1.
PLoS One ; 17(7): e0271349, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35816503

RESUMO

INTRODUCTION: Multiple camera systems are widely used for 3D-motion analysis. Due to increasing accuracies these camera systems gained interest in biomechanical research areas, where high precision measurements are desirable. In the current study different measurement systems were compared regarding their measurement accuracy. MATERIALS AND METHODS: Translational and rotational accuracy measurements as well as the zero offset measurements of seven different measurement systems were performed using two reference devices and two different evaluation algorithms. All measurements were performed in the same room with constant temperature at the same laboratory. Equal positions were measured with the systems according to a standardized protocol. Measurement errors were determined and compared. RESULTS: The highest measurement errors were seen for a measurement system using active ultrasonic markers, followed by another active marker measurement system (infrared) having measurement errors up to several hundred micrometers. The highest accuracies were achieved by three stereo camera systems, using passive 2D marker points having errors typically below 20 µm. CONCLUSIONS: This study can help to better assess the results obtained with different measurement systems. With the focus on the measurement accuracy, only one aspect in the selection of a system was considered. Depending on the requirements of the user, other factors like measurement frequency, the maximum analyzable volume, the marker type or the costs are important factors as well.


Assuntos
Algoritmos , Fenômenos Biomecânicos , Movimento (Física)
2.
Sci Rep ; 12(1): 12979, 2022 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-35902607

RESUMO

The isolated effects of patellar resurfacing on patellar kinematics are rarely investigated. Nonetheless, knowing more about these effects could help to enhance present understanding of the emergence of kinematic improvements or deteriorations associated with patellar resurfacing. The aim of this study was to isolate the effects of patellar resurfacing from a multi-stage in vitro study, where kinematics after total knee arthroplasty before and after patellar resurfacing were recorded. Additionally, the influence of the native patellar geometry on these effects was analysed. Eight fresh frozen specimens were tested successively with different implant configurations on an already established weight bearing knee rig. The patello-femoral kinematics were thereby measured using an ultrasonic measurement system and its relation to the native patellar geometries was analysed. After patellar resurfacing, the specimen showed a significantly medialized patellar shift. This medialization of the patellar tracking was significantly correlated to the lateral facet angle of the native patella. The patellar shift after patellar resurfacing is highly influenced by the position of the patellar button and the native lateral patellar facet angle. As a result, the ideal medio-lateral position of the patellar component is affected by the geometry of the native patella.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Fenômenos Biomecânicos , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Patela/cirurgia