Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38722777

RESUMO

OBJECTIVE: To perform image quality comparison between deep learning-based multiband diffusion-weighted sequence (DL-mb-DWI), accelerated multiband diffusion-weighted sequence (accelerated mb-DWI), and conventional multiband diffusion-weighted sequence (conventional mb-DWI) in patients undergoing clinical liver magnetic resonance imaging (MRI). METHODS: Fifty consecutive patients who underwent clinical MRI of the liver at a 1.5-T scanner, between September 1, 2021, and January 31, 2022, were included in this study. Three radiologists independently reviewed images using a 5-point Likert scale for artifacts and image quality factors, in addition to assessing the presence of liver lesions and lesion conspicuity. RESULTS: DL-mb-DWI acquisition time was 65.0 ± 2.4 seconds, significantly (P < 0.001) shorter than conventional mb-DWI (147.5 ± 19.2 seconds) and accelerated mb-DWI (94.3 ± 1.8 seconds). DL-mb-DWI received significantly higher scores than conventional mb-DWI for conspicuity of the left lobe (P < 0.001), sharpness of intrahepatic vessel margin (P < 0.001), sharpness of the pancreatic contour (P < 0.001), in-plane motion artifact (P = 0.002), and overall image quality (P = 0.005) by reader 2. DL-mb-DWI received significantly higher scores for conspicuity of the left lobe (P = 0.006), sharpness of the pancreatic contour (P = 0.020), and in-plane motion artifact (P = 0.042) by reader 3. DL-mb-DWI received significantly higher scores for strength of fat suppression (P = 0.004) and sharpness of the pancreatic contour (P = 0.038) by reader 1. The remaining quality parameters did not reach statistical significance for reader 1. CONCLUSIONS: Novel diffusion-weighted MRI sequence with deep learning-based image reconstruction demonstrated significantly decreased acquisition times compared with conventional and accelerated mb-DWI sequences, while maintaining or improving image quality for routine abdominal MRI. DL-mb-DWI offers a potential alternative to conventional mb-DWI in routine clinical liver MRI.

2.
Sci Data ; 11(1): 404, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643291

RESUMO

Magnetic resonance imaging (MRI) has experienced remarkable advancements in the integration of artificial intelligence (AI) for image acquisition and reconstruction. The availability of raw k-space data is crucial for training AI models in such tasks, but public MRI datasets are mostly restricted to DICOM images only. To address this limitation, the fastMRI initiative released brain and knee k-space datasets, which have since seen vigorous use. In May 2023, fastMRI was expanded to include biparametric (T2- and diffusion-weighted) prostate MRI data from a clinical population. Biparametric MRI plays a vital role in the diagnosis and management of prostate cancer. Advances in imaging methods, such as reconstructing under-sampled data from accelerated acquisitions, can improve cost-effectiveness and accessibility of prostate MRI. Raw k-space data, reconstructed images and slice, volume and exam level annotations for likelihood of prostate cancer are provided in this dataset for 47468 slices corresponding to 1560 volumes from 312 patients. This dataset facilitates AI and algorithm development for prostate image reconstruction, with the ultimate goal of enhancing prostate cancer diagnosis.


Assuntos
Imageamento por Ressonância Magnética , Próstata , Neoplasias da Próstata , Humanos , Masculino , Inteligência Artificial , Aprendizado de Máquina , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
3.
BMJ Open ; 13(11): e075840, 2023 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-37949625

RESUMO

OBJECTIVE: Poor medication adherence remains highly prevalent and adversely affects health outcomes. Patients frequently describe properties of the pills themselves, like size and shape, as barriers, but this has not been evaluated objectively. We sought to determine the extent to which oral medication properties thought to be influential translate into lower objectively-measured adherence. DESIGN: Retrospective cohort study. SETTING: US nationwide commercial claims database, 2016-2019. PARTICIPANTS: Among patients initiating first-line hypertension, diabetes or hyperlipidaemia treatment based on clinical guidelines, we measured pill size, shape, colour and flavouring, number of pills/day and fixed-dose combination status as properties. OUTCOME MEASURES: Outcomes included discontinuation after the first fill (ie, never filling again over a minimum of 1-year follow-up) and long-term non-adherence (1-year proportion of days covered <0.80). We estimated associations between each property and outcomes, by therapeutic class (eg, statins), with multivariable logistic regression. RESULTS: Across 604 323 patients, 14.6% discontinued after filling once (ie, were non-persistent), and 54.0% were non-adherent over 1-year follow-up. Large pill size was associated with non-adherence, except for thiazides (eg, metformin adjusted OR (aOR): 1.12, 95% CI: 1.06 to 1.18). Greater pill burden was associated with a higher risk of non-adherence across all classes (eg, metformin aOR: 1.58, 95% CI: 1.53 to 1.64 for two pills/day). Taking less than one pill/day was also associated with higher risk of non-adherence and non-persistence (eg, non-persistence statin aOR: 1.29, 95% CI: 1.20 to 1.38). Pill shape, colour, flavouring and combination status were associated with mixed effects across classes. CONCLUSIONS: Pill burden and pill size are key properties affecting adherence for almost all classes; others, like size and combination, could modestly affect medication adherence. Clinical interventions could screen patients for potential intolerance to medication and potentially implement more convenient dosing schedules.


Assuntos
Inibidores de Hidroximetilglutaril-CoA Redutases , Hipertensão , Metformina , Humanos , Estados Unidos , Estudos Retrospectivos , Hipertensão/tratamento farmacológico , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Adesão à Medicação , Metformina/uso terapêutico
4.
ArXiv ; 2023 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-37131871

RESUMO

The fastMRI brain and knee dataset has enabled significant advances in exploring reconstruction methods for improving speed and image quality for Magnetic Resonance Imaging (MRI) via novel, clinically relevant reconstruction approaches. In this study, we describe the April 2023 expansion of the fastMRI dataset to include biparametric prostate MRI data acquired on a clinical population. The dataset consists of raw k-space and reconstructed images for T2-weighted and diffusion-weighted sequences along with slice-level labels that indicate the presence and grade of prostate cancer. As has been the case with fastMRI, increasing accessibility to raw prostate MRI data will further facilitate research in MR image reconstruction and evaluation with the larger goal of improving the utility of MRI for prostate cancer detection and evaluation. The dataset is available at https://fastmri.med.nyu.edu.

6.
Invest Radiol ; 58(10): 720-729, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37222526

RESUMO

INTRODUCTION: Prostate cancer diffusion weighted imaging (DWI) MRI is typically performed at high-field strength (3.0 T) in order to overcome low signal-to-noise ratio (SNR). In this study, we demonstrate the feasibility of prostate DWI at low field enabled by random matrix theory (RMT)-based denoising, relying on the MP-PCA algorithm applied during image reconstruction from multiple coils. METHODS: Twenty-one volunteers and 2 prostate cancer patients were imaged with a 6-channel pelvic surface array coil and an 18-channel spine array on a prototype 0.55 T system created by ramping down a commercial magnetic resonance imaging system (1.5 T MAGNETOM Aera Siemens Healthcare) with 45 mT/m gradients and 200 T/m/s slew rate. Diffusion-weighted images were acquired with 4 non-collinear directions, for which b = 50 s/mm 2 was used with 8 averages and b = 1000 s/mm 2 with 40 averages; 2 extra b = 50 s/mm 2 were used as part of the dynamic field correction. Standard and RMT-based reconstructions were applied on DWI over different ranges of averages. Accuracy/precision was evaluated using the apparent diffusion coefficient (ADC), and image quality was evaluated over 5 separate reconstructions by 3 radiologists with a 5-point Likert scale. For the 2 patients, we compare image quality and lesion visibility of the RMT reconstruction versus the standard one on 0.55 T and on clinical 3.0 T. RESULTS: The RMT-based reconstruction in this study reduces the noise floor by a factor of 5.8, thereby alleviating the bias on prostate ADC. Moreover, the precision of the ADC in prostate tissue after RMT increases over a range of 30%-130%, with the increase in both signal-to-noise ratio and precision being more prominent for a low number of averages. Raters found that the images were consistently of moderate to good overall quality (3-4 on the Likert scale). Moreover, they determined that b = 1000 s/mm 2 images from a 1:55-minute scan with the RMT-based reconstruction were on par with the corresponding images from a 14:20-minute scan with standard reconstruction. Prostate cancer was visible on ADC and calculated b = 1500 images even with the abbreviated 1:55-minute scan reconstructed with RMT. CONCLUSIONS: Prostate imaging using DWI is feasible at low field and can be performed more rapidly with noninferior image quality compared with standard reconstruction.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Estudos de Viabilidade , Neoplasias da Próstata/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Razão Sinal-Ruído , Reprodutibilidade dos Testes
7.
Cancer Imaging ; 23(1): 6, 2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36647150

RESUMO

BACKGROUND: Deep-learning-based computer-aided diagnosis (DL-CAD) systems using MRI for prostate cancer (PCa) detection have demonstrated good performance. Nevertheless, DL-CAD systems are vulnerable to high heterogeneities in DWI, which can interfere with DL-CAD assessments and impair performance. This study aims to compare PCa detection of DL-CAD between zoomed-field-of-view echo-planar DWI (z-DWI) and full-field-of-view DWI (f-DWI) and find the risk factors affecting DL-CAD diagnostic efficiency. METHODS: This retrospective study enrolled 354 consecutive participants who underwent MRI including T2WI, f-DWI, and z-DWI because of clinically suspected PCa. A DL-CAD was used to compare the performance of f-DWI and z-DWI both on a patient level and lesion level. We used the area under the curve (AUC) of receiver operating characteristics analysis and alternative free-response receiver operating characteristics analysis to compare the performances of DL-CAD using f- DWI and z-DWI. The risk factors affecting the DL-CAD were analyzed using logistic regression analyses. P values less than 0.05 were considered statistically significant. RESULTS: DL-CAD with z-DWI had a significantly better overall accuracy than that with f-DWI both on patient level and lesion level (AUCpatient: 0.89 vs. 0.86; AUClesion: 0.86 vs. 0.76; P < .001). The contrast-to-noise ratio (CNR) of lesions in DWI was an independent risk factor of false positives (odds ratio [OR] = 1.12; P < .001). Rectal susceptibility artifacts, lesion diameter, and apparent diffusion coefficients (ADC) were independent risk factors of both false positives (ORrectal susceptibility artifact = 5.46; ORdiameter, = 1.12; ORADC = 0.998; all P < .001) and false negatives (ORrectal susceptibility artifact = 3.31; ORdiameter = 0.82; ORADC = 1.007; all P ≤ .03) of DL-CAD. CONCLUSIONS: Z-DWI has potential to improve the detection performance of a prostate MRI based DL-CAD. TRIAL REGISTRATION: ChiCTR, NO. ChiCTR2100041834 . Registered 7 January 2021.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Masculino , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos
8.
J Magn Reson Imaging ; 58(4): 1055-1064, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36651358

RESUMO

BACKGROUND: Demand for prostate MRI is increasing, but scan times remain long even in abbreviated biparametric MRIs (bpMRI). Deep learning can be leveraged to accelerate T2-weighted imaging (T2WI). PURPOSE: To compare conventional bpMRIs (CL-bpMRI) with bpMRIs including a deep learning-accelerated T2WI (DL-bpMRI) in diagnosing prostate cancer. STUDY TYPE: Retrospective. POPULATION: Eighty consecutive men, mean age 66 years (47-84) with suspected prostate cancer or prostate cancer on active surveillance who had a prostate MRI from December 28, 2020 to April 28, 2021 were included. Follow-up included prostate biopsy or stability of prostate-specific antigen (PSA) for 1 year. FIELD STRENGTH AND SEQUENCES: A 3 T MRI. Conventional axial and coronal T2 turbo spin echo (CL-T2), 3-fold deep learning-accelerated axial and coronal T2-weighted sequence (DL-T2), diffusion weighted imaging (DWI) with b = 50 sec/mm2 , 1000 sec/mm2 , calculated b = 1500 sec/mm2 . ASSESSMENT: CL-bpMRI and DL-bpMRI including the same conventional diffusion-weighted imaging (DWI) were presented to three radiologists (blinded to acquisition method) and to a deep learning computer-assisted detection algorithm (DL-CAD). The readers evaluated image quality using a 4-point Likert scale (1 = nondiagnostic, 4 = excellent) and graded lesions using Prostate Imaging Reporting and Data System (PI-RADS) v2.1. DL-CAD identified and assigned lesions of PI-RADS 3 or greater. STATISTICAL TESTS: Quality metrics were compared using Wilcoxon signed rank test, and area under the receiver operating characteristic curve (AUC) were compared using Delong's test. SIGNIFICANCE: P = 0.05. RESULTS: Eighty men were included (age: 66 ± 9 years; 17/80 clinically significant prostate cancer). Overall image quality results by the three readers (CL-T2, DL-T2) are reader 1: 3.72 ± 0.53, 3.89 ± 0.39 (P = 0.99); reader 2: 3.33 ± 0.82, 3.31 ± 0.74 (P = 0.49); reader 3: 3.67 ± 0.63, 3.51 ± 0.62. In the patient-based analysis, the reader results of AUC are (CL-bpMRI, DL-bpMRI): reader 1: 0.77, 0.78 (P = 0.98), reader 2: 0.65, 0.66 (P = 0.99), reader 3: 0.57, 0.60 (P = 0.52). Diagnostic statistics from DL-CAD (CL-bpMRI, DL-bpMRI) are sensitivity (0.71, 0.71, P = 1.00), specificity (0.59, 0.44, P = 0.05), positive predictive value (0.23, 0.24, P = 0.25), negative predictive value (0.88, 0.88, P = 0.48). CONCLUSION: Deep learning-accelerated T2-weighted imaging may potentially be used to decrease acquisition time for bpMRI. EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: Stage 2.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Masculino , Humanos , Idoso , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos
9.
Magn Reson Imaging Clin N Am ; 31(1): 121-135, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36368857

RESUMO

Endometriosis is the presence of ectopic endometrial glands outside of the uterus. MR imaging is particularly useful for characterizing deep infiltrating endometriosis but can also be useful in characterizing endometriomas and hematosalpinges, characterizing broad ligament deposits, assessing for endometriosis-associated malignancy, and differentiating malignancy from decidualized endometriomas. Masses and cysts with hemorrhagic or proteinaceous contents can sometimes be difficult to distinguish from endometriomas. Imaging protocols should include pre-contrast T1-weighted imaging with fat saturation, T2-weighted imaging without fat saturation, opposed- and in-phase or Dixon imaging, administration of contrast media, and subtraction imaging.


Assuntos
Endometriose , Feminino , Humanos , Endometriose/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Diagnóstico Diferencial , Endométrio/patologia , Meios de Contraste
10.
Magn Reson Imaging ; 97: 56-67, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36577458

RESUMO

This work aimed to develop a modified stack-of-stars golden-angle radial sampling scheme with variable-density acceleration along the slice (kz) dimension (referred to as VD-stack-of-stars) and to test this new sampling trajectory with multi-coil compressed sensing reconstruction for rapid motion-robust 3D liver MRI. VD-stack-of-stars sampling implements additional variable-density undersampling along the kz dimension, so that slice resolution (or volumetric coverage) can be increased without prolonging scan time. The new sampling trajectory (with increased slice resolution) was compared with standard stack-of-stars sampling with fully sampled kz (with standard slice resolution) in both non-contrast-enhanced free-breathing liver MRI and dynamic contrast-enhanced MRI (DCE-MRI) of the liver in volunteers. For both sampling trajectories, respiratory motion was extracted from the acquired radial data, and images were reconstructed using motion-compensated (respiratory-resolved or respiratory-weighted) dynamic radial compressed sensing reconstruction techniques. Qualitative image quality assessment (visual assessment by experienced radiologists) and quantitative analysis (as a metric of image sharpness) were performed to compare images acquired using the new and standard stack-of-stars sampling trajectories. Compared to standard stack-of-stars sampling, both non-contrast-enhanced and DCE liver MR images acquired with VD-stack-of-stars sampling presented improved overall image quality, sharper liver edges and increased hepatic vessel clarity in all image planes. The results have suggested that the proposed VD-stack-of-stars sampling scheme can achieve improved performance (increased slice resolution or volumetric coverage with better image quality) over standard stack-of-stars sampling in free-breathing DCE-MRI without increasing scan time. The reformatted coronal and sagittal images with better slice resolution may provide added clinical value.


Assuntos
Aumento da Imagem , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Aumento da Imagem/métodos , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Respiração , Artefatos
12.
Eur Radiol ; 33(1): 64-76, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35900376

RESUMO

OBJECTIVES: To evaluate the effect of a deep learning-based computer-aided diagnosis (DL-CAD) system on experienced and less-experienced radiologists in reading prostate mpMRI. METHODS: In this retrospective, multi-reader multi-case study, a consecutive set of 184 patients examined between 01/2018 and 08/2019 were enrolled. Ground truth was combined targeted and 12-core systematic transrectal ultrasound-guided biopsy. Four radiologists, two experienced and two less-experienced, evaluated each case twice, once without (DL-CAD-) and once assisted by DL-CAD (DL-CAD+). ROC analysis, sensitivities, specificities, PPV and NPV were calculated to compare the diagnostic accuracy for the diagnosis of prostate cancer (PCa) between the two groups (DL-CAD- vs. DL-CAD+). Spearman's correlation coefficients were evaluated to assess the relationship between PI-RADS category and Gleason score (GS). Also, the median reading times were compared for the two reading groups. RESULTS: In total, 172 patients were included in the final analysis. With DL-CAD assistance, the overall AUC of the less-experienced radiologists increased significantly from 0.66 to 0.80 (p = 0.001; cutoff ISUP GG ≥ 1) and from 0.68 to 0.80 (p = 0.002; cutoff ISUP GG ≥ 2). Experienced radiologists showed an AUC increase from 0.81 to 0.86 (p = 0.146; cutoff ISUP GG ≥ 1) and from 0.81 to 0.84 (p = 0.433; cutoff ISUP GG ≥ 2). Furthermore, the correlation between PI-RADS category and GS improved significantly in the DL-CAD + group (0.45 vs. 0.57; p = 0.03), while the median reading time was reduced from 157 to 150 s (p = 0.023). CONCLUSIONS: DL-CAD assistance increased the mean detection performance, with the most significant benefit for the less-experienced radiologist; with the help of DL-CAD less-experienced radiologists reached performances comparable to that of experienced radiologists. KEY POINTS: • DL-CAD used as a concurrent reading aid helps radiologists to distinguish between benign and cancerous lesions in prostate MRI. • With the help of DL-CAD, less-experienced radiologists may achieve detection performances comparable to that of experienced radiologists. • DL-CAD assistance increases the correlation between PI-RADS category and cancer grade.


Assuntos
Aprendizado Profundo , Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Neoplasias da Próstata/patologia , Gradação de Tumores , Biópsia Guiada por Imagem , Radiologistas , Computadores
13.
J Am Psychiatr Nurses Assoc ; 29(2): 103-111, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34109871

RESUMO

BACKGROUND: Pro re nata (PRN) antipsychotics and benzodiazepines are routinely used for the rapid stabilization of acutely agitated patients. Despite the popular use of PRN medications in mental health units, primary literature supporting efficacy and safety is poor, and there is no single universally accepted practice guideline. PRN psychotropic medications have the potential to cause adverse effects when used inappropriately. AIMS: Our objective was to characterize the prescribing, administration, and documentation practices of PRN psychotropic medications in a psychiatric intensive care unit. METHODS: We conducted a retrospective chart review of patients admitted to a 12-bed psychiatric intensive care unit between June and September 2018. All PRN antipsychotic and benzodiazepine orders, administrations, documentation practices, and attempted nonpharmacological strategies were assessed for each order and patient. Descriptive statistics were used to analyze data. RESULTS: Thirty-two patients with a total of 123 physicians' orders and 1,179 PRN administrations of antipsychotics and benzodiazepines were reviewed. Of the total administrations, 720 (61%) were combinations with at least two psychotropic agents. Forty-one (33%) physicians' orders had a prescribed indication, and 559 (47%) administrations had an attempted nonpharmacological method prior to PRN administration. Eight patients (25%) had antipsychotic PRN orders, which exceeded the total daily maximum dose. Three adverse drug effects were attributed to PRN administration. CONCLUSIONS: Areas of improvement that we identified included documentation practices of effectiveness of administered PRNs, prescriptions to include clear indications and dosage within the 24-hour maximum limits, and documentation of nonpharmacological methods utilized.


Assuntos
Antipsicóticos , Transtornos Mentais , Humanos , Antipsicóticos/uso terapêutico , Transtornos Mentais/tratamento farmacológico , Estudos Retrospectivos , Canadá , Psicotrópicos/uso terapêutico , Benzodiazepinas/uso terapêutico
14.
Arthritis Care Res (Hoboken) ; 75(6): 1300-1310, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36039962

RESUMO

OBJECTIVE: Despite increasing overall health care spending over the past several decades, little is known about long-term patterns of spending among US patients with gout. Current approaches to assessing spending typically focus on composite measures or patients agnostic to disease state; in contrast, examining spending using longitudinal measures may better discriminate patients and target interventions to those in need. We used a data-driven approach to classify and predict spending patterns in patients with gout. METHODS: Using insurance claims data from 2017-2019, we used group-based trajectory modeling to classify patients ages 40 years or older diagnosed with gout and treated with urate-lowering therapy (ULT) by their total health care spending over 2 years. We assessed the ability to predict membership in each spending group using logistic and generalized boosted regression with split-sample validation. Models were estimated using different sets of predictors and evaluated using C statistics. RESULTS: In 57,980 patients, the mean ± SD age was 71.0 ± 10.5 years, and 17,194 patients (29.7%) were female. The best-fitting model included the following groups: minimal spending (13.2%), moderate spending (37.4%), and high spending (49.4%). The ability to predict groups was high overall (e.g., boosted C statistics with all predictors: minimal spending [0.89], moderate spending [0.78], and high spending [0.90]). Although average adherence was relatively high in the population, for the high-spending group, the most influential predictors were greater gout medication adherence and diabetes melllitus diagnosis. CONCLUSION: We identified distinct long-term health care spending patterns in patients with gout using ULT with high accuracy. Several clinical predictors could be key areas for intervention, such as gout medication use or diabetes melllitus.


Assuntos
Gota , Ácido Úrico , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Supressores da Gota/uso terapêutico , Gastos em Saúde , Gota/diagnóstico , Gota/tratamento farmacológico , Adesão à Medicação
15.
Abdom Radiol (NY) ; 48(1): 282-290, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36171342

RESUMO

PURPOSE: Fat-suppressed T2-weighted imaging (T2-FS) requires a long scan time and can be wrought with motion artifacts, urging the development of a shorter and more motion robust sequence. We compare the image quality of a single-shot T2-weighted MRI prototype with deep-learning-based image reconstruction (DL HASTE-FS) with a standard T2-FS sequence for 3 T liver MRI. METHODS: 41 consecutive patients with 3 T abdominal MRI examinations including standard T2-FS and DL HASTE-FS, between 5/6/2020 and 11/23/2020, comprised the study cohort. Three radiologists independently reviewed images using a 5-point Likert scale for artifact and image quality measures, while also assessing for liver lesions. RESULTS: DL HASTE-FS acquisition time was 54.93 ± 16.69, significantly (p < .001) shorter than standard T2-FS (114.00 ± 32.98 s). DL HASTE-FS received significantly higher scores for sharpness of liver margin (4.3 vs 3.3; p < .001), hepatic vessel margin (4.2 vs 3.3; p < .001), pancreatic duct margin (4.0 vs 1.9; p < .001); in-plane (4.0 vs 3.2; p < .001) and through-plane (3.9 vs 3.4; p < .001) motion artifacts; other ghosting artifacts (4.3 vs 2.9; p < .001); and overall image quality (4.0 vs 2.9; p < .001), in addition to receiving a higher score for homogeneity of fat suppression (3.7 vs 3.4; p = .04) and liver-fat contrast (p = .03). For liver lesions, DL HASTE-FS received significantly higher scores for sharpness of lesion margin (4.4 vs 3.7; p = .03). CONCLUSION: Novel single-shot T2-weighted MRI with deep-learning-based image reconstruction demonstrated superior image quality compared with the standard T2-FS sequence for 3 T liver MRI, while being acquired in less than half the time.


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Humanos , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador , Artefatos
16.
World J Urol ; 40(11): 2765-2770, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36197506

RESUMO

PURPOSE: The objective of the study was to determine whether Axumin (18F-Fluciclovine) PET/MRI informs the decision to perform an early repeat biopsy of PI-RADS 4/5 region of interest (ROI) exhibiting no clinically significant prostate cancer (csPCa) on initial biopsy. METHODS: This prospective study enrolled men with at least one PI-RADS 4/5 ROI on multi-parametric MRI and no csPCa on prior biopsy defined as Gleason grade group (GGG) > 1. All men underwent an Axumin PET/MRI and only-persistent PI-RADS > 2 ROI were advised to undergo a repeat biopsy. A PET cancer suspicion score (PETCSS) was internally developed to stratify PET avid lesions according to their suspicion of harboring csPCa. The sensitivity, specificity, positive (PPV) and negative predictive value (NPV) of the PETCSS for predicting csPCa were assessed. Relative risk was calculated to analyze the association of baseline variables with csPCa on repeat biopsy. RESULTS: Thirty-eight ROI on 36 enrolled men were analyzed. Fourteen (36.8%) were downgraded to PI-RADS 1/2 and were not subjected to repeat biopsy. Thirteen (92.9%) of these downgraded scans also exhibited low-risk PETCSS. Overall, 18/22 (81.2%) subjects underwent a repeat per protocol biopsy. Of the 20 ROI subjected to repeat biopsy, eight (40%) were found to harbour csPCa. The sensitivity, specificity, PPV and NPV of the PETCSS were 50, 50, 40, and 60%, respectively. No predictor of csPCa was found in the risk analysis. CONCLUSION: Our pilot study showed that both MRI and PET sequences have limited performance for identifying those persistently suspicious PI-RADS 4/5 ROI that are found to harbor csPCa on repeat biopsy.


Assuntos
Neoplasias da Próstata , Masculino , Humanos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Projetos Piloto , Biópsia , Tomografia por Emissão de Pósitrons , Biópsia Guiada por Imagem/métodos , Estudos Retrospectivos
17.
Radiat Oncol ; 17(1): 66, 2022 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-35366926

RESUMO

BACKGROUND: The use of treatment planning prostate MRI for Stereotactic Body Radiation Therapy (SBRT) is largely a standard, yet not all patients can receive MRI for a variety of clinical reasons. Thus, we aim to investigate the safety of patients who received CT alone based SBRT planning for the definitive treatment of localized prostate cancer. METHODS: Our study analyzed 3410 patients with localized prostate cancer who were treated with SBRT at a single academic institution between 2006 and 2020. Acute and late toxicity was evaluated using the Common Terminology Criteria for Adverse Events version 5.0. Expanded Prostate Cancer Index Composite (EPIC) questionnaires evaluated QOL and PSA nadir was evaluated to detect biochemical failures. RESULTS: A total of 162 patients (4.75%) received CT alone for treatment planning. The CT alone group was older relative to the MRI group (69.9 vs 67.2, p < 0.001) and had higher risk and grade disease (p < 0.001). Additionally, the CT group exhibited a trend in larger CTVs (82.56 cc vs 76.90 cc; p = 0.055), lower total radiation doses (p = 0.048), and more frequent pelvic nodal radiation versus the MRI group (p < 0.001). There were only two reported cases of Grade 3 + toxicity within the CT alone group. Quality of life data within the CT alone group revealed declines in urinary and bowel scores at one month with return to baseline at subsequent follow up. Early biochemical failure data at median time of 2.3 years revealed five failures by Phoenix definition. CONCLUSIONS: While clinical differences existed between the MRI and CT alone group, we observed tolerable toxicity profiles in the CT alone cohort, which was further supported by EPIC questionnaire data. The overall clinical outcomes appear comparable in patients unable to receive MRI for their SBRT treatment plan with early clinical follow up.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Humanos , Imageamento por Ressonância Magnética , Masculino , Próstata , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Qualidade de Vida , Radiocirurgia/efeitos adversos
18.
J Comput Assist Tomogr ; 46(4): 523-529, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35405714

RESUMO

OBJECTIVE: The aim of the study was to compare the distribution of Prostate Imaging and Reporting Data System (PI-RADS) scores, interreader agreement, and diagnostic performance of PI-RADS v2.0 and v2.1 for transition zone (TZ) lesions. METHODS: The study included 202 lesions in 202 patients who underwent 3T prostate magnetic resonance imaging showing a TZ lesion that was later biopsied with magnetic resonance imaging/ultrasound fusion. Five abdominal imaging faculty reviewed T2-weighted imaging and high b value/apparent diffusion coefficient images in 2 sessions. Cases were randomized using a crossover design whereby half in the first session were reviewed using v2.0 and the other half using v2.1, and vice versa for the 2nd session. Readers provided T2-weighted imaging and DWI scores, from which PI-RADS scores were derived. RESULTS: Interreader agreement for all PI-RADS scores had κ of 0.37 (v2.0) and 0.26 (v2.1). For 4 readers, the percentage of lesions retrospectively scored PI-RADS 1 increased greater than 5% and PI-RADS 2 score decreased greater than 5% from v2.0 to v2.1. For 2 readers, the percentage scored PI-RADS 3 decreased greater than 5% and, for 2 readers, increased greater than 5%. The percentage of PI-RADS 4 and 5 lesions changed less than 5% for all readers. For the 4 readers with increased frequency of PI-RADS 1 using v2.1, 4% to 16% were Gleason score ≥3 + 4 tumor. Frequency of Gleason score ≥3 + 4 in PI-RADS 3 lesions increased for 2 readers and decreased for 1 reader. Sensitivity of PI-RADS of 3 or greater for Gleason score ≥3 + 4 ranged 76% to 90% (v2.0) and 69% to 96% (v2.1). Specificity ranged 32% to 64% (v2.0) and 25% to 72% (v2.1). Positive predictive value ranged 43% to 55% (v2.0) and 41% to 58% (v2.1). Negative predictive value ranged 82% to 87% (v2.0) and 81% to 91% (v2.1). CONCLUSIONS: Poor interreader agreement and lack of improvement in diagnostic performance indicate an ongoing need to refine evaluation of TZ lesions.


Assuntos
Próstata , Neoplasias da Próstata , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Gradação de Tumores , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos
19.
Front Neurol ; 13: 746640, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35356457

RESUMO

Background: The capability in applying information communication technology (ICT) is crucial to the functional independence of older peoples of community living nowadays. The proper assessment of individuals' capability of ICT application is the corner stone for the future development of telemedicine in our aging population. Methods: With the recruitment of 300 participants of different functional and social background in home-living, hostel-living, and care-and-attention home living; and through assessing the ability of individuals in instrumental activities of daily living and cognitive assessments, this study aimed at capturing the content validity and construct validity of the Advanced Instrumental Activities of Daily Living (AIADL scale). In addition, this study assess the ability of older peoples in applying ICT and how the functional and social background affects their independence in aging-in-place. Results: The AIADL scale showed good test-retest reliability and good-to-excellent internal consistency. To determine if items of the AIADL scale measure various aspects of community living, exploratory factor analysis revealed a two-factor structure with "home living and management" and "community living". Validity analysis with the known-groups method showed a high overall accuracy of prediction of individuals' capability of independent living in the community. Conclusions: The AIADL scale is a valid and reliable instrument to assess the ability of older adults in handling ICT as part of their instrumental activities in daily living. The scale can reflect capability of older peoples in applying ICT. This instrument can serve as a reference in measuring readiness of individuals in receiving telemedicine and their ability of aging-in-place.

20.
Clin Pharmacol Ther ; 111(1): 243-251, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34424534

RESUMO

Electronic health record (EHR) discontinuity (i.e., receiving care outside of the study EHR system), can lead to information bias in EHR-based real-world evidence (RWE) studies. An algorithm has been previously developed to identify patients with high EHR-continuity. We sought to assess whether applying this algorithm to patient selection for inclusion can reduce bias caused by data-discontinuity in four RWE examples. Among Medicare beneficiaries aged >=65 years from 2007 to 2014, we established 4 cohorts assessing drug effects on short-term or long-term outcomes, respectively. We linked claims data with two US EHR systems and calculated %bias of the multivariable-adjusted effect estimates based on only EHR vs. linked EHR-claims data because the linked data capture medical information recorded outside of the study EHR. Our study cohort included 77,288 patients in system 1 and 60,309 in system 2. We found the subcohort in the lowest quartile of EHR-continuity captured 72-81% of the short-term and only 21-31% of the long-term outcome events, leading to %bias of 6-99% for the short-term and 62-112% for the long-term outcome examples. This trend appeared to be more pronounced in the example using a nonuser comparison rather than an active comparison. We did not find significant treatment effect heterogeneity by EHR-continuity for most subgroups across empirical examples. In EHR-based RWE studies, investigators may consider excluding patients with low algorithm-predicted EHR-continuity as the EHR data capture relatively few of their actual outcomes, and treatment effect estimates in these patients may be unreliable.


Assuntos
Registros Eletrônicos de Saúde/estatística & dados numéricos , Demandas Administrativas em Assistência à Saúde , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Viés , Estudos de Coortes , Continuidade da Assistência ao Paciente , Registros Eletrônicos de Saúde/tendências , Feminino , Humanos , Estudos Longitudinais , Masculino , Medicare , Pessoa de Meia-Idade , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...