Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Neurol Sci ; 191(1-2): 121-5, 2001 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-11677002

RESUMO

All patients with amyotrophic lateral sclerosis (ALS) are treated with the same dose of riluzole: 50 mg twice daily. Reasonably large interindividual differences in clearance of the drug have been reported. The relatively small group of patients with high blood concentrations of riluzole has probably primarily influenced the efficacy and the incidence of side-effects in the previously conducted clinical trials with riluzole. Individual dosing of the drug may, in the case of large interindividual differences in serum concentrations of the drug, be necessary in the future. Exact data concerning the plasma and serum concentrations of riluzole in patients with ALS, after standardized intake of the drug, diet and blood sampling are unknown so far. In this study, inter- and intraindividual variability of serum and plasma levels of riluzole in 21 patients with "probable" or "definite" ALS were determined. The interindividual variability of peak serum levels (coefficient of variation=74%) was significantly larger than intraindividual variability (p<0.001). Serum levels were not correlated with age or smoking status. The determination of a correlation between riluzole serum concentrations and survival of patients with ALS will be the aim of further studies.


Assuntos
Esclerose Lateral Amiotrófica/sangue , Variação Genética , Fármacos Neuroprotetores/sangue , Riluzol/sangue , Adulto , Fatores Etários , Idoso , Esclerose Lateral Amiotrófica/tratamento farmacológico , Análise de Variância , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Fármacos Neuroprotetores/farmacocinética , Fármacos Neuroprotetores/uso terapêutico , Reprodutibilidade dos Testes , Riluzol/farmacocinética , Riluzol/uso terapêutico , Fumar
2.
Biomed Chromatogr ; 15(2): 89-94, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11268048

RESUMO

A validated, sensitive and precise reversed-phase high-performance liquid chromatographic method for the simultaneous determination of 5-flucytosine (5-FC) and 5-fluorouracil (5-FU) in human plasma is described. Two compounds, 5-methylcytosine (5-MC) and 5-chlorouracil (5-CU), were used as internal standards for the determination of 5-FC and 5-FU, respectively. Plasma samples were deproteinized with trichloroacetic acid and chromatographed on an octylsilica column, maintained at 30 degrees C during elution, using a 0.04 M phosphate buffer, pH 7.0, as eleunt. Spectrophotometric diode array detection was used at 266 nm. 5-FC, 5-FU, 5-MC and 5-CU were found to have retention times of 4.8, 5.8, 7.7 and 11.0 min respectively. Recoveries of 91-120% with reproducibility and repeatability coefficients of variation of 0.8-6% were obtained. Mean correlation coefficients of 0.99989 and 0.9995 were found for the linear calibration curves (n = 2) of 5-FC (4.816-192.6 mg/l) and 5-FU (0.05368-5.368 mg/l), respectively. The limits of quantitation were 0.3 mg/l for 5-FC and 0.05 mg/l for 5-FU.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Flucitosina/sangue , Fluoruracila/sangue , Calibragem , Humanos , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
J Chromatogr B Biomed Sci Appl ; 734(2): 203-10, 1999 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-10595718

RESUMO

A validated and precise reversed-phase high-performance liquid chromatographic method for the determination of thalidomide in serum, with phenacetin as an internal standard, is described. Protein precipitation, using trichloroacetic acid, was used for clean-up. The aliquot was chromatographed on a octadecyl column, using an eluent composed of 250 ml 0.01 M potassium dihydrogenphosphate, adjusted to a pH of 3.0 with a 43% phosphoric acid solution, mixed with 750 ml methanol. Ultraviolet detection was used at an operation wavelength of 220 nm. Hydrolytic degradation was prevented during analysis by acidification of samples with the precipitation reagent. Thalidomide and phenacetin were found to have retention times of 7.9 and 15.0 min, respectively. Recoveries ranging from 79 to 84% were found for both components, with reproducibility relative standard deviations of 0.8-3% and repeatability coefficients of 1.2-3%. A mean correlation coefficient of 0.9995 was found for the linear calibration curve (n=2) of thalidomide with limits of quantitation of 0.222-21 mg/l. The method appeared to be feasible for pharmacokinetic studies with thalidomide.


Assuntos
Proteínas Sanguíneas , Cromatografia Líquida de Alta Pressão/métodos , Talidomida/sangue , Ácido Tricloroacético , Precipitação Química , Estabilidade de Medicamentos , Humanos , Concentração de Íons de Hidrogênio , Indicadores e Reagentes , Fenacetina/sangue , Ácidos Fosfóricos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Talidomida/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA