Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Sep Sci ; 43(9-10): 1623-1627, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31960568

RESUMO

A newly developed portable capillary liquid chromatograph was investigated for the separation of various pharmaceutical and illicit drug compounds. The system consists of two high-pressure syringe pumps capable of delivering capillary-scale flow rates at pressures up to 10 000 psi. Capillary liquid chromatography columns packed with sub-2 µm particles are housed in cartridges that can be inserted into the system and easily connected through high-pressure fluidic contact points by simply applying a specific, predetermined torque rather than using standard fittings and less precise sealing protocols. Several over-the-counter analgesic drug separations are demonstrated, along with a simple online measurement of tablet dissolution. Twenty illicit drug compounds were also separated across six targeted drug panels. The results described in this study demonstrate the capability of this compact liquid chromatography instrument to address several important drug-related applications while simplifying system operation, and greatly reducing solvent usage and waste generation essential for onsite analysis.


Assuntos
Drogas Ilícitas/análise , Cromatografia Líquida/instrumentação , Ciências Forenses/instrumentação
2.
Anal Chem ; 91(1): 792-796, 2019 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-30525480

RESUMO

This paper reports the first results of a robust, high-performance, stainless-steel microchip gas-chromatography (GC) column that is capable of analyzing complex real-world mixtures as well as operating at very high temperatures. Using a serpentine design, a 10 m column with an approximately semicircular cross-section with a 52 µm hydraulic diameter ( Dh) was produced in a 17 × 6.3 × 0.1 cm rectangular steel chip. The channels were produced using a multilayer-chemical-etch and diffusion-bonding process, and metal nuts were brazed onto the inlet and outlet ports allowing for column interfacing with ferrules and fused silica capillary tubing. After deactivating the metal surface, channels were statically coated with a ≈0.1 µm layer of 5% phenyl-1% vinyl-methylpolysiloxane (SE-54) stationary phase and cross-linked with dicumyl peroxide. By using n-tridecane ( n-C13) as a test analyte with a retention factor ( k) of 5, a total of 44 500 plates (≈4500 plates per meter) was obtained isothermally at 120 °C. The column was thermally stable to at least 350 °C, and rapid temperature programming (35 °C/min) was demonstrated for the boiling-point range from n-C5 to n-C44 (ASTM D2887 simulated-distillation standard). The column was also tested for separation of two complex mixtures: gasoline headspace and kerosene. These initial experiments demonstrate that the planar stainless-steel column with proper interfacing can be a viable alternative platform for portable, robust microchip GC that is capable of high-temperature operation for low-volatility-compound analysis.

3.
J Chromatogr A ; 1517: 134-141, 2017 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-28855092

RESUMO

Miniaturization of gas chromatography (GC) instrumentation is of interest because it addresses current and future issues relating to compactness, portability and field application. While incremental advancements continue to be reported in GC with columns fabricated in microchips (referred to in this paper as "microchip columns"), the current performance is far from acceptable. This lower performance compared to conventional GC is due to factors such as pooling of the stationary phase in corners of non-cylindrical channels, adsorption of sensitive compounds on incompletely deactivated surfaces, shorter column lengths and less than optimum interfacing to injector and detector. In this work, a GC system utilizing microchip columns was developed that solves the latter challenge, i.e., microchip interfacing to injector and detector. A microchip compression clamp was constructed to heat the microchip (i.e., primary heater), and seal the injector and detector fused silica interface tubing to the inlet and outlet ports of the microchip channels with minimum extra-column dead volume. This clamp allowed occasional operation up to 375°C and routine operation up to 300°C. The compression clamp was constructed of a low expansion alloy, Kovar™, to minimize leaking due to thermal expansion mismatch at the interface during repeated thermal cycling, and it was tested over several months for more than one hundred injections without forming leaks. A 5.9m long microcolumn with rectangular cross section of 158µm×80µm, which approximately matches a 100µm i.d. cylindrical fused silica column, was fabricated in a silicon wafer using deep reactive ion etching (DRIE) and high temperature fusion bonding; finally, the channel was coated statically with a 1% vinyl, 5% phenyl, 94% methylpolysiloxane stationary phase. High temperature separations of C10-C40 n-alkanes and a commercial diesel sample were demonstrated using the system under both temperature programmed GC (TPGC) and thermal gradient GC (TGGC) conditions. TGGC analysis of a complex essential oil sample was also demonstrated. Addition of a secondary heater and polyimide insulation proved to be helpful in achieving the desired elution temperature without having to raise the primary heater temperature above 300°C for high boiling point compounds.


Assuntos
Cromatografia Gasosa/instrumentação , Cromatografia Gasosa/métodos , Temperatura Alta , Silício/química , Alcanos/isolamento & purificação , Análise em Microsséries , Dióxido de Silício/química
4.
J Chromatogr A ; 1523: 242-247, 2017 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-28818326

RESUMO

The design of a miniaturized LED-based UV-absorption detector was significantly improved for on-column nanoflow LC. The detector measures approximately 27mm×24mm×10mm and weighs only 30g. Detection limits down to the nanomolar range and linearity across 3 orders of magnitude were obtained using sodium anthraquinone-2-sulfonate as a test analyte. Using two miniaturized detectors, a dual-detector system was assembled containing 255nm and 275nm LEDs with only 216nL volume between the detectors A 100µm slit was used for on-column detection with a 150µm i.d. packed capillary column. Chromatographic separation of a phenol mixture was demonstrated using the dual-detector system, with each detector producing a unique chromatogram. Less than 6% variation in the ratios of absorbances measured at the two wavelengths for specific analytes was obtained across 3 orders of magnitude concentration, which demonstrates the potential of using absorption ratio measurements for target analyte detection. The dual-detector system was used for simple, but accurate, mobile phase flow rate measurement at the exit of the column. With a flow rate range from 200 to 2000nL/min, less than 3% variation was observed.


Assuntos
Técnicas de Química Analítica/instrumentação , Cromatografia Líquida/instrumentação , Indicadores e Reagentes , Limite de Detecção , Espectrofotometria Ultravioleta
5.
Anal Chem ; 89(1): 807-812, 2017 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-28105847

RESUMO

A compact ultrahigh-pressure nanoflow liquid chromatograph (LC) was developed with the purpose in mind of creating a portable system that could be easily moved to various testing locations or placed in close proximity to other instruments for optimal coupling, such as with mass spectrometry (MS). The system utilized innovative nanoflow pumps integrated with a very low volume stop-flow injector and mixing tee. The system weighed only 5.9 kg (13 lbs) or 4.5 kg (10 lbs) without a controller and could hold up to 1100 bar (16000 psi) of pressure. The total volume pump capacity was 60 µL. In this study, the sample injection volume was determined by either a 60 nL internal sample groove machined in a high-pressure valve rotor or by a 1 µL external sample loop, although other sample grooves or loops could be selected. The gradient dwell volume was approximately 640 nL, which allowed significant reduction in sample analysis time. Gradient performance was evaluated by determining the gradient step accuracy. A low RSD (0.6%, n = 4) was obtained for day-to-day experiments. Linear gradient reproducibility was evaluated by separating a three-component polycyclic aromatic hydrocarbon mixture on a commercial 150 µm inner diameter capillary column packed with 1.7 µm particles. Good retention-time reproducibility (RSD < 0.17%) demonstrated that the pumping system could successfully generate ultrahigh pressures for use in capillary LC. The system was successfully coupled to an LTQ Orbitrap MS in a simple and efficient way; LC-MS of a trypsin-digested bovine serum albumin (BSA) sample provided narrow peaks, short dwell time, and good peptide coverage.


Assuntos
Nanotecnologia , Soroalbumina Bovina/análise , Animais , Bovinos , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas , Pressão , Espectrofotometria Ultravioleta
7.
J Chromatogr A ; 1421: 38-47, 2015 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-26592464

RESUMO

Over the last four decades, liquid chromatography (LC) has experienced an evolution to smaller columns and particles, new stationary phases and low flow rate instrumentation. However, the development of person-portable LC has not followed, mainly due to difficulties encountered in miniaturizing pumps and detectors, and in reducing solvent consumption. The recent introduction of small, non-splitting pumping systems and UV-absorption detectors for use with capillary columns has finally provided miniaturized instrumentation suitable for high-performance hand-portable LC. Fully integrated microfabricated LC still remains a significant challenge. Ion chromatography (IC) has been successfully miniaturized and applied for field analysis; however, applications are mostly limited to inorganic and small organic ions. This review covers advancements that make possible more rapid expansion of portable forms of LC and IC.


Assuntos
Cromatografia Líquida/instrumentação , Cromatografia por Troca Iônica/instrumentação , Cromatografia por Troca Iônica/métodos , Cromatografia Líquida/métodos , Miniaturização
8.
J Fluoresc ; 23(5): 881-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23576004

RESUMO

Understanding molecular interactions is critical to understanding most biological mechanisms of cells and organisms. In the case of small molecule-protein interactions, many molecules have significant biological activity through interactions with unknown target proteins and by unknown modes of action. Identifying these target proteins is of significant importance and ongoing work in our laboratories is developing a technique termed Dynamic Isoelectric Anisotropy Binding Ligand Assay (DIABLA) to meet this need. Work presented in this manuscript aims to characterize the fundamental parameters affecting the use of fluorescence anisotropy to detect target proteins for a given ligand. Emphasis is placed on evaluating the use of fluorescence anisotropy as a detection mechanism, including optimization factors that affect the protein detection limit. Effects of ligand concentration, pH, and nonspecific binding are also examined.


Assuntos
Ciclo-Oxigenase 1/análise , Estreptavidina/análise , Biotina/química , Ciclo-Oxigenase 1/metabolismo , Polarização de Fluorescência , Ibuprofeno/química , Cinética , Ligantes , Estrutura Molecular , Naproxeno/química , Progesterona/química , Termodinâmica
9.
Drug Des Devel Ther ; 5: 427-33, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22087062

RESUMO

BACKGROUND: This study assessed the relative bioavailability of two formulations of ibuprofen. The first formulation was Doloraz(®), produced by Al-Razi Pharmaceutical Company, Amman, Jordan. The second forumulation was Brufen(®), manufactured by Boots Company, Nottingham, UK. METHODS AND RESULTS: A prestudy validation of ibuprofen demonstrated long-term stability, freeze-thaw stability, precision, and accuracy. Twenty-four healthy volunteers were enrolled in this study. After overnight fasting, the two formulations (test and reference) of ibuprofen (100 mg ibuprofen/5 mL suspension) were administered as a single dose on two treatment days separated by a one-week washout period. After dosing, serial blood samples were drawn for a period of 14 hours. Serum harvested from the blood samples was analyzed for the presence of ibuprofen by high-pressure liquid chromatography with ultraviolet detection. Pharmacokinetic parameters were determined from serum concentrations for both formulations. The 90% confidence intervals of the ln-transformed test/reference treatment ratios for peak plasma concentration and area under the concentration-time curve (AUC) parameters were found to be within the predetermined acceptable interval of 80%-125% set by the US Food and Drug Administration. CONCLUSION: Analysis of variance for peak plasma concentrations and AUC parameters showed no significant difference between the two formulations and, therefore, Doloraz was considered bioequivalent to Brufen.


Assuntos
Ibuprofeno/farmacocinética , Adulto , Área Sob a Curva , Calibragem , Estudos Cross-Over , Estabilidade de Medicamentos , Humanos , Ibuprofeno/administração & dosagem , Ibuprofeno/efeitos adversos , Ibuprofeno/análise , Ibuprofeno/sangue , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Equivalência Terapêutica , Adulto Jovem
10.
J Proteome Res ; 7(10): 4594-7, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18707155

RESUMO

Dynamic isoelectric/anisotropy binding ligand assay (DIABLA) is a new method to identify proteins in a complex sample that bind to a molecule of interest. This is accomplished by first using capillary isoelectric focusing (cIEF) to separate the proteins in a capillary based on their isoelectric point. This separation is performed while the compound being tested is present in the separation buffer. When the proteins are focused, the entire capillary is scanned to identify regions of nonzero anisotropy, which are locations where the test compound is interacting with a focused protein band. DIABLA was demonstrated by observing the binding of fluorescein-tagged progesterone to an MCF-7 breast cancer cell lysate. The proteins were tagged with rhodamine to permit their observation and then focused in the presence of the tagged progesterone. Anisotropy measurements show that progesterone binds to six different proteins bands in the sample.


Assuntos
Focalização Isoelétrica/métodos , Proteínas/análise , Animais , Anisotropia , Linhagem Celular Tumoral , Humanos , Focalização Isoelétrica/instrumentação , Progesterona/química , Progesterona/metabolismo
11.
Anal Chem ; 78(18): 6511-8, 2006 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-16970328

RESUMO

Dynamic isoelectric focusing is a new technique that is related to capillary isoelectric focusing but uses additional high-voltage power supplies to provide control over the shape of the electric field within the capillary. Manipulation of the electric field changes the pH gradient, enabling both the location and width of the focused protein bands to be controlled. The proteins can be migrated to a designated sampling point while remaining focused, where they can be collected for further analysis. This ability to collect and isolate the protein bands while maintaining a high peak capacity demonstrates that dynamic isoelectric focusing has great potential as a first dimension in a multidimensional separation system. Dynamic isoelectric focusing can achieve a peak capacity of over 1000, as shown by both mass spectrometry analysis and direct imaging.


Assuntos
Focalização Isoelétrica/métodos , Proteômica/métodos , Animais , Cavalos , Focalização Isoelétrica/instrumentação , Mioglobina/química
12.
J Chromatogr A ; 1094(1-2): 148-57, 2005 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-16257301

RESUMO

A theoretical model of the contactless conductivity detector (CCD) has been developed consisting of a network of resistors and capacitors. The output of the model is compared to experimental results and to the output of a simpler model. Experimentally, a lock-in amplifier is added to the detection scheme of the contactless conductivity detector to provide a more sensitive method of signal isolation. The detector is assembled on a printed circuit board with the electrodes in a co-axial configuration. The electrodes are chosen to allow for use with fused silica capillaries in capillary electrophoresis. The use of a lock-in amplifier in place of a previous rectification/filtering circuit allows for an approximate 10-fold improvement in S/N. The detector shows a linear response to changes in excitation voltage and to changes in analyte concentration. Mass limits of detection of 60, 63, and 50 fg are determined for the inorganic cations potassium, sodium, and lithium, respectively (for a signal three times the level of the rms noise).


Assuntos
Eletroquímica/instrumentação , Condutividade Elétrica , Eletroforese Capilar
13.
Rapid Commun Mass Spectrom ; 19(16): 2337-42, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16041824

RESUMO

A method for the extraction and analysis of tocopherols from serum using coordinated ion spray (CIS) mass spectrometry was developed and tested. The tocopherols were extracted from serum and analyzed by direct infusion into the mass spectrometer, bypassing the need for a liquid chromatography step. CIS is a method for improving the ionization efficiency of non-polar compounds by adding metal ions to the electrospray solvent. The non-polar analytes appear as metal adducts in the resulting mass spectrum. Silver was used as the metal ion for the CIS, causing analyte masses to be increased by 107 and 109 Da from the two main silver isotopes. Vitamin E succinate was added to the samples before extraction and was used as an internal standard to compensate for any variations in the extraction efficiency or mass spectrometric response. alpha-Tocopherol and an ether-linked analogue known as alpha-TEA were analyzed in concentrations from 1.25-40 microg/mL (1.9-60 pg consumed). The response curve was constructed by comparing the response of the analytes to the internal standard and gave linear results with r2 values greater than 0.98. This new method was shown to be sensitive, reproducible, fast and required very small amounts of analyte.


Assuntos
Vitamina E/análogos & derivados , alfa-Tocoferol/química , Estrutura Molecular , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray , Tocoferóis , Vitamina E/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...