Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Radiol ; 88(3 Pt 1): 339-48, 2007 Mar.
Artigo em Francês | MEDLINE | ID: mdl-17457265

RESUMO

Bipulmonary and cardiopulmonary transplantations are among the most difficult to perform, with a 10-year survival rate estimated at 33%. This low rate can be attributed to thoracic complications that can be classified into three distinct groups: 1) early complications, occurring in the first 30 days after transplantation (hemothorax, diaphragmatic paralysis, reperfusion edema, hydric overloading, acute rejection); 2) late complications that occur beyond the first month (bronchiolitis obliterans syndrome, bronchic stenosis, sirolimus-induced lung disorders, initial disease recurrence); and 3) infections classed separately because of their high morbidity and mortality (thoracic wall abscess, bacterial and viral pneumonia, CMV, pneumocystosis, Aspergillus necrotizing bronchitis). Imaging is essential in screening and diagnosing these complications as part of the clinician's monitoring throughout the rest of the transplant recipient's life. In diagnosis, combined with clinical and biological data, imaging has its place in delaying the onset of these diseases.


Assuntos
Diagnóstico por Imagem , Rejeição de Enxerto/diagnóstico , Transplante de Coração-Pulmão , Pneumopatias/diagnóstico , Transplante de Pulmão , Complicações Pós-Operatórias/diagnóstico , Rejeição de Enxerto/etiologia , Humanos , Pneumopatias/etiologia , Sensibilidade e Especificidade
4.
J Radiol ; 85(10 Pt 2): 1758-63, 2004 Oct.
Artigo em Francês | MEDLINE | ID: mdl-15507829

RESUMO

Orientation and morphology of the heart and coronary vessels are the basis of cardiac imaging. Knowledge of the configuration of cardiac cavities within the thorax and of the course of coronary vessels is mandatory in order to plan and carry out magnetic resonance imaging acquisitions and computed tomographic reformations. These anatomical features are described, with focus on useful data for acquisition and interpretation of imaging studies. MR and CT images will be presented.


Assuntos
Angiografia Coronária , Vasos Coronários/anatomia & histologia , Coração/anatomia & histologia , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X
5.
J Radiol ; 80(8): 835-41, 1999 Aug.
Artigo em Francês | MEDLINE | ID: mdl-10470612

RESUMO

Visual estimation of vessel diameter is unreliable and observer-dependent. With digital angiography, software for accurate quantification of arterial diameter are available. They allow: (1) selection of equipment of appropriate size (balloons, stents, etc) during revascularization procedures, (2) objective evaluation of the results of such procedures, (3) comparison between follow-up measurements and initial measurements and (4) provide reproducible data in the case of multicenter studies. The widespread availability of digital systems has been accompanied by a dramatic increase in the number of software packages for quantification. The present article reviews some of the currently available methods for quantification, presents the advantages and pitfalls of each system, and outlines their limits.


Assuntos
Angiografia/métodos , Doenças Vasculares Periféricas/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Angiografia/instrumentação , Cateterismo/instrumentação , Diagnóstico por Imagem , Seguimentos , Humanos , Estudos Multicêntricos como Assunto , Variações Dependentes do Observador , Doenças Vasculares Periféricas/terapia , Intensificação de Imagem Radiográfica/instrumentação , Reprodutibilidade dos Testes , Software , Stents
6.
J Vasc Interv Radiol ; 10(2 Pt 1): 137-42, 1999 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10082099

RESUMO

PURPOSE: To report the frequency of caval occlusion after Vena Tech-LGM filter placement and identify related factors and their potential clinical significance. MATERIALS AND METHODS: The filter was inserted into 243 patients, 142 of whom met inclusion criteria for this prospective study. Follow-up examinations performed every 2 years included clinical evaluation, plain frontal radiography of the abdomen, duplex scanning of the inferior vena cava (IVC), and/or phlebocavography. RESULTS: A progressive decrease in IVC patency was observed, reaching 66.8% at 9 years of follow-up. Complete caval occlusion occurred in 28 patients and was significantly (P < 10(-6)) associated with retraction in 24 cases. Caval occlusion was not related to age, sex, pulmonary embolism (PE), deep venous thrombosis level, underlying conditions predisposing to a thromboembolic disease before filter insertion, the level of filter placement, use of anticoagulant therapy, and death during follow-up. PE with anticoagulation failure was a predictive factor (P = .016) of subsequent filter occlusion during follow-up as compared to all other clinical indications for filter placement. Filter patency at 9 years of follow-up was 35.2% in the PE group with anticoagulation failure and 80% for other patients (odds ratio, 2.5; 95% confidence interval 1.16-5.4). CONCLUSION: PE with anticoagulation failure was the only factor predictive of subsequent caval occlusion observed in patients after Vena Tech-LGM filter placement. Caval occlusion was also related to Vena Tech-LGM filter retraction, which usually occurred at the time of occlusion.


Assuntos
Grau de Desobstrução Vascular , Filtros de Veia Cava , Veia Cava Inferior/patologia , Trombose Venosa/etiologia , Fatores Etários , Idoso , Anticoagulantes/uso terapêutico , Intervalos de Confiança , Falha de Equipamento , Feminino , Seguimentos , Previsões , Humanos , Perna (Membro)/irrigação sanguínea , Estudos Longitudinais , Masculino , Razão de Chances , Flebografia , Modelos de Riscos Proporcionais , Estudos Prospectivos , Embolia Pulmonar/etiologia , Radiografia Abdominal , Fatores de Risco , Fatores Sexuais , Análise de Sobrevida , Falha de Tratamento , Ultrassonografia Doppler Dupla , Veia Cava Inferior/diagnóstico por imagem , Trombose Venosa/diagnóstico por imagem
7.
Rev Prat ; 47(12): 1304-7, 1997 Jun 15.
Artigo em Francês | MEDLINE | ID: mdl-9248096

RESUMO

We review the respective informations yielded to the physician bu the different techniques of medical imaging (conventional radiography, ultrasounds, and computed tomography) according to the presentation of pleural diseases. Conventional radiography is always useful for diagnosis. Ultrasound is useful to confirm and localize pleural effusion. Computed tomography contributes to precise the location of pneumothorax and pleural effusion, and the possible underlying pulmonary disorders. Computed tomography also allows to precisely characterize the different types of pleural thickening, including malignant mesothelioma.


Assuntos
Doenças Pleurais/diagnóstico , Diagnóstico por Imagem , Humanos , Derrame Pleural/diagnóstico , Neoplasias Pleurais/diagnóstico , Pneumotórax/diagnóstico , Tomografia Computadorizada por Raios X
8.
Thorax ; 52(12): 1097-8, 1997 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9516906

RESUMO

The case history is presented of a 60 year old man who developed a pericardial effusion. Chest radiography showed pleural thickening and calcification. Pericardiotomy was performed and revealed nonspecific inflammatory lesions. Occupational exposure to asbestos and exclusion of other causes led to the diagnosis of benign asbestos pericardial effusion.


Assuntos
Amianto/efeitos adversos , Doenças Profissionais/etiologia , Exposição Ocupacional/efeitos adversos , Derrame Pericárdico/etiologia , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doenças Profissionais/diagnóstico por imagem , Derrame Pericárdico/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Tomografia Computadorizada por Raios X
9.
J Radiol ; 77(11): 1135-9, 1996 Nov.
Artigo em Francês | MEDLINE | ID: mdl-9033871

RESUMO

OBJECTIVES: To evaluate the value of plain abdominal X-Ray to detect vena Tech LGM filter occlusion or patency during follow-up. METHODS: Eighty-nine patients were followed in a prospective study for 2 to 6 years after vena Tech LGM filter implantation. The control examination consisted in a clinical examination, a plain abdominal X-Ray (to measure expansion index = diameter/height of the filter and to detect migration and angulation) and a Doppler ultrasonography and/or a cavography to appreciate filter patency. RESULTS: 175 plain abdominal X-Ray, 172 Doppler ultrasonographies and 28 cavographies were done. Sensitivity and specificity of retraction to suspect a filter obstruction were respectively: 82.3% and 86.1%; if expansion index was lower or equal to 0.34 its sensitivity and specificity were 100% and 92.1%. The negative predictive values of retraction and of the association retraction-migration to exclude a filter obstruction were 85.1% and 96%. CONCLUSION: Absence of migration or retraction on plain abdominal X-Ray during the follow-up is highly predictive of filter patency. This limits the use of Doppler ultrasonography and cavography.


Assuntos
Radiografia Abdominal , Filtros de Veia Cava , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Valor Preditivo dos Testes , Estudos Prospectivos , Embolia Pulmonar/cirurgia , Reprodutibilidade dos Testes , Tromboembolia/cirurgia , Filtros de Veia Cava/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...