Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Front Cell Neurosci ; 17: 1287089, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38026689

RESUMO

While there is a growing appreciation of three-dimensional (3D) neural tissues (i.e., hydrogel-based, organoids, and spheroids), shown to improve cellular health and network activity to mirror brain-like activity in vivo, functional assessment using current electrophysiology techniques (e.g., planar multi-electrode arrays or patch clamp) has been technically challenging and limited to surface measurements at the bottom or top of the 3D tissue. As next-generation MEAs, specifically 3D MEAs, are being developed to increase the spatial precision across all three dimensions (X, Y, Z), development of improved computational analytical tools to discern region-specific changes within the Z dimension of the 3D tissue is needed. In the present study, we introduce a novel computational analytical pipeline to analyze 3D neural network activity recorded from a "bottom-up" 3D MEA integrated with a 3D hydrogel-based tissue containing human iPSC-derived neurons and primary astrocytes. Over a period of ~6.5 weeks, we describe the development and maturation of 3D neural activity (i.e., features of spiking and bursting activity) within cross sections of the 3D tissue, based on the vertical position of the electrode on the 3D MEA probe, in addition to network activity (identified using synchrony analysis) within and between cross sections. Then, using the sequential addition of postsynaptic receptor antagonists, bicuculline (BIC), 2-amino-5-phosphonovaleric acid (AP-5), and 6-cyano-5-nitroquinoxaline-2,3-dione (CNQX), we demonstrate that networks within and between cross sections of the 3D hydrogel-based tissue show a preference for GABA and/or glutamate synaptic transmission, suggesting differences in the network composition throughout the neural tissue. The ability to monitor the functional dynamics of the entire 3D reconstructed neural tissue is a critical bottleneck; here we demonstrate a computational pipeline that can be implemented in studies to better interpret network activity within an engineered 3D neural tissue and have a better understanding of the modeled organ tissue.

3.
Lab Chip ; 20(5): 901-911, 2020 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-31976505

RESUMO

Three-dimensional (3D) in vitro models have become increasingly popular as systems to study cell-cell and cell-ECM interactions dependent on the spatial, mechanical, and chemical cues within the environment of the tissue, which is limited in traditional two-dimensional (2D) models. Although electrophysiological recordings of neuronal action potentials through 2D microelectrode arrays (MEAs) are a common and trusted method of evaluating neuronal function, network communication, and response to chemicals and biologicals, there are currently limited options for measuring electrophysiological activity from many locations simultaneously throughout a 3D network of neurons in vitro. Here, we have developed a thin-film, 3D flexible microelectrode array (3DMEA) that non-invasively interrogates a 3D culture of neurons and can accommodate 256 channels of recording or stimulation. Importantly, the 3DMEA is straightforward to fabricate and integrates with standard commercially available electrophysiology hardware. Polyimide probe arrays were microfabricated on glass substrates and mechanically actuated to collectively lift the arrays into a vertical position, relying solely on plastic deformation of their base hinge regions to maintain vertical alignment. Human induced pluripotent stem cell (hiPSC)-derived neurons and astrocytes were entrapped in a collagen-based hydrogel and seeded onto the 3DMEA, enabling growth of suspended cells in the matrix and the formation and maturation of a neural network around the 3DMEA probes. The 3DMEA supported the growth of functional neurons in 3D with action potential spike and burst activity recorded over 45 days in vitro. This platform is an important step in facilitating noninvasive electrophysiological characterization of 3D networks of electroactive cells in vitro.


Assuntos
Células-Tronco Pluripotentes Induzidas , Potenciais de Ação , Encéfalo , Humanos , Microeletrodos , Neurônios
4.
J Vis Exp ; (152)2019 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-31633681

RESUMO

Simultaneous recordings from large populations of individual neurons across distributed brain regions over months to years will enable new avenues of scientific and clinical development. The use of flexible polymer electrode arrays can support long-lasting recording, but the same mechanical properties that allow for longevity of recording make multiple insertions and integration into a chronic implant a challenge. Here is a methodology by which multiple polymer electrode arrays can be targeted to a relatively spatially unconstrained set of brain areas. The method utilizes thin-film polymer devices, selected for their biocompatibility and capability to achieve long-term and stable electrophysiologic recording interfaces. The resultant implant allows accurate and flexible targeting of anatomically distant regions, physical stability for months, and robustness to electrical noise. The methodology supports up to sixteen serially inserted devices across eight different anatomic targets. As previously demonstrated, the methodology is capable of recording from 1024 channels. Of these, the 512 channels in this demonstration used for single neuron recording yielded 375 single units distributed across six recording sites. Importantly, this method also can record single units for at least 160 days. This implantation strategy, including temporarily bracing each device with a retractable silicon insertion shuttle, involves tethering of devices at their target depths to a skull-adhered plastic base piece that is custom-designed for each set of recording targets, and stabilization/protection of the devices within a silicone-filled, custom-designed plastic case. Also covered is the preparation of devices for implantation, and design principles that should guide adaptation to different combinations of brain areas or array designs.


Assuntos
Eletrodos Implantados/normas , Fenômenos Eletrofisiológicos/fisiologia , Polímeros/normas , Animais , Ratos
5.
J Neural Eng ; 16(6): 066021, 2019 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-31216526

RESUMO

OBJECTIVE: Electrode arrays for chronic implantation in the brain are a critical technology in both neuroscience and medicine. Recently, flexible, thin-film polymer electrode arrays have shown promise in facilitating stable, single-unit recordings spanning months in rats. While array flexibility enhances integration with neural tissue, it also requires removal of the dura mater, the tough membrane surrounding the brain, and temporary bracing to penetrate the brain parenchyma. Durotomy increases brain swelling, vascular damage, and surgical time. Insertion using a bracing shuttle results in additional vascular damage and brain compression, which increase with device diameter; while a higher-diameter shuttle will have a higher critical load and more likely penetrate dura, it will damage more brain parenchyma and vasculature. One way to penetrate the intact dura and limit tissue compression without increasing shuttle diameter is to reduce the force required for insertion by sharpening the shuttle tip. APPROACH: We describe a novel design and fabrication process to create silicon insertion shuttles that are sharp in three dimensions and can penetrate rat dura, for faster, easier, and less damaging implantation of polymer arrays. Sharpened profiles are obtained by reflowing patterned photoresist, then transferring its sloped profile to silicon with dry etches. MAIN RESULTS: We demonstrate that sharpened shuttles can reliably implant polymer probes through dura to yield high quality single unit and local field potential recordings for at least 95 days. On insertion directly through dura, tissue compression is minimal. SIGNIFICANCE: This is the first demonstration of a rat dural-penetrating array for chronic recording. This device obviates the need for a durotomy, reducing surgical time and risk of damage to the blood-brain barrier. This is an improvement to state-of-the-art flexible polymer electrode arrays that facilitates their implantation, particularly in multi-site recording experiments. This sharpening process can also be integrated into silicon electrode array fabrication.


Assuntos
Encéfalo/fisiologia , Dura-Máter/fisiologia , Eletrodos Implantados , Desenho de Equipamento/métodos , Microtecnologia/métodos , Silício , Animais , Materiais Biocompatíveis , Desenho de Equipamento/instrumentação , Masculino , Microeletrodos , Microtecnologia/instrumentação , Ratos , Ratos Long-Evans
6.
Neuron ; 101(1): 21-31.e5, 2019 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-30502044

RESUMO

The brain is a massive neuronal network, organized into anatomically distributed sub-circuits, with functionally relevant activity occurring at timescales ranging from milliseconds to years. Current methods to monitor neural activity, however, lack the necessary conjunction of anatomical spatial coverage, temporal resolution, and long-term stability to measure this distributed activity. Here we introduce a large-scale, multi-site, extracellular recording platform that integrates polymer electrodes with a modular stacking headstage design supporting up to 1,024 recording channels in freely behaving rats. This system can support months-long recordings from hundreds of well-isolated units across multiple brain regions. Moreover, these recordings are stable enough to track large numbers of single units for over a week. This platform enables large-scale electrophysiological interrogation of the fast dynamics and long-timescale evolution of anatomically distributed circuits, and thereby provides a new tool for understanding brain activity.


Assuntos
Encéfalo/fisiologia , Eletrodos Implantados/normas , Fenômenos Eletrofisiológicos/fisiologia , Rede Nervosa/fisiologia , Polímeros/normas , Animais , Eletrodos Implantados/tendências , Masculino , Ratos , Ratos Long-Evans
7.
Neuron ; 95(6): 1381-1394.e6, 2017 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-28910621

RESUMO

Understanding the detailed dynamics of neuronal networks will require the simultaneous measurement of spike trains from hundreds of neurons (or more). Currently, approaches to extracting spike times and labels from raw data are time consuming, lack standardization, and involve manual intervention, making it difficult to maintain data provenance and assess the quality of scientific results. Here, we describe an automated clustering approach and associated software package that addresses these problems and provides novel cluster quality metrics. We show that our approach has accuracy comparable to or exceeding that achieved using manual or semi-manual techniques with desktop central processing unit (CPU) runtimes faster than acquisition time for up to hundreds of electrodes. Moreover, a single choice of parameters in the algorithm is effective for a variety of electrode geometries and across multiple brain regions. This algorithm has the potential to enable reproducible and automated spike sorting of larger scale recordings than is currently possible.


Assuntos
Potenciais de Ação/fisiologia , Algoritmos , Neurônios/fisiologia , Processamento de Sinais Assistido por Computador , Software , Animais , Automação , Encéfalo/fisiologia , Masculino , Ratos
8.
J Neurosci Methods ; 267: 14-20, 2016 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-27060384

RESUMO

BACKGROUND: Current source density analysis of recordings from penetrating electrode arrays has traditionally been used to examine the layer- specific cortical activation and plastic changes associated with changed afferent input. We report on a related analysis, the second spatial derivative (SSD) of surface local field potentials (LFPs) recorded using custom designed thin-film polyimide substrate arrays. RESULTS: SSD analysis of tone- evoked LFPs generated from the auditory cortex under the recording array demonstrated a stereotypical single local minimum, often flanked by maxima on both the caudal and rostral sides. In contrast, tone-pips at frequencies not represented in the region under the array, but known (on the basis of normal tonotopic organization) to be represented caudal to the recording array, had a more complex pattern of many sources and sinks. COMPARISON WITH EXISTING METHODS: Compared to traditional analysis of LFPs, SSD analysis produced a tonotopic map that was more similar to that obtained with multi-unit recordings in a normal-hearing animal. Additionally, the statistically significant decrease in the number of acoustically responsive cortical locations in partially deafened cats following 6 months of cochlear implant use compared to unstimulated cases observed with multi-unit data (p=0.04) was also observed with SSD analysis (p=0.02), but was not apparent using traditional analysis of LFPs (p=0.6). CONCLUSIONS: SSD analysis of surface LFPs from the thin-film array provides a rapid and robust method for examining the spatial distribution of cortical activity with improved spatial resolution compared to more traditional LFP recordings.


Assuntos
Córtex Auditivo/fisiologia , Percepção Auditiva/fisiologia , Eletrodos Implantados , Processamento de Sinais Assistido por Computador , Estimulação Acústica , Animais , Córtex Auditivo/fisiopatologia , Gatos , Implantes Cocleares , Surdez/fisiopatologia , Surdez/reabilitação , Modelos Animais de Doenças , Desenho de Equipamento , Potenciais Evocados Auditivos , Canamicina
9.
J Vis Exp ; (79): e50609, 2013 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-24121443

RESUMO

Microelectrode arrays for neural interface devices that are made of biocompatible thin-film polymer are expected to have extended functional lifetime because the flexible material may minimize adverse tissue response caused by micromotion. However, their flexibility prevents them from being accurately inserted into neural tissue. This article demonstrates a method to temporarily attach a flexible microelectrode probe to a rigid stiffener using biodissolvable polyethylene glycol (PEG) to facilitate precise, surgical insertion of the probe. A unique stiffener design allows for uniform distribution of the PEG adhesive along the length of the probe. Flip-chip bonding, a common tool used in microelectronics packaging, enables accurate and repeatable alignment and attachment of the probe to the stiffener. The probe and stiffener are surgically implanted together, then the PEG is allowed to dissolve so that the stiffener can be extracted leaving the probe in place. Finally, an in vitro test method is used to evaluate stiffener extraction in an agarose gel model of brain tissue. This approach to implantation has proven particularly advantageous for longer flexible probes (>3 mm). It also provides a feasible method to implant dual-sided flexible probes. To date, the technique has been used to obtain various in vivo recording data from the rat cortex.


Assuntos
Implantes Absorvíveis , Adesivos/química , Encéfalo/fisiologia , Microeletrodos , Polietilenoglicóis/química , Animais , Encéfalo/cirurgia , Camundongos
10.
Artigo em Inglês | MEDLINE | ID: mdl-24109995

RESUMO

We report a novel nano-cluster platinum (NCPt) film that exhibits enhanced performance as an electrode material for neural stimulation applications. Nano-cluster films were deposited using a custom physical vapor deposition process and patterned on a flexible polyimide microelectrode array using semiconductor processing technology. Electrode performance was characterized in vitro using electrochemical impedance spectroscopy and compared with sputtered thinfilm platinum (TFPt) electrodes. We characterized electrode impedance, charge storage capacity, voltage transient properties, and relative surface area enhancement in vitro. Preliminary lifetime testing of the electrode reveals that the NCPt electrodes degrade more slowly than TFPt electrodes. The combination of material biocompatibility, electrochemical performance, and preliminary lifetime results point to a promising new electrode material for neural interface devices.


Assuntos
Estimulação Elétrica/métodos , Platina/química , Impedância Elétrica , Técnicas Eletroquímicas , Eletrodos , Elétrons , Microscopia Eletrônica de Varredura , Microtecnologia , Nanopartículas/química , Imagem Óptica
11.
Magn Reson Med ; 53(2): 474-8, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15678546

RESUMO

As another step toward extracting quantitative information from hyperpolarized 3He MRI, airway diameters in humans were measured from projection images and multislice images of the lungs. Values obtained were in good agreement with the Weibel lung morphometry model. The measurement of airway caliber can now be achieved without the use of ionizing radiation. Furthermore, it was demonstrated that 3D airway tree renderings could be constructed from the multislice data. Both the measurement of airway diameters and the rendering of 3D airway information hold promise for the clinical assessment of bronchoconstrictive diseases such as asthma and the associated evaluation of treatment effectiveness. Work is being done to address the uncertainties of the manually intensive methods we have developed.


Assuntos
Anatomia Transversal/métodos , Brônquios/anatomia & histologia , Hélio , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Administração por Inalação , Aerossóis/administração & dosagem , Simulação por Computador , Meios de Contraste , Hélio/administração & dosagem , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Radiology ; 227(2): 575-9, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12663822

RESUMO

Dynamic hyperpolarized helium 3 (3He) magnetic resonance (MR) imaging of the human airways is achieved by using a fast gradient-echo pulse sequence during inhalation. The resulting dynamic images show differential contrast enhancement of both distal airways and the lung periphery, unlike static hyperpolarized 3He MR images on which only the lung periphery is seen. With this technique, up to seventh-generation airway branching can be visualized.


Assuntos
Hélio , Isótopos , Pulmão/anatomia & histologia , Imageamento por Ressonância Magnética , Adulto , Estudos de Viabilidade , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...