Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Rheum Dis ; 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39107080

RESUMO

BACKGROUND: A range of sacroiliac joint (SIJ) MRI protocols are used in clinical practice but not all were specifically designed for diagnostic ascertainment. This can be confusing and no standard diagnostic SIJ MRI protocol is currently accepted worldwide. OBJECTIVE: To develop a standardised MRI image acquisition protocol (IAP) for diagnostic ascertainment of sacroiliitis. METHODS: 13 radiologist members of Assessment of SpondyloArthritis International Society (ASAS) and the SpondyloArthritis Research and Treatment Network (SPARTAN) plus two rheumatologists participated in a consensus exercise. A draft IAP was circulated with background information and online examples. Feedback on all issues was tabulated and recirculated. The remaining points of contention were resolved and the revised IAP was presented to the entire ASAS membership. RESULTS: A minimum four-sequence IAP is recommended for diagnostic ascertainment of sacroiliitis and its differential diagnoses meeting the following requirements. Three semicoronal sequences, parallel to the dorsal cortex of the S2 vertebral body, should include sequences sensitive for detection of (1) changes in fat signal and structural damage with T1-weighting; (2) active inflammation, being T2-weighted with fat suppression; (3) bone erosion optimally depicting the bone-cartilage interface of the articular surface and (4) a semiaxial sequence sensitive for detection of inflammation. The IAP was approved at the 2022 ASAS annual meeting with 91% of the membership in favour. CONCLUSION: A standardised IAP for SIJ MRI for diagnostic ascertainment of sacroiliitis is recommended and should be composed of at least four sequences that include imaging in two planes and optimally visualise inflammation, structural damage and the bone-cartilage interface.

2.
Skeletal Radiol ; 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38238456

RESUMO

OBJECTIVE: Evaluate the microbial yield and factors predicting culture positivity for image-guided arthrocentesis of suspected septic sternoclavicular (SC) arthritis. MATERIALS AND METHODS: An electronic health record search identified image-guided SC joint aspirations for suspected septic arthritis. Data was extracted by retrospective chart review including patient demographics, procedure characteristics, pre-procedure lab testing, joint culture results, final SC joint diagnoses and any effect of positive synovial cultures on subsequent antibiotic therapy. Factors associated with positive joint fluid cultures were assessed using a Chi-squared test for categorical predictors and logistic regression for continuous predictors. RESULTS: A total of 31 SC arthrocenteses met inclusion criteria with most (81%) performed using ultrasound guidance. Synovial fluid was successfully aspirated in 19/31 (61%) of cases, and in all other cases lavage fluid was successfully obtained. Synovial cultures were positive in 9/31 (29%) of cases. A final diagnosis of septic arthritis was assigned to 20/31 cases (65%) in which 9/20 (45%) had positive synovial cultures. There was no statistically significant association between synovial culture positivity and risk factors for septic arthritis, positive blood cultures, pre-aspiration antibiotics and whether synovial fluid or lavage fluid was cultured. Serum white blood cell count (WBC) and erythrocyte sedimentation rate (ESR) demonstrated statistically significant positive correlation with positive synovial cultures. CONCLUSION: Arthrocentesis is effective for microbial speciation in SC septic arthritis, and diagnostic yield may be increased with lavage when encountering a dry tap. Normal serum WBC and ESR values indicate an extremely low likelihood of positive synovial cultures.

3.
Oper Neurosurg (Hagerstown) ; 27(2): 174-179, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38289069

RESUMO

BACKGROUND AND OBJECTIVE: Lateral femoral cutaneous nerve (LFCN) decompression and transposition are surgical treatment options for meralgia paresthetica. Identifying the LFCN during surgery may be challenging, and preoperative localization is a valuable adjunct in this case. The objective of this study was to explore a new technique using preoperative ultrasound-guided clip localization (USCL) of the LFCN. METHODS: After Institutional Review Board approval, data were collected on patients who underwent both preoperative ultrasound-guided wire localization (USWL) and USCL over the past 13 years. Skin-to-nerve time was calculated prospectively. RESULTS: Fifty-six patients were identified, 51 had USWL and 5 had USCL; the skin-to-nerve median time was 7.5 and 6 minutes, respectively. Six wires were misplaced, and this was at the beginning of utilization of the USWL technique. There were no nerve injury, infection, or bleeding complications related to either wire or clip placement. CONCLUSION: USWL or USCL is safe and time-efficient in LFCN surgeries.


Assuntos
Nervo Femoral , Neuropatia Femoral , Instrumentos Cirúrgicos , Humanos , Nervo Femoral/diagnóstico por imagem , Masculino , Feminino , Neuropatia Femoral/cirurgia , Neuropatia Femoral/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Ultrassonografia de Intervenção/métodos , Adulto , Cuidados Pré-Operatórios/métodos , Descompressão Cirúrgica/métodos , Descompressão Cirúrgica/instrumentação , Síndromes de Compressão Nervosa/cirurgia , Síndromes de Compressão Nervosa/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA