Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Japonês | MEDLINE | ID: mdl-29563395

RESUMO

It is important for high-precision radiation therapy that tracking accuracy in dynamic tumor tracking (DTT) using the gimbal X-ray head. We evaluated the tracking accuracy under various respiratory patterns differ from a correlation model [four-dimensional model (4D-model)] in real-time using a digital camera. A sheet of paper with luminous line was placed on the programmable respiratory motion table (CIRS Inc.) and operated with the laser projector. The luminous line was defined as a target and the laser was defined as a gimbal. Motion table was operated at a period of 4 s and amplitude of ±10 mm to create 4D-modeling. This movement was defined as the basic operation. To investigate the tracking accuracy, target and gimbal positions were recorded using a digital camera under amplitudes (±5-20 mm) and periods (2-8 s) and analyzed by ImageJ software (NIH). The maximum tracking errors under various period and amplitude were 1.7-0.9 mm and 0.4-1.9 mm, respectively. From the creation of 4D-modeling, it was confirmed that when the period has shortened and the amplitude has increased, tracking accuracy was reduced.


Assuntos
Neoplasias/diagnóstico por imagem , Imagens de Fantasmas , Humanos , Reprodutibilidade dos Testes
2.
Rep Pract Oncol Radiother ; 22(3): 258-263, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28479875

RESUMO

We report the characteristics of quality assurance (QA) image for Vero4DRT system with a kilo-voltage (kV) cone-beam computed tomography (CBCT) capability to perform image-guided radiation therapy (IGRT). To acquire a set of CBCT, the kV source is rotated either 215° clockwise (CW) (tube 1 from 5° to 220° and tube 2 from 275° to 130°) or counterclockwise (CCW) (tube 1 from 85° to 230° and tube 2 from 355° to 140°). Image geometry, image uniformity, high/low contrast resolutions, and contrast linearity were measured with a Catphan 504 CT phantom (The Phantom Laboratory, NY). The comparison between measured and expected distances shows an excellent agreement. The CBCT for Vero4DRT system cannot perform a full 360° rotation, which leads to a loss in uniformity for image acquisition. Separations were observed for high-contrast resolution, with eight line pairs per centimeter corresponding to a gap size of 0.063 cm. For low-contrast resolution, the seventh largest hole was visible. This hole has a 4-mm diameter with 1.0% contrast level. We should check the contrast linearity compared with known value, even though it is out of range from the manufacturer manual.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...