Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Immun Ageing ; 20(1): 30, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37393237

RESUMO

BACKGROUND: Adjuvanted inactivated influenza vaccine (aIIV) and high-dose inactivated influenza vaccine (HD-IIV) are U.S.-licensed for adults aged ≥ 65 years. This study compared serum hemagglutination inhibition (HAI) antibody titers for the A(H3N2) and A(H1N1)pdm09 and B strains after trivalent aIIV3 and trivalent HD-IIV3 in an older adult population. RESULTS: The immunogenicity population included 342 participants who received aIIV3 and 338 participants who received HD-IIV3. The proportion of participants that seroconverted to A(H3N2) vaccine strains after allV3 (112 participants [32.8%]) was inferior to the proportion of participants that seroconverted after HD-IIV3 (130 participants [38.5%]) at day 29 after vaccination (difference, - 5.8%; 95%CI, - 12.9% to 1.4%). There were no significant differences between the vaccine groups in percent seroconversion to A(H1N1)pdm09 or B vaccine strains, in percent seropositivity for any of the strains, or in post-vaccination GMT for the A(H1N1)pdm09 strain. The GMTs for the post-vaccination A(H3N2) and B strains were higher after HD-IIV than after aIIV3. CONCLUSIONS: Overall immune responses were similar after aIIV3 and HD-IIV3. For the primary outcome, the aIIV3 seroconversion rate for H3N2 did not meet noninferiority criteria compared with HD-IIV3, but the HD-IIV3 seroconversion rate was not statistically superior to the aIIV3 seroconversion rate. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03183908.

2.
Pediatrics ; 145(3)2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32029684

RESUMO

BACKGROUND: Administering inactivated influenza vaccine (IIV), 13-valent pneumococcal conjugate vaccine (PCV13), and diphtheria-tetanus-acellular pertussis (DTaP) vaccine together has been associated with increased risk for febrile seizure after vaccination. We assessed the effect of administering IIV at a separate visit from PCV13 and DTaP on postvaccination fever. METHODS: In 2017-2018, children aged 12 to 16 months were randomly assigned to receive study vaccines simultaneously or sequentially. They had 2 study visits 2 weeks apart; nonstudy vaccines were permitted at visit 1. The simultaneous group received PCV13, DTaP, and quadrivalent IIV (IIV4) at visit 1 and no vaccines at visit 2. The sequential group received PCV13 and DTaP at visit 1 and IIV4 at visit 2. Participants were monitored for fever (≥38°C) and antipyretic use during the 8 days after visits. RESULTS: There were 110 children randomly assigned to the simultaneous group and 111 children to the sequential group; 90% received ≥1 nonstudy vaccine at visit 1. Similar proportions of children experienced fever on days 1 to 2 after visits 1 and 2 combined (simultaneous [8.1%] versus sequential [9.3%]; adjusted relative risk = 0.87 [95% confidence interval 0.36-2.10]). During days 1 to 2 after visit 1, more children in the simultaneous group received antipyretics (37.4% vs 22.4%; P = .020). CONCLUSIONS: In our study, delaying IIV4 administration by 2 weeks in children receiving DTaP and PCV13 did not reduce fever occurrence after vaccination. Reevaluating this strategy to prevent fever using an IIV4 with a different composition in a future influenza season may be considered.


Assuntos
Vacinas contra Difteria, Tétano e Coqueluche Acelular/efeitos adversos , Febre/etiologia , Vacinas contra Influenza/efeitos adversos , Vacinas Pneumocócicas/efeitos adversos , Vacinas contra Difteria, Tétano e Coqueluche Acelular/administração & dosagem , Feminino , Humanos , Lactente , Vacinas contra Influenza/administração & dosagem , Masculino , Vacinas Pneumocócicas/administração & dosagem
3.
PLoS One ; 14(9): e0222290, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31525218

RESUMO

Laboratory assays for identifying recent HIV-1 infections are widely used for estimating incidence in cross-sectional population-level surveys in global HIV-1surveillance. Adequate assay and laboratory performance are required to ensure accurate incidence estimates. The NIAID-supported External Quality Assurance Program Oversight Laboratory (EQAPOL) established a proficiency testing program for the most widely-used incidence assay, the HIV-1 Limiting Antigen Avidity EIA (LAg), with US Centers for Disease Control and Prevention (CDC)-approved kits manufactured by Sedia Biosciences Corporation and Maxim Biomedical. The objective of this program is to monitor the performance of participating laboratories. Four rounds of blinded external proficiency (EP) panels were distributed to up to twenty testing sites (7 North American, 5 African, 4 Asian, 2 South American and 2 European). These panels consisted of ten plasma samples: three blinded well-characterized HIV-1-seropositive samples that were included as replicates and an HIV-negative control. The seropositive samples spanned the dynamic range of the assay and are categorized as either recent or long-term infection. Participating sites performed the assay according to manufacturers' instructions and completed an online survey to gather information on kit manufacturer, lot of kit used, laboratory procedures and the experience of technicians. On average, fifteen sites participated in each round of testing, with an average of four sites testing with only the Maxim assay, seven testing with only the Sedia assay and five sites utilizing both assays. Overall, the Sedia and Maxim assays yielded similar infection status categorization across the laboratories; however, for most of the nine HIV+ samples tested, there were significant differences in the optical density readouts, ODn (N = 8) and OD (N = 7), between LAg kit manufacturers (p < 0.05 based on mixed effects models. The EQAPOL LAg program is important for monitoring laboratory performance as well as detecting variations between manufacturers of HIV-1incidence assays.


Assuntos
Antígenos Virais/imunologia , Antígenos HIV/imunologia , Infecções por HIV/imunologia , Soropositividade para HIV/imunologia , HIV-1/imunologia , Ensaio de Proficiência Laboratorial/métodos , Testes Sorológicos/métodos , Estudos Transversais , Humanos , Incidência , Laboratórios , Carga Viral/imunologia
4.
Infect Dis Obstet Gynecol ; 2019: 5430493, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30853787

RESUMO

Background: Maternal GBS colonization is associated with early-onset neonatal sepsis and extensive efforts are directed to preventing this complication. Less is known about maternal risks of GBS colonization. We seek to provide a modern estimate of the incidence and impact of maternal GBS colonization and invasive GBS disease. Methods: A single center historical cohort study of all births between 2003 and 2015 was performed. Data was collected via electronic health record abstraction using an institutional specific tool. Descriptive statistics were performed regarding GBS status. Inferential statistics were performed comparing risk of adverse pregnancy outcomes in cohorts with and without GBS colonization as well as cohorts with GBS colonization and invasive GBS disease. Results: A total of 60,029 deliveries were included for analysis. Overall, 21.6% of the population was GBS colonized and 0.1% had invasive GBS disease. GBS colonization was associated with younger maternal age, Black race, non-Hispanic ethnicity, chronic hypertension, preexisting diabetes, and tobacco use (p<0.01). In the adjusted analyses, there was an increased risk of gestational diabetes (aRR 1.21, 95% CI 1.11-1.32) in colonized pregnancies and a decreased incidence of short cervix (aRR 0.64, 95% CI 0.52-0.79), chorioamnionitis (aRR 0.76, 95% CI 0.66-0.87), wound infection (aRR 0.75, 95% CI 0.64-0.88), and operative delivery (aRR 0.85, 95% CI 0.83-0.88). Conclusions: This modern-day large cohort of all births over a 12-year period demonstrates a GBS colonization rate of 21.6%. This data reflects a need to assess maternal and perinatal outcomes in addition to neonatal GBS sepsis rates to inform decisions regarding the utility of maternal vaccination.


Assuntos
Complicações Infecciosas na Gravidez/epidemiologia , Infecções Estreptocócicas/epidemiologia , Streptococcus agalactiae , Adulto , Estudos de Coortes , Feminino , História do Século XXI , Humanos , Gravidez , Complicações Infecciosas na Gravidez/história , Complicações Infecciosas na Gravidez/microbiologia , Resultado da Gravidez , Prevalência , Fatores de Risco , Infecções Estreptocócicas/história , Infecções Estreptocócicas/microbiologia , Estados Unidos/epidemiologia
5.
Vaccine ; 35(48 Pt B): 6664-6671, 2017 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-29056422

RESUMO

BACKGROUND: Antipyretics reduce fever following childhood vaccinations; after inactivated influenza vaccine (IIV) they might ameliorate fever and thereby decrease febrile seizure risk, but also possibly blunt the immune response. We assessed the effect of antipyretics on immune responses and fever following IIV in children ages 6 through 47 months. METHODS: Over the course of three seasons, one hundred forty-two children, receiving either a single or the first of 2 recommended doses of IIV, were randomized to receive either oral acetaminophen suspension (n = 59) or placebo (n = 59) (double-blinded) or ibuprofen (n = 24) (open-label) immediately following IIV and every 4-8 h thereafter for 24 h. Blood samples were obtained at enrollment and 4 weeks following the last recommended IIV dose. Responses to IIV were assessed by hemagglutination inhibition assay (HAI). Seroprotection was defined as an HAI titer ≥1:40 and seroconversion as a titer ≥1:40 if baseline titer <1:10 or four-fold rise if baseline titer ≥1:10. Participants were monitored for fever and other solicited symptoms on the day of and day following IIV. RESULTS: Significant differences in seroconversion and post-vaccination seroprotection were not observed between children included in the different antipyretic groups and the placebo group for the vaccine antigens included in IIV over the course of the studies. Frequencies of solicited symptoms, including fever, were similar between treatment groups and the placebo group. CONCLUSIONS: Significant blunting of the immune response was not observed when antipyretics were administered to young children receiving IIV. Studies with larger sample sizes are needed to definitively establish the effect of antipyretics on IIV immunogenicity.


Assuntos
Antipiréticos/administração & dosagem , Febre/tratamento farmacológico , Imunidade Ativa/efeitos dos fármacos , Vacinas contra Influenza/imunologia , Vacinas de Produtos Inativados/imunologia , Acetaminofen/administração & dosagem , Acetaminofen/efeitos adversos , Acetaminofen/sangue , Anticorpos Antivirais/sangue , Antipiréticos/efeitos adversos , Antipiréticos/sangue , Antipiréticos/imunologia , Pré-Escolar , Feminino , Testes de Inibição da Hemaglutinação , Humanos , Imunização Secundária , Lactente , Vacinas contra Influenza/administração & dosagem , Vacinas contra Influenza/efeitos adversos , Influenza Humana/prevenção & controle , Masculino , Convulsões Febris/tratamento farmacológico , Convulsões Febris/prevenção & controle , Vacinação , Vacinas de Produtos Inativados/administração & dosagem , Vacinas de Produtos Inativados/efeitos adversos
6.
J Immunol Methods ; 409: 147-60, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24607608

RESUMO

A3R5 is a human CD4(+) lymphoblastoid cell line that was engineered to express CCR5 and is useful for the detection of weak neutralizing antibody responses against tier 2 strains of HIV-1. Here we describe the optimization and validation of the HIV-1 neutralizing antibody assay that utilizes A3R5 cells, performed in compliance with Good Clinical Laboratory Practice (GCLP) guidelines. The assay utilizes Renilla luciferase-expressing replication competent infectious molecular clones (IMC) encoding heterologous env genes from different HIV-1 clades. Key assay validation parameters tested included specificity, accuracy, precision, limit of detection and quantitation, specificity, linearity and range, and robustness. Plasma samples demonstrated higher non-specific activity than serum samples in the A3R5 assay. This assay can tolerate a wide range of virus input but is more sensitive to cell concentration. The higher sensitivity of the A3R5 assay in neutralization responses to tier 2 strains of HIV-1 makes it complementary to, but not a substitute for the TZM-bl assay. The validated A3R5 assay is employed as an endpoint immunogenicity test for vaccine-elicited neutralizing antibodies against tier 2 strains of HIV-1, and to identify correlates of protection in HIV-1 vaccine trials conducted globally.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Anti-HIV/sangue , Infecções por HIV/diagnóstico , HIV-1/imunologia , Ensaios de Triagem em Larga Escala/normas , Testes de Neutralização/normas , Automação Laboratorial/normas , Biomarcadores/sangue , Linhagem Celular , Fidelidade a Diretrizes/normas , Infecções por HIV/sangue , Infecções por HIV/imunologia , HIV-1/genética , Humanos , Limite de Detecção , Variações Dependentes do Observador , Guias de Prática Clínica como Assunto/normas , Valor Preditivo dos Testes , Controle de Qualidade , Reprodutibilidade dos Testes , Fatores de Tempo , Transfecção
7.
J Immunol Methods ; 409: 91-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24120573

RESUMO

The EQAPOL contract was awarded to Duke University to develop and manage global proficiency testing programs for flow cytometry-, ELISpot-, and Luminex bead-based assays (cytokine analytes), as well as create a genetically diverse panel of HIV-1 viral cultures to be made available to National Institutes of Health (NIH) researchers. As a part of this contract, EQAPOL was required to operate under Good Clinical Laboratory Practices (GCLP) that are traditionally used for laboratories conducting endpoint assays for human clinical trials. EQAPOL adapted these guidelines to the management of proficiency testing programs while simultaneously incorporating aspects of ISO/IEC 17043 which are specifically designed for external proficiency management. Over the first two years of the contract, the EQAPOL Oversight Laboratories received training, developed standard operating procedures and quality management practices, implemented strict quality control procedures for equipment, reagents, and documentation, and received audits from the EQAPOL Central Quality Assurance Unit. GCLP programs, such as EQAPOL, strengthen a laboratory's ability to perform critical assays and provide quality assessments of future potential vaccines.


Assuntos
Citocinas/sangue , ELISPOT/normas , Citometria de Fluxo/normas , Infecções por HIV/diagnóstico , Testes de Liberação de Interferon-gama/normas , Laboratórios/normas , Ensaio de Proficiência Laboratorial/normas , Monitorização Imunológica/normas , Indicadores de Qualidade em Assistência à Saúde/normas , Vacinas contra a AIDS/uso terapêutico , Bancos de Espécimes Biológicos/normas , Biomarcadores/sangue , Certificação , Fidelidade a Diretrizes/normas , Infecções por HIV/sangue , Infecções por HIV/imunologia , Infecções por HIV/terapia , Infecções por HIV/virologia , HIV-1/genética , HIV-1/imunologia , Humanos , Laboratórios/estatística & dados numéricos , Pessoal de Laboratório/normas , Variações Dependentes do Observador , Guias de Prática Clínica como Assunto/normas , Valor Preditivo dos Testes , Desenvolvimento de Programas , Avaliação de Programas e Projetos de Saúde , Controle de Qualidade , Reprodutibilidade dos Testes , Manejo de Espécimes/normas , Fluxo de Trabalho
8.
J Immunol Methods ; 409: 131-46, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24291345

RESUMO

The TZM-bl assay measures antibody-mediated neutralization of HIV-1 as a function of reductions in HIV-1 Tat-regulated firefly luciferase (Luc) reporter gene expression after a single round of infection with Env-pseudotyped viruses. This assay has become the main endpoint neutralization assay used for the assessment of pre-clinical and clinical trial samples by a growing number of laboratories worldwide. Here we present the results of the formal optimization and validation of the TZM-bl assay, performed in compliance with Good Clinical Laboratory Practice (GCLP) guidelines. The assay was evaluated for specificity, accuracy, precision, limits of detection and quantitation, linearity, range and robustness. The validated manual TZM-bl assay was also adapted, optimized and qualified to an automated 384-well format.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Anti-HIV/sangue , Infecções por HIV/diagnóstico , HIV-1/imunologia , Ensaios de Triagem em Larga Escala/normas , Testes de Neutralização/normas , Automação Laboratorial/normas , Biomarcadores/sangue , Fidelidade a Diretrizes/normas , Infecções por HIV/sangue , Infecções por HIV/imunologia , HIV-1/genética , Células HeLa , Humanos , Limite de Detecção , Variações Dependentes do Observador , Guias de Prática Clínica como Assunto/normas , Valor Preditivo dos Testes , Controle de Qualidade , Reprodutibilidade dos Testes , Fatores de Tempo , Transfecção
9.
PLoS One ; 7(1): e30963, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22303476

RESUMO

The Collaboration for AIDS Vaccine Discovery/Comprehensive Antibody-Vaccine Immune Monitoring Consortium (CAVD/CA-VIMC) assisted an international network of laboratories in transferring a validated assay used to judge HIV-1 vaccine immunogenicity in compliance with Good Clinical Laboratory Practice (GCLP) with the goal of adding quality to the conduct of endpoint assays for Human Immunodeficiency Virus I (HIV-1) vaccine human clinical trials. Eight Regional Laboratories in the international setting (Regional Laboratories), many located in regions where the HIV-1 epidemic is most prominent, were selected to implement the standardized, GCLP-compliant Neutralizing Antibody Assay for HIV-1 in TZM-bl Cells (TZM-bl NAb Assay). Each laboratory was required to undergo initial training and implementation of the immunologic assay on-site and then perform partial assay re-validation, competency testing, and undergo formal external audits for GCLP compliance. Furthermore, using a newly established external proficiency testing program for the TZM-bl NAb Assay has allowed the Regional Laboratories to assess the comparability of assay results at their site with the results of neutralizing antibody assays performed around the world. As a result, several of the CAVD/CA-VIMC Regional Laboratories are now in the process of conducting or planning to conduct the GCLP-compliant TZM-bl NAb Assay as an indicator of vaccine immunogenicity for ongoing human clinical trials.


Assuntos
Anticorpos Neutralizantes/imunologia , Ensaios Clínicos como Assunto/normas , Fidelidade a Diretrizes/normas , Anticorpos Anti-HIV/imunologia , HIV-1/imunologia , Internacionalidade , Testes de Neutralização/métodos , Transferência de Tecnologia , Vacinas contra a AIDS , DEAE-Dextrano , Células HeLa , Implementação de Plano de Saúde/normas , Humanos , Testes de Neutralização/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Titulometria
10.
J Immunol Methods ; 375(1-2): 57-67, 2012 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-21968254

RESUMO

Recent advances in assay technology have led to major improvements in how HIV-1 neutralizing antibodies are measured. A luciferase reporter gene assay performed in TZM-bl (JC53bl-13) cells has been optimized and validated. Because this assay has been adopted by multiple laboratories worldwide, an external proficiency testing program was developed to ensure data equivalency across laboratories performing this neutralizing antibody assay for HIV/AIDS vaccine clinical trials. The program was optimized by conducting three independent rounds of testing, with an increased level of stringency from the first to third round. Results from the participating domestic and international laboratories improved each round as factors that contributed to inter-assay variability were identified and minimized. Key contributors to increased agreement were experience among laboratories and standardization of reagents. A statistical qualification rule was developed using a simulation procedure based on the three optimization rounds of testing, where a laboratory qualifies if at least 25 of the 30 ID50 values lie within the acceptance ranges. This ensures no more than a 20% risk that a participating laboratory fails to qualify when it should, as defined by the simulation procedure. Five experienced reference laboratories were identified and tested a series of standardized reagents to derive the acceptance ranges for pass-fail criteria. This Standardized Proficiency Testing Program is the first available for the evaluation and documentation of assay equivalency for laboratories performing HIV-1 neutralizing antibody assays and may provide guidance for the development of future proficiency testing programs for other assay platforms.


Assuntos
Anticorpos Neutralizantes/análise , Anticorpos Anti-HIV/análise , HIV-1/imunologia , Ensaio de Proficiência Laboratorial/normas , Testes de Neutralização/normas , Vacinas contra a AIDS/imunologia , Anticorpos Neutralizantes/imunologia , Linhagem Celular Tumoral , Anticorpos Anti-HIV/imunologia , Infecções por HIV/imunologia , Infecções por HIV/virologia , Humanos , Controle de Qualidade , Padrões de Referência
11.
J Virol ; 83(15): 7397-410, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19458010

RESUMO

Receptors (FcgammaRs) for the constant region of immunoglobulin G (IgG) are an important link between humoral immunity and cellular immunity. To help define the role of FcgammaRs in determining the fate of human immunodeficiency virus type 1 (HIV-1) immune complexes, cDNAs for the four major human Fcgamma receptors (FcgammaRI, FcgammaRIIa, FcgammaRIIb, and FcgammaRIIIa) were stably expressed by lentiviral transduction in a cell line (TZM-bl) commonly used for standardized assessments of HIV-1 neutralization. Individual cell lines, each expressing a different FcgammaR, bound human IgG, as evidence that the physical properties of the receptors were preserved. In assays with a HIV-1 multisubtype panel, the neutralizing activities of two monoclonal antibodies (2F5 and 4E10) that target the membrane-proximal external region (MPER) of gp41 were potentiated by FcgammaRI and, to a lesser extent, by FcgammaRIIb. Moreover, the neutralizing activity of an HIV-1-positive plasma sample known to contain gp41 MPER-specific antibodies was potentiated by FcgammaRI. The neutralizing activities of monoclonal antibodies b12 and 2G12 and other HIV-1-positive plasma samples were rarely affected by any of the four FcgammaRs. Effects with gp41 MPER-specific antibodies were moderately stronger for IgG1 than for IgG3 and were ineffective for Fab. We conclude that FcgammaRI and FcgammaRIIb facilitate antibody-mediated neutralization of HIV-1 by a mechanism that is dependent on the Fc region, IgG subclass, and epitope specificity of antibody. The FcgammaR effects seen here suggests that the MPER of gp41 could have greater value for vaccines than previously recognized.


Assuntos
Anticorpos Anti-HIV/imunologia , Proteína gp41 do Envelope de HIV/imunologia , Infecções por HIV/imunologia , HIV-1/imunologia , Receptores de IgG/imunologia , Sequência de Aminoácidos , Linhagem Celular , Proteína gp41 do Envelope de HIV/química , Proteína gp41 do Envelope de HIV/genética , Infecções por HIV/genética , Infecções por HIV/virologia , HIV-1/química , HIV-1/genética , Humanos , Imunoglobulina G/imunologia , Dados de Sequência Molecular , Receptores de IgG/genética , Alinhamento de Sequência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...