1.
BMJ Open Qual ; 11(1)2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-35017175

RESUMO

A rapid response system is required in a radiotherapy department for patients experiencing a critical event when access to an emergency department is poor due to geographic location and the patient is immobilised with a fixation device. We, therefore, rebuilt the response system and tested it through onsite simulations. A multidisciplinary core group was created and onsite simulations were conducted using a Plan-Do-Study-Act cycle. We identified the important characteristics of our facility, including its distance from the emergency department; the presence of many staff with little direct contact with patients; the treatment room environment and patient fixation with radiotherapy equipment. We also examined processes in each phase of the emergency response: detecting an emergency, calling the medical emergency team (MET), MET transportation to the site and on-site response and patient transportation to the emergency department. The protocol was modified, and equipment was updated. On-site simulations were held with and without explanation of the protocol and training scenario in advance. The time for the MET to arrive at the site during a 2017 simulation prior to the present project was 7 min, whereas the time to arrive after the first simulation session was shortened to 5 min and was then shortened further to 4 min in the second session, despite no prior explanation of the situation. A multidisciplinary project for emergency response with on-site simulations was conducted at an isolated radiation facility. A carefully planned emergency response is important not only in heavy ion therapy facilities but also in other departments and facilities that do not have easy access to hospital emergency departments.


Assuntos
Treinamento por Simulação , Humanos , Transporte de Pacientes
2.
J Radiat Res ; 63(1): 122-127, 2022 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-34747483

RESUMO

According to guidelines, carbon-ion beam therapy is considered to carry a high safety risk for patients with cardiac implantable electronic devices (CIEDs), although the actual impacts remain unclear. In this study, we investigated the safety of carbon-ion beam therapy in patients with CIEDs. Patients with CIEDs who underwent carbon-ion therapy at Gunma University Heavy Ion Medical Center between June 2010 and December 2019 were identified and investigated for abnormalities in the operation of their CIEDs, such as oversensing and resetting during irradiation, and abnormalities in operation after treatment. In addition, the risk of irradiation from carbon-ion beam therapy was evaluated by model simulations. Twenty patients (22 sites) with CIEDs were identified, 19 with pacemakers and one with an implantable cardioverter-defibrillator (ICD). Treatments were completed without any problems, except for one case in which the treatment was discontinued because of worsening of the primary disease. Monte Carlo simulation indicated that the carbon beam irradiation produced neutrons at a constant and high level in the irradiation field. Nevertheless, with the distances between the CIEDs and the irradiation fields in the analyzed cases, the quantity of neutrons at the CIEDs was lower than that within the irradiation. Although carbon-ion beam therapy can be safely administered to patients with CIEDs, it is advisable to perform the therapy with sufficient preparation and backup devices because of the risks involved.


Assuntos
Desfibriladores Implantáveis , Radioterapia com Íons Pesados , Marca-Passo Artificial , Carbono/uso terapêutico , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Humanos
3.
Radiother Oncol ; 157: 85-92, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33515667

RESUMO

PURPOSE: We aimed to assess the robustness of accumulated dose distributions for inter-fractional changes in passive carbon-ion radiotherapy for pancreatic cancer. METHODS: Ninety-five daily CT image sets acquired after the treatment of eight patients with pancreatic cancer were used in this prospective study. Dose distributions with treatment beam fields were recalculated for bone matching (BM) and tumor matching (TM) positions on all daily CT images, the accumulated doses being calculated using deformable image registration methods. The prescribed dose was 55.2 Gy (relative biological effectiveness [RBE]) in 12 fractions. Dose volume parameters of V95 (%) for CTV and GTV, and D2cc (Gy(RBE)) for the stomach and duodenum were evaluated. RESULTS: The medians (range) of CTV V95 (%) were 91.9 (86.1-100.0), 80.5 (56.1-90.6), and 86.4 (72.5-96.5) for the Plan, accumulated with BM and TM, respectively; GTV values (%) were 98.0 (85.7-100.0), 93.3 (65.7-99.9), and 96.2 (84.8-100.0), respectively. There were significant differences between all combinations apart from the Plan and TM for both targets. The values of stomach D2cc (Gy(RBE)) were 36.0 (16.9-43.4), 36.7 (17.9-45.0), and 35.2 (16.8-43.5), respectively; duodenum values (Gy(RBE)) were 25.2 (21.3-40.3), 30.1 (23.3-48.6), and 28.3 (20.4-50.6), respectively. There was a significant difference between the Plan and BM for duodenum only. CONCLUSIONS: TM is recommended over BM because it can achieve higher target dose coverage than BM. Nevertheless, it is not enough in some cases. Further technical improvements are necessary to improve the target dose coverage.


Assuntos
Neoplasias Pancreáticas , Planejamento da Radioterapia Assistida por Computador , Carbono , Humanos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Estudos Prospectivos , Dosagem Radioterapêutica
4.
Front Oncol ; 10: 1264, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32850384

RESUMO

Purpose: We quantified the inter-fractional changes associated with passive carbon-ion radiotherapy using vertical and horizontal beam fields for prostate cancer. Methods: In total, 118 treatment-room computed tomography (TRCT) image sets were acquired from 10 patients. Vertical (anterior-posterior) and horizontal (left-right) fields were generated on the planning target volume identified by treatment planning CT. The dose distribution for each field was recalculated on each TRCT image set at the bone-matching position and evaluated using the dose-volume parameters for the prostate and rectum V95 values. To confirm adequate margins, we generated vertical and horizontal fields with 0-, 2-, 4-, and 6-mm isotropic margins from the prostate and recalculated the dose distributions on all TRCT image sets. Sigmoid functions were fitted to a plot of acceptable ratios (that is, when prostate V95 > 98%) vs. the isotropic margin size to identify the margin at which this ratio was achieved in 95% of patients with a vertical or horizontal field. Results: The prostate V95 values (mean ± standard deviation) were 99.89 ± 0.62% and 99.99 ± 0.00% with vertical and horizontal fields, respectively; this difference was not statistically significant (p = 0.067). The rectum V95 values were 1.93 ± 1.25 and 1.88 ± 0.96 ml with vertical and horizontal fields, respectively; the difference was not statistically significant (p = 0.432). The estimated adequate margins were 2.2 and 3.0 mm for vertical and horizontal fields, respectively. Conclusions: Although there is no significant difference, horizontal fields offer higher reproducibility for prostate dosing than vertical fields in our clinical setting, and 3.0 mm was found to be an adequate margin for inter-fractional changes.

5.
Radiother Oncol ; 144: 224-230, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32044421

RESUMO

BACKGROUND AND PURPOSE: This study aimed to assess dose distributions for stage I non-small cell lung cancer (NSCLC) with passive scattering carbon-ion radiotherapy (C-ion RT) using daily computed tomography (CT) images. MATERIALS AND METHODS: We enrolled 10 patients with stage I NSCLC and acquired a total of 40 pre-fractional CT image series under the same settings as the planning CT images. These CT images were registered with planning CT images for dose evaluation using both bone matching (BM) and tumor matching (TM). Using deformable image registration, we generated accumulated doses. Moreover, the volumetric dose parameters were compared in terms of tumor coverage and lung exposure and statistical analyses were performed. RESULTS: Overall, 25% of 40 fractional dose distributions were unacceptable with BM, compared with 2.5% with TM (P < 0.001). Using BM, three patients' accumulated dose distributions were unacceptable; however, all were satisfactory with TM (P < 0.001). No differences were observed in water-equivalent path length (WEL). The required margins in patients with poor dose distribution were 5.9 and 4.4 mm for BM and TM, respectively. CONCLUSIONS: This study establishes that CT image-based TM is robust compared with conventional BM for both daily and accumulated dose distributions. The effects of changes in WEL seem to be limited. Hence, daily CT alignment is recommended for patients with stage I NSCLC receiving C-ion RT.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Carbono , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Estudos Prospectivos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
6.
Anticancer Res ; 39(8): 4351-4356, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31366529

RESUMO

BACKGROUND/AIM: To evaluate the effectiveness of diaphragm matching (DM) for carbon-ion radiotherapy (CIRT) of pancreatic cancer patients and develop a simple method to estimate tumour position. PATIENTS AND METHODS: Treatment planning CTs from 27 pancreatic cancer patients treated with CIRT in our facility were used in this study, and 32 other CT image datasets taken on different days were used for measuring tumour and diaphragm displacements. A correction method (SI-correction) was developed using the coefficient x of the regression line formula for the displacements between the diaphragm and tumour in the superior-inferior direction. The tumour positioning errors of bone matching (BM), DM, and SI-correction were measured. RESULTS: Mean (±standard deviation) absolute errors of BM, DM, and SI-correction were 5.10±3.31, 7.48±4.04, and 4.13±2.51 mm, respectively. DM showed significant differences compared to the other correction methods. CONCLUSION: DM was subject to larger errors than BM. Our correction method improved positional errors.


Assuntos
Diafragma/diagnóstico por imagem , Radioterapia com Íons Pesados/métodos , Neoplasias Pancreáticas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Idoso , Tomografia Computadorizada de Feixe Cônico , Diafragma/efeitos da radiação , Feminino , Humanos , Masculino , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Posicionamento do Paciente , Radioterapia Guiada por Imagem , Tomografia Computadorizada por Raios X
7.
Radiother Oncol ; 137: 77-82, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31078014

RESUMO

BACKGROUND AND PURPOSE: To determine whether bone matching (BM) or marker matching (MM) is the better positioning technique for carbon ion radiotherapy (CIRT) of primary hepatocellular carcinoma (HCC), we prospectively evaluated accumulated dose distributions with respect to intra- and inter-fractional anatomical changes. MATERIALS AND METHODS: The accumulated doses in ten patients with HCC were evaluated, with the doses being calculated with respect to inter-fractional changes (InterDose) on treatment-room CT images on day 1 or day 2 of therapy (RefCT). This was accomplished by warping 3-day CT dose distributions to the RefCT through deformable registration. The accumulated doses were also calculated with respect to intra-fractional change (IntraDose) calculated by warping dose distributions for three 4DCT phases to the RefCT. Each dose was evaluated using dose-volume parameters for the clinical target volume (CTV) percentages receiving greater than 95% of the prescription dose (V95). RESULTS: The InterDose CTV V95 values (mean [range]) were BM: 98.74% (95.62-100%), MM: 99.79% (98.55-100%), and the IntraDose values were BM: 99.46% (98.10-100%), MM: 99.74% (98.91-100%). Although all cases were acceptable with either matching method, MM provided better values than BM. CONCLUSION: MM is a better positioning technique than BM for ensuring the target dose during and between fractions of CIRT. However, further analysis is required as our study included only a low number of cases.


Assuntos
Osso e Ossos/efeitos da radiação , Carcinoma Hepatocelular/radioterapia , Radioterapia com Íons Pesados/métodos , Neoplasias Hepáticas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Osso e Ossos/diagnóstico por imagem , Carcinoma Hepatocelular/diagnóstico por imagem , Feminino , Marcadores Fiduciais , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica
8.
Anticancer Res ; 39(4): 1915-1921, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30952733

RESUMO

AIM: We developed a vaginal immobilization device for external radiotherapy in gynaecological malignancies and evaluated its bowel dose-reduction effect during carbon-ion radiotherapy (CIRT) and intensity-modulated radiation therapy (IMRT) in patients with cervical cancer. PATIENTS AND METHODS: Computed tomographic images obtained with and without the device in seven patients with cervical cancer were assessed. Treatment plans for CIRT and IMRT were generated, and dose-volume parameters (V20, V25, V35, and D2cc) of the rectum, sigmoidal colon, and bladder were evaluated. RESULTS: The mean±standard deviation of the rectal volume in CIRT for V35 with and without the device were 2.1±2.1 and 13.6±4.4 ml, respectively, and those in IMRT were 2.0±2.2 and 13.7±3.8 ml, respectively; these values were significantly lower in CIRT and IMRT using this device. CONCLUSION: Using our novel vaginal immobilization device, high rectal doses were largely reduced in CIRT and IMRT.


Assuntos
Radioterapia com Íons Pesados/instrumentação , Imobilização/instrumentação , Órgãos em Risco , Lesões por Radiação/prevenção & controle , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/instrumentação , Neoplasias do Colo do Útero/radioterapia , Vagina , Adulto , Idoso , Idoso de 80 Anos ou mais , Colo/diagnóstico por imagem , Colo/efeitos da radiação , Desenho de Equipamento , Feminino , Radioterapia com Íons Pesados/efeitos adversos , Humanos , Pessoa de Meia-Idade , Órgãos em Risco/diagnóstico por imagem , Órgãos em Risco/efeitos da radiação , Doses de Radiação , Lesões por Radiação/etiologia , Radioterapia de Intensidade Modulada/efeitos adversos , Reto/diagnóstico por imagem , Reto/efeitos da radiação , Tomografia Computadorizada por Raios X , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/efeitos da radiação , Neoplasias do Colo do Útero/diagnóstico por imagem
9.
Amyloid ; 21(4): 238-45, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25139672

RESUMO

Primary progressive aphasia (PPA) is a cognitive syndrome characterized by progressive and isolated language impairments due to neurodegenerative diseases. Recently, an international group of experts published a Consensus Classification of the three PPA clinical variants (naPPA, svPPA and lvPPA). We analyzed 24 patients with PPA by cognitive functions, neuroimaging (MRI, (99 m)Tc ECD-SPECT, (11)C PiB-PET and FDG-PET) and cerebrospinal fluid (CSF) analysis (ptau-181, Aß1-42, Aß1-40 and Aß1-38), to elucidate relationships between neuroimaging studies and biochemical findings in the three PPA clinical variants. Cognitive and speech functions were measured by mini-mental state examination and standard language test of aphasia. The patients with lvPPA showed significant decreases in CSF Aß1-42 and ratios of Aß1-42/Aß1-40 and Aß1-42/Aß1-38, and significant increases in CSF ptau-181 and ratios of ptau-181/Aß1-42 and ptau-181/Aß1-38; these findings were similar to those of patients with Alzheimer's disease (AD). We observed a higher frequency of the ApoE ε4 allele in the lvPPA patients relative to the two other PPA variants. In (11)C PiB-PET of lvPPA patients, PiB positive findings were detected in cortices of frontal, temporal and parietal lobes and the posterior cingulate, where massive Aß may accumulate due to AD. Our results of AD-CSF markers including Aß1-38 and (11)C PiB-PET in the lvPPA patients demonstrate a common pathological mechanism with the occurrence of AD.


Assuntos
Doença de Alzheimer/líquido cefalorraquidiano , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Afasia Primária Progressiva/líquido cefalorraquidiano , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/genética , Afasia Primária Progressiva/diagnóstico por imagem , Afasia Primária Progressiva/genética , Apolipoproteínas E/genética , Biomarcadores/líquido cefalorraquidiano , Humanos , Testes de Linguagem , Tomografia por Emissão de Pósitrons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...