Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Cardiovasc Med ; 9: 997961, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36312248

RESUMO

Introduction: In the last two decades, a more aggressive approach has been encouraged to treat patients with acute type A aortic dissection (ATAAD), extending the repair to the aortic arch and proximal descending thoracic aorta with the frozen elephant trunk (FET) implantation. Here, we report our single-centre experience with the FET technique for the systematic treatment of emergency type A aortic dissection. Materials and methods: Between December 2017 and January 2022, 69 consecutive patients were admitted with ATAAD; of those, 66 patients (62.9 ± 10.2 years of age, 81.8% men) underwent emergency hybrid aortic arch and FET repair with the multibranched Thoraflex hybrid graft and were enrolled in the study. Primary endpoints were 30 days- and in-hospital mortality. Secondary endpoints were postoperative morbidity and follow-up survival. To better clarify the impact of age on surgical outcomes, we have divided the study population into two groups: group A for patients <70 years of age (47 patients), and group B for patients ≥70 years (19 patients). Time-to-event analysis has been conducted using the Log-rank test and is displayed with Kaplan-Meier curves. A multiple Cox proportional Hazard model was developed to identify predictors of long-term survival with a stepwise backward/forward selection process. Results: 30-days- and in-hospital mortality were 10.6 and 13.6%, respectively. Stroke occurred in three (4.5%) patients. Two (3.0%) patients experienced spinal cord ischemia. We did not find any statistically significant difference between the two groups in terms of main post-operative outcomes. The multivariable Cox proportional hazard model showed left ventricular ejection fraction (HR: 0.83, 95% CI: 0.79-0.92, p < 0.01), peripheral vascular disease (HR: 15.8, 95% CI: 3.9-62.9, p < 0.01), coronary malperfusion (HR: 0.10, 95% CI: 0.01-0.77, p =0.03), lower limbs malperfusion (HR: 5.1, 95% CI: 1.10-23.4, p = 0.04), and cardiopulmonary bypass time (HR: 1.02, 95% CI: 1-1.04, p = 0.01) as independent predictors of long term mortality. Conclusions: Frozen elephant trunk repair to treat emergency type A aortic dissection appears to be associated with good early and mid-term clinical outcomes even in the elderly.

2.
Cardiovasc Diagn Ther ; 12(4): 516-520, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36033221

RESUMO

The frozen elephant trunk (FET) technique is an increasingly common procedure to treat complex extensive aortic disease both in elective and emergency setting. In a contemporary era, several prostheses are available to be used by surgeons performing such procedures, merging the advantages of endovascular and conventional surgery and preparing a more useful landing zone for second-stage downstream endovascular or open repair. Thoraflex hybrid (Terumo Aortic, Scotland) is a largely used hybrid vascular device merging a conventional surgical vascular graft made of gelatin-sealed woven polyester graft with a nitinol self-expanding stent graft. Since its release in 2012, this prosthesis has gained a large consensus, mainly for the plexus version, which allows for single reimplantation of the epiaortic vessels. In the last few years, new devices have come out to offer new specific weapons to be used by the surgical team in different clinical scenarios. In this context, the need of making the supra-aortic vessel debranching easier and more functional to our surgical technique has pushed our demand for a customization of a conventional Thoraflex hybrid. Here we report a modification to its standard design, the concept beyond the "Custom device" and its potential advantages with regards to our peculiar implantation technique and intraoperative cerebral perfusion during circulatory arrest time.

3.
J Card Surg ; 37(1): 107-114, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34662451

RESUMO

BACKGROUND AND AIM OF THE STUDY: To report early clinical outcomes of the frozen elephant trunk (FET) technique for the treatment of complex aortic diseases after transition from conventional elephant trunk. METHODS: A single-center, retrospective study of patients who underwent hybrid aortic arch and FET repair for aortic arch and/or proximal descending aortic aneurysms, acute and chronic Stanford type A aortic dissection with arch and/or proximal descending involvement, Stanford type B acute and chronic aortic dissections with retrograde aortic arch involvement. RESULTS: Between December 2017 and May 2020, 70 consecutive patients (62.7 ± 10.6 years, 59 male) were treated: 41 (58.6%) for emergent conditions and 29 (41.4%) for elective. Technical success was 100%. In-hospital mortality was 14.2% (n = 12, 17.1% emergent vs. 10.3% elective, P = NS); 2 (2.9%) major strokes; 1 (1.4%) spinal cord injury. Mean follow-up was 12.5 months (interquartile range, 3.7-22.3). Overall survival at 3, 6, 12, and 24 months was 90% (95% confidence interval [CI], 83.2-97.3), 85.6% (95% CI, 77.7-94.3), 79.1% (95% CI, 69.9-89.5), 75.6% (95% CI, 65.8-86.9) and 73.5% (95% CI, 63.3-85.3). There were no aortic re-interventions and no distal stent graft-induced new entry (dSINE); 5 patients with residual type B dissection underwent TEVAR completion. CONCLUSIONS: In a real-world setting, FET with Thoraflex Hybrid demonstrated feasibility and good clinical outcomes, even in emergent setting. Our implant technique optimize cerebral perfusion reporting good results in terms of neurological complications. Techniques to perfect the procedure and to reduce remaining risks, and consensus on considerations such as standardized cerebral protection need to be reported.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Humanos , Masculino , Estudos Retrospectivos
4.
Medicina (Kaunas) ; 57(9)2021 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-34577818

RESUMO

Acute type A aortic dissection (ATAAD) is an indisputable emergency with very poor outcomes without surgical treatment. Although the aortic arch is often involved in the aortic dissection, its optimal management during surgical therapy remains uncertain. A conservative tear-oriented approach has traditionally been adopted, limiting the procedure to the ascending aorta (or hemiarch) replacement. However, dilation of the residual dissected aorta and subsequent rupture may occur, requiring further intervention in the future. In the last two decades, the frozen elephant trunk (FET) technique has become a valid and attractive option to treat aortic disease when the arch and the thoracic aorta are involved, both in elective and in emergency settings. Here, we report a review of the contemporary literature regarding the short- and long-term outcomes of the FET technique in ATAAD repair.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Doença Aguda , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Humanos , Estudos Retrospectivos
5.
Clin Case Rep ; 9(9): e04688, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34484752

RESUMO

Difficult diagnosis is due to rarity of the case. TT or TE echocardiography is sufficient to make a correct diagnosis. The risk of embolism or coronary ostia occlusion should guide the decision for surgery.

6.
JACC Case Rep ; 3(6): 884-887, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34317647

RESUMO

We report a unique case of a Starr-Edwards prosthesis (model 6310, cloth covered) implanted in the mitral position by Christian Barnard that was successfully explanted and replaced after 50 years, the longest period free from valve dysfunction ever reported. Reoperation also included replacement of the native aortic valve combined with tricuspid valve annuloplasty. (Level of Difficulty: Beginner.).

7.
J Card Surg ; 36(1): 371-373, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33225461

RESUMO

Reimplantation of the supra-aortic vessels can be challenging with Thoraflex Hybrid. A device modification made the vessel lengths more appropriate and the position of the neo-vessels in the chest avoided malpositioning and kinking and facilitated sternum closure; this may improve operating times as well as allowing complete and continuous cerebral trivascular perfusion and corrects positioning of the intrathoracic vessels.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Anastomose Cirúrgica , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Humanos
8.
Aorta (Stamford) ; 8(4): 111-115, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33307592

RESUMO

Type A aortic dissection, according to Stanford classification, is a surgical emergency with high morbidity and carries 56% of in-hospital mortality when surgical intervention is not performed. The surgical mortality at 30 days is 10 to 20%. The therapeutic goals are to replace the diseased ascending aorta and to treat or to monitor the distal aortic patent false lumen. When the dissection involves the aortic root and the architecture of aortic valve is normal, the surgical techniques used could be multiple: reinforce the aortic root and spare the native aortic valve or replace the aortic valve and the aortic root. The Florida sleeve technique has been developed to treat the aortic aneurysm, sparing the aortic valve in patients with connective tissue disease. Some case reports have described the use of this technique to treat an acute aortic dissection. In the following case, we present a single stage repair of the ascending aorta, aortic arch, and proximal intrathoracic aorta in a patient with Type A aortic dissection through the contemporaneous use of two techniques: Florida sleeve and Vascutek "Thoraflex" hybrid prosthesis. The use of these two techniques allows the repair/replacement of the proximal intrathoracic aorta, the sparing of the native aortic valve, the employment of a hybrid prosthesis to replace the supraortic vessels, and the creation of a descending aortic landing zone for later, distal intervention.

9.
J Card Surg ; 35(11): 3157-3159, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32720389

RESUMO

BACKGROUND: Displacement of Impella 5.0 secondary to patient movement or transportation is a well-known complication. Typically, repositioning of an Impella across the aortic valve is attempted over a guidewire. We present the first case, to our knowledge, of repositioning a dislodged Impella 5.0 without a guidewire under transesophageal echocardiography (TEE) guidance, by inducing rapid ventricular pacing to cross the aortic valve. CASE PRESENTATION: A 70-year-old man with low left ventricular ejection fraction underwent off-pump coronary artery bypass grafting. On 2nd postoperative day a low cardiac output state developed with increasing lactate levels and consequently the patient was taken to the cardiac catheterization laboratory for insertion of an Impella 5.0. Suddenly the Impella system failed with a rapid hemodynamic deterioration and it was successfully bedside repositioned inducing rapid ventricular pacing. CONCLUSIONS: In case of accidental Impella dislodgement and fast deterioration of the patient's hemodynamic status, rapid pacing may be an option to "open" the aortic valve thus aiding quick replacement of Impella 5.0 through the aortic valve into the left ventricle under TEE guidance.


Assuntos
Valva Aórtica/cirurgia , Estimulação Cardíaca Artificial/métodos , Coração Auxiliar/efeitos adversos , Falha de Prótese , Implantação de Prótese/métodos , Cirurgia Assistida por Computador/métodos , Idoso , Ponte de Artéria Coronária sem Circulação Extracorpórea , Ecocardiografia Transesofagiana , Ventrículos do Coração/cirurgia , Hemodinâmica , Humanos , Masculino , Reoperação
10.
Ann Ital Chir ; 79(2): 139-42, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18727278

RESUMO

BACKGROUND: Brunner's hamartoma is a quite rare neoformation whose origin is not completely clear. METHODS: A case of a 69-year-old man with recurrent epigastric pain and an endoscopic finding of a duodenal mass is reported. RESULTS: The complete removal of hamartoma can give a complete remission of symptoms. CONCLUSIONS: Hamartoma can be only diagnosed by endoscopy and histological exam; its therapy is always surgical, also in order to avoid possible malignant degeneration.


Assuntos
Glândulas Duodenais , Neoplasias Duodenais , Hamartoma , Idoso , Glândulas Duodenais/patologia , Neoplasias Duodenais/patologia , Neoplasias Duodenais/cirurgia , Endoscopia , Hamartoma/patologia , Hamartoma/cirurgia , Humanos , Masculino
11.
Tex Heart Inst J ; 31(2): 137-42, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15212123

RESUMO

Hypertrophic obstructive cardiomyopathy is a dynamic obstruction of the left ventricular outflow tract caused by septal hypertrophy and systolic anterior motion of the mitral valve. When the condition cannot be controlled by medical therapy the most frequently used surgical approach is left ventricular myotomy-myectomy. Mitral valve replacement (to correct another mechanism of obstruction) is another surgical option; however, its use for this condition is controversial. We review the long-term results of patients who underwent limited left ventricular myotomy-myectomy and mitral valve replacement at our institution. Eighteen patients who had hypertrophic obstructive cardiomyopathy and severe mitral insufficiency underwent surgery between 1978 and 1983: 7 were men and 11 were women (mean age, 41.8 +/- 10.5 years). Preoperatively, most of the patients (78.8%) were in New York Heart Association functional class III or IV. The operation consisted of a shallow myectomy of the hypertrophied septum and mitral valve replacement. One patient died in the hospital (5.5%); 3 patients died later during follow-up. The remaining 14 patients are alive and in good condition (mean follow-up, 21.9 +/- 1.7 years). Functional class improved postoperatively in all surviving patients. The mean left ventricular outflow tract gradient fell from 78.1 +/- 20.9 mmHg preoperatively to 9.4 +/- 5.2 mmHg postoperatively (P <0.001). At present, surgical treatment of hypertrophic obstructive cardiomyopathy does not include mitral valve replacement. However, our long-term results show that limited ventricular myectomy and mitral valve replacement predictably and consistently lower the left ventricular outflow tract gradient and resolve the mitral valve insufficiency.


Assuntos
Cardiomiopatia Hipertrófica/cirurgia , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Adulto , Cardiomiopatia Hipertrófica/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Insuficiência da Valva Mitral/mortalidade , Reoperação , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...