Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38796731

RESUMO

PURPOSE: Instability of the glenohumeral joint remains a complex clinical issue with high rates of surgical failure and significant morbidity. Advances in specific radiologic measurements involving the glenoid and the humerus have provided insight into glenohumeral pathology, which can be corrected surgically towards improving patient outcomes. The contributions of capsular pathology to ongoing instability remain unclear. The purpose of this study is to provide a systematic review of existing glenohumeral capsular measurement techniques published in the last 15 years. METHODS: A systematic review of multiple databases was performed following PRISMA guidelines for all primary research articles between 2008 and 2023 with quantitative measurements of the glenohumeral capsule in patients with instability, including anterior, posterior and multi-directional instability. RESULTS: There were a total of 14 articles meeting the inclusion criteria. High variability in measurement methodology across studies was observed, including variable amounts of intra-articular contrast, heterogeneity among magnetic resonance sequence acquisitions, differences in measurements performed and the specific approach taken to compute each measurement. CONCLUSION: There is a need for standardization of methods in the measurement of glenohumeral capsular pathology in the setting of glenohumeral instability to allow for cross-study analysis. LEVEL OF EVIDENCE: Level III.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38081472

RESUMO

BACKGROUND AND HYPOTHESIS: Anterior shoulder instability is a common problem affecting young, athletic populations that results in potential career-altering functional limitations. However, little is known regarding the differences in clinical outcomes after operative management of overhead vs. non-overhead athletes presenting with first-time anterior shoulder instability. We hypothesized that overhead athletes would have milder clinical presentations, similar surgical characteristics, and diminished postoperative outcomes when compared with non-overhead athletes after surgical stabilization following first-time anterior shoulder instability episodes. METHODS: Patients with first-time anterior shoulder instability events (subluxations and dislocations) undergoing operative management between 2013 and 2020 were included. The exclusion criteria included multiple dislocations and multidirectional shoulder instability. Baseline demographic characteristics, imaging data, examination findings, and intraoperative findings were retrospectively collected. Patients were contacted to collect postoperative patient-reported outcomes including American Shoulder and Elbow Surgeons score, Western Ontario Shoulder Instability Index score, Brophy activity index score, and Subjective Shoulder Value, in addition to return-to-work and -sport, recurrent dislocation, and revision rates. RESULTS: A total of 256 patients met the inclusion criteria, of whom 178 (70%) were non-overhead athletes. The mean age of the entire population was 23.1 years. There was no significant difference in concomitant shoulder pathology, preoperative range of motion, or preoperative strength between cohorts. A greater proportion of overhead athletes presented with instability events not requiring manual reduction (defined as subluxations; 64.1% vs. 50.6%; P < .001) and underwent arthroscopic surgery (97% vs. 76%, P < .001) compared with non-overhead athletes. A smaller proportion of overhead athletes underwent open soft-tissue stabilization compared with non-overhead athletes (1% vs. 19%, P < .001). Outcome data were available for 60 patients with an average follow-up period of 6.7 years. No significant differences were found between groups with respect to recurrent postoperative instability event rate (13.0% for overhead athletes vs. 16.8% for non-overhead athletes), revision rate (13.0% for overhead athletes vs. 11.1% for non-overhead athletes), American Shoulder and Elbow Surgeons score, Western Ontario Shoulder Instability Index score, Brophy score, Subjective Shoulder Value, or rates of return to work or sport. CONCLUSION: Overhead athletes who underwent surgery after an initial instability event were more likely to present with subluxations compared with non-overhead athletes. With limited follow-up subject to biases, this study found no differences in recurrence or revision rates, postoperative patient-reported outcomes, or return-to-work or -sport rates between overhead and non-overhead athletes undergoing shoulder stabilization surgery following first-time instability events. Although larger prospective studies are necessary to draw firmer conclusions, the findings of this study suggest that overhead athletes can be considered in the same treatment pathway for first-time dislocation as non-overhead athletes.

3.
J Arthroplasty ; 2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38040065

RESUMO

BACKGROUND: A shift toward same-day discharge (SDD) in primary elective total knee arthroplasty (TKA) and total hip arthroplasty (THA) has created a need to optimize patient selection and improve same-day recovery pathways. The objectives of this study were (1) to identify our institution's most common causes for failed SDD, and (2) to evaluate risk factors associated with failed SDD. METHODS: A retrospective review of SDD patients undergoing primary TKA or THA from January 2021 to September 2022 was conducted. Reasons for SDD failure were recorded and differences between successful and failed SDD cases were assessed via a multivariate logistic regression. RESULTS: Overall, 85.3% (651 of 753) of patients included were successful SDDs. Failed SDD occurred in 16.8% (74 of 441) of TKA and 11.8% (38 of 322) of THA cases. Primary reasons included failure to clear physical therapy (33.0%, 37 of 112), postoperative hypotension (20.5%, 23 of 112), and urinary retention (16.9%, 19 of 112). Analysis revealed that overall failed SDD cases were more likely to have had prior opioid use and a longer surgical time. Failed TKA SDD cases were more likely to have had a longer surgical time and not have receive a preoperative nerve block, while failed THA SDD cases were more likely to be older. CONCLUSIONS: The SDD selection criteria and pathways continue to evolve, with multiple factors contributing to failed SDD. Improving patient selection algorithms and optimizing post-operative pathways can enhance the ability to successfully choose SDD candidates. LEVEL OF EVIDENCE: III.

4.
Pediatr Cardiol ; 44(8): 1710-1715, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37561172

RESUMO

BACKGROUND: Supraventricular tachycardia (SVT) is a relatively frequent diagnosis in the pediatric emergency department (ED). However, there are no consensus guidelines for ED disposition, and there are limited data on ED outcomes. Better understanding of those who are admitted or have antiarrhythmic medication changes may avoid potentially unnecessary transfers or admissions. Our objective was to identify patient factors associated with discharge from the emergency department without medication initiation or modification after management of SVT in the pediatric ED. DESIGN/METHODS: A retrospective review of children aged 0-18 years seen in the emergency department for SVT was conducted using electronic medical record data over a ten-year period at a single academic tertiary children's hospital. Patients with congenital cardiac disease or prior cardiac surgeries were excluded. Multivariable logistic regression analysis was used to determine association between patient factors of interest and the primary outcome of admission and secondary outcome of change to antiarrhythmic medications. RESULTS: We analyzed 197 patients encounters. The mean age was 7 years. Of these 104 (52.8%) were admitted to the hospital or discharged with antiarrhythmic medication changes. This primary outcome was associated with younger age (aOR 0.77, 95% CI 0.67-0.86), history of pre-excitation (aOR 5.82, 95% CI 2.01-18.8), intercurrent illness (aOR 3.75, 95% CI 1.27-12.1), number of adenosine doses prior to arrival (aOR 5.45, 95% CI 1.55-22.3), and in-person cardiology consultation (aOR 6.42, 95% CI 2.43-19.4). CONCLUSIONS: Nearly half of children treated in a pediatric ED for SVT are discharged without changes in medications. We identified patient factors associated with hospital admission or antiarrhythmic medication changes. These factors represent high value care and can be assessed when considering transfer from a referring facility. Risk stratification using these patient characteristics may reduce potentially avoidable transfers and admissions.


Assuntos
Antiarrítmicos , Taquicardia Supraventricular , Criança , Humanos , Antiarrítmicos/uso terapêutico , Adenosina , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/tratamento farmacológico , Serviço Hospitalar de Emergência , Estudos Retrospectivos , Hospitais Pediátricos
5.
Global Spine J ; : 21925682231166379, 2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-37129370

RESUMO

STUDY DESIGN: Observational Database Study. OBJECTIVES: Prospective clinical trials in spinal surgery are expensive to conduct, especially when randomized, appropriately powered, and/or multicentered. Industry collaborations generate symbiotic relationships promoting technological advancement; however, they also allow for bias. To the authors' knowledge, there is no known analysis of correlations between industry sponsorship and publication rates of spine-related clinical trials. This observational work evaluates such potential associations. METHODS: The ClinicalTrials.gov database was queried with terms spine, spinal, spondylosis, spondylolysis, cervical, lumbar, and compression fracture over an 11-year period. Design characteristics and outcomes were recorded from 822 spine surgery-related trials. Trials were stratified based on funding source and intervention class. Groups were compared via two-tailed chi-square test of independence or Fisher's exact test (α = .05), based on completion status and publication rates of positive vs negative results. RESULTS: Industry-sponsored spine-related clinical trials were more likely to be terminated than their non-industry-sponsored counterparts (P < .001). Of the trials achieving publication, industry-sponsored trials reported positive results at a higher rate than did trials without industry funding (P = .037). Clinical trials examining devices were more likely to be terminated than those studying other intervention classes (P = .001). CONCLUSIONS: High termination rates and positive result publication rates among industry-sponsored clinical trials in spinal surgery likely reflect industry's influence on the research community. Such partnership alleviates financial burden and provides accessibility to cutting-edge innovation. It is essential that all parties remain mindful of the significant bias that funding source may impart on study outcome.

6.
J ISAKOS ; 7(6): 195-200, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36182072

RESUMO

PURPOSE: The purpose of the current study was to measure extrusion of the intact lateral meniscus as a function of knee flexion angle and loading condition and to compare the changes in extrusion with a posterior root tear using a robotic testing system and ultrasound. STUDY DESIGN: Controlled laboratory study. METHODS: Eight fresh-frozen cadaveric knees were subjected to external loading conditions (passive path position (no external load), 200 axial compression, 5-N-m internal tibial torque, 5-N-m valgus torque) at full extension, 30°, 60° and 90° of flexion using a robotic testing system. A linear array transducer was placed in the longitudinal orientation. Extrusion and kinematics data were recorded for two meniscus states: intact and posterior lateral root deficiency. Therefore, a complete radial root tear in the lateral meniscus at 10 mm from the tibial insertion was made in all 8 cadaveric knees using arthroscopy. The resultant forces in the lateral meniscus were also quantified by reproducing recorded paths after the removal of the lateral meniscus. RESULTS: A lateral meniscus root tear resulted in a statistically significant increase (up to 250%) of extrusion for the lateral meniscus (p < 0.05) in comparison to the intact lateral meniscus for all externally applied loads. Without external load (passive path position), significant differences were also found between the intact and posterior lateral root deficient meniscus except at full extension (1.0 ± 0.7 mm vs. 1.9 ± 0.4 mm) and 30° of flexion (1.4 ± 0.5 mm vs. 1.8 ± 0.5 mm). Overall, with increasing flexion angle, lateral meniscus extrusion decreased for the intact as well as for the posterior lateral root deficient meniscus, with the lowest measurements in response to internal tibial torque at 90° of flexion (-3.3 ± 1.1 mm). Knee kinematics were similar whether intact or posterior lateral root tear (n.s.). Ultrasound measurement of lateral meniscus extrusion showed good inter-rater (0.65 [0.30-0.97]-0.71 [0.34-0.94]) and excellent intra-rater reliability (0.81 [0.43-0.99]). CONCLUSION: Dynamic Ultrasound is a reliable diagnostic modality to measure the lateral meniscus extrusion which can be helpful in the diagnosis and quantification of lateral meniscal root tears. LEVEL OF EVIDENCE: III.


Assuntos
Traumatismos do Joelho , Lacerações , Lesões do Menisco Tibial , Humanos , Meniscos Tibiais/diagnóstico por imagem , Lesões do Menisco Tibial/diagnóstico por imagem , Reprodutibilidade dos Testes , Ruptura , Cadáver
7.
Arthrosc Tech ; 11(7): e1149-e1155, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35936857

RESUMO

Ischiofemoral impingement is a relatively rare cause of posterior hip pain associated with narrowing of the space between the lateral aspect of the ischium and the lesser trochanter. Symptoms typically consist of lower buttock, groin, and/or medial thigh pain, which is commonly exacerbated by adduction, extension, and external rotation of the hip. This condition can be treated nonoperatively in many circumstances; however, recalcitrant cases may require surgical intervention. Whereas described operative treatment options for this pathology range from endoscopic to open procedures, this Technical Note describes a safe and reliable technique for open ischiofemoral decompression with sciatic nerve neurolysis through a posterior approach for treatment of ischiofemoral impingement refractory to conservative treatment.

8.
J Pediatr Orthop ; 42(3): e257-e261, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34999631

RESUMO

BACKGROUND: Thread delamination associated with cannulated screws have been reported but likely represent an under-recognized complication in the orthopaedic literature. The purpose of this study is to report the occurrence of repeated hardware failures through thread delamination in the setting of a commonly used orthopaedic cannulated screw implant in a small cohort involving pediatric fracture care at a single academic level I trauma center. METHODS: Between August 2015 and December 2020, 9 cases of hardware failure associated with 4.5 mm arbeitsgemeinschaft für osteosynthesefragen cannulated stainless-steel screws were identified within a pediatric orthopaedic division at a single academic level I trauma center. Three cases were excluded, and 6 cases of thread delamination were retrospectively reviewed. RESULTS: Six cases of thread delamination comprised a cohort of patients with a mean age of 13.7 years (range: 12 to 15 y). All cases involved 4.5 mm arbeitsgemeinschaft für osteosynthesefragen cannulated screws, including 5 partially threaded and 1 fully threaded screw. Five cases involved open reduction and internal fixation of incarcerated medial humeral epicondylar fragments and the other case was an open reduction and internal fixation of a displaced medial malleolar fracture. Five of these occurred within a recent 18-month period of time. There were 4 cases of partial, distal thread delamination, 1 case of partial proximal thread delamination and another case of complete thread delamination which had unwound into the tibiotalar joint and required an anterior ankle arthrotomy to retrieve the thread. None of the 5 patients in this series who currently harbor a retained thread have experienced symptoms because of this issue. CONCLUSIONS: Thread delamination associated with cannulated screw implantation likely represents an under-reported phenomenon in orthopaedic surgery. In cases where retained, delaminated threads exist, these do not appear to cause short-term concern. LEVEL OF EVIDENCE: Level IV-case series.


Assuntos
Fraturas do Tornozelo , Parafusos Ósseos , Adolescente , Articulação do Tornozelo , Criança , Fixação Interna de Fraturas , Humanos , Estudos Retrospectivos
9.
Orthop J Sports Med ; 9(11): 23259671211054108, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34790834

RESUMO

BACKGROUND: Many graft fixation techniques are utilized for full-thickness soft tissue quadriceps tendon autografts during anterior cruciate ligament reconstruction (ACLR). PURPOSE: To determine the tensile properties of all-soft tissue quadriceps tendon graft fixation using a tied-suture versus continuous-loop tape technique. It was hypothesized that the continuous-loop tape technique would have less cyclic elongation and greater ultimate load to failure and stiffness compared with a commonly used tied-suture technique. STUDY DESIGN: Controlled laboratory study. METHODS: Sixteen fresh-frozen human knee specimens were used to harvest a full-thickness all-soft tissue quadriceps tendon graft; half were secured using a Krackow suture technique with 2 braided sutures, and half were secured using a continuous-loop tape suspensory fixation button with a rip-stop stitch. Cyclic and permanent elongation, toe- and linear-region stiffness, and ultimate load were determined. Statistical analysis was performed at P <.05. RESULTS: The tied-suture fixation group demonstrated significantly higher permanent elongation (11.7 ± 3.6 vs 4.2 ± 1.0 mm, P < .001) and cyclic elongation (5.9 ± 1.3 vs 2.0 ± 0.4 mm, P < .001) compared with the continuous-loop tape fixation group. There was a significantly higher linear-region stiffness with continuous-loop tape fixation compared with tied-suture fixation (98.8 ± 12.7 vs 85.5 ± 7.5 N/mm, P = .022). No significant difference in ultimate load between groups (517.1 ± 149.2 vs 465.6 ± 64.6 N) was found. The mode of failure was tendon pull-through for the continuous-loop tape group and suture breakage in the tied-suture group (P < .001). CONCLUSION: Continuous-loop tape fixation is superior to tied-suture fixation in regard to elongation and stiffness for all-soft tissue quadriceps tendon grafts, but there was no significant difference in ultimate load. CLINICAL RELEVANCE: Continuous-loop tape fixation of all-soft tissue quadriceps tendon grafts for ACLR is a valid technique with superior tensile properties.

10.
Injury ; 52(8): 2148-2153, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33812702

RESUMO

SIGNIFICANCE: Financial relationships between industry and physicians are a key aspect for the advancement of surgical practice and training, but these relationships also result in a conflict of interest with respect to research. Financial payments to physicians are public within the United States in the Open Payments Database, but the rate of accurate financial disclosure of payments has not previously been studied in trauma surgery publications. OBJECTIVE: To determine the rate of accurate financial disclosure in major surgical trauma journals compared with the Open Payments Database. MATERIALS AND METHODS: The names of all authors publishing in The Journal of Orthopaedic Trauma, Injury, and The Journal of Trauma and Acute Care Surgery between 2015 and 2018 were obtained from MEDLINE. Non-physicians, physicians outside of the United States, physicians without payments in the Open Payments Database, and physicians with payments types of only "Food and Drink" were excluded. Financial disclosure statements were obtained from the journal websites and manually compared against Open Payments Database entries the year prior to submission and during the year of submission up until 3 months prior to publication for each individual physician. Main outcomes were accuracy of disclosure published with each article, total amount of payments received (disclosure or undisclosed), surgical subspecialty of the reporting physician. Statistical comparisons were made using Chi-square testing with significance defined as p<0.05. RESULTS: Between 2015 and 2018, 5070 articles were published involving 28,948 authors. 2945 authors met inclusion criteria. 490 authors accurately disclosed their financial relationships with industry (16.6%). The median value of undisclosed payments was $22,140 [IQR $6465, $77,221] which was significantly less than the medial value of disclosed payment of $66,433 [IQR $24,624, $161,886], p<0.001 Orthopaedic surgeons disclosed at a higher rate (26.3%, 479/1818) than general surgeons (4.8%, 47/971), p<0.001. CONCLUSIONS: Physician-industry relationships are key for advancing surgical practice and providing training to physicians. These relationships are not inherently unethical, but there is consistently high inaccuracy of financial disclosure across multiple trauma surgery journals which may indicate the need for further education on financial disclosures during surgical training or active obtainment of publicly available financial disclosures by journals.


Assuntos
Ortopedia , Médicos , Conflito de Interesses , Bases de Dados Factuais , Revelação , Humanos , Estados Unidos
11.
J Am Acad Orthop Surg ; 29(11): 455-461, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33620174

RESUMO

The interactions between physicians and industry are necessary for advancement of clinical practice and improvement in medical devices. Physician-industry relationships also introduces financial conflicts of interest into research publications. Payments to physicians do not inherently introduce bias in research, but failure to disclose potential conflicts of interest can negatively impact the perceived integrity of authors, editors, and journals. The conflict of interest disclosure statement in all articles published in the Journal of the American Academy of Orthopaedic Surgery between 2014 and 2018 were compared to the financial payments indexed in the Center for Open Payments Database. Payment type, magnitude, and payer were obtained for each payment meeting inclusion criteria. Statistical comparisons were made using Mann-Whitney comparisons due to non-normal distribution of payment amounts. 704 articles involving 2596 authors were reviewed, with 1268 authors meeting inclusion criteria. 634 authors had accurate disclosure statements. The total amount of disclosed payments was $169 million, whereas undisclosed payments were $14.2 million. The amount of disclosed payments on a per-author basis, $55,844 ($12,559, $186,129), was significantly greater than undisclosed payments, $2,171 ($568, $7,238). The lowest rates of correct disclosure were in education (29.2%), gifts (38.7%) and honoraria (57.8%). First and middle authors disclosed correctly at a significantly lower rate than last authors. The magnitude of undisclosed payments was significantly lower than disclosed payments, indicating that these payments do not register with authors as significant enough to disclose.


Assuntos
Conflito de Interesses , Médicos , Estudos Transversais , Revelação , Humanos , Publicações , Estados Unidos
12.
Injury ; 52(3): 414-418, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33593524

RESUMO

INTRODUCTION: Peritrochanteric fractures are a growing problem and complications relating to operative fixation of these fracture, including varus collapse and screw cutout, are common in elderly osteoporotic patients. We hypothesize that unlocked nails will demonstrate increased varus collapse and inferior construct stiffness in specimens with increased diaphyseal medullary diameter. MATERIALS AND METHODS: Sixteen non-cadaveric osteoporotic biomechanical femur specimens were utilized in this study, with eight specimens having an artificially large femoral canal to represent Dorr C femurs. All femurs were instrumented with a short cephalomedullary nail with and without distal cross-lock screw fixation and had an unstable intertrochanteric fracture created in a repeatable pattern. Specimens underwent cyclic compression to a maximal load of 1000N with segmental motion quantified through the use of visual tracking markers. Statistical comparisons were performed using one-way ANOVA with Tukey post-hoc analysis to determine differences between specific groups. Significance was defined as p<0.05. RESULTS: Unlocked short cephalomedullary nails showed increased varus collapse due to motion of the nail within the femoral canal in capacious femoral canals compared with narrow femoral canals and distally cross-locked nails. The coronal deformation of the wide canal unlocked group (17.9 o±2.6o) was significantly greater in the varus direction than any other fixation under compressive load of 1000N. There was no significant difference in varus angulation between the wide canal or narrow canal locked groups (11.1o±8.7o vs. 8.2o±1.7o respectively, p=0.267). The narrow canal unlocked group (13.7o±2.4o) showed significantly greater varus angulation than the narrow canal locked (p=0.015). The wide canal unlocked group showed significantly greater varus angulation than the wide canal locked group (p=0.003). Motion between the femoral shaft and the cephalomedullary nail (toggling of the nail within the shaft) was significantly greater in narrow or wide canal unlocked specimens, 7.94o±2.13o and 10.2o±1.7o respectively, than in the narrow or wide canal locked specimens, 2.4o±0.2o and 4.2o±0.5o respectively (p<0.05) CONCLUSION: Unlocked short intramedullary fixation for unstable peritrochanteric fractures results in increased varus collapse under axial compression. This study supports the use of distal cross-locking of short intramedullary fixation for unstable peritrochanteric fractures in patients with capacious femoral canals secondary to osteoporosis who might otherwise be as risk for varus collapse, device failure, and malunion.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Fraturas do Quadril , Idoso , Fenômenos Biomecânicos , Pinos Ortopédicos , Parafusos Ósseos , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Humanos , Unhas
13.
J Pediatr ; 232: 207-213.e2, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33453206

RESUMO

OBJECTIVE: To determine the association between bacteremia and vaccination status in children aged 2-36 months presenting to a pediatric emergency department. STUDY DESIGN: Retrospective cohort study of children aged 2-36 months with blood cultures obtained in the pediatric emergency department between January 2013 and December 2017. The exposure of interest was immunization status, defined as number of Haemophilus influenzae type B (Hib) and Streptococcus pneumoniae vaccinations, and the main outcome positive blood culture. Subjects with high-risk medical conditions were excluded. RESULTS: Of 5534 encounters, 4742 met inclusion criteria. The incidence of bacteremia was 1.5%. The incidence of contaminated blood culture was 5.0%. The relative risk of bacteremia was 0.79 (95% CI 0.39-1.59) for unvaccinated and 1.20 (95% CI 0.52-2.75) for undervaccinated children relative to those who had received age-appropriate vaccines. Five children were found to have S pneumoniae bacteremia and 1 child had Hib bacteremia; all of these subjects had at least 3 sets of vaccinations. No vaccine preventable pathogens were isolated from blood cultures of unvaccinated children. We found no S pneumoniae or Hib in children 2-6 months of age who were not fully vaccinated due to age (95% CI 0-0.13%) and the contamination rate in this group was high compared with children 7-36 months (6.6% vs 3.7%). CONCLUSIONS: Bacteremia in young children is an uncommon event. Contaminated blood cultures were more common than pathogens. Bacteremia from S pneumoniae or Hib is uncommon and, in this cohort, was independent of vaccine status.


Assuntos
Bacteriemia/prevenção & controle , Infecções por Haemophilus/prevenção & controle , Vacinas Anti-Haemophilus , Haemophilus influenzae tipo b , Infecções Pneumocócicas/prevenção & controle , Vacinas Pneumocócicas , Cobertura Vacinal/estatística & dados numéricos , Bacteriemia/diagnóstico , Bacteriemia/epidemiologia , Bacteriemia/etiologia , Pré-Escolar , Serviço Hospitalar de Emergência , Feminino , Infecções por Haemophilus/diagnóstico , Infecções por Haemophilus/epidemiologia , Infecções por Haemophilus/etiologia , Haemophilus influenzae tipo b/isolamento & purificação , Humanos , Incidência , Lactente , Masculino , New England/epidemiologia , Infecções Pneumocócicas/diagnóstico , Infecções Pneumocócicas/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
14.
Am J Sports Med ; 48(14): 3495-3502, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33176107

RESUMO

BACKGROUND: The pivot-shift test is used to assess for rotatory knee laxity in the anterior cruciate ligament (ACL)-deficient knee and ACL-reconstructed knee; however, the pivot shift uses a subjective grading system that is limited by variability between examiners. Consequently, quantified pivot shift (QPS) test software (PIVOT iPad application) has been developed and validated to measure the magnitude of rotatory knee laxity during the positive pivot-shift test. PURPOSE: To employ intraoperative QPS (iQPS) to assess for differences in residual rotatory knee laxity after ACL reconstruction (ACLR) versus ACLR augmented with lateral extra-articular tenodesis (ACLR + LET), and to employ iQPS to determine if ACLR and/or ACLR + LET result in overconstrained knee kinematics when compared with the contralateral knee. STUDY DESIGN: Cohort study; Level of evidence, 2. METHODS: iQPS was performed in 20 patients by a single surgeon on both the operative and contralateral knees before ACLR. ACLR was augmented with a LET if the lateral compartment tibial translation measured during QPS was greater than or equal to double the amount of lateral tibial compartment translation measured for the contralateral knee. After each reconstruction (ACLR or ACLR + LET), iQPS measurements were performed. iQPS data were compared with the preoperative QPS measurements of the operative and contralateral knees. Postoperative iQPS data were compared with both the preoperative QPS measurements of the operative and contralateral knees with paired samples t tests. Categorical variables were compared using the Fisher exact test. RESULTS: The mean age in the cohort was 17.3 years (range, 15-24 years). There were no significant differences between the groups in terms of the proportion of male patients (ACLR: 5 male, 5 female vs ACLR + LET: 4 male, 6 female) or age (ACLR: 17.7 ± 3.3 years; 95% CI, 15.4-24.0 vs ACLR + LET: 16.8 ± 2.8 years, 95% CI, 14.8-22.0; P = .999). There were no significant differences between the groups with respect to preoperative QPS performed during examination under anesthesia (ACLR: 4.7 ± 2.0 mm; 95% CI, 3.3-6.1 vs ACLR + LET: 3.6 ± 1.8 mm; 95% CI, 2.3-4.9; P = .2). Both ACLR and ACLR + LET resulted in significant decreases in rotatory knee laxity when compared with preoperative QPS measurements (ACLR: -3.4 ± 1.7 mm; 95% CI, -4.6 to -2.2; P < .001: ACLR + LET: -2.6 ± 1.9 mm; 95% CI, -3.9 to -1.3; P < .002). Moreover, when compared with isolated ACLR, ACLR + LET did not result in a significantly smaller magnitude of change in iQPS between the pre- and postoperative states (P = .3). CONCLUSION: Both ACLR and ACLR + LET resulted in significant decreases in rotatory knee laxity. The augmentation of ACLR with LET did not change the constraint of the knee with respect to lateral compartment translation as measured during iQPS.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Instabilidade Articular , Tenodese , Adolescente , Adulto , Lesões do Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Estudos de Coortes , Feminino , Humanos , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Masculino , Amplitude de Movimento Articular , Rotação , Software , Cirurgia Assistida por Computador , Adulto Jovem
15.
Spine (Phila Pa 1976) ; 45(21): 1524-1529, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-32628433

RESUMO

STUDY DESIGN: Cohort study. OBJECTIVE: The aim of this study was to determine the rate of accurate conflict of interest (COI) disclosure within three prominent subspecialty Spine journals during a 4-year period. SUMMARY OF BACKGROUND DATA: Industry-physician relationships are crucial for technological advancement in spine surgery but serve as a source of bias in biomedical research. The Open Payments Database (OPD) was established after 2010 to increase financial transparency. METHODS: All research articles published from 2014 to 2017 in Spine, The Spine Journal (TSJ), and the Journal of Neurosurgery: Spine (JNS) were reviewed in this study. In these articles, all author's COI statements were recorded. The OPD was queried for all author entries within the disclose period of the journal. Discrepancies between the author's self-reported COIs and the documented COIs from OPD were recorded. RESULTS: A total of 6816 articles meeting inclusion criteria between 2014 and 2017 in Spine, TSJ, and JNS with 39,869 contributing authors. Overall, 15.8% of all authors were found to have an OPD financial relationship. Of 2633 authors in Spine with financial disclosures, 77.1% had accurate financial disclosures; 42.5% and 41.0% of authors with financial relationships in the OPD had accurate financial disclosures in TSJ and JNS, respectively. The total value of undisclosed conflicts of interest between 2014 and 2017 was $421 million with $1.48 billion in accurate disclosures. Of undisclosed payments, 68.7% were <$1000 and only 7.2% were >$10,000. Undisclosed payments included $180 million in research funding and $188 million in royalties. CONCLUSION: This study demonstrates that undisclosed COI is highly prevalent for authors in major Spine journals. This study indicates that there remains a need to standardize definitions and financial thresholds for significant COI as well as to shift the reporting burden for COI to journals who actively review potential COIs instead of relying on self-reporting. LEVEL OF EVIDENCE: 3.


Assuntos
Conflito de Interesses , Revelação/normas , Publicações Periódicas como Assunto/normas , Médicos/normas , Doenças da Coluna Vertebral , Pesquisa Biomédica/economia , Pesquisa Biomédica/normas , Estudos de Coortes , Conflito de Interesses/economia , Bases de Dados Factuais/normas , Humanos , Publicações Periódicas como Assunto/economia , Médicos/economia , Autorrelato/economia , Autorrelato/normas , Doenças da Coluna Vertebral/economia , Doenças da Coluna Vertebral/cirurgia
16.
Arthrosc Tech ; 9(5): e603-e609, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32489833

RESUMO

Anterior cruciate ligament reconstruction using quadriceps tendon (QT) autograft has recently gained popularity because newer techniques allow harvest of a robust graft with little soft-tissue dissection or donor-site morbidity. The QT graft can provide a safe, reproducible, and versatile option for primary and revision anterior cruciate ligament reconstruction with equivalent outcomes and failure rates to those of bone-patellar tendon-bone and hamstring tendon grafts. Therefore, continued improvement in surgical technique may help to further improve patient outcomes. This study introduces a modification of current QT techniques using a partial-thickness graft with continuous-loop EndoButton fixation (Smith & Nephew, Andover, MA).

17.
J Biomech ; 99: 109508, 2020 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-31813563

RESUMO

Acute and chronic whiplash-associated disorders pose a significant healthcare burden due to chronic pain, which is associated with upper cervical instability resulting from ligamentous injury. No standard measure exists for diagnosing alar ligament injury and imaging findings vary widely. Multiple physical examination maneuvers are used to diagnose alar ligament injury including the C2 Spinous Kick, Flexion-Rotation, and Bending-Rotation tests. The objective of the current study was to determine the mechanical contribution of the alar ligaments to upper cervical stability and quantify the biomechanical changes seen during simulated clinical examinations after alar ligament injury. Eight cadaveric C0-C3 specimens were evaluated using a robotic testing system. Range of motion and moment at the end of intact specimen replay were the primary outcomes. Clinical examinations were simulated by rotation through two axes as performed during physical examination. Intact, unilateral and bilateral alar ligament injury states were tested. Unilateral alar ligament injury led to significant increases in lateral bending (12.0 ± 7.2%, p < 0.05), axial rotation (4.1 ± 2.4%, p < 0.05), and flexion-extension (5.3 ± 4.3%, p < 0.05) compared with intact specimens. The alar ligaments also contributed to resistance to intact motion in extension (13.4 ± 6.6%, p < 0.05), flexion (4.4 ± 2.2%, p < 0.05), axial rotation (19.3 ± 2.7%, p < 0.05), and lateral bending (16.0 ± 2.8%, p < 0.05). The C2 Spinous Kick Test showed the largest percentage change (-23.0 ± 14.8%), and the Bending-Rotation Test towards the side of injury significantly increased axial rotation by the largest absolute magnitude (5.5° ± 5.1°). Overall, quantifiable changes to motion measured during simulated physical examinations were found, but the ability of a clinician to feel these changes remains unknown.


Assuntos
Vértebras Cervicais/lesões , Ligamentos Articulares/lesões , Fenômenos Mecânicos , Fenômenos Biomecânicos , Vértebras Cervicais/fisiologia , Feminino , Humanos , Ligamentos Articulares/fisiologia , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Rotação
18.
Curr Rev Musculoskelet Med ; 12(4): 472-478, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31773476

RESUMO

PURPOSE OF REVIEW: In the setting of rotatory knee instability following anterior cruciate ligament (ACL) reconstruction, there has been a resurgence of interest in knee's anterolateral complex (ALC). Reconstruction or augmentation of the ALC with procedures such as a lateral extra-articular tenodesis (LET) has been proposed to reduce rotatory knee instability in conjunction with ACL reconstruction. The current review investigates the recent literature surrounding the role of the ALC in preventing rotatory knee instability. RECENT FINDINGS: The knee's anterolateral complex (ALC) is a complex structure composed of the superficial and deep portions of the iliotibial band, the capsulo-osseous layer, and the anterolateral capsule. Distally, these various layers merge to form a single functional unit which imparts stability to the lateral knee. While the iliotibial band and the capsule-osseous layer have been shown to be primary restraints to rotatory motion after ACL injury, the biomechanical role of the anterolateral capsule remains unclear. Biomechanical studies have shown that the anterolateral capsule and the anterolateral thickening of this capsule act as a sheet of fibrous tissue which does not resist motion around the knee as other longitudinally oriented ligaments do. Augmentation of the ALC, with LET, has been performed globally for over 30 years. This procedure can decrease rotatory knee instability, but long-term studies have found little difference in patient-reported outcomes, osteoarthritis, or ACL reconstruction failure with the addition of LET. Further research is needed to clarify indications for the clinical use of ALC-based procedures.

19.
J Healthc Eng ; 2019: 9535070, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31281619

RESUMO

Early-onset scoliosis (EOS) remains a challenging condition for which current nonfusion surgeries require iterative lengthening surgeries. A growing rod with sliding pedicle screw system (GRSPSS) was developed to treat spinal deformities without repeated operative lengthening. This study was performed to evaluate whether GRSPSS had similar stability as a conventional pedicle screw system to maintain deformity correction. A serial-linkage robotic manipulator with a six-axis load cell positioned on the end-effector was utilized to evaluate the mechanical stability of the GRSPSS versus conventional fixed scoliosis instrumentation. Ten skeletally mature thoracic female Katahdin sheep spines (T4-L1) were subjected to 2.5 Nm of flexion-extension (FE), lateral bending (LB), and axial rotation (AR) in 2° increments for each state. The overall range of motion (ROM), apical segment ROM, and stiffness were calculated and reported. A two-tailed paired t-test was used to detect significant differences (p < 0.05) between the fixed group and GRSPSS fixation. There were no significant differences in overall range of motion (ROM), apical segment ROM, or stiffness for FE or LB between the GRSPSS group and fixed group. In AR, the GRSPSS group showed increased ROM compared to the fixed group for the overall spine (36.0° versus 19.2°, p < 0.01) and for the instrumented T8-T10 segments (7.0° versus 2.9°, p=0.02). Similarly, the fixed rod elastic zone (EZ) stiffness was significantly greater than the GRSPSS EZ stiffness (0.29 N/m versus 0.17 N/m, p < 0.001). The space around the rod allows for the increased AR observed with the GRSPSS fusion technique and is necessary for axial growth. The GRSPSS fusion model shows equivalent flexion and LB stability to current fusion models and represents a stable fusion technique and may allow for longitudinal growth during childhood.


Assuntos
Parafusos Pediculares , Escoliose/cirurgia , Coluna Vertebral/cirurgia , Animais , Fenômenos Biomecânicos , Feminino , Fixadores Internos , Vértebras Lombares/cirurgia , Amplitude de Movimento Articular , Robótica , Ovinos , Fusão Vertebral/métodos , Estresse Mecânico , Vértebras Torácicas/cirurgia
20.
Knee Surg Sports Traumatol Arthrosc ; 27(6): 1882-1890, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30888445

RESUMO

PURPOSE: Allografts are frequently use for ligamentous reconstruction at the knee. In the United States, tissue donation and distribution are highly regulated processes with thorough oversight from private and government entities. Allograft is widely available in the United States and allograft procurement is a large industry with varying procurement, sterilization, processing, and distribution procedures. It is important to understand allograft regulation and processing which may affect graft mechanical properties and biological graft integration. METHODS: English-language literature, United States government and regulatory agency statues pertaining to allograft procurement, distribution, and usage were reviewed and the findings summarized. RESULTS: During the processing of allograft, multiple factors including sterilization procedures, irradiation, storage conditions, and graft type all affect the biomechanical properties of the allograft tissue. Biological incorporation and ligamentization of allograft does occur, but at a slower rate compared with autograft. For ligamentous reconstruction around the knee, allograft offers shorter operative time, no donor-site morbidity, but has shown an increased risk for graft failure compared to autograft. CONCLUSION: This article reviews the regulations on graft tissue within the United States, factors affecting the biomechanics of allograft tissue, differences in allograft tissue choices, and the use of allograft for anterior cruciate ligament reconstruction and multiligamentous knee injury reconstruction. LEVEL OF EVIDENCE: V.


Assuntos
Aloenxertos , Regulamentação Governamental , Articulação do Joelho/cirurgia , Tendões/transplante , Transplante Homólogo , Humanos , Ligamentos Articulares/lesões , Ligamentos Articulares/cirurgia , Manejo de Espécimes/normas , Esterilização/métodos , Coleta de Tecidos e Órgãos/legislação & jurisprudência , Obtenção de Tecidos e Órgãos/legislação & jurisprudência , Transplante Homólogo/legislação & jurisprudência , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...