Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
BMC Cardiovasc Disord ; 24(1): 42, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38218796

RESUMO

BACKGROUND: The muscle artifacts, caused by prominent muscle contractions, mimicking cardiac arrhythmias, might compromise the ECG signal quality and the implantable loop recorder memory capacity in patients with epilepsy. We developed an epileptic seizures clinical pattern-based implantable loop recorder manual activation algorithm, presenting its real-world efficacy here. METHODS: One hundred ninety-three patients (18-60 years) with drug-resistant focal epilepsy were consecutively enrolled and underwent a subcutaneous loop recorder implantation. Patients with focal onset-aware seizures and patients with focal impaired awareness seizures /bilateral tonic-clonic seizures without aura were recommended to use the activator once - just after the episode. Patients with focal impaired awareness seizures/bilateral tonic-clonic seizures with aura, the caregivers of patients experiencing status epilepticus, were advised to use the activator twice - during the aura and after the episode/ regaining consciousness. RESULTS: Six thousand four hundred ninety-four ECG traces (4826 - auto-triggered events, 1668 - person-activated events) were recorded and analyzed. The rate of true positive events in the person-activated group was statistically higher than in the autoactivation group (72.5% vs.19.4%, p < 0.0001). Person-activated false-positive events were observed in 30.5% of patients with focal impaired awareness seizures and 27.7% in patients with bilateral tonic-clonic seizures. The highest rate of false-positive events (61.5%) was detected in patients undergoing epileptic status, and the lowest rate (3.8%) - was in patients with focal onset aware seizures. The rate of false-positive events was significantly higher in patients with impaired awareness seizures without aura both in focal impaired awareness (45.5% vs. 19.3%, p < 0.0001) and bilateral tonic-clonic seizure groups (38.8% vs. 5.9%, p < 0.0001). CONCLUSIONS: Arrhythmias with varying clinical outcomes are expected in epilepsy patients and have been monitored continuously. The specified loop recorder external activation algorithm can improve the clinically relevant cardiac arrhythmia detection accuracy in epilepsy patients and the value of future studies.


Assuntos
Epilepsia Tônico-Clônica , Epilepsia , Humanos , Epilepsia Tônico-Clônica/diagnóstico , Convulsões/diagnóstico , Arritmias Cardíacas , Algoritmos , Eletrocardiografia
2.
Eur Heart J Case Rep ; 6(1): ytab525, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35028502

RESUMO

BACKGROUND: Acute post-ablation pericarditis is the most common complication of epicardial ablation of ventricular arrhythmias, while regional pericarditis following an initially uneventful endocardial catheter ablation (CA) procedure is a rare and elusive diagnosis. CASE SUMMARY: We report a case of a 66-year-old Russian female who developed chest pain accompanied by electrocardiogram (ECG) changes-biphasic T waves in V1-V4 leads after an initially uncomplicated premature ventricular complex CA procedure. After examination and investigations, including transthoracic echocardiography (TTE), cardiac magnetic resonance imaging (CMR) and cardiac computed tomography (CCT), she was diagnosed with regional pericarditis, which occurred even though the ablation was uneventful with the limited number of radiofrequency applications. Furthermore, the diagnosis was difficult due to normal body temperature and the absence of pericardial effusion and myocardial abnormalities on TTE, findings that are not characteristic of pericarditis. The patient's last office visit was in 6 months after the procedure. Neither patient had any complaintsnor there were any changes on ECG and TTE. DISCUSSION: Regional post-ablation pericarditis is a relatively rare type of post-cardiac injury syndrome (PCIS). The varying severity of the PCIS clinical course makes the diagnosis of post-ablation pericarditis initially difficult, especially in patients undergoing an uneventful CA procedure. Non-invasive imaging modalities as CMR and CCT should be considered initially in elusive cases of PCIS.

3.
BMC Cardiovasc Disord ; 21(1): 483, 2021 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-34620082

RESUMO

BACKGROUND: Early recurrences of atrial arrhythmias (ERAA) after atrial fibrillation (AF) catheter ablation do not predict procedural failure. A well-demarcated homogeneous lesion delivered by cryoballoon is less arrhythmogenic, and the recommended three-months blanking period may not refer to cryoballoon ablation (CBA). OBJECTIVE: We aimed to evaluate the predictive role of ERAA after second-generation CBA using an implantable loop recorder. METHODS: This prospective observational study enrolled 100 patients (58 males, median age 58) with paroxysmal/persistent AF undergoing pulmonary vein (PV) CBA using second-generation cryoballoon with simultaneous ECG loop recorder implantation. The duration of follow-up was 12 months, with scheduled visits at 3, 6 and 12 months. RESULTS: 99 patients from 100 completed the 12-month follow-up period. ERAA occurred in 31.3 % of patients. 83.9 % of patients with ERAA also developed late recurrences. The 12-month freedom from AF in patients with ERAA was significantly lower than in those without ERAA (p < 0.0001). Non-paroxysmal AF and longer arrhythmia history were associated with increased risk of both early (HR 3.27; 95 % CI 1.32-8.08; p = 0.010 and HR 1.0147; 95 % CI 1.008-1.086; p = 0.015, respectively) and late recurrences (HR 3.89; 95 % CI 1.67-9.04; p = 0.002 and HR 1.0142; 95 % CI 1.007-1.078; p = 0.019, respectively) of AF. ERAA were another predictor for procedural failure (HR 15.2; 95 % CI (6.42-35.99; p = 0.019). CONCLUSIONS: ERAA occurred in the third of the patients after PV second-generation CBA and are strongly associated with procedural failure. Longer duration of AF history and persistent AF are independent predictors of AF's early and late recurrence.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Eletrocardiografia Ambulatorial , Veias Pulmonares/cirurgia , Tecnologia de Sensoriamento Remoto , Potenciais de Ação , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Eletrocardiografia Ambulatorial/instrumentação , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Tecnologia de Sensoriamento Remoto/instrumentação , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
Heart Rhythm ; 18(2): 221-228, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32911052

RESUMO

BACKGROUND: Cardiac rhythm and conduction disorders are common in patients with epilepsy and are presumably one of the leading causes of sudden unexpected death. There are only a few published reports on ictal cardiac arrhythmias detected by continuous monitoring, and the majority had a small sample size. OBJECTIVE: The aim of this study was to evaluate the frequency and type of cardiac arrhythmias recorded by an implantable loop recorder in patients with drug-resistant epilepsy. METHODS: We implanted a subcutaneous loop recorder to 193 patients with drug-resistant epilepsy. Automatic triggers to initiate cardiac rhythm recording were cardiac pauses of >3 seconds and any episodes of bradycardia (≤45 beats/min) or tachycardia (≥150 beats/min). Patients/relatives were instructed to begin peri-ictal rhythm recording by using an external activator device. The follow-up duration was 36 months, with scheduled follow-up visits every 3 months. RESULTS: A total of 6494 electrocardiogram traces were recorded during the median follow-up of 36 months (interquartile range 3-36 months). Ictal heart rhythm and rate changes were detected in 143 patients (74%). The most common finding was ictal sinus tachycardia (66.8%). Sinus bradycardia was observed in 13 patients (6.7%). Three patients had clinically relevant cardiac pauses of >6 seconds, requiring permanent pacemaker implantation. Five patients (2.6%) died suddenly. CONCLUSION: Ictal heart rhythm and rate changes occur in most of the patients with drug-resistant epilepsy. Clinically relevant cardiac events, related to ictal and postictal periods, are rare. No potentially malignant arrhythmias were detected in patients who died suddenly during the preceding follow-up period.


Assuntos
Arritmias Cardíacas/etiologia , Eletrocardiografia Ambulatorial/métodos , Eletrocardiografia/métodos , Frequência Cardíaca/fisiologia , Morte Súbita Inesperada na Epilepsia/epidemiologia , Adolescente , Adulto , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/fisiopatologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Federação Russa/epidemiologia , Taxa de Sobrevida/tendências , Fatores de Tempo , Adulto Jovem
5.
Biomed Res Int ; 2020: 2352648, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33224976

RESUMO

PURPOSE: This multicenter, prospective registry evaluated the comparative safety and efficacy of left atrial appendage occlusion (LAAO) using the Watchman device (WD) and the Amplatzer Cardiac Plug (ACP) in patients with nonvalvular atrial fibrillation (NVAF) in real-world clinical practice in Russia. METHODS: The study included data from 200 consecutive NVAF patients (66.8 ± 7.8 years, 44.5% female, median CHA2DS2VASc 4, median HAS-BLED 3) who had undergone LAAO implantation using WD (n = 108) or ACP (n = 92) from September 2015 to December 2017 in 5 medical centers in Russia. The primary safety endpoint was the procedure-related major adverse events, and the primary efficacy endpoint was the composite of thromboembolic events, device thrombosis, hemorrhagic events, and unexplained death during the 12-month follow-up. RESULTS: Successful LAAO was performed in all 92 (100%) patients with ACP and 105 (97.2%) with WD (p = 0.053). At 12 months, primary safety endpoint occurred in 6.5% of patients in the ACP group with no events in the WD group (6.5% vs. 0%, p = 0.008). During the 12-month follow-up, the primary efficacy endpoint has occurred in 8.3% of patients in the WD group (n = 9) and 1.1% of patients in the ACP group (n = 1) (p = 0.016). CONCLUSIONS: In this multicenter prospective registry, LAA closure with the WD was associated with significantly higher thromboembolic events rate in NVAF patients. Patients, receiving the ACP, had more procedure-related major adverse events. However, further multicenter studies are necessary to evaluate these findings.


Assuntos
Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/instrumentação , Idoso , Anticoagulantes/uso terapêutico , Apêndice Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Dispositivo para Oclusão Septal , Tromboembolia/prevenção & controle , Resultado do Tratamento
6.
Eur Heart J Case Rep ; 4(3): 1-6, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32617466

RESUMO

BACKGROUND: Catheter ablation (CA) of epicardial accessory pathways (APs) can be performed via the coronary sinus (CS) system. Variable CS anatomy with complications of former CA procedures inside the CS venous system may require using alternative CA approach and technology. CASE SUMMARY: We report the case of a 23-year-old man with Wolff-Parkinson-White syndrome and history of aborted sudden cardiac death (SCD) and unsuccessful previous AP radiofrequency ablation (RFA). CS venography during the redo procedure revealed an early CS trifurcation with cardiac veins stenosis, thus with difficulties in maintaining cardiac veins' access and catheter manoeuvring inside CS venous system. The last office visit with electrocardiogram (ECG) performance was in 3 months after the CA. Neither delta wave on the ECG nor any complaints/adverse health effects was detected at that time. DISCUSSION: Successful CA of epicardial AP in patients with a high risk of SCD is essential. However, CS complex anatomy and changes after former RFA inside it may lead to CS venous system access limitations. Alternative CA approach and technology should be considered to ensure CS venous system cannulation and epicardial AP CA performance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...