines choline and carnitine in nutritional products by ultra performance LC (UPLC)/MS/MS. All 11 matrixes from the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) were tested. Depending on the sample preparation, either the added (free, with a water dilution and filtering) or total (after microwave digestion at 120°C in nitric acid and subsequent neutralization with ammonia) species can be detected. For nonmilk containing products, the total carnitine is almost always equal to the free carnitine. A substantial difference was noted between free and total choline in all products. All Standard Method Performance Requirements for carnitine and choline have been met. This report summarizes the material sent to the AOAC Expert Review Panel for SPIFAN nutrient methods for the review of this method, as well as some additional data from an internal validation. The method was granted AOAC First Action status for carnitine in 2014 (2014.04), but the choline data are also being presented. A comparison of choline results to those from other AOAC methods is given.


Assuntos
Carnitina/análise , Colina/análise , Cromatografia Líquida de Alta Pressão/normas , Alimentos Formulados/análise , Espectrometria de Massas em Tandem/normas , Adulto , Amônia/química , Criança , Guias como Assunto , Humanos , Hidrólise , Interações Hidrofóbicas e Hidrofílicas , Lactente , Limite de Detecção , Ácido Nítrico/química , Pós , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
10.
PLoS One ; 9(4): e94215, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24718593

RESUMO

Typically studies of the effects of aging on cognitive-motor performance emphasize changes in elderly populations. Although some research is directly concerned with when age-related decline actually begins, studies are often based on relatively simple reaction time tasks, making it impossible to gauge the impact of experience in compensating for this decline in a real world task. The present study investigates age-related changes in cognitive motor performance through adolescence and adulthood in a complex real world task, the real-time strategy video game StarCraft 2. In this paper we analyze the influence of age on performance using a dataset of 3,305 players, aged 16-44, collected by Thompson, Blair, Chen & Henrey [1]. Using a piecewise regression analysis, we find that age-related slowing of within-game, self-initiated response times begins at 24 years of age. We find no evidence for the common belief expertise should attenuate domain-specific cognitive decline. Domain-specific response time declines appear to persist regardless of skill level. A second analysis of dual-task performance finds no evidence of a corresponding age-related decline. Finally, an exploratory analyses of other age-related differences suggests that older participants may have been compensating for a loss in response speed through the use of game mechanics that reduce cognitive load.


Assuntos
Envelhecimento/fisiologia , Cognição/fisiologia , Destreza Motora/fisiologia , Desempenho Psicomotor/fisiologia , Tempo de Reação/fisiologia , Jogos de Vídeo , Adulto Jovem/fisiologia , Adolescente , Adulto , Envelhecimento/psicologia , Sistemas Computacionais , Humanos , Pessoa de Meia-Idade , Jogos de Vídeo/psicologia , Adulto Jovem/psicologia
11.
PLoS One ; 8(9): e75129, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24058656

RESUMO

Cognitive science has long shown interest in expertise, in part because prediction and control of expert development would have immense practical value. Most studies in this area investigate expertise by comparing experts with novices. The reliance on contrastive samples in studies of human expertise only yields deep insight into development where differences are important throughout skill acquisition. This reliance may be pernicious where the predictive importance of variables is not constant across levels of expertise. Before the development of sophisticated machine learning tools for data mining larger samples, and indeed, before such samples were available, it was difficult to test the implicit assumption of static variable importance in expertise development. To investigate if this reliance may have imposed critical restrictions on the understanding of complex skill development, we adopted an alternative method, the online acquisition of telemetry data from a common daily activity for many: video gaming. Using measures of cognitive-motor, attentional, and perceptual processing extracted from game data from 3360 Real-Time Strategy players at 7 different levels of expertise, we identified 12 variables relevant to expertise. We show that the static variable importance assumption is false--the predictive importance of these variables shifted as the levels of expertise increased--and, at least in our dataset, that a contrastive approach would have been misleading. The finding that variable importance is not static across levels of expertise suggests that large, diverse datasets of sustained cognitive-motor performance are crucial for an understanding of expertise in real-world contexts. We also identify plausible cognitive markers of expertise.


Assuntos
Aprendizagem/fisiologia , Desempenho Psicomotor/fisiologia , Telemetria/métodos , Jogos de Vídeo , Feminino , Humanos , Masculino , Telemetria/instrumentação
12.
J AOAC Int ; 96(4): 798-801, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24000755

RESUMO

After an assessment of data generated from a single-laboratory validation study published in the Journal of AOAC INTERNATIONAL 95, 169-176 (2012), a method for determining the total level of iodine in infant formula and nutritional products was presented for consideration for adoption by AOAC during the AOAC Annual Meeting held September 30-October 3, 2012 in Las Vegas, NV. An Expert Review Panel on Infant Formula and Adult Nutritionals concluded that the method met the established standard method performance requirements, and approved the method as AOAC Official First Action. The method involves digestion of the sample with nitric acid in a closed vessel microwave oven, followed by determination by inductively coupled plasma/MS using tellurium as the internal standard. The method LOQ for total iodine was 1.5 microg/100 g, but a practical LOQ was used at 5 microg/100 g total iodine. The analytical range of the method was 5-100 microg/100 g total iodine. The recoveries from 15 spiked nutritional products ranged from 90 to 105%.


Assuntos
Fórmulas Infantis/química , Iodo/análise , Espectrofotometria Atômica/métodos , Espectrometria de Massas/métodos , Controle de Qualidade
13.
J AOAC Int ; 95(3): 588-98, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22816248

RESUMO

An inductively coupled plasma/MS method was developed for the simultaneous determination of Cr, Se, and Mo in infant formula and other nutritional products. All samples were digested using a closed vessel microwave oven system, together with Ni and Te internal standards. The practical quantitation limits for Cr, Se, and Mo were 0.4, 0.2, and 0.4 ng/mL, respectively; dilution factors were 250 for powders and 50 for liquids. The Cr, Se, and Mo concentrations in 10 nutritional products were within specification limits; within-day and day-to-day (6 independent days) precision values were <5% RSD. For two control samples, the observed precision was < or = 2% RSD over 10 independent days. Cr, Se, and Mo results were within the certified limits in three National Institute of Standards and Technology standard reference materials. The average sample spike recoveries for 10 nutritional products ranged from 93 to 107%. Robustness studies showed a minimal effect from concomitant easily ionized element concentrations. However, the choice of internal standard and matrix-matching carbon content were critical to obtaining accurate Se results. All indications are that this method would be a suitable candidate as a global reference method for the determination of these trace elements in infant formula, adult nutritionals, and other nutritional


Assuntos
Cromo/análise , Fórmulas Infantis/química , Espectrometria de Massas/métodos , Molibdênio/análise , Selênio/análise , Limite de Detecção
14.
J AOAC Int ; 95(1): 169-76, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22468356

RESUMO

A single-laboratory validation by inductively coupled plasma-mass spectrometry was developed for the determination total iodine (m/z 127) in infant formula and adult nutritional products. All samples were digested in nitric acid using a closed vessel microwave oven system; Te (m/z 130) was used as an internal standard. To prevent loss of iodine, ammonium hydroxide solution was added to the samples immediately after digestion. The method quantitation limit for total iodine was 0.3 ng/mL, but a practical LOQ was used at 1.0 ng/mL, a concentration at which there was a negligible bias due to nonlinearity. The total iodine concentrations (112-1900 ng/g) in 14 out of 15 nutritional products were within specification limits. Within-day and day-to-day (6 independent days) precision values were < 10% RSD. The observed precision for the overall mean (18 independent days) of a control sample was approximately 4% RSD. In two National Institute of Standards and Technology standard reference materials, total iodine results were within certified limits. Sample spike recoveries for all 15 nutritional products were 92-105%. The data show that a conventional microwave oven digestion procedure can be used to prepare samples for iodine determination. Therefore, this technique is very compatible with other methods being proposed as modern official methods for the analysis of minerals in nutritional products.


Assuntos
Alimentos Formulados/análise , Alimentos Infantis/análise , Iodo/análise , Carboidratos da Dieta/análise , Gorduras na Dieta/análise , Proteínas Alimentares/análise , Humanos , Indicadores e Reagentes , Lactente , Limite de Detecção , Espectrometria de Massas/métodos , Micro-Ondas , Ácido Nítrico/química , Pós , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Software , Soluções
15.
J AOAC Int ; 94(4): 1240-52, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21919358

RESUMO

An inductively coupled plasma/MS method was developed for the simultaneous determination of Cr, Se, and Mo in infant formulas and other nutritional products. All samples were digested using a closed vessel microwave oven system, together with Ni and Te internal standards. The practical quantitation limits for Cr, Se, and Mo were 0.4, 0.2, and 0.4 ng/mL, respectively; dilution factors were 250 for powders and 50 for liquids. The Cr, Se, and Mo concentrations in 10 nutritional products were within specification limits, and within-day and day-to-day (6 independent days) precision values were <5% RSD. For two control samples, the observed precision was < or = 2% RSD over 10 independent days. In three National Institute of Standards and Technology standard reference materials, Cr, Se, and Mo results were within the certified limits. The average sample spike recoveries for 10 nutritional products ranged from 93 to 107%. Robustness studies showed a minimal effect from concomitant easily ionized element concentrations. However, the choice of internal standard and matrix matching carbon content were critical to obtaining accurate Se results. All indications are that this method would be a suitable candidate as a global reference method for the determination of these trace elements in nutritional products.


Assuntos
Cromo/química , Alimentos Formulados/análise , Molibdênio/química , Selênio/química , Espectrofotometria Atômica/métodos , Análise de Alimentos/métodos , Humanos , Lactente , Reprodutibilidade dos Testes , Sensibilidade e Especificidade