Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Sci Monit ; 20: 2386-93, 2014 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-25416498

RESUMO

BACKGROUND: Extensive type A aortic dissections that involve peripheral great vessels can complicate the choice of a cannulation site for cardiopulmonary bypass. We started to employ direct cannulation of the true lumen on the concavity of the aortic arch by Seldinger technique and evaluated the efficacy of this access technique as an alternative arterial inflow target in aortic surgery. MATERIAL/METHODS: Twenty-four consecutive patients (mean age: 59±14 years) underwent type A aortic dissection repair using selective antegrade cerebral perfusion. Direct aortic cannulation was used in 14 cases, subclavian access in 6 patients, and femoral entry in 4 patients. Perioperative factors were evaluated to identify the reliability and eventual benefits of direct cannulation method at the aortic arch. RESULTS: There were no operative deaths and cumulative 30-day mortality rate was 25% (6). Permanent neurological deficits were not observed; in 1 patient transient changes occurred (4%). Time to reach circulatory arrest was the shortest in the direct access group, with mean 27±11 (CI: 20.6-33.3) min vs. 43±22 (28.0-78.0) min (p=0.058) and 32±8 (23.6-40.4) min (p=0.34) by femoral cannulation and subclavian entry, respectively. Direct arch cannulation resulted in the best renal function in the first 72 h after surgery and similar characteristics were observed in lactic acid levels. CONCLUSIONS: Ultrasound-guided direct cannulation on the concavity of the aortic arch using a Seldinger technique is a reliable method in dissection repairs. Prompt antegrade perfusion provides not only cerebral but also peripheral organ and tissue protection, which is an advantage in this high-risk group of patients.


Assuntos
Aorta Torácica/cirurgia , Aorta/cirurgia , Procedimentos Cirúrgicos Cardiovasculares/métodos , Cateterismo , Creatinina/metabolismo , Demografia , Feminino , Humanos , Cuidados Intraoperatórios , Ácido Láctico/metabolismo , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios
2.
Orv Hetil ; 149(26): 1233-6, 2008 Jun 29.
Artigo em Húngaro | MEDLINE | ID: mdl-18565818

RESUMO

The recently introduced pumpless extracorporeal lung assist (PECLA) is a remarkable alternative to the conventional extracorporeal membrane oxygenation in case of severe lung failure. By establishing a shunt between femoral artery and vein using the arterio-venous pressure gradient as a driving force through a low-resistance membrane oxygenator, PECLA provides highly effective gas-exchange by preserved cardiac function. Due to its closed system, reduced priming volume and low heparin demand, the unfavourable effects of extracorporeal membrane oxygenation can be effectively diminished. Hence the small technical, financial and personal input, the PECLA can be ideally used in district hospitals and during transport as well. Our short summary demonstrates the advantages and safety of the system proven over 123 cases.


Assuntos
Derivação Arteriovenosa Cirúrgica , Oxigenação por Membrana Extracorpórea , Insuficiência Respiratória/terapia , Adulto , Idoso , Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenação por Membrana Extracorpórea/métodos , Feminino , Artéria Femoral/cirurgia , Veia Femoral/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Respiratória/etiologia , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...