Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 94(28): 10035-10044, 2022 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-35786855

RESUMO

In this study, we examine the suitability of desorption electro-flow focusing ionization (DEFFI) for mass spectrometry imaging (MSI) of biological tissue. We also compare the performance of desorption electrospray ionization (DESI) with and without the flow focusing setup. The main potential advantages of applying the flow focusing mechanism in DESI is its rotationally symmetric electrospray jet, higher intensity, more controllable parameters, and better portability due to the robustness of the sprayer. The parameters for DEFFI have therefore been thoroughly optimized, primarily for spatial resolution but also for intensity. Once the parameters have been optimized, DEFFI produces similar images to the existing DESI. MS images for mouse brain samples, acquired at a nominal pixel size of 50 µm, are comparable for both DESI setups, albeit the new sprayer design yields better sensitivity. Furthermore, the two methods are compared with regard to spectral intensity as well as the area of the desorbed crater on rhodamine-coated slides. Overall, the implementation of a flow focusing mechanism in DESI is shown to be highly suitable for imaging biological tissue and has potential to overcome some of the shortcomings experienced with the current geometrical design of DESI.


Assuntos
Diagnóstico por Imagem , Espectrometria de Massas , Espectrometria de Massas por Ionização por Electrospray , Animais , Encéfalo/diagnóstico por imagem , Camundongos , Espectrometria de Massas por Ionização por Electrospray/métodos
2.
ACS Cent Sci ; 4(1): 39-51, 2018 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-29392175

RESUMO

Analyzing lipid composition and distribution within the brain is important to study white matter pathologies that present focal demyelination lesions, such as multiple sclerosis. Some lesions can endogenously re-form myelin sheaths. Therapies aim to enhance this repair process in order to reduce neurodegeneration and disability progression in patients. In this context, a lipidomic analysis providing both precise molecular classification and well-defined localization is crucial to detect changes in myelin lipid content. Here we develop a correlated heterospectral lipidomic (HSL) approach based on coregistered Raman spectroscopy, desorption electrospray ionization mass spectrometry (DESI-MS), and immunofluorescence imaging. We employ HSL to study the structural and compositional lipid profile of demyelination and remyelination in an induced focal demyelination mouse model and in multiple sclerosis lesions from patients ex vivo. Pixelwise coregistration of Raman spectroscopy and DESI-MS imaging generated a heterospectral map used to interrelate biomolecular structure and composition of myelin. Multivariate regression analysis enabled Raman-based assessment of highly specific lipid subtypes in complex tissue for the first time. This method revealed the temporal dynamics of remyelination and provided the first indication that newly formed myelin has a different lipid composition compared to normal myelin. HSL enables detailed molecular myelin characterization that can substantially improve upon the current understanding of remyelination in multiple sclerosis and provides a strategy to assess remyelination treatments in animal models.

3.
J Am Soc Mass Spectrom ; 28(10): 2090-2098, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28620847

RESUMO

A new, more robust sprayer for desorption electrospray ionization (DESI) mass spectrometry imaging is presented. The main source of variability in DESI is thought to be the uncontrolled variability of various geometric parameters of the sprayer, primarily the position of the solvent capillary, or more specifically, its positioning within the gas capillary or nozzle. If the solvent capillary is off-center, the sprayer becomes asymmetrical, making the geometry difficult to control and compromising reproducibility. If the stiffness, tip quality, and positioning of the capillary are improved, sprayer reproducibility can be improved by an order of magnitude. The quality of the improved sprayer and its potential for high spatial resolution imaging are demonstrated on human colorectal tissue samples by acquisition of images at pixel sizes of 100, 50, and 20 µm, which corresponds to a lateral resolution of 40-60 µm, similar to the best values published in the literature. The high sensitivity of the sprayer also allows combination with a fast scanning quadrupole time-of-flight mass spectrometer. This provides up to 30 times faster DESI acquisition, reducing the overall acquisition time for a 10 mm × 10 mm rat brain sample to approximately 1 h. Although some spectral information is lost with increasing analysis speed, the resulting data can still be used to classify tissue types on the basis of a previously constructed model. This is particularly interesting for clinical applications, where fast, reliable diagnosis is required. Graphical Abstract ᅟ.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos , Animais , Neoplasias Colorretais/diagnóstico por imagem , Desenho de Equipamento , Humanos , Fígado/diagnóstico por imagem , Reprodutibilidade dos Testes , Solventes
4.
Anal Chem ; 88(9): 4808-16, 2016 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-27014929

RESUMO

In this study, the impact of sprayer design and geometry on performance in desorption electrospray ionization mass spectrometry (DESI-MS) is assessed, as the sprayer is thought to be a major source of variability. Absolute intensity repeatability, spectral composition, and classification accuracy for biological tissues are considered. Marked differences in tissue analysis performance are seen between the commercially available and a lab-built sprayer. These are thought to be associated with the geometry of the solvent capillary and the resulting shape of the primary electrospray. Experiments with a sprayer with a fixed solvent capillary position show that capillary orientation has a crucial impact on tissue complex lipid signal and can lead to an almost complete loss of signal. Absolute intensity repeatability is compared for five lab-built sprayers using pork liver sections. Repeatability ranges from 1 to 224% for individual sprayers and peaks of different spectral abundance. Between sprayers, repeatability is 16%, 9%, 23%, and 34% for high, medium, low, and very low abundance peaks, respectively. To assess the impact of sprayer variability on tissue classification using multivariate statistical tools, nine human colorectal adenocarcinoma sections are analyzed with three lab-built sprayers, and classification accuracy for adenocarcinoma versus the surrounding stroma is assessed. It ranges from 80.7 to 94.5% between the three sprayers and is 86.5% overall. The presented results confirm that the sprayer setup needs to be closely controlled to obtain reliable data, and a new sprayer setup with a fixed solvent capillary geometry should be developed.


Assuntos
Adenocarcinoma/diagnóstico , Neoplasias Colorretais/diagnóstico , Lipídeos/análise , Fígado/química , Imagem Molecular , Espectrometria de Massas por Ionização por Electrospray , Animais , Humanos , Suínos
5.
Artigo em Inglês | MEDLINE | ID: mdl-24761990

RESUMO

Options were explored for fulfilling the legally required safety assessment for a widely applied epoxy/amine coating used for restoring corroded domestic drinking water supply systems. The coating was made up of two components mixed shortly before application, the first mainly consisting of bisphenol A diglycidyl ether (BADGE), the second of various amines. The analytically identified starting substances were all authorised, but only constituted a small proportion of the low molecular mass material left after curing and potentially migrating into water. Reaction products synthesised from constituents of the starting components (expected oligomers) could not be eluted from GC even after derivatisation, indicating that standard GC-MS screening would miss most potential migrants. They were detectable by size exclusion chromatography (SEC) after acetylation. HPLC with MS or fluorescence detection was possible for constituents including a BADGE moiety, but phenalkamines could not be detected with adequate sensitivity. Possibilities for determining long-term migration relevant for chronic toxicity are discussed. Analysis in water shortly after application of the coating overestimates migration if migration decreases over time and requires detection limits far out of reach. Analysis of a solvent extract of the coating is easier and provides an upper estimate of what could migrate into the drinking water over the years. However, to satisfy the regulatory requirements, components of the complex mixture need to be identified at lower proportions than those accessible. In vitro testing of the whole mixture for genotoxicity is expected to fail because of the required sensitivity and the glycidyl functions probably wrongly resulting in positive tests. The difficulties in dealing with this situation are discussed.


Assuntos
Aminas/análise , Compostos Benzidrílicos/análise , Compostos de Epóxi/análise , Engenharia Sanitária/instrumentação , Abastecimento de Água/análise , Aminas/toxicidade , Compostos Benzidrílicos/toxicidade , Cromatografia Líquida de Alta Pressão , Materiais de Construção/análise , Materiais de Construção/toxicidade , Exposição Ambiental , Compostos de Epóxi/toxicidade , União Europeia , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Limite de Detecção , Medição de Risco , Engenharia Sanitária/legislação & jurisprudência , Engenharia Sanitária/normas , Fatores de Tempo , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/toxicidade , Abastecimento de Água/legislação & jurisprudência , Abastecimento de Água/normas
6.
J Chromatogr A ; 1315: 36-46, 2013 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-24094751

RESUMO

In this study, an automated method for the simultaneous determination of polycyclic aromatic hydrocarbons (PAHs) and their chlorination by-products in drinking water was developed based on online solid-phase microextraction-gas chromatography-mass spectrometry. The main focus was the optimisation of the solid-phase microextraction step. The influence of the agitation rate, type of fibre, desorption time, extraction time, extraction temperature, desorption temperature, and solvent addition was examined. The method was developed and validated using a mixture of 17 PAHs, 11 potential chlorination by-products (chlorinated and oxidised PAHs) and 6 deuterated standards. The limit of quantification was 10 ng/L for all target compounds. The validated method was used to analyse drinking water samples from three different drinking water distribution networks and the presumably coal tar-based pipe coatings of two pipe sections. A number of PAHs were detected in all three networks although individual compositions varied. Several PAH chlorination by-products (anthraquinone, fluorenone, cyclopenta[d,e,f]phenanthrenone, 3-chlorofluoranthene, and 1-chloropyrene) were also found, their presence correlating closely with that of their respective parent compounds. Their concentrations were always below 100 ng/L. In the coatings, all PAHs targeted were detected although concentrations varied between the two coatings (76-12,635 mg/kg and 12-6295 mg/kg, respectively). A number of chlorination by-products (anthraquinone, fluorenone, cyclopenta[d,e,f]phenanthrenone, 3-chlorofluoranthene, and 1-chloropyrene) were also detected (from 40 to 985 mg/kg), suggesting that the reaction of PAHs with disinfectant agents takes place in the coatings and not in the water phase after migration.


Assuntos
Água Potável/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Hidrocarbonetos Policíclicos Aromáticos/análise , Microextração em Fase Sólida/métodos , Abastecimento de Água/análise , Acetatos/química , Hidrocarbonetos Policíclicos Aromáticos/química , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...