1.
Radiat Prot Dosimetry ; 115(1-4): 616-22, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16381794

RESUMO

The tissue equivalent composition of the Gafchromic films makes them particularly suitable for the mapping of 2D and 3D treatment fields. This paper presents the results obtained using MD-55 film for the verification of real radiotherapy treatments through proton beam irradiation of suitable phantoms at the Clatterbridge Centre for Oncology (CCO) in Bebington (UK). After exposure, the variation in optical density of the films was measured using a CCD100 Microdensitometer (source at 665 nm). Holes of calibrated diameter, made during the assembly phase of the phantom, are identified by the MIRA software, used for data analysis, and allow the rendering of the films. The surface dose distributions were obtained from the variation in optical density of each of the films making up the phantom. Their elaboration to duplicate their position within the phantom, performed by 3D-doctor software, allows the volumetric reconstruction of the dose distribution.


Assuntos
Dosimetria Fotográfica/instrumentação , Imageamento Tridimensional/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Carga Corporal (Radioterapia) , Dosimetria Fotográfica/métodos , Humanos , Imagens de Fantasmas , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Technol Health Care ; 8(2): 155-64, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10955768

RESUMO

This paper presents the results obtained using radiochromic (MD-55 GafChromic) film for the 2D and 3D dosimetric reconstruction of the dose delivered by a proton beam under the real conditions of a programme of radiotherapy treatment for ocular tumours. Standard microdensitometric measurements were used to determine the variation in film optical density (O.D.) vs dose. Calibration curves were obtained by least-square fitting of the experimental OD values using a second order polynomial. This allows conversion of O.D. to dose. With this procedure it was possible to determine the distribution of the dose delivered by the proton beam in a phantom composed of layers of GafChromic film, with high surface spatial resolution and, through sections, the complete mapping of the dose delivered to a volume subjected to irradiation, as in a course of radiotherapy treatment.


Assuntos
Dosimetria Fotográfica/instrumentação , Imagens de Fantasmas , Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Alta Energia/métodos , Neoplasias Oculares/radioterapia , Dosimetria Fotográfica/métodos , Humanos , Dosagem Radioterapêutica , Sensibilidade e Especificidade