Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Mater ; 30(39): e1803550, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30109736

RESUMO

Blinding disorders of the outer retina involve dysfunction and degeneration of photoreceptors. One potential approach to treat these forms of blindness is to repopulate the outer retina via a simple bolus injection of donor photoreceptors. However, this may not be ideal due to the highly polarized organization of photoreceptors that include apical light sensing photopigments and basal axon terminals. Furthermore, bolus injections create uncertainty with regard to the area, density, and retention of donor cells. Here, a novel and robust microfabrication process is developed to create 3D, micrometer-sized complex structures in ultrathin and biocompatible elastomer films (nonbiodegradable polydimethylsiloxane and biodegradable poly(glycerol-sebacate)) that can serve as polarizable photoreceptor delivery scaffolds, consisting of an array of cup-shaped photoreceptor capture wells that funnel into a microchannel. This "wine glass" scaffold design promotes efficient capture of human pluripotent stem-cell-derived photoreceptor cell bodies and guidance of basal axon extensions, ultimately achieving a uniform level of organization and polarization that is not possible with bolus injections or previously described scaffolds. In addition to future therapeutic applications, our scaffold design and materials provide a platform to generate reproducible and scalable in vitro models of photoreceptor-based diseases.


Assuntos
Células Fotorreceptoras , Polaridade Celular , Elastômeros , Humanos , Células-Tronco Pluripotentes , Retina , Alicerces Teciduais
2.
ACS Appl Mater Interfaces ; 10(9): 8117-8123, 2018 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-29345131

RESUMO

Photolithography based on optical mask is widely used in academic research laboratories due to its low cost, simple mechanism, and ability to pattern in micron-sized features on a wafer-scale area. Because the resolution is bound by diffraction limits of the light source, nanoscale patterning using photolithography requires short-wavelength light source combined with sophisticated optical elements, adding complexity and cost. In this paper, a novel method of subwavelength patterning process using conventional i-line mercury lamp is introduced, without the use of such advanced optical tools. The method utilizes the re-entrant geometry of image reversal photoresist produced from the developing process, where a secondary mask is generated by isotropically depositing a metal layer to cover the re-entrant profile of the photoresist. Removing the photoresist by applying ultrasonic vibrations in acetone bath uniformly cracks the metal layer at the sidewalls of the re-entrant profile, exposing the substrate with a reduced feature size. The width of the initial mask pattern can be reduced by 400 nm in a controlled manner, regardless of the original width choice. As a result, the method is shown to achieve sub-100 nm scale linear patterns compatible for both subsequent deposition process and dry-etching process. Our approach is applicable to various shapes of the patterns and can be used in electronic device fabrication requiring nanoscale lithography patterning, such as the gate fabrication of AlGaN/GaN high-electron-mobility transistor.

3.
Appl Phys Lett ; 109(15): 152105, 2016 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-27795570

RESUMO

Flexible graphene transistors built on a biocompatible Parylene C substrate would enable active circuitry to be integrated into flexible implantable biomedical devices. An annealing method to improve the performance of a flexible transistor without damaging the flexible substrate is also desirable. Here, we present a fabrication method of a flexible graphene transistor with a bottom-gate coplanar structure on a Parylene C substrate. Also, a current annealing method and its effect on the device performance have been studied. The localized heat generated by the current annealing method improves the drain current, which is attributed to the decreased contact resistance between graphene and S/D electrodes. A maximum current annealing power in the Parylene C-based graphene transistor has been extracted to provide a guideline for an appropriate current annealing. The fabricated flexible graphene transistor shows a field-effect mobility, maximum transconductance, and a Ion/Ioff ratio of 533.5 cm2/V s, 58.1 µS, and 1.76, respectively. The low temperature process and the current annealing method presented here would be useful to fabricate two-dimensional materials-based flexible electronics.

4.
Opt Express ; 24(15): 16894-903, 2016 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-27464141

RESUMO

In this study, the light absorption property of Ge nanomembrane (Ge NM), which incorporates hydrogen (H), in near-infrared (NIR) wavelength range was analyzed. Due to the presence of a large amount of structural defects, the light absorption coefficient of the Ge layer becomes much higher (10 times) than that of bulk Ge in the wavelength range of 1000 ~1600 nm. Increased light absorption was further measured from released Ge NM that has H incorporation in comparison to that of bulk Ge, proving the enhanced light absorption coefficient of H incorporated Ge. Finally, metal-semiconductor-metal (MSM) photodetectors were demonstrated using the H incorporated Ge on GeOI.

5.
J Surg Res ; 197(1): 210-7, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25935469

RESUMO

BACKGROUND: Detecting failing tissue flaps before they are clinically apparent has the potential to improve postoperative flap management and salvage rates. This study demonstrates a model to quantitatively compare clinical appearance, as recorded via digital camera, with spatial frequency domain imaging (SFDI), a noninvasive imaging technique using patterned illumination to generate images of total hemoglobin and tissue oxygen saturation (stO2). METHODS: Using a swine pedicle model in which blood flow was carefully controlled with occlusion cuffs and monitored with ultrasound probes, throughput was reduced by 25%, 50%, 75%, and 100% of baseline values in either the artery or the vein of each of the flaps. The color changes recorded by a digital camera were quantified to predict which occlusion levels were visible to the human eye. SFDI was also used to quantify the changes in physiological parameters including total hemoglobin and oxygen saturation associated with each occlusion. RESULTS: There were no statistically significant changes in color above the noticeable perception levels associated with human vision during any of the occlusion levels. However, there were statistically significant changes in total hemoglobin and stO2 levels detected at the 50%, 75%, and 100% occlusion levels for arterial and venous occlusions. CONCLUSIONS: As demonstrated by the color imaging data, visual flap changes are difficult to detect until significant occlusion has occurred. SFDI is capable of detecting changes in total hemoglobin and stO2 as a result of partial occlusions before they are perceivable, thereby potentially improving response times and salvage rates.


Assuntos
Percepção de Cores , Retalhos de Tecido Biológico/irrigação sanguínea , Imagem Óptica , Fotografação , Animais , Biomarcadores/sangue , Retalhos de Tecido Biológico/fisiologia , Hemoglobinas/metabolismo , Oxigênio/sangue , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...