Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Can J Anaesth ; 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37833472

RESUMO

PURPOSE: Although a single-injection interscalene block provides effective early postoperative analgesia following shoulder surgery, patients may experience "rebound pain" when the block resolves. Our objective was to determine if oral hydromorphone (2 mg) given six hours after a single-injection interscalene block for arthroscopic shoulder surgery leads to a clinically significant reduction in the severity of rebound pain. METHODS: After approval from research ethics boards, we conducted a two-centre, parallel-group, double-blind, randomized, placebo-controlled superiority trial. Patients received preoperative interscalene block, general anesthesia, and either hydromorphone or placebo six hours after the block. The primary outcome was the worst pain score in the first 24 hr postoperatively, measured on an 11-point (0-10) numerical rating scale. RESULTS: A total of 73 participants were randomly assigned to either the hydromorphone or placebo group. There was no statistically significant difference in the mean (standard deviation) worst pain score within 24 hr between the hydromorphone and placebo groups (6.5 [2.4] vs 5.9 [2.3]; mean difference, 0.6; 95% confidence interval, -0.5 to 1.8). Similarly, we did not find any significant difference in the pain trajectory, opioid use, or incidence of nausea and vomiting between the groups. The mean time to worst pain was 14.6 hr, and the mean time to first rescue analgesia was 11.3 hr after interscalene block. CONCLUSION: Hydromorphone 2 mg given six hours after interscalene block did not reduce the severity of rebound pain postoperatively compared with placebo in patients undergoing arthroscopic shoulder surgery. STUDY REGISTRATION: ClinicalTrials.gov (NCT02939209); registered 19 October 2016.


RéSUMé: OBJECTIF: Bien qu'un bloc interscalénique à injection unique fournisse une analgésie postopératoire précoce efficace après une chirurgie de l'épaule, les patient·es peuvent ressentir une « douleur de rebond ¼ lorsque le bloc se résorbe. Notre objectif était de déterminer si l'hydromorphone orale (2 mg) administrée six heures après une injection unique de bloc interscalénique pour une chirurgie arthroscopique de l'épaule entraînait une réduction cliniquement significative de la gravité de la douleur de rebond. MéTHODE: Après l'approbation des comités d'éthique de la recherche, nous avons mené une étude de supériorité dans deux centres, en groupes parallèles, à double insu, randomisée et contrôlée par placebo. Les patient·es ont reçu un bloc interscalénique préopératoire, une anesthésie générale et de l'hydromorphone ou un placebo six heures après le bloc. Le critère d'évaluation principal était le pire score de douleur au cours des premières 24 heures postopératoires, mesuré sur une échelle d'évaluation numérique de 11 points (0 à 10). RéSULTATS: Au total, 73 personnes ont participé à l'étude et ont été aléatoirement assignées au groupe hydromorphone ou au groupe placebo. Il n'y avait pas de différence statistiquement significative dans le score moyen (écart type) de la pire douleur dans les 24 heures entre les groupes hydromorphone et placebo (6,5 [2,4] vs 5,9 [2,3]; différence moyenne, 0,6; intervalle de confiance à 95 %, −0,5 à 1,8). De même, nous n'avons trouvé aucune différence significative dans la trajectoire de la douleur, la consommation d'opioïdes ou l'incidence de nausées et vomissements entre les groupes. Le temps moyen jusqu'à la pire douleur était de 14,6 heures, et le temps moyen jusqu'à la première analgésie de secours était de 11,3 heures après le bloc interscalénique. CONCLUSION: L'hydromorphone 2 mg administrée six heures après le bloc interscalénique n'a pas réduit la gravité de la douleur de rebond postopératoire par rapport au placebo chez les patient·es bénéficiant d'une chirurgie arthroscopique de l'épaule. ENREGISTREMENT DE L'éTUDE: ClinicalTrials.gov (NCT02939209); enregistrée le 19 octobre 2016.

2.
J Orthop Surg Res ; 18(1): 90, 2023 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-36750893

RESUMO

BACKGROUND: Videos have been used in many settings including medical simulation. Limited information currently exists on video-based assessment in surgical training. Effective assessment tools have substantial impact on the future of training. The objectives of this study were as follows: to evaluate the inter-rater reliability of video-based assessment of orthopedic surgery residents performing open cadaveric simulation procedures and to explore the benefits and limitations of video-based assessment. METHODS: A multi-method technique was used. In the quantitative portion, four residents participated in a Surgical Objective Structured Clinical Examination in 2017 at a quaternary care training center. A single camera bird's-eye view was used to videotape the procedures. Five orthopedic surgeons evaluated the surgical videos using the Ottawa Surgical Competency Operating Room Evaluation. Interclass correlation coefficient was used to calculate inter-rater reliability. In the qualitative section, semi-structured interviews were used to explore the perceived strengths and limitations of video-based assessment. RESULTS AND DISCUSSION: The scores using video-based assessment demonstrated good inter-rater reliability (ICC = 0.832, p = 0.014) in assessing open orthopedic procedures on cadavers. Qualitatively, the strengths of video-based assessment in this study are its ability to assess global performance and/or specific skills, ability to reassess missed points during live assessment, and potential use for less common procedures. It also allows for detailed constructive feedback, flexible assessment time, anonymous assessment, multiple assessors and serves as a good coaching tool. The main limitations of video-based assessment are poor audio-video quality, and questionable feasibility for assessing readiness for practice. CONCLUSION: Video-based assessment is a potential adjunct to live assessment in orthopedic open procedures with good inter-rater reliability. Improving audio-video quality will enhance the quality of the assessment and improve the effectiveness of using this tool in surgical training.


Assuntos
Educação de Pós-Graduação em Medicina , Internato e Residência , Humanos , Educação de Pós-Graduação em Medicina/métodos , Projetos Piloto , Reprodutibilidade dos Testes , Competência Clínica , Tomada de Decisões
3.
Eur J Orthop Surg Traumatol ; 33(4): 1109-1116, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35412150

RESUMO

OBJECTIVES: To biomechanically compare the stiffness of midshaft synthetic clavicle osteotomies fixed with either superior anatomic pre-contoured locking plates, anterior anatomic pre-contoured locking plates, or short-segment dual orthogonal mini-plate fixation. DESIGN AND SETTING: Controlled laboratory study. Specimens Twenty-one synthetic pre-osteotomized clavicles were separated into three groups: superior plating, anterior plating, or dual-plating. Each clavicle was sequentially tested in non-destructive cycles of axial compression, three-point bending, and torsion. Load and displacement were recorded. Stiffness was calculated. RESULTS: No statistically significant differences were found between construct stiffness during axial compression, three-point bending, or torsional testing. One superior plated clavicle suffered catastrophic failure during axial compression. One dual mini-fragment plated clavicle suffered catastrophic failure during torsion. CONCLUSIONS: Orthogonal dual mini-fragment fixation of transverse clavicle fractures is biomechanically similar to superior and anterior pre-contoured anatomic locking plate fixation. No statistically significant differences in construct stiffness were found in axial compression, three-point bending, or torsion testing. Further clinical research is required to determine the long-term stability of dual mini-fragment plate fixation. LEVEL OF EVIDENCE: IV.


Assuntos
Clavícula , Fraturas Ósseas , Humanos , Clavícula/cirurgia , Fenômenos Biomecânicos , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas , Osteotomia , Placas Ósseas
4.
Can J Surg ; 65(3): E335-E341, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35580883

RESUMO

BACKGROUND: Recreational cannabis use was legalized in Canada in 2018. Cannabis use patterns and patient attitudes toward cannabis use, particularly in the context of these legal changes, are not well understood. Our aim was to evaluate baseline cannabis use patterns and attitudes at the time of legalization among patients with upper extremity conditions in Canada. METHODS: In 2018, we conducted a multicentre cross-sectional survey study of 1561 patients with upper extremity conditions at 7 surgical centres. Participants were asked whether they currently use cannabis. If yes, they were asked questions regarding usage patterns and perceptions of cannabis use, including likelihood of use, safety and comfort discussing it with their physician. RESULTS: In the 6 months after legalization, 790 (51%) participants felt that cannabis was safer than prescription narcotics, with 450 (29%) currently using cannabis. Reasons for cannabis use included pain (56%), stress (51%) and recreation (42%). Of the 1105 patients not using cannabis, 267 (24%) were more likely to consider it after legalization. Of the 450 cannabis users, 73 (16%) had been using it for less than 6 months, 206 (46%) stated they were more comfortable discussing cannabis with their physician after legalization and 195 (43%) were using cannabis more than 4 times per week. CONCLUSION: Many patients with upper extremity conditions were regularly using cannabis. Patients were more comfortable discussing cannabis with their physician than before legalization. Treating surgeons should be aware of these trends and expect to receive questions regarding cannabis use.


Assuntos
Cannabis , Analgésicos , Canadá/epidemiologia , Estudos Transversais , Humanos , Legislação de Medicamentos , Extremidade Superior
5.
J Orthop Trauma ; 33(4): 169-174, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30893216

RESUMO

OBJECTIVE: To determine if geriatric intertrochanteric hip fracture patients achieve equivalent postoperative functional status after management with either a short (180-200 mm) or a long (260-460 mm) InterTAN intramedullary device. DESIGN: Retrospective review of a prospective randomized control trial. SETTING: Four Level I Trauma Centers. PATIENTS/PARTICIPANTS: One hundred eight patients with OTA/AO classification 31A-1 and 31A-2 intertrochanteric hip fractures were included in the study. INTERVENTION: Internal fixation using an IT device. MAIN OUTCOMES MEASURES: Primary outcomes included Functional Independence Measure and Timed Up and Go. Secondary outcomes included blood loss, surgical time, length of stay, adverse events, and mortality. RESULTS: Seventy-one short and 37 long IT patients met study inclusion criteria. Demographics were similar between groups. There was no difference in Functional Independence Measure or Timed Up and Go scores between the 2 IT groups at any of the time points collected. Mean operative time was lower in the short IT group than in the long IT group (60 vs. 73 minutes; P = 0.021). A higher proportion of long IT patients had reamed constructs (95% vs. 48% short IT, P < 0.001). Postoperative blood loss was significantly higher in the long IT group without a significant influence on the number of patients requiring transfusion (P = 0.582) or average units transfused (P = 0.982). There was no significant difference in the proportion of postoperative adverse events between the 2 cohorts despite a higher number of peri-implant femur fractures in the short IT group than in the long IT group (5 vs. 1, P = 0.350). CONCLUSIONS: Postoperative functional status was not influenced by the length of IT device in the management of geriatric intertrochanteric hip fractures. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fixação Intramedular de Fraturas/instrumentação , Fraturas do Quadril/cirurgia , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos
6.
J Orthop Trauma ; 31(1): 1-8, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27763958

RESUMO

OBJECTIVES: To compare outcomes in elderly patients with intertrochanteric hip fractures treated with either the sliding hip screw (SHS) or InterTAN intramedullary device (IT). DESIGN: Prospective, randomized, multicenter clinical trial. SETTING: Five level 1 trauma centers. PATIENTS: Two hundred forty-nine patients 55 years of age or older with AO/OTA 31A1 (43) and OA/OTA 31A2 (206) fractures were prospectively enrolled and followed for 12 months. INTERVENTION: Computer generated randomization to either IT (n = 123) or SHS (n = 126). MAIN OUTCOME MEASUREMENTS: The Functional Independence Measure (FIM) and the Timed Up and Go test (TUG) were used to measure function and motor performance. Secondary outcome measures included femoral shortening, complications, and mortality. RESULTS: Demographics, comorbidities, preinjury FIM scores and TUG scores were similar between groups. Patients (17.2%) who received an IT had limb shortening greater than 2 cm compared with 42.9% who received an SHS (P < 0.001). To determine the importance of preinjury function and fracture stability, we analyzed the subgroup of patients with the ability to walk 150 m independently preinjury and an OA/OTA 31A-2 fracture (n = 70). In this subgroup, patients treated with SHS had greater shortening and demonstrated poorer FIM and TUG scores compared with patients treated with an IT. CONCLUSIONS: Overall, most patients with intertrochanteric femur fractures can expect similar functional results whether treated with an intramedullary or extramedullary device. However, active, functional patients have an improved outcome when the InterTAN is used to treat their unstable intertrochanteric fracture. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Parafusos Ósseos/estatística & dados numéricos , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/estatística & dados numéricos , Consolidação da Fratura , Fraturas do Quadril/mortalidade , Fraturas do Quadril/cirurgia , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Canadá/epidemiologia , Análise de Falha de Equipamento , Feminino , Avaliação Geriátrica/estatística & dados numéricos , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Prevalência , Desenho de Prótese , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
7.
J Orthop Trauma ; 19(10): 698-702, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16314717

RESUMO

OBJECTIVES: To compare the compressive strength of a bone substitute material (alpha-BSM) to cancellous bone when used to fill a defect void in a cadaver model of a Schatzker II split depression fracture of the lateral tibial plateau. DESIGN: Randomized, paired design. SETTING: Biomedical engineering laboratory. PATIENTS: Twenty-six human tibias were harvested from 13 cadavers. Three pairs of tibia fractured during preparation and were excluded. The remaining 10 matched pairs were randomized to fixation by using the bone substitute material or cancellous bone. INTERVENTION: A split depression fracture of the lateral tibial plateau was created in each tibia by using reproducible methods. This fracture was stabilized with a stainless steel L-plate and screws and either alpha-BSM or cancellous bone to fill the defect void. MAIN OUTCOME MEASUREMENTS: Stiffness of the elevated fragment in compression, total depression of the joint at 1000 N. RESULTS: The alpha-BSM bone substitute displayed significantly greater stiffness than cancellous bone constructs in Schatzker II split depression fractures of the lateral tibial plateau (P < 0.0001). Plateau defects displaced significantly less at 1000 N when using alpha-BSM in comparison to cancellous bone (P < 0.0001). CONCLUSIONS: In this cadaveric study, alpha-BSM is an effective bone substitute compared with cancellous bone graft for stabilizing split depression fractures of the lateral tibial plateau.


Assuntos
Cimentos Ósseos/uso terapêutico , Transplante Ósseo/métodos , Fosfatos de Cálcio/uso terapêutico , Fixação de Fratura/métodos , Fraturas da Tíbia/terapia , Placas Ósseas , Parafusos Ósseos , Cadáver , Força Compressiva , Humanos , Técnicas In Vitro , Resultado do Tratamento , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...