1.
Int J Mol Sci ; 24(8)2023 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-37108443

RESUMO

The causes of heart valve bioprosthetic calcification are still not clear. In this paper, we compared the calcification in the porcine aorta (Ao) and the bovine jugular vein (Ve) walls, as well as the bovine pericardium (Pe). Biomaterials were crosslinked with glutaraldehyde (GA) and diepoxide (DE), after which they were implanted subcutaneously in young rats for 10, 20, and 30 days. Collagen, elastin, and fibrillin were visualized in non-implanted samples. Atomic absorption spectroscopy, histological methods, scanning electron microscopy, and Fourier-transform infrared spectroscopy were used to study the dynamics of calcification. By the 30th day, calcium accumulated most intensively in the collagen fibers of the GA-Pe. In elastin-rich materials, calcium deposits were associated with elastin fibers and localized differences in the walls of Ao and Ve. The DE-Pe did not calcify at all for 30 days. Alkaline phosphatase does not affect calcification since it was not found in the implant tissue. Fibrillin surrounds elastin fibers in the Ao and Ve, but its involvement in calcification is questionable. In the subcutaneous space of young rats, which are used to model the implants' calcification, the content of phosphorus was five times higher than in aging animals. We hypothesize that the centers of calcium phosphate nucleation are the positively charged nitrogen of the pyridinium rings, which is the main one in fresh elastin and appears in collagen as a result of GA preservation. Nucleation can be significantly accelerated at high concentrations of phosphorus in biological fluids. The hypothesis needs further experimental confirmation.


Assuntos
Bioprótese , Calcinose , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Ratos , Animais , Bovinos , Suínos , Elastina , Cálcio , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Calcinose/patologia , Glutaral , Colágeno , Fósforo , Pericárdio/patologia
2.
Biomedicines ; 10(1)2021 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-35052745

RESUMO

Calcification is the major factor limiting the clinical use of bioprostheses. It may be prevented by the immobilization of bisphosphonic compounds (BPs) on the biomaterial. In this study, we assessed the accumulation and structure of calcium phosphate deposits in collagen-rich bovine pericardium (Pe) and elastin-rich porcine aortic wall (Ao) and bovine jugular vein wall (Ve) cross-linked with glutaraldehyde (GA) or diepoxy compound (DE). These tissues were then modified with pamidronic (PAM) acid or 2-(2'-carboxyethylamino)ethylidene-1,1-bisphosphonic (CEABA) acid. Tissue transformations were studied using Fourier-transform infrared spectroscopy. After subcutaneous implantation of the biomaterials in 220 rats, calcification dynamics were examined using atomic absorption spectrophotometry, light microscopy after von Kossa staining, and scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy The calcium content in all GA-cross-linked tissues and DE-cross-linked Ao increased to 100-160 mg/g on day 60 after implantation. BPs prevented the accumulation of phosphates on the surface of all materials and most effectively inhibited calcification in GA-cross-linked Ao and DE-cross-linked Pe. PAM containing -OH in the R1 group was more effective than CEABA containing -H in R1. The calcification-inhibitory effect of BPs may be realized through their ability to block nucleation and prevent the growth of hydroxyapatite crystals.

3.
Mater Sci Eng C Mater Biol Appl ; 118: 111473, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33255052

RESUMO

Bioprosthetic heart valves made from bovine pericardium (BP) and porcine pericardium (PP) preserved with glutaraldehyde (GA) are commonly used in valve surgeries but prone to calcification in many patients. In this study, we compared BP and PP preserved with GA, ethylene glycol diglycidyl ether (DE), and 1,2,3,4,6-penta-O-{1-[2-(glycidyloxy)ethoxy]ethyl}-d-glucopyranose (PE). We studied the stabilities of DE and PE in preservation media along with the amino acid (AA) compositions, Fourier-transform infrared spectra, mechanical properties, surface morphologies, thermal stability, calcification, and the cytocompatibility of BP and PP treated with 0.625% GA, 5% DE, 2% PE, and alternating 5% DE and 2% PE for 3 + 11 d and 10 + 10 d, respectively. Both epoxides were stable in the water-buffer solutions (pH 7.4). DE provided high linkage densities in BP and PP owing to reactions with Hyl, Lys, His, Arg, Ser, and Tyr. PE reacted weakly with these AAs but strongly with Met. High cross-linking density obtained using the 10 d + 10 d method provided satisfactory thermal stability of biomaterials. The epoxy preservations improved cytocompatibility and resistance to calcification. PE enhanced the stress/strain properties of the xenogeneic pericardia, perhaps by forming nanostructures that were clearly visualised in BP using scanning electron microscopy. The DE + PE combination, in an alternating cross-linking manner, thus constitutes a promising option for developing bioprosthetic pericardia.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Animais , Bovinos , Reagentes de Ligações Cruzadas , Glutaral , Humanos , Pericárdio , Suínos
4.
ACS Appl Mater Interfaces ; 10(15): 13062-13072, 2018 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-29589896

RESUMO

The peculiarities of the solid-state interaction in the HfC-Ir system have been studied within the 1000-1600 °C temperature range using a set of modern analytical techniques. It was stated that the interaction of HfC with iridium becomes noticeable at temperatures as low as 1000-1100 °C and results in the formation of HfIr3-based substitutional solid solution. The homogeneity range of the HfIr3± x phase was evaluated and refined as HfIr2.43-HfIr3.36. The durability of the HfIr3-based system under extreme environmental conditions was studied. It was shown that the HfIr3-based material displays excellent ablation resistance under extreme environmental conditions. The benefits of the new designed material result from its relative oxygen impermeability and special microstructure similar to superalloys. The results obtained in this work allow us to consider HfIr3 as a very promising candidate for extreme applications.