Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 84(1): 013703, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23387655

RESUMO

We present the concept for a sample holder designed for mounting and heating of plate-like samples that is based on a clamping mechanism for easy handling. The clamping mechanism consists of a U-shaped bracket encompassing the sample support plate from the rear. Two spring wires are fixed in the walls of the bracket spanning the sample to secure it with only two point contacts. This enables the sample to freely expand or contract during heating and cooling. To accommodate for a large variety in sample size, shape, and quality, we introduce two designs differing in the generation of the clamping force: One pressing the sample against the spring wires, the other one pulling the spring wires onto the sample. Both designs yield an automatically even alignment of the sample during the mounting process to achieve an even load distribution and reliable fixation specifically for brittle samples. For high temperature treatment, the sample holders are enhanced by a resistive heating plate. As only the sample and a small fraction of the sample holder are heated, temperatures of 1300 °C are reached with only 8 W heating power. The sample support and heating components are mounted on a 11 mm × 13 mm base plate with a handle that can be transferred between the sample entry stage, the preparation stage, and surface science experiments in the ultra-high vacuum system.

2.
Phys Chem Chem Phys ; 14(44): 15361-8, 2012 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-23060225

RESUMO

The surface morphology of CeO(2)(111) single crystals and silicon supported ceria films is investigated by non-contact atomic force microscopy (NC-AFM) and Kelvin probe force microscopy (KPFM) for various annealing conditions. Annealing bulk samples at 1100 K results in small terraces with rounded ledges and steps with predominantly one O-Ce-O triple layer height while annealing at 1200 K produces well-ordered straight step edges in a hexagonal motif and step bunching. The morphology and topographic details of films are similar, however, films are destroyed upon heating them above 1100 K. KPFM images exhibit uniform terraces on a single crystal surface when the crystal is slowly cooled down, whereas rapid cooling results in a significant inhomogeneity of the surface potential. For films exhibiting large terraces, significant inhomogeneity in the KPFM signal is found even for best possible preparation conditions. Applying X-ray photoelectron spectroscopy (XPS), we find a significant contamination of the bulk ceria sample with fluorine while a possible fluorine contamination of the ceria film is below the XPS detection threshold. Time-of-flight secondary ion mass spectroscopy (TOF-SIMS) reveals an accumulation of fluorine within the first 5 nm below the surface of the bulk sample and a small concentration throughout the crystal.

3.
Rev Sci Instrum ; 83(5): 055110, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22667660

RESUMO

We present a versatile system for the preparation of oxide crystal surfaces in the ultra-high vacuum (UHV) at temperatures up to 1300 K. Thermal treatment is accomplished by direct current heating of a tantalum foil in contact with the oxide sample. The sample temperature is measured by a thermocouple at a position close to the crystal and its reading is calibrated against the surface temperature determined by a second thermocouple temporarily attached to the surface. The design of the sample holder is based on a transferable plate originally developed for a commercial UHV scanning probe microscope. The system is, however, also suitable for the use with electron spectroscopy or electron diffraction based surface analytical techniques. We present results for the high-temperature preparation of CeO(2)(111) surfaces with atomically flat terraces exhibiting perfect atomic order and cleanliness as revealed by non-contact atomic force microscopy (NC-AFM) imaging. NC-AFM imaging is, furthermore, used to demonstrate the temperature-controlled aggregation of gold atoms on the CeO(2)(111) surface and their evaporation at high temperatures.

4.
Rev Sci Instrum ; 82(7): 073703, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21806185

RESUMO

A key issue for high-resolution frequency-modulation atomic force microscopy imaging in liquids is minimizing the frequency noise, which requires a detailed analysis of the corresponding noise contributions. In this paper, we present a detailed description for modifying a commercial atomic force microscope (Bruker MultiMode V with Nanoscope V controller), aiming at atomic-resolution frequency-modulation imaging in ambient and in liquid environment. Care was taken to maintain the AFMs original stability and ease of operation. The new system builds upon an optimized light source, a new photodiode and an entirely new amplifier. Moreover, we introduce a home-built liquid cell and sample holder as well as a temperature-stabilized isolation chamber dedicated to low-noise imaging in liquids. The success of these modifications is measured by the reduction in the deflection sensor noise density from initially 100 fm/√Hz to around 10 fm/√Hz after modification. The performance of our instrument is demonstrated by atomically resolved images of calcite taken under liquid conditions.

5.
Rev Sci Instrum ; 80(6): 063703, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19566206

RESUMO

We report on sample holders for crystals to be cleaved for the preparation of surfaces with large atomically flat terraces. The concept for mounting sample crystals is based on a vicelike clamping mechanism to securely hold the crystal in position while reducing the risk of fragmentation. Sample holders based on this concept and made of suitable materials allow preparation and cleavage of crystals in the ultrahigh vacuum at high or low temperatures. To cleave the crystal, we employ a scalpel blade mounted on a wobble stick to generate a highly localized stress field initiating the cleavage process. The sample holders are used for experiments of highest resolution scanning force microscopy, however, the concept can be transferred to any other system where cleavage faces of crystals are of interest. Exemplarily, scanning force microscopy results demonstrate that (111) cleavage faces of CaF2 crystals can be prepared with steps only a few F-Ca-F triple-layers high and atomically flat terraces extending over areas of several microm2.

6.
Rev Sci Instrum ; 79(8): 083701, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19044351

RESUMO

We report on a modification of a commercial scanning force microscope (Omicron UHV AFM/STM) operated in noncontact mode (NC-AFM) at room temperature in ultrahigh vacuum yielding a decrease in the spectral noise density from 2757 to 272 fm/Hz. The major part of the noise reduction is achieved by an exchange of the originally installed light emitting diode by a laser diode placed outside the vacuum, where the light is coupled into the ultrahigh vacuum chamber via an optical fiber. The setup is further improved by the use of preamplifiers having a bandpass characteristics tailored to the cantilever resonance frequency. The enhanced signal to noise ratio is demonstrated by a comparison of atomic resolution images on CeO(2)(111) obtained before and after the modification.

7.
J Synchrotron Radiat ; 8(Pt 2): 105-9, 2001 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-11512705

RESUMO

Experimental data are presented which demonstrate the existence of a fine structure in extended X-ray absorption spectra due to interference effects in the initial photon state (piXAFS). Interference occurs between the incident electromagnetic wave and its coherently scattered waves from neighboring atoms. Using fine platinum and tungsten powders as well as polycrystalline platinum foil, piXAFS was measured in high-precision absorption experiments at beamline X1 at HASYLAB/DESY over a wide energy range. piXAFS is observed below and above absorption-edge positions in both transmission and total-electron-yield detection. Based on experimental data it is shown that piXAFS is sensitive to geometric atomic structure. Fourier-transformed piXAFS data carry information, comparable with that of EXAFS, about the short-range-order structure of the sample. Sharp structures occur in piXAFS when a Bragg backscattering condition of the incident X-rays is fulfilled. They allow precise measurement of long-range-order structural information. Measured data are compared with simulations based on piXAFS theory. Although piXAFS structures are similarly observed in two detection techniques, the importance of scattering off the sample for the measurements needs to be investigated further. Disentangling piXAFS, multielectron photoexcitations and atomic XAFS in high-precision measurements close to absorption edges poses a challenge for future studies.

8.
J Synchrotron Radiat ; 8(Pt 2): 539-41, 2001 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-11512843

RESUMO

The thermal expansion behaviour of silver fcc has been described by an anharmonic Einstein model using EXAFS data in the temperature range between 10 and 300 K. The linear expansion coefficient of a bulk silver foil agrees well with X-ray diffraction data. In the case of silver particles embedded in a silicate glass matrix, this parameter shows an increase for particles of 3.2 nm in size by 70% whereas samples with an average size of particles of 5.1 nm show no changes compared with bulk fcc. The increase for small particles reflects the size effect as well as the influence of the surrounding matrix of glass. The results reveal a substantial influence of the distribution of particle sizes on the expansion coefficient.

9.
J Synchrotron Radiat ; 8(Pt 2): 572-4, 2001 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-11512855

RESUMO

The fluorescence EXAFS (FLEXAFS) technique has been combined with an in situ cell and on-line gas analysis. For this purpose a seven-element silicon drift detector has been used, which has high count rate capabilities and can be operated at room temperature. The potential of this technique is shown by the study of the state of copper promoter atoms in Fe-Cr based high temperature shift (HTS) catalysts. The FLEXAFS measurements revealed that Cu (0.17-1.5 wt%) is present in the metallic state under working conditions of the catalysts but easily re-oxidizes upon air exposure. The reduction behaviour of copper depends strongly on the copper concentration and the pre-treatment, i.e. if the catalysts have been calcined or used in the HTS reaction. For used catalysts, a Cu(I) phase was detected as intermediate during reduction. Its stability was especially high at low copper concentration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...