2.
Ann Biomed Eng ; 49(7): 1735-1746, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33452593

RESUMO

This paper presents a two magnetic sensor based tracking method for a magnetically inflated intragastric balloon capsule (MIBC) which is used for obesity treatment. After the MIBC is swallowed, it is designed to be inflated inside the stomach by approaching a permanent magnet (PM) externally near the abdomen. However, if the balloon inflation is accidentally triggered while the MIBC is still in the esophagus, the esophagus will be damaged. Therefore, to safely inflate the MIBC, we aim to track the MIBC's position along the esophagus and confirm the MIBC passes through. Typically, magnetic sensor based tracking systems tend to be bulky and costly since they involve computationally intensive optimization with many magnetic sensors. To solve those problems, we develop an algorithm that estimates the position of the PM inside the MIBC by using the grid search combined with the dynamically confined search range and search threshold modulation. Our tracking method achieved an average 1D position error of 3.48 mm which is comparable to the up to 4 mm average error for the other magnetic sensor based tracking systems that require more sensors and computational power compared to our system.


Assuntos
Algoritmos , Deglutição , Desenho de Equipamento , Balão Gástrico , Humanos , Fenômenos Magnéticos
3.
Ann Biomed Eng ; 49(5): 1391-1401, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33215368

RESUMO

Intragastric balloons (IGBs), by occupying the stomach space and prolonging satiety, is a promising method to treat obesity and consequently improves its associated comorbidities, e.g. coronary heart disease, diabetes, and cancer. However, existing IGBs are often tethered with tubes for gas or liquid delivery or require endoscopic assistance for device delivery or removal, which are usually uncomfortable, costly, and may cause complications. This paper presents a novel tetherless, magnetically actuated capsule (EndoPil) which can deploy an IGB inside the stomach after being swallowed and being activated by an external magnet. The external magnet attracts a small magnet inside the EndoPil to open a valve, triggering the chemical reaction of citric acid and potassium bicarbonate to produce carbon dioxide gas, which inflates a biocompatible balloon (around 120 mL). A prototype, 13 mm in diameter and 35 mm in length, was developed. Simulations and bench-top tests were conducted to test the force capability of the magnetic actuation mechanism, the required force to activate the valve, and the repeatability of balloon inflation. Experiments on animal and human were successfully conducted to demonstrate the safety and feasibility of inflating a balloon inside the stomach by an external magnet.


Assuntos
Cápsulas/administração & dosagem , Balão Gástrico , Imãs , Adulto , Animais , Bicarbonatos/administração & dosagem , Bicarbonatos/química , Dióxido de Carbono/química , Ácido Cítrico/administração & dosagem , Ácido Cítrico/química , Deglutição , Endoscopia , Desenho de Equipamento , Feminino , Humanos , Fenômenos Magnéticos , Obesidade/terapia , Compostos de Potássio/administração & dosagem , Compostos de Potássio/química , Suínos
5.
Ann Biomed Eng ; 48(1): 342-356, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31485875

RESUMO

Haptic feedback for flexible endoscopic surgical robots is challenging due to space constraints for sensors and shape-dependent force hysteresis of tendon-sheath mechanisms (TSMs). This paper proposes (1) a single-axis fiber Bragg grating (FBG)-based force sensor for a TSM of a robotic arm and (2) an integrated sensor-model approach to estimate forces on other TSMs of that arm. With a robust and simple structure, a temperature-compensated sensor can be mounted on the distal sheath to measure forces applied by the TSM. This proposed sensor was integrated with a Ø4.2 mm articulated robotic arm driven by six TSMs, with a measurement error of 0.37 N in this work. The measurement from the single sensor was used to identify parameters in the force-transmission models of all other TSMs in the robot, realizing a one-sensor-for-all-distal-forces measurement method. The sensor-model approach could accurately estimate the distal force with an RMSE of 0.65 N. An animal study was carried out to demonstrate the sensor's feasibility in real-life surgery. The sensor-model approach presented a robust, space-saving, and cost-effective solution for haptic feedback of endoscopic robots without any assumption on the shapes of the robot.


Assuntos
Endoscopia/instrumentação , Retroalimentação , Robótica , Animais , Colo/cirurgia , Suínos