Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Infect Dis ; 213 Suppl 2: S59-64, 2016 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-27025700

RESUMO

BACKGROUND: Nonstandardized specimen-transport logistics, lack of laboratory personnel to transport specimens, lack of standard specimen containers, and long turnaround time (TAT) hindered access to quality laboratory services. The objective of the Becton, Dickinson, and Company (BD)-US President's Emergency Plan for AIDS Relief (PEPFAR) Public-Private Partnership (PPP) was to support country-specific programs to develop integrated laboratory systems, services, and quality improvement strategies, with an emphasis on strengthening the specimen-referral system (SRS). METHODS: In 2007, through the Centers for Disease Control and Prevention (CDC), the Ethiopian Public Health Institute (EPHI) joined with the BD-PEPFAR PPP to strengthen laboratory systems. A joint planning and assessment committee identified gaps in the SRS for prioritization and intervention and piloted the system in Addis Ababa and Amhara Region. RESULTS: The PPP established standardized, streamlined specimen logistics, using the Ethiopian Postal Service Enterprise to support a laboratory network in which 554 facilities referred specimens to 160 laboratories. The PPP supported procuring 400 standard specimen containers and the training of 586 laboratory personnel and 81 postal workers. The average TAT was reduced from 7 days (range, 2-14 days) to 2 days (range, 1-3 days) in Addis Ababa and from 10 days (range, 6-21 days) to 5 days (range, 2-6 days) in Amhara Region. CONCLUSIONS: This study highlights the feasibility and untapped potential of PPPs to strengthen laboratory systems. This planned and structured approach to improving specimen referral enhanced access to quality laboratory services.


Assuntos
Laboratórios/normas , Pessoal de Laboratório Médico/educação , Parcerias Público-Privadas , Manejo de Espécimes/normas , Centers for Disease Control and Prevention, U.S. , Etiópia , Humanos , Laboratórios/organização & administração , Programas Nacionais de Saúde , Garantia da Qualidade dos Cuidados de Saúde , Encaminhamento e Consulta , Fatores de Tempo , Estados Unidos
2.
Trop Med Int Health ; 19(6): 734-742, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24684481

RESUMO

OBJECTIVE: To assess the diagnostic performance of urine lipoarabinomannan (LAM) detection for TB screening in HIV-positive adults in Ethiopia. METHODS: Testing for LAM was performed using the Determine TB-LAM lateral flow assay on urine samples from participants in a prospective cohort with baseline bacteriological categorisation for active TB in sputum. Characteristics of TB patients with regard to LAM status were determined. Participants were followed for 6 months to evaluate survival, retention in care and incident TB. RESULTS: Positive LAM results were found in 78/757 participants. Among 128 subjects with definite (confirmed by culture and/or Xpert MTB/RIF) TB, 33 were LAM-positive (25.8%); the respective figure for clinically diagnosed cases was 2/20 (10%). Five of the remaining 43 LAM-positive individuals had died during the 6-month follow-up period, whereas 38 remained in care without clinical signs of TB. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 25.8%, 92.9%, 42.3% and 86.0%, respectively. Among TB patients, LAM positivity was associated with higher WHO clinical stage, lower body mass index (BMI), CD4 cell and haemoglobin levels, and with increased mortality. A combination algorithm of urine LAM testing and sputum smear microscopy detected 49 (38.2%) of definite TB cases; among those with CD4 count ≤100 cells/mm3 , this proportion was 66.7%. CONCLUSIONS: The performance of urine LAM testing for TB detection was poor in this population. However, this was improved among subjects with CD4 count ≤100 cells/mm3 . In combination with sputum microscopy urine, LAM could be considered for targeted TB screening in this subgroup.

3.
PLoS One ; 9(1): e85478, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24465572

RESUMO

BACKGROUND: Detection of active tuberculosis (TB) before antiretroviral therapy (ART) initiation is important, but optimal diagnostic methods for use in resource-limited settings are lacking. We assessed the prevalence of TB, evaluated the diagnostic yield of Xpert MTB/RIF in comparison with smear microscopy and culture, and the impact of Xpert results on clinical management in HIV-positive adults eligible for ART at health centers in a region of Ethiopia. METHODS: Participants were prospectively recruited and followed up at 5 health centers. Trained nurses collected data on socio-demographic characteristics, medical history and symptoms, and performed physical examination. Two paired morning sputum samples were obtained, and lymph node aspirates in case of lymphadenopathy. Diagnostic yield of Xpert MTB/RIF in sputum was compared with smear microscopy and liquid culture. RESULTS: TB was diagnosed in 145/812 participants (17.9%), with bacteriological confirmation in 137 (16.9%). Among bacteriologically confirmed cases, 31 were smear-positive (22.6%), 96 were Xpert-positive (70.1%), and 123 were culture-positive (89.8%). Xpert MTB/RIF increased the TB detection rate by 64 cases (47.4%) compared with smear microscopy. The overall sensitivity of Xpert MTB/RIF was 66.4%, and was not significantly lower when testing one compared with two samples. While Xpert MTB/RIF was 46.7% sensitive among patients with CD4 cell counts >200 cells/mm(3), this increased to 82.9% in those with CD4 cell counts ≤100 cells/mm(3). Compared with Xpert-positive TB patients, Xpert-negative cases had less advanced HIV and TB disease characteristics. CONCLUSIONS: Previously undiagnosed TB is common among HIV-positive individuals managed in Ethiopian health centers. Xpert MTB/RIF increased TB case detection, especially in patients with advanced immunosuppression. An algorithm based on the use of a single morning sputum sample for individuals with negative sputum smear microscopy could be considered for intensified case finding in patients eligible for ART. However, technical and cost-effectiveness issues relevant for low-income countries warrant further study.


Assuntos
Infecções por HIV/complicações , Programas de Rastreamento/métodos , Tuberculose/diagnóstico , Tuberculose/epidemiologia , Adulto , Antibióticos Antituberculose/farmacologia , Técnicas Bacteriológicas/métodos , Farmacorresistência Bacteriana , Etiópia/epidemiologia , Feminino , Humanos , Masculino , Microscopia/métodos , Técnicas de Diagnóstico Molecular/métodos , Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Prevalência , Estudos Prospectivos , Reprodutibilidade dos Testes , Rifampina/farmacologia , Sensibilidade e Especificidade , Escarro/microbiologia , Tuberculose/complicações
4.
Afr J Lab Med ; 3(2): 228, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-26753129

RESUMO

BACKGROUND: In 2010, a National Laboratory Strategic Plan was set forth in Ethiopia to strengthen laboratory quality systems and set the stage for laboratory accreditation. As a result, the Strengthening Laboratory Management Toward Accreditation (SLMTA) programme was initiated in 45 Ethiopian laboratories. OBJECTIVES: This article discusses the implementation of the programme, the findings from the evaluation process and key challenges. METHODS: The 45 laboratories were divided into two consecutive cohorts and staff from each laboratory participated in SLMTA training and improvement projects. The average amount of supportive supervision conducted in the laboratories was 68 hours for cohort I and two hours for cohort II. Baseline and exit audits were conducted in 44 of the laboratories and percent compliance was determined using a checklist with scores divided into zero- to five-star rating levels. RESULTS: Improvements, ranging from < 1 to 51 percentage points, were noted in 42 laboratories, whilst decreases were recorded in two. The average scores at the baseline and exit audits were 40% and 58% for cohort I (p < 0.01); and 42% and 53% for cohort II (p < 0.01), respectively. The p-value for difference between cohorts was 0.07. At the exit audit, 61% of the first and 48% of the second cohort laboratories achieved an increase in star rating. Poor awareness, lack of harmonisation with other facility activities and the absence of a quality manual were challenges identified. CONCLUSION: Improvements resulting from SLMTA implementation are encouraging. Continuous advocacy at all levels of the health system is needed to ensure involvement of stakeholders and integration with other improvement initiatives and routine activities.

5.
PLoS One ; 8(12): e83270, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24358268

RESUMO

BACKGROUND: The clinical correlations and significance of subnormal CD4 levels in HIV-negative patients with TB are unclear. We have determined CD4 cell levels longitudinally during anti-tuberculosis treatment (ATT) in patients, with and without HIV co-infection, and their associations with clinical variables. METHOD: Adults diagnosed with TB (maximum duration of ATT for 2 weeks, and with no history of antiretroviral therapy (ART) in HIV-positive subjects) were included consecutively in eight out-patient clinics in Ethiopia. Healthy individuals were recruited for comparison at one of the study health centers. Data on patient characteristics and physical findings were collected by trained nurses following a structured questionnaire at inclusion and on follow-up visits at 2 and 6 months. In parallel, peripheral blood CD4 cell levels were determined. The evolution of CD4 cell levels during ATT was assessed, and the association between clinical characteristics and low CD4 cell levels at baseline was investigated using regression analysis. RESULTS: In total, 1116 TB patients were included (307 HIV-infected). Among 809 HIV-negative patients, 200 (25%) had subnormal CD4 cell counts (<500 cells/mm(3)), with <350 cells/mm(3) in 82 (10%) individuals. CD4 cell levels increased significantly during the course of ATT in both HIV+ and HIV- TB-patients, but did not reach the levels in healthy subjects (median 896 cells/mm(3)). Sputum smear status, signs of wasting (low mid upper arm circumference (MUAC)), and bedridden state were significantly associated with low CD4 cell counts. CONCLUSION: A high proportion of Ethiopian TB patients have subnormal CD4 cell counts before starting treatment. Low CD4 cell levels are associated with smear positive disease and signs of wasting. The continuous increase of CD4 cell counts during the course of ATT suggest a reversible impact of active TB on CD4 cell homeostasis, which may be considered in interpretation of CD4 cell counts in HIV/TB co-infected subjects.


Assuntos
Antituberculosos/uso terapêutico , Biomarcadores , Linfócitos T CD4-Positivos/efeitos dos fármacos , Linfopenia/diagnóstico , Tuberculose/tratamento farmacológico , Tuberculose/imunologia , Adulto , Biomarcadores/análise , Contagem de Linfócito CD4 , Linfócitos T CD4-Positivos/patologia , Estudos de Coortes , Coinfecção , Etiópia , Feminino , Infecções por HIV/complicações , Infecções por HIV/diagnóstico , Infecções por HIV/epidemiologia , Infecções por HIV/imunologia , Humanos , Linfopenia/complicações , Linfopenia/epidemiologia , Masculino , Tuberculose/complicações , Tuberculose/diagnóstico , Adulto Jovem
6.
J Public Health Policy ; 33(1): 34-45, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22071568

RESUMO

Properly functioning laboratory equipment is a critical component for strengthening health systems in developing countries. The laboratory can be an entry point to improve population health and care of individuals for targeted diseases - prevention, care, and treatment of TB, HIV/AIDS, and malaria, plus maternal and neonatal health - as well as those lacking specific attention and funding. We review the benefits and persistent challenges associated with sustaining laboratory equipment maintenance. We propose equipment management policies as well as a comprehensive equipment maintenance strategy that would involve equipment manufacturers and strengthen local capacity through pre-service training of biomedical engineers. Strong country leadership and commitment are needed to assure development and sustained implementation of policies and strategies for standardization of equipment, and regulation of its procurement, donation, disposal, and replacement.


Assuntos
Equipamentos e Provisões , Laboratórios/organização & administração , Pessoal de Laboratório Médico/educação , Programas Nacionais de Saúde/organização & administração , África Subsaariana , Técnicas de Laboratório Clínico , Atenção à Saúde/organização & administração , Países em Desenvolvimento , Recursos em Saúde , Humanos
7.
Trop Med Int Health ; 15(12): 1449-57, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21040254

RESUMO

OBJECTIVES AND METHODS: Quality laboratory services are a requisite to guide rational case management of malaria. Using a pre-tested, standardized assessment tool, we assessed laboratory diagnostic capacity in 69 primary, secondary and tertiary health facilities as well as specialized laboratories in five administrative zones in Oromia Regional State, Ethiopia, during February and March 2009. RESULTS: There was marked variability in laboratory diagnostic capacity among the facilities assessed. Of 69 facilities surveyed, 53 provided both comprehensive malaria laboratory diagnosis and outpatient treatment services, five provided malaria microscopy services (referring elsewhere for treatment), and 11 primary care health posts provided rapid diagnostic testing and outpatient malaria treatment. The facilities' median catchment population was 39, 562 and 3581 people for secondary/tertiary and primary health facilities, respectively. Depending on facility type, facilities provided services 24 hrs a day, had inpatient capacity, and access to water and electricity. Facilities were staffed by general practitioners, health officers, nurses or health extension workers. Of the 58 facilities providing laboratory services, 24% of the 159 laboratory staff had received malaria microscopy training in the year prior to this survey, and 72% of the facilities had at least one functional electric binocular microscope. Facilities had variable levels of equipment, materials and biosafety procedures necessary for laboratory diagnosis of malaria. The mean monthly number of malaria blood films processed at secondary/tertiary facilities was 225, with a mean monthly 56 confirmed parasitologically. In primary facilities, the mean monthly number of clinical malaria cases seen was 75, of which 57 were tested by rapid diagnostic test (RDTs). None of the surveyed laboratory facilities had formal quality assurance/quality control protocols for either microscopy or RDTs. CONCLUSIONS: This is the first published report on malaria diagnostic capacity in Ethiopia. While our assessment indicated that malaria laboratory diagnosis was available in most facilities surveyed, we observed significant gaps in laboratory services which could significantly impact quality and accessibility of malaria diagnosis, including laboratory infrastructure, equipment, laboratory supplies and human resources.


Assuntos
Laboratórios/normas , Malária/diagnóstico , Técnicas de Laboratório Clínico/instrumentação , Técnicas de Laboratório Clínico/normas , Países em Desenvolvimento , Etiópia , Humanos , Controle de Infecções/métodos , Malária/prevenção & controle , Malária/transmissão , Pessoal de Laboratório Médico/educação , Garantia da Qualidade dos Cuidados de Saúde , Recursos Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...