Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Pharm ; 304(1-2): 63-71, 2005 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-16139970

RESUMO

Topical aciclovir cream (ACV, Zovirax Cream) containing 40% propylene glycol (PG), the optimum found for skin penetration, is clinically effective in the treatment of recurrent herpes labialis. One hundred and thirty-nine ACV generic creams were analysed and 80% of these contained less than 20% PG. From this, we hypothesised that these generics might be bioinequivalent to the innovator cream. A pilot in vitro skin permeation study compared the innovator cream with two generics containing about 15% PG. Next, 10 generics containing 0-15% PG were tested in an independent laboratory. Finally, a PG dose-ranging study was conducted in Zovirax cream base. In all studies, human skin was used and ACV analysed by LC-MS-MS. In the pilot study, the innovator cream delivered 7.5-fold more ACV than the two generics. Superiority was confirmed in the second study against all 10 ACV generic creams. By grouping the creams according to PG content, a relationship to ACV skin permeation was suggested. The PG dose effect was confirmed in the third study. These studies suggest that not all marketed ACV creams are bioequivalent to the clinically proven innovator. Given the magnitude of the differences seen, there is concern over therapeutic inequivalence of generic ACV creams to the innovator cream.


Assuntos
Aciclovir/farmacocinética , Medicamentos Genéricos/farmacocinética , Pele/metabolismo , Aciclovir/química , Cromatografia Líquida , Cultura em Câmaras de Difusão , Medicamentos Genéricos/química , Excipientes/química , Humanos , Técnicas In Vitro , Espectrometria de Massas , Pomadas , Projetos Piloto , Polietilenoglicóis/química , Pele/efeitos dos fármacos , Absorção Cutânea/efeitos dos fármacos , Equivalência Terapêutica
2.
J Pharm Sci ; 94(3): 632-8, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15666298

RESUMO

In vitro measurements of skin absorption are an increasingly important aspect of regulatory studies, product support claims, and formulation screening. However, such measurements are significantly affected by skin variability. The purpose of this study was to determine inter- and intralaboratory variation in diffusion cell measurements caused by factors other than skin. This was attained through the use of an artificial (silicone rubber) rate-limiting membrane and the provision of materials including a standard penetrant, methyl paraben (MP), and a minimally prescriptive protocol to each of the 18 participating laboratories. "Standardized" calculations of MP flux were determined from the data submitted by each laboratory by applying a predefined mathematical model. This was deemed necessary to eliminate any interlaboratory variation caused by different methods of flux calculations. Average fluxes of MP calculated and reported by each laboratory (60 +/- 27 microg cm(-2) h(-1), n = 25, range 27-101) were in agreement with the standardized calculations of MP flux (60 +/- 21 microg cm(-2) h(-1), range 19-120). The coefficient of variation between laboratories was approximately 35% and was manifest as a fourfold difference between the lowest and highest average flux values and a sixfold difference between the lowest and highest individual flux values. Intralaboratory variation was lower, averaging 10% for five individuals using the same equipment within a single laboratory. Further studies should be performed to clarify the exact components responsible for nonskin-related variability in diffusion cell measurements. It is clear that further developments of in vitro methodologies for measuring skin absorption are required.


Assuntos
Técnicas de Laboratório Clínico/normas , Variações Dependentes do Observador , Técnicas de Laboratório Clínico/estatística & dados numéricos , Difusão , Cultura em Câmaras de Difusão/métodos , Cultura em Câmaras de Difusão/normas , Cultura em Câmaras de Difusão/estatística & dados numéricos , Internacionalidade , Controle de Qualidade , Padrões de Referência , Valores de Referência , Absorção Cutânea/fisiologia
3.
Int J Pharm ; 274(1-2): 213-9, 2004 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-15072797

RESUMO

We hypothesised that the depletion of propylene glycol from topical formulations applied at clinically relevant doses (approximately mg/cm2) would limit its penetration enhancement effect. The in vitro percutaneous permeation of a model drug-loperamide hydrochloride-in formulations containing propylene glycol was therefore investigated under finite dose conditions. The flux of loperamide and propylene glycol across dermatomed human skin was measured. The first study examined the effect of topical loading of a gel containing 12% propylene glycol. The second study investigated the effect of propylene glycol content in creams containing 15 and 40%. Both studies showed a correlation between the amount of propylene glycol dosed on the skin and the amount of drug that had permeated. The substantial permeation of propylene glycol and relatively small permeation of loperamide, strongly suggests, that the time dependent permeation of the drug was due to the depletion of propylene glycol at the skin surface and not to the depletion of the drug itself. As often doses applied in in vitro skin permeation experiments do not match the intended clinical dosage-they are usually much greater-this study suggests that the penetration enhancement effect of propylene glycol can be overestimated in in vitro studies.


Assuntos
Loperamida/administração & dosagem , Propilenoglicol/administração & dosagem , Pele/efeitos dos fármacos , Administração Cutânea , Cultura em Câmaras de Difusão , Sinergismo Farmacológico , Feminino , Humanos , Loperamida/farmacocinética , Pessoa de Meia-Idade , Permeabilidade/efeitos dos fármacos , Propilenoglicol/farmacocinética , Pele/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...