Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Ultrasonics ; 134: 107081, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37413819

RESUMO

The extraction process of crude oil requires addition of water, resulting in complex emulsions, in which the phases must be separated before the petrochemical processing starts. An ultrasonic cell may be used to determine in real time the water content in water-in-crude oil emulsions. The water content of emulsions can be related to parameters, such as propagation velocity, density and relative attenuation. The ultrasonic measurement cell developed here is composed of two piezoelectric transducers, two rexolite buffer rods, and a sample chamber. It is an inexpensive and robust system. The cell measures the parameters at different temperatures and flow conditions. The tests were performed using emulsions with water volume concentrations from 0% to 40%. The experimental results show that this cell is able to obtain more precise parameters, when compared to similar ultrasonic techniques. The data acquired in real time may be used to improve the emulsion separation, decreasing greenhouse gases and energy requirements.

2.
Top Magn Reson Imaging ; 32(1): 5-13, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36735623

RESUMO

PURPOSE: Previous work used phantoms to calibrate the nonlinear relationship between the gadolinium contrast concentration and the intensity of the magnetic resonance imaging signal. This work proposes a new nonlinear calibration procedure without phantoms and considers the variation of contrast agent mass minimum combined with the multiple input blood flow system. This also proposes a new single-input method with meaningful variables that is not influenced by reperfusion or noise generated by aliasing. The reperfusion in the lung is usually neglected and is not considered by the indicator dilution method. However, in cases of lung cancer, reperfusion cannot be neglected. A new multiple input method is formulated, and the contribution of the pulmonary artery and bronchial artery to lung perfusion can be considered and evaluated separately. METHODS: The calibration procedure applies the minimum variation of contrast agent mass in 3 different regions: (1) pulmonary artery, (2) left atrium, and (3) aorta. It was compared with four dimensional computerized tomography with iodine, which has a very high proportional relationship between contrast agent concentration and signal intensity. RESULTS: Nonlinear calibration was performed without phantoms, and it is in the range of phantom calibration. It successfully separated the contributions of the pulmonary and bronchial arteries. The proposed multiple input method was verified in 6 subjects with lung cancer, and perfusion from the bronchial artery, rich in oxygen, was identified as very high in the cancer region. CONCLUSIONS: Nonlinear calibration of the contrast agent without phantoms is possible. Separate contributions of the pulmonary artery and aorta can be determined.


Assuntos
Meios de Contraste , Neoplasias Pulmonares , Humanos , Calibragem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X , Neoplasias Pulmonares/diagnóstico por imagem
3.
Machines ; 10(1): 1-15, 2022. ilus, graf
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1371294

RESUMO

ABSTRACT: In patients with severe heart disease, the implantation of a ventricular assist device (VAD) may be necessary, especially in patients with an indication for heart transplantation. For this, the Institute Dante Pazzanese of Cardiology (IDPC) has developed an implantable centrifugal blood pump that will be able to help a diseased human heart to maintain physiological blood flow and pressure. This device will be used as a totally or partially implantable VAD. Therefore, performance assurance and correct specification of the VAD are important factors in achieving a safe interaction between the device and the patient's behavior or condition. Even with reliable devices, some failures may occur if the pumping control does not keep up with changes in the patient's behavior or condition. If the VAD control system has no fault tolerance and no system dynamic adaptation that occurs according to changes in the patient's cardiovascular system, a number of limitations can be observed in the results and effectiveness of these devices, especially in patients with acute comorbidities. This work proposes the application of a mechatronic approach to this class of devices based on advanced control, instrumentation, and automation techniques to define a method to develop a hierarchical supervisory control system capable of dynamically, automatically, and safely VAD control. For this methodology, concepts based on Bayesian networks (BN) were used to diagnose the patient's cardiovascular system conditions, Petri nets (PN) to generate the VAD control algorithm, and safety instrumented systems to ensure the safety of the VAD system.


Assuntos
Materiais Biocompatíveis , Coração Auxiliar , Pressão Sanguínea , Tomada de Decisões Assistida por Computador
4.
Sensors (Basel) ; 21(15)2021 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-34372323

RESUMO

This work shows the application of an ultrasonic multiple-scattering sensor for monitoring water-in-petroleum emulsions. The sensor consists of a commercial ultrasonic transducer with an array of cylindrical scatterers placed in the near field. The scatterers are thin metal bars arranged in rows in front of the transducer. The backscattering signals were analyzed by calculating the wave energy and by a cross-correlation between signal segments; they were also used to determine the propagation velocity in the emulsions. The tests performed used emulsions with water volume concentrations from 0% to 50%. The results showed that both the signal energy and propagation velocity strongly depended on the concentration of water in the emulsion. Therefore, the ultrasonic multiple-scattering sensor can be used for on-line and real-time monitoring of the water content in water-in-crude-oil emulsions.


Assuntos
Petróleo , Emulsões , Petróleo/análise , Ultrassom , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...