Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Respir Med Case Rep ; 40: 101768, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36312301

RESUMO

Objective: Despite the full range of anti-epidemic measures, the rapidly mutating SARS-CoV-2 continues to spread worldwide, causing respiratory and pulmonary pathologies. So far, there are no generally accepted clinical guidelines for treating post-resuscitation cicatricial tracheal stenosis (CTS) after COVID-19 associated pneumonia. This study sought to evaluate the clinical outcomes of surgical treatment and perioperative management of patients who developed CTS. Methods: A cohort of eleven working-age patients (eight women and three men) with CTS were treated surgically after undergoing invasive artificial ventilation ranging from 5 to 130 days. Along with scarring changes in the tracheal wall, tracheomalacia was noted in five (55.6%) individuals. Circumferential tracheal resection (CTR) with subsequent anastomosis, tracheolaryngeal reconstruction, and endoscopic methods were modalities used to restore airway patency. In cases of CTR combined with tracheoesophageal fistula (TEF), CTR was performed with dissection of the pathological stoma. Results: In 80% of the cases, CTS was located at the larynx and cervical trachea level. All patients managed to restore adequate breathing through their natural airways with preserved vocal function. No lethal outcomes were observed in the post-op period. Patient outcomes after CTR were considered excellent in nine patients who continued an active lifestyle and went straight to work. One patient, after laryngotracheoplasty and tracheal stenting, is at the final stage of treatment. Conclusions: These patients are at high risk of developing CTS and require dynamic monitoring. CTR allows early rehabilitation of patients with the best functional outcome. If CTR is contraindicated, laryngotracheoplasty also allows adequate debridement of the tracheobronchial tree and respiratory support.

2.
Respir Med Case Rep ; 34: 101558, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34877252

RESUMO

A case of the successful reconstruction of an extensive chest wall defect combined with a ventral hernia in a patient after multimodality treatment of breast cancer complicated by sternal and costal osteomyelitis is presented. To recover the chest mechanics, with emphasis on the supporting function, and to repair the hernial defect, customized reinforced "sandwich" TiNi rib endografts and knitted TiNi surgical mesh were used. A five-year follow-up indicated no recurrence of osteomyelitis or ventral hernia, and no failure/migration of the implants or instability of the thorax. Excellent clinical and functional outcomes were achieved pursuant to the Enneking score.

3.
J Funct Biomater ; 12(4)2021 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-34842727

RESUMO

In this study, we assessed the outcomes after surgical treatment of thoracic post-excision defects in 15 patients, using TiNi knitted surgical meshes and customized artificial TiNi-based ribs. METHODS: Eight patients were diagnosed with advanced non-small cell lung cancer (NSCLC) invading the chest wall, of which five patients were T3N0M0, two were T3N1M0, and one was T3N2M0. Squamous cell carcinoma was identified in three of these patients and adenocarcinoma in five. In two cases, chest wall resection and repair were performed for metastases of kidney cancer after radical nephrectomy. Three-dimensional CT reconstruction and X-ray scans were used to plan the surgery and customize the reinforcing TiNi-based implants. All patients received TiNi-based devices and were prospectively followed for a few years. RESULTS: So far, there have been no lethal outcomes, and all implanted devices were consistent in follow-up examinations. Immediate complications were noted in three cases (ejection of air through the pleural drains, paroxysm of atrial fibrillation, and pleuritis), which were conservatively managed. In the long term, no complications, aftereffects, or instability of the thoracic cage were observed. CONCLUSION: TiNi-based devices used for extensive thoracic lesion repair in this context are promising and reliable biomaterials that demonstrate good functional, clinical, and cosmetic outcomes.

4.
Biomed Mater ; 16(2): 021001, 2021 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-32629431

RESUMO

Intermetallic porous SHS-TiNi alloys exhibit tangled and specific stress-strain characteristics. This article aims to evaluate the findings emanating from experiments using standard and proprietary instruments. Fatigue testing under repeated complex loading was used to measure the total number of load cycles before failure of the SHS-TiNi samples occurred. Of the tested samples, seventy percent passed through 106 cycles without failure due to the reversible martensite transformation in the TiNi phase, one of the prevailing constituents of a multiphase matrix. The fractured surfaces were analyzed using scanning electron microscopy and confocal laser scanning instruments. Microscopy studies showed that the entire surface of the sample is concealed by miscellaneous strata that result from the SHS processand effectively protect the porous alloy in a corrosive environment. Numerous non-metallic inclusions, which are also attributed to the SHS reaction, do not have a significant impact on the deformation behavior and fatigue performance. In this context, the successful in vivo functioning of porous grafts assessed in a canine rib-plasty model allows the bone substitute to be congruentially deformed in the body without rejection or degradation; it thus has a long operational life, often greater than 17 ×106 (22 × 60 × 24 × 540) cycles. It acknowledges the potential benefits of SHS-TiNi as a superior osteoplastic material and its high resistance to corrosion fatigue.


Assuntos
Ligas , Substitutos Ósseos/química , Ligas Dentárias/química , Teste de Materiais , Níquel/química , Costelas/fisiopatologia , Resistência à Tração , Titânio/química , Animais , Corrosão , Cães , Elasticidade , Temperatura Alta , Masculino , Microscopia Confocal , Microscopia Eletrônica de Varredura , Porosidade , Pós , Costelas/metabolismo , Resistência ao Cisalhamento , Estresse Mecânico , Viscosidade , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...