Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 88(17): 8664-72, 2016 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-27500473

RESUMO

It is widely accepted that column technology is ahead of existing chromatographic instruments. The chromatographic output may not reflect the true picture of the peak profile inside the column. The instrumental optimization parameters become far more important when peaks elute in a few seconds. In this work, the low viscosity advantage of the supercritical/subcritical CO2 is coupled with the high efficiency of narrow particle size distribution silica. Using short efficient columns and high flow rates (up to 19 mL/min), separations on the order of a few seconds are demonstrated. In the domain of ultrafast supercritical fluid chromatography (SFC), unexpected results are seen which are absent in ultrafast liquid chromatography. These effects arise due to the compressible nature of the mobile phase and detector idiosyncrasies to eliminate back-pressure regulator noise. We demonstrate unusual connection tubing effects with 50, 75, 127, 254, and 500 µm tubings and show the complex relation of dead time, retention time, efficiency, and optimum velocity with the tubing diameter (via column outlet pressure). Fourier analysis at different back-pressure regulator (BPR) settings shows that some instruments have very specific noise frequencies originating from the BPR, and those specific frequencies vanish under certain conditions. The performance of embedded digital filters, namely, moving average, numerically simulated low pass RC, and Gaussian kernels, is compared. This work also demonstrates, using a simple derivative test, that some instruments employ interpolation techniques while sampling at "true" low frequencies to avoid picking up high frequency noise. Researchers engaged in ultrafast chromatography need to be aware of the instrumental nuances and optimization procedures for achieving ultrafast chiral or achiral separations in SFC mode.

2.
Bioorg Med Chem Lett ; 17(4): 1047-51, 2007 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-17127059
3.
Langmuir ; 21(24): 11119-27, 2005 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-16285780

RESUMO

Covalently networked films of nanoparticles can be assembled on various substrates from functionalized monolayer-protected clusters (MPCs) via ester coupling reactions. Exposure of a specifically modified substrate to alternating solutions of 11-mercaptoundecanoic acid exchanged and 11-mercaptoundecanol exchanged MPCs, in the presence of ester coupling reagents, 1,3-dicyclohexylcarbodiimide and 4-(dimethylamino)pyridine, results in the formation of a multilayer film with ester bridges between individual nanoparticles. These films can be grown in a controlled manner to various thicknesses and exhibit certain properties that are consistent with films having other types of interparticle connectivity, including chemical vapor response behavior and quantized double layer charging. Ester coupling of MPCs into assembled films is a straightforward and highly versatile approach that results in robust films that can endure harsher chemical environments than other types of films. The stability of these covalent films is assessed and compared to other more traditional MPC film assemblies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...