1.
Ultrasonics ; 126: 106825, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36007292

RESUMO

In our research we present a new method of differential compression of the Golay encoded ultrasound (DCGEU) in the standard beamforming mode to visualize the slow (<1cm/s) blood mimicking fluid flow in small diameter tubes. The proposed DCGEU method is based on synthesis of several subsequent B-mode frames acquired with certain time intervals (30 ms in this study) followed by the visualization of differential beamformed radio frequency (RF) echoes, which yielded the images of the scatterers moving slowly in the vessel and suppressing the static echoes outside the vessel. In order to extract small backscattered echoes from the vessel area we took an advantage of improved sensitivity of the complementary Golay coded sequences (CGCS). The validation of the proposed DCGEU method was carried out in two stages. In the first one, we compared the flow images in small tubes with a diameter of 1 mm and 2.5 mm, reconstructed from numerically simulated acoustic data for the standard transmission of short pulses and 16-bits long CGCS signals. In the second stage of the research, the experimental data were acquired in a flow phantom with silicone tubes with an internal diameter of 1.5 mm and 4.5 mm and a fluid flow velocity of 0.9 cm/s. The experiments were carried out using preprogrammed Verasonics Vantage™ research ultrasound system equipped with ALT L12-5/50 mm MHz linear array transducer with 7.8 MHz center frequency. It was evidenced both in simulations and experiments that the DCGEU provided a good flow image along the entire length of tubing with virtually angle independent detection in comparison with the conventional short pulse interrogation.


Assuntos
Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/métodos
2.
Ultrasonics ; 115: 106434, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33878528

RESUMO

Complementary Golay coded sequences (CGCS) have several advantages over conventional short pulse transmitted signals. Specifically, CGCS allow the signal-to-noise ratio (SNR) to be increased. Moreover, due to matched filtering and compression, echoes resembling the short pulse waveform with substantially higher amplitude can be obtained. However, CGCS require two subsequent transmissions to obtain a single compressed signal. This decreases the data acquisition rate and the frame rate of ultrasound imaging by two-fold. To alleviate this problem, mutually orthogonal Golay complementary sequences (MOGCS) can be used. MOGCS allow the simultaneous transmission of two CGCS pairs to be implemented, yielding the acoustic data for two image frames in one data acquisition cycle. The main objective of this work was an experimental study of the most crucial parameters of the received acoustic signals, e.g. the signal-to-noise ratio (SNR), the side-lobes level (SLL) of the signal and the axial resolution, obtained from simultaneous transmission of two pairs of CGCS comprising a MOGCS set to demonstrate their feasibility of being used in ultrasonography. For this purpose, a simultaneous synthetic transmit aperture method (SSTA) was proposed. The SSTA is based on MOGCS transmission and simultaneous reconstruction of two image frames from a single data acquisition cycle. This doubles the image reconstruction rate in comparison with conventional CGCS signals. In this paper, the ultrasound data from a perfect reflector, commercial phantoms and in vivo measurements were analysed. Two 16-bit long CGCS pairs comprising the MOGCS set were programmed and transmitted using the Verasonics Vantage™ research ultrasound system equipped with a Philips ATL L7-4 linear array ultrasound probe. It was shown that the signal parameters and overall quality of reconstructed B-mode images did not deteriorate when using the MOGCS in comparison to the conventional CGCS and short pulse signals explored so far.


Assuntos
Aumento da Imagem/métodos , Ultrassonografia/métodos , Compressão de Dados , Humanos , Processamento de Imagem Assistida por Computador , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
3.
Ultrasonics ; 52(2): 333-42, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21999938

RESUMO

The modified synthetic transmit aperture (STA) algorithm is described. The primary goal of this work was to assess the possibility to improve the image quality achievable using synthetic aperture (SA) approach and to evaluate the performance and the clinical applicability of the modified algorithm using phantoms. The modified algorithm is based on the coherent summation of back-scattered RF echo signals with weights calculated for each point in the image and for all possible combinations of the transmit-receive pairs. The weights are calculated using the angular directivity functions of the transmit-receive elements, which are approximated by a far-field radiation pattern of a narrow strip transducer element vibrating with uniform pressure amplitude over its width. In this way, the algorithm takes into account the finite aperture of each individual element in the imaging transducer array. The performance of the approach developed was tested using FIELD II simulated synthetic aperture data of the point reflectors, which allowed the visualization (penetration) depth and lateral resolution to be estimated. Also, both simulated and measured data of cyst phantom were used for qualitative assessment of the imaging contrast improvement. The experimental data were obtained using 128 elements, 4MHz, linear transducer array of the Ultrasonix research platform. The comparison of the results obtained using the modified and conventional (unweighted) STA algorithms revealed that the modified STA exhibited an increase in the penetration depth accompanied by a minor, yet discernible upon the closer examination, degradation in lateral resolution, mainly in the proximity of the transducer aperture. Overall, however, a considerable (12dB) improvement in the image quality, particularly in the immediate vicinity of the transducer's surface was demonstrated. The modified STA method holds promise to be of clinical importance, especially in the applications where the quality of the "near-field" image, that is the image in the immediate vicinity of the scanhead is of critical importance such as for instance in skin- and breast-examinations.


Assuntos
Ultrassonografia/métodos , Algoritmos , Melhoramento Biomédico , Meios de Contraste , Microbolhas , Álcool de Polivinil
4.
Ultrasonics ; 47(1-4): 64-73, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17825338

RESUMO

In contrast to previously published papers [A. Nowicki, Z. Klimonda, M. Lewandowski, J. Litniewski, P.A. Lewin, I. Trots, Comparison of sound fields generated by different coded excitations - Experimental results, Ultrasonics 44 (1) (2006) 121-129; J. Litniewski, A. Nowicki, Z. Klimonda, M. Lewandowski, Sound fields for coded excitations in water and tissue: experimental approach, Ultrasound Med. Biol. 33 (4) (2007) 601-607], which examined the factors influencing the spatial resolution of coded complementary Golay sequences (CGS), this paper investigates the effect of ultrasound imaging transducer's fractional bandwidth on the gain of the compressed echo signal for different spectral widths of the CGS. Two different bit lengths were considered, specifically one and two cycles. Three transducers having fractional bandwidth of 25%, 58% and 80% and operating at frequencies 6, 4.4 and 6 MHz, respectively were examined (one of the 6 MHz sources was focused and made of composite material). The experimental results have shown that by increasing the code length, i.e. decreasing the bandwidth, the compressed echo amplitude could be enhanced. The smaller the bandwidth was the larger was the gain; the pulse-echo sensitivity of the echo amplitude increased by 1.88, 1.62 and 1.47, for 25%, 58% and 80% bandwidths, respectively. These results indicate that two cycles bit length excitation is more suitable for use with bandwidth limited commercially available imaging transducers. Further, the time resolution is retained for transducers with two cycles excitation providing the fractional bandwidth is lower than approximately 90%. The results of this work also show that adjusting the code length allows signal-to-noise-ratio (SNR) to be enhanced while using limited (less that 80%) bandwidth imaging transducers. Also, for such bandwidth limited transducers two cycles excitation would not decrease the time resolution, obtained with "conventional" spike excitation. Hence, CGS excitation could be successfully implemented with the existing, relatively narrow band imaging transducers without the need to use usually more expensive wideband, composite ones.


Assuntos
Compressão de Dados/métodos , Processamento de Sinais Assistido por Computador/instrumentação , Transdutores , Ultrassonografia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Ultrasonics ; 44(1): 121-9, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16313936

RESUMO

This work reports the results of measurements of spatial distributions of ultrasound fields obtained from five energizing schemes. Three different codes, namely, chirp signal and two sinusoidal sequences were investigated. The sequences were phase modulated with 13 bits Barker code and 16 bits Golay complementary codes. Moreover, two reference signals generated as two and sixteen cycle sine tone bursts were examined. Planar, 50% (fractional) bandwidth, 15 mm diameter source transducer operating at 2 MHz center frequency was used in all measurements. The experimental data were collected using computerized scanning system and recorded using wideband, PVDF membrane hydrophone (Sonora 804). The measured echoes were compressed, so the complete pressure field in the investigated location before and after compression could be compared. In addition to a priori anticipated increase in the signal to noise ratio (SNR) for the decoded pressure fields, the results indicated differences in the pressure amplitude levels, directivity patterns, and the axial distance at which the maximum pressure amplitude was recorded. It was found that the directivity patterns of non-compressed fields exhibited shapes similar to the patterns characteristic for sinusoidal excitation having relatively long time duration. In contrast, the patterns corresponding to compressed fields resembled those produced by brief, wideband pulses. This was particularly visible in the case of binary sequences. The location of the maximum pressure amplitude measured in the 2 MHz field shifted towards the source by 15 mm and 25 mm for Barker code and Golay code, respectively. The results of this work may be applicable in the development of new coded excitation schemes. They could also be helpful in optimizing the design of imaging transducers employed in ultrasound systems designed for coded excitation. Finally, they could shed additional light on the relationship between the spatial field distribution and achievable image quality and in this way facilitate optimization of the images obtained using coded systems.

6.
Ultrasonics ; 41(8): 615-21, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14585473

RESUMO

This paper describes a novel approach to estimate broadband ultrasound attenuation (BUA) in a bone structure in human in vivo using coded excitation. BUA is an accepted indicator for assessment of osteoporosis. In the tested approach a coded acoustic signal is emitted and then the received echoes are compressed into brief, high amplitude pulses making use of matched filters and correlation receivers. In this way the acoustic peak pressure amplitude probing the tissue can be markedly decreased whereas the average transmitted intensity increases proportionally to the length of the code. This paper examines the properties of three different transmission schemes, based on Barker code, chirp and Golay code. The system designed is capable of generating 16 bits complementary Golay code (CGC), linear frequency modulated (LFM) chirp and 13-bit Barker code (BC) at 0.5 and 1 MHz center frequencies. Both in vivo data acquired from healthy heel bones and in vitro data obtained from human calcaneus were examined and the comparison between the results using coded excitation and two cycles sine burst is presented. It is shown that CGC system allows the effective range of frequencies employed in the measurement of broadband acoustic energy attenuation in the trabecular bone to be doubled in comparison to the standard 0.5 MHz pulse transmission. The algorithm used to calculate the pairs of Golay sequences of the different length, which provide the temporal side-lobe cancellation is also presented. Current efforts are focused on adapting the system developed for operation in pulse-echo mode; this would allow examination and diagnosis of bones with limited access such as hip bone.


Assuntos
Calcâneo/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Acústica , Algoritmos , Humanos , Programas de Rastreamento , Ultrassonografia/métodos