Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Neuropathol Commun ; 9(1): 128, 2021 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-34289895

RESUMO

The medial temporal lobe (MTL) is a nidus for neurodegenerative pathologies and therefore an important region in which to study polypathology. We investigated associations between neurodegenerative pathologies and the thickness of different MTL subregions measured using high-resolution post-mortem MRI. Tau, TAR DNA-binding protein 43 (TDP-43), amyloid-ß and α-synuclein pathology were rated on a scale of 0 (absent)-3 (severe) in the hippocampus and entorhinal cortex (ERC) of 58 individuals with and without neurodegenerative diseases (median age 75.0 years, 60.3% male). Thickness measurements in ERC, Brodmann Area (BA) 35 and 36, parahippocampal cortex, subiculum, cornu ammonis (CA)1 and the stratum radiatum lacunosum moleculare (SRLM) were derived from 0.2 × 0.2 × 0.2 mm3 post-mortem MRI scans of excised MTL specimens from the contralateral hemisphere using a semi-automated approach. Spearman's rank correlations were performed between neurodegenerative pathologies and thickness, correcting for age, sex and hemisphere, including all four proteinopathies in the model. We found significant associations of (1) TDP-43 with thickness in all subregions (r = - 0.27 to r = - 0.46), and (2) tau with BA35 (r = - 0.31) and SRLM thickness (r = - 0.33). In amyloid-ß and TDP-43 negative cases, we found strong significant associations of tau with ERC (r = - 0.40), BA35 (r = - 0.55), subiculum (r = - 0.42) and CA1 thickness (r = - 0.47). This unique dataset shows widespread MTL atrophy in relation to TDP-43 pathology and atrophy in regions affected early in Braak stageing and tau pathology. Moreover, the strong association of tau with thickness in early Braak regions in the absence of amyloid-ß suggests a role of Primary Age-Related Tauopathy in neurodegeneration.


Assuntos
Córtex Entorrinal/diagnóstico por imagem , Hipocampo/diagnóstico por imagem , Doenças Neurodegenerativas/diagnóstico por imagem , Lobo Temporal/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/metabolismo , Doença de Alzheimer/patologia , Peptídeos beta-Amiloides/metabolismo , Espessura Cortical do Cérebro , Região CA1 Hipocampal/diagnóstico por imagem , Região CA1 Hipocampal/metabolismo , Região CA1 Hipocampal/patologia , Estudos de Casos e Controles , Proteínas de Ligação a DNA/metabolismo , Córtex Entorrinal/metabolismo , Córtex Entorrinal/patologia , Feminino , Degeneração Lobar Frontotemporal/diagnóstico por imagem , Degeneração Lobar Frontotemporal/metabolismo , Degeneração Lobar Frontotemporal/patologia , Hipocampo/metabolismo , Hipocampo/patologia , Humanos , Doença por Corpos de Lewy/diagnóstico por imagem , Doença por Corpos de Lewy/metabolismo , Doença por Corpos de Lewy/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Doenças Neurodegenerativas/metabolismo , Doenças Neurodegenerativas/patologia , Emaranhados Neurofibrilares/patologia , Giro Para-Hipocampal/diagnóstico por imagem , Giro Para-Hipocampal/metabolismo , Giro Para-Hipocampal/patologia , Doença de Pick/diagnóstico por imagem , Doença de Pick/metabolismo , Doença de Pick/patologia , Placa Amiloide/patologia , Paralisia Supranuclear Progressiva/diagnóstico por imagem , Paralisia Supranuclear Progressiva/metabolismo , Paralisia Supranuclear Progressiva/patologia , Lobo Temporal/metabolismo , Lobo Temporal/patologia , alfa-Sinucleína/metabolismo , Proteínas tau/metabolismo
2.
Ultrasound Obstet Gynecol ; 58(5): 722-731, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32898295

RESUMO

OBJECTIVES: Clinical assessment of uterine artery (UtA) hemodynamics is currently limited to Doppler ultrasound (US) velocimetry. We have demonstrated previously the feasibility of applying four-dimensional (4D) flow magnetic resonance imaging (MRI) to evaluate UtA hemodynamics during pregnancy, allowing flow quantification of the entire course of the vessel. In this study, we sought to further validate the physiological relevance of 4D flow MRI measurement of UtA blood flow by exploring its association with pregnancy outcome relative to US-based metrics. METHODS: Recruited into this prospective, cross-sectional study were 87 women with a singleton pregnancy who underwent 4D flow MRI between May 2016 and April 2019 to measure the UtA pulsatility index (MRI-PI) and blood flow rate (MRI-flow, in mL/min). UtA-PI was also measured using US (US-PI). The primary outcome was a composite (COMP) of pre-eclampsia (PE) and/or small-for-gestational-age (SGA) neonate, and secondary outcomes were PE and SGA neonate individually. We assessed the ability of MRI-flow, MRI-PI and US-PI to distinguish between outcomes, and evaluated whether MRI-flow changed as gestation progressed. RESULTS: Following 4D flow postprocessing and exclusions from the analysis, 74 women had 4D flow MRI data analyzed for both UtAs. Of these, 18 developed a COMP outcome: three developed PE only, 11 had a SGA neonate only and four had both. A comparison of the COMP group vs the no-COMP group found no differences in maternal age, body mass index, nulliparity, gravidity or race. For 66 of the 74 subjects, US data were also available. In these subjects, both median MRI-PI (0.95 vs 0.70; P < 0.01) and median US-PI (0.95 vs 0.73; P < 0.01) were significantly increased in subjects in the COMP group compared with those in the no-COMP group. The UtA blood-flow rate, as measured by MRI, did not increase significantly from the second to the third trimester (median flow (interquartile range (IQR)), 543 (419-698) vs 575 (440-746) mL/min; P = 0.77), but it was significantly lower overall in the COMP compared with the no-COMP group (median flow (IQR), 486 (366-598) vs 624 (457-749) mL/min; P = 0.04). The areas under the receiver-operating-characteristics curves for MRI-flow, MRI-PI and US-PI in predicting COMP were not significantly different (0.694, 0.737 and 0.731, respectively; P = 0.87). CONCLUSIONS: 4D flow MRI can yield physiological measures of UtA blood-flow rate and PI that are associated with adverse pregnancy outcome. This may open up new avenues in the future to expand the potential of this technique as a robust tool with which to evaluate UtA hemodynamics in pregnancy. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Circulação Placentária , Diagnóstico Pré-Natal/métodos , Artéria Uterina/diagnóstico por imagem , Adulto , Área Sob a Curva , Velocidade do Fluxo Sanguíneo , Estudos Transversais , Feminino , Retardo do Crescimento Fetal/diagnóstico por imagem , Hemodinâmica , Humanos , Recém-Nascido , Recém-Nascido Pequeno para a Idade Gestacional , Pré-Eclâmpsia/diagnóstico por imagem , Valor Preditivo dos Testes , Gravidez , Resultado da Gravidez , Terceiro Trimestre da Gravidez/fisiologia , Estudos Prospectivos , Fluxo Pulsátil , Reprodutibilidade dos Testes , Artéria Uterina/embriologia
3.
Neuroimage ; 80: 220-33, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-23707579

RESUMO

Perhaps more than any other "-omics" endeavor, the accuracy and level of detail obtained from mapping the major connection pathways in the living human brain with diffusion MRI depend on the capabilities of the imaging technology used. The current tools are remarkable; allowing the formation of an "image" of the water diffusion probability distribution in regions of complex crossing fibers at each of half a million voxels in the brain. Nonetheless our ability to map the connection pathways is limited by the image sensitivity and resolution, and also the contrast and resolution in encoding of the diffusion probability distribution. The goal of our Human Connectome Project (HCP) is to address these limiting factors by re-engineering the scanner from the ground up to optimize the high b-value, high angular resolution diffusion imaging needed for sensitive and accurate mapping of the brain's structural connections. Our efforts were directed based on the relative contributions of each scanner component. The gradient subsection was a major focus since gradient amplitude is central to determining the diffusion contrast, the amount of T2 signal loss, and the blurring of the water PDF over the course of the diffusion time. By implementing a novel 4-port drive geometry and optimizing size and linearity for the brain, we demonstrate a whole-body sized scanner with G(max) = 300 mT/m on each axis capable of the sustained duty cycle needed for diffusion imaging. The system is capable of slewing the gradient at a rate of 200 T/m/s as needed for the EPI image encoding. In order to enhance the efficiency of the diffusion sequence we implemented a FOV shifting approach to Simultaneous MultiSlice (SMS) EPI capable of unaliasing 3 slices excited simultaneously with a modest g-factor penalty allowing us to diffusion encode whole brain volumes with low TR and TE. Finally we combine the multi-slice approach with a compressive sampling reconstruction to sufficiently undersample q-space to achieve a DSI scan in less than 5 min. To augment this accelerated imaging approach we developed a 64-channel, tight-fitting brain array coil and show its performance benefit compared to a commercial 32-channel coil at all locations in the brain for these accelerated acquisitions. The technical challenges of developing the over-all system are discussed as well as results from SNR comparisons, ODF metrics and fiber tracking comparisons. The ultra-high gradients yielded substantial and immediate gains in the sensitivity through reduction of TE and improved signal detection and increased efficiency of the DSI or HARDI acquisition, accuracy and resolution of diffusion tractography, as defined by identification of known structure and fiber crossing.


Assuntos
Encéfalo/anatomia & histologia , Encéfalo/fisiologia , Conectoma/métodos , Imagem de Tensor de Difusão/métodos , Aumento da Imagem/métodos , Modelos Anatômicos , Modelos Neurológicos , Animais , Humanos , Rede Nervosa/anatomia & histologia , Rede Nervosa/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...