Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Arthroplasty ; 36(9): 3333-3339, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33958253

RESUMO

BACKGROUND: Titanium tapered stems (TTS) achieve fixation in the femoral diaphysis and are commonly used in revision total hip arthroplasty. The initial stability of a TTS is critical, but the minimum contact length needed and impact of implant-specific taper angles on axial stability are unknown. This biomechanical study was performed to better guide operative decision-making by addressing these clinical questions. METHODS: Two TTS with varying conical taper angles (2° spline taper vs 3.5° spline taper) were implanted in 9 right and left matched fresh human femora. The proximal femur was removed, and the remaining femoral diaphysis was prepared to allow for either a 2 cm (n = 6), 3 cm (n = 6), or 4 cm (n = 6) cortical contact length with each implanted stem. Stepwise axial load was then applied to a maximum of 2600N or until the femur fractured. Failure was defined as either subsidence >5 mm or femur fracture. RESULTS: All 6 femora with 2 cm of stem-cortical contact length failed axial testing, a significantly higher failure rate (P < .02) than the 4 out of 6 femora and all 6 femora that passed testing at 3 cm and 4 cm, respectively, which were not statistically different from each other (P = .12). Taper angle did not influence success rates, as each matched pair either succeeded or failed at the tested contact length. CONCLUSION: 4 cm of cortical contact length with a TTS demonstrates reliable initial axial stability, while 2 cm is insufficient regardless of taper angle. For 3 cm of cortical contact, successful initial fixation can be achieved in most cases with both taper angle designs.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Cadáver , Humanos , Desenho de Prótese , Titânio
2.
J Appl Microbiol ; 117(3): 824-33, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24849144

RESUMO

AIMS: To acquire data on the safety-in-use of the probiotic Saccharomyces cerevisiae RC016 and test its ability to reduce genotoxicity caused by dietary aflatoxins (AFs). METHODS AND RESULTS: The probiotic was orally administered to Wistar rats. Six groups (n = 6) were arranged: feed and probiotic controls, two levels of AFs-contaminated feed and two treatments including both the probiotic and the toxin. Genotoxiciy and cytotoxicity were evaluated with the bone marrow micronuclei assay and the comet assay and internal organs were macroscopically and microscopically examined. The tested S. cerevisiae strain did not cause genotoxicity or cytotoxicity in vivo, and it was able to attenuate AFs-caused genotoxicity. Saccharomyces cerevisiae RC016 did not cause any impairment on the rats' health and it showed no negative impact on the weight gain. Moreover, RC016 improved zootechnical parameters in AFs-treated animals. The beneficial effects were likely to be caused by adsorption of AFs to the yeast cell wall in the intestine and the consequent reduction in the toxin's bioavailability. CONCLUSIONS: The dietary administration of RC016 does not induce genotoxicity or cytotoxicity to rats. SIGNIFICANCE AND IMPACT OF THE STUDY: Incorporation of RC016 in the formulation of feed additives increases animal productivity. Similar effects may even occur in human food applications.


Assuntos
Probióticos/toxicidade , Saccharomyces cerevisiae , Administração Oral , Aflatoxinas/toxicidade , Ração Animal , Animais , Dano ao DNA , Masculino , Ratos , Ratos Wistar , Testes de Toxicidade Subcrônica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...