Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Heart J Suppl ; 24(Suppl B): B36-B41, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35370499

RESUMO

Cardiac computed tomography (CT) is vital for safety and efficacy of transcatheter aortic valve implantation (TAVI). We aimed to determine the accuracy of fully automated CT analysis of aortic root anatomy before TAVI by Philips HeartNavigator software. This prospective, academic, single-centre study enrolled 128 consecutive patients with native aortic valve stenosis considered for TAVI. Automated HeartNavigator software was compared to the standard manual CT analysis by experienced operators using FluoroCT software. The sizing of the aortic annulus by perimeter and area significantly differed between both methods: mean perimeter was 76.43 mm vs. 77.52 mm (P < 0.0001) using manual FluoroCT vs. automated HeartNavigator software; mean area was 465 mm2 vs. 476 mm2 (P < 0.0001). Interindividual variability testing revealed mean differences between the two operators were 1.21 mm for the aortic annulus perimeter and 9 mm2 for the aortic annulus area. The hypothetical self-expandable transcatheter prosthesis sizing resulted in 80% agreement in 80% of cases. The time required to perform the automated CT analysis was significantly shorter than the time required for manual analysis (mean 17.8 min vs. 2.1 min, P < 0.0001). Philips HeartNavigator fully automated software for pre-TAVI CT analysis is a promising technology. Differences detected in aortic annulus dimensions are small and similar to the variability of manual CT analysis. Automated prediction of optimal fluoroscopic viewing angles is accurate. Correct transcatheter prosthesis sizing requires clinical oversight.

2.
Eur Heart J Suppl ; 24(Suppl B): B23-B27, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35370506

RESUMO

Transcatheter aortic valve implantation (TAVI) has become a high-volume procedure with increasing demands on hospital resources. Local anaesthesia with sedation supervised by an anaesthesiology team is the current standard of care. We aimed to describe our experience with a simplified, nurse-led sedation (NLS) protocol. This study enrolled 128 consecutive patients who underwent transfemoral TAVI with self-expandable Evolut R prosthesis between November 2019 and April 2021. Operators selected 50% of patients for NLS based on the clinical expectation of lower risk of procedural difficulties. Nurse-led sedation protocol demanded only mild to moderate levels of sedation. The clinical outcomes were determined from the local TAVI registry and the national mortality database. Baseline patient characteristics were similar in the NLS (n = 64) and anaesthesiologist-led sedation (ALS) (n = 64) groups except higher prevalence of diabetes mellitus (48.4% vs. 31.3%, P = 0.035) and peripheral vascular disease (20.3% vs. 7.8%, P = 0.036) in the ALS group. There was a trend for the larger prostheses used in the ALS group (P = 0.058). The procedural results did not differ, and coronary care team backup was rarely needed in the NLS group (6% of patients). The in-hospital outcomes were identical from both clinical and echocardiography perspectives, and 30-day mortality was low in both groups (1.5%). For the NLS group, preparation in the catheterization laboratory was quicker by 6.4 min (P = 0.01), and intensive care unit stay was shorter (2.03 vs. 3.48 days, P = 0.001). In conclusion, the NLS for the selected transfemoral TAVI population seems safe.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...