Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Vascular ; 31(5): 1035-1038, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35499109

RESUMO

OBJECTIVES: This study aims to report the technical results of below-the-elbow arterial revascularization in patients with critical hand ischemia. METHODS: We retrospectively identified upper extremity critical limb ischemia patients treated with below-the-elbow arterial intervention between 2013 and 2017. Patient demographics, comorbidities, and procedural data were reviewed and technical success was evaluated. RESULTS: Seven patients with 12 arteries that were affected by critical hand ischemia were treated. All patients had a history of end-stage renal disease. The technical success rate was 83.3%. There were no major or minor complications. The average follow-up duration was 9 months (2-26 months). One patient underwent a digital amputation at 8 months. CONCLUSION: Arterial revascularization of the below-the-elbow arteries for critical hand ischemia is safe and technically feasible.


Assuntos
Arteriopatias Oclusivas , Doenças Vasculares Periféricas , Humanos , Isquemia Crônica Crítica de Membro , Cotovelo , Estudos Retrospectivos , Resultado do Tratamento , Extremidade Superior/irrigação sanguínea , Isquemia/diagnóstico por imagem , Isquemia/cirurgia , Isquemia/etiologia , Arteriopatias Oclusivas/terapia , Fatores de Risco , Salvamento de Membro/efeitos adversos , Extremidade Inferior/irrigação sanguínea , Grau de Desobstrução Vascular
3.
J Vasc Surg Cases Innov Tech ; 5(3): 360-364, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31440714

RESUMO

Inferior vena cava filters are placed to prevent life-threatening pulmonary embolism in a selected group of patients. Significant complications are known to occur with prolonged dwell times, and rarely during initial placement. In this report, we describe two cases of inadvertent noncaval inferior vena cava filter placements, specifically in the azygous vein and right renal vein, and the complex methods used to retrieve them, which exemplify the critical importance of routine and careful placement techniques.

4.
J Am Coll Radiol ; 15(11): 1553-1557, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29606636

RESUMO

BACKGROUND: To determine recent inferior vena cava filter (IVCF) retrieval volumes and rates in the Medicare population. METHODS: The summary Medicare claims data were searched for the years 2012 to 2016 to identify the frequency of IVCF placements and retrievals. The new Healthcare Common Procedure Coding System code for filter retrieval introduced in 2012, 37193, was used to track filter retrievals. Trends in number of IVCF placements and retrievals over the study period were evaluated, both of which were further stratified by physician specialty and site of service. Aggregate and compound annual growth rates for retrievals were also computed. RESULTS: A total of 255,034 filters were placed over the study period, with the filter placement volume declining from 61,889 in 2012 to 38,095 in 2016. Filter retrievals, however, increased from 4,327 in 2012 to 8,405 in 2016. The net filter retrieval rate per annual filters placed increased from 6.9% in 2012 to 22.1% in 2016, yielding an average filter retrieval rate and compound annual growth rate of 11.6% and 18.1% respectively. Radiologists placed and retrieved the majority of filters (60.4% placed, 63.5% retrieved) compared with nonradiologists. The inpatient setting was the dominant site for filter placement compared with the outpatient setting for filter retrieval across all years and specialties. CONCLUSIONS: Since introduction of the unique Healthcare Common Procedure Coding System code for IVCF retrieval in 2012, IVCF placements in the Medicare population have been declining and net retrieval rates have risen. Radiologists continue to place and retrieve the majority of filters.


Assuntos
Remoção de Dispositivo , Medicare/economia , Padrões de Prática Médica/estatística & dados numéricos , Filtros de Veia Cava , Feminino , Humanos , Masculino , Estados Unidos
5.
Diagn Interv Radiol ; 24(1): 23-27, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29317374

RESUMO

PURPOSE: We aimed to investigate patients with lower gastrointestinal bleeding who presented to the emergency department requiring initial conventional angiography. We report risk-stratified and mesenteric conventional angiography outcomes. METHODS: We retrospectively reviewed patients with lower gastrointestinal bleeding between 2001 and 2012. We included all consecutive patients with clinical lower gastrointestinal bleeding with a requirement of further angiography and possible embolization. Patients who had prior interventions or surgery were excluded. RESULTS: A total of 88 patients (35 women, 53 men) with a median age of 71 years (range, 23-99 years) were included in the analysis. Conventional angiography was positive and endovascular treatment was intended in 35 patients. Once the source of bleeding was found angiographically, endovascular treatment had a technical success rate of 90.3% and clinical success rate of 71.4%. Overall early rebleeding rate (<30 days) was 14.8% and late rebleeding rate (>30 days) was 13.6%. CONCLUSION: Identifying the source of lower gastrointestinal bleeding remains to be a clinical and angiographic challenge. Although we did not observe an association between mortality and clinical success, increased early rebleeding rates were associated with higher mortality rates.


Assuntos
Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/terapia , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Feminino , Humanos , Masculino , Mesentério/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
7.
Diagn Interv Radiol ; 23(5): 379-380, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28724508

RESUMO

Lymphatic leak is a well-documented complication following neck dissection surgeries. When conservative methods fail to control the leak, thoracic duct embolization becomes an option. Transabdominal access is the standard for this procedure; however, it is not always feasible. We discuss a technique of selective lymphatic vessel embolization utilizing retrograde transvenous access.


Assuntos
Embolização Terapêutica/métodos , Doenças Linfáticas/terapia , Esvaziamento Cervical/efeitos adversos , Complicações Pós-Operatórias/terapia , Ducto Torácico/fisiopatologia , Feminino , Humanos , Doenças Linfáticas/diagnóstico por imagem , Linfografia , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Ducto Torácico/diagnóstico por imagem , Resultado do Tratamento
9.
Cardiovasc Intervent Radiol ; 40(5): 704-711, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28078375

RESUMO

PURPOSE: To report hepatic arterial-related complications encountered during planning and treatment angiograms for radioembolization and understand any potential-associated risk factors. MATERIALS AND METHODS: 518 mapping or treatment angiograms for 180 patients with primary or metastatic disease to the liver treated by Yttrium-90 radioembolization between 2/2010 and 12/2015 were retrospectively reviewed. Intra-procedural complications were recorded per SIR guidelines. Patient demographics, indication for treatment, prior exposure to chemotherapeutic agents, operator experience, and disease burden were reviewed. Technical variables including type of radioembolic (glass vs. resin microspheres), indication for angiography (mapping vs. treatment), variant anatomy, and attempts at coil embolization were also assessed. RESULTS: Thirteen (13/518, 2.5%) arterial-related complications occurred in 13 patients. All but two complications resulted during transcatheter coil embolization to prevent non-target embolization. Complications included coil migration (n = 6), arterial dissection (n = 2), focal vessel perforation (n = 2), arterial thrombus (n = 2), and vasospasm prohibiting further arterial sub-selection (n = 1). Transarterial coiling was identified as a significant risk factor of complications on both univariate and multivariate regression analysis (odds ratio 7.8, P = 0.004). Usage of resin microspheres was also a significant risk factor (odds ratio 9.5, P = 0.042). No other technical parameters or pre-procedural variables were significant after adjusting for confounding on multivariate analysis (P > 0.05). CONCLUSION: Intra-procedural hepatic arterial complications encountered during radioembolization were infrequent but occurred mainly during coil embolization to prevent non-target delivery to extra-hepatic arteries.


Assuntos
Angiografia/métodos , Embolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Radioisótopos de Ítrio/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Microesferas , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
13.
Eur Radiol ; 22(6): 1372-84, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22302502

RESUMO

OBJECTIVE: To report the outcomes associated with endovascular therapy for patients with chronic mesenteric ischemia (CMI). METHODS: A retrospective review of patients who underwent endovascular therapy for CMI between April 1981 and September 2009 at a single institution was performed. Procedural details, mesenteric arteries treated, technical and clinical success rates, outcomes per patient and per vessel were assessed. RESULTS: In 166 patients treatment was attempted using a variety of balloon and stent platforms during the 28-year period. The technical success rate was 97% per patient and 94% per vessel. The technical success rate of stenting (99.4%) was higher than for percutaneous transluminal angioplasty (PTA; 86%; P = 0.0001). Immediate clinical improvement was seen in 146 out of 166 (88.2%). The type of guidewire or device platform, brachial vs. femoral artery access, balloon and/or stent diameters used, and stenosis vs. occlusion had no statistical impact on mortality or the primary patency of any mesenteric artery outcomes. The outcome of the superior mesenteric artery (SMA) with PTA appears to be superior to that of stenting (P = 0.014). CONCLUSION: Technical success rates are improved with the use of stents; however, PTA use in the SMA seems to offer better primary patency rates. KEY POINTS: • Superior mesenteric artery (SMA) stenosis is often responsible for ischaemic symptoms. • Treatment with percutaneous transluminal angioplasty (PTA) seems superior to stenting • Although technical success rates are improved with the use of stents. • Higher mortality in the elderly and those presenting with nausea/vomiting/bloody stools.


Assuntos
Procedimentos Endovasculares/mortalidade , Isquemia/mortalidade , Isquemia/cirurgia , Mesentério/irrigação sanguínea , Doenças Peritoneais/mortalidade , Doenças Peritoneais/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Feminino , Humanos , Isquemia/diagnóstico por imagem , Masculino , Mesentério/diagnóstico por imagem , Mesentério/cirurgia , Pessoa de Meia-Idade , Doenças Peritoneais/diagnóstico por imagem , Prevalência , Radiografia , Medição de Risco , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento , Virginia/epidemiologia
14.
Semin Intervent Radiol ; 29(1): 57-63, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23449290

RESUMO

Inferior vena cava (IVC) filter thrombosis is a complex problem. Thrombus within an IVC filter may range from an asymptomatic small thrombus to critical IVC occlusion that affects both lower extremities. The published experience of IVC thrombosis management in relation to filters is either anecdotal or limited to a small group of patients; however, endovascular treatment methods appear to be safe and effective in patients with IVC thrombosis. This review focuses on filter-related IVC thrombosis and its endovascular management.

15.
Cardiovasc Intervent Radiol ; 35(6): 1340-5, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22170507

RESUMO

PURPOSE: Our purpose was to evaluate iatrogenic renal pseudoaneurysms, endovascular treatment, and outcomes. METHODS: This retrospective study (2003-2011) reported the technical and clinical outcomes of endovascular therapy for renal pseudoaneurysms in eight patients (mean age, 46 (range 24-68) years). Renal parenchymal loss evaluation was based on digital subtraction angiography and computed tomography. RESULTS: We identified eight iatrogenic renal pseudoaneurysm patients with symptoms of hematuria, pain, and hematoma after renal biopsy (n = 3), surgery (n = 3), percutaneous nephrolithotomy (n = 1), and endoscopic shock-wave lithotripsy (n = 1). In six patients, the pseudoaneurysms were small-sized (<20 mm) and peripherally located and were treated solely with coil embolization (n = 5). In one patient, coil embolization was preceded by embolization with 500-700 micron embospheres to control active bleeding. The remaining two patients had large-sized (≥50 mm), centrally located renal pseudoaneurysms treated with thrombin ± coils. Technical success with immediate bleeding cessation was achieved in all patients. There were no procedure-related deaths or complications (mean follow-up, 23.5 (range, 1-67) months). CONCLUSIONS: Treatment of renal pseudoaneurysms using endovascular approach is a relatively safe and viable option regardless of location (central or peripheral) and size of the lesions with minimal renal parenchymal sacrifice.


Assuntos
Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Embolização Terapêutica/métodos , Doença Iatrogênica , Artéria Renal/lesões , Adulto , Idoso , Angiografia Digital , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
16.
Cardiovasc Intervent Radiol ; 33(4): 732-8, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19727940

RESUMO

We report our experience with Günter Tulip filter placement indications, retrievals, and procedural problems, with emphasis on alternative retrieval techniques. We have identified 92 consecutive patients in whom a Günter Tulip filter was placed and filter removal attempted. We recorded patient demographic information, filter placement and retrieval indications, procedures, standard and nonstandard filter retrieval techniques, complications, and clinical outcomes. The mean time to retrieval for those who experienced filter strut penetration was statistically significant [F(1,90) = 8.55, p = 0.004]. Filter strut(s) IVC penetration and successful retrieval were found to be statistically significant (p = 0.043). The filter hook-IVC relationship correlated with successful retrieval. A modified guidewire loop technique was applied in 8 of 10 cases where the hook appeared to penetrate the IVC wall and could not be engaged with a loop snare catheter, providing additional technical success in 6 of 8 (75%). Therefore, the total filter retrieval success increased from 88 to 95%. In conclusion, the Günter Tulip filter has high successful retrieval rates with low rates of complication. Additional maneuvers such as a guidewire loop method can be used to improve retrieval success rates when the filter hook is endothelialized.


Assuntos
Remoção de Dispositivo , Filtros de Veia Cava , Veia Cava Inferior/diagnóstico por imagem , Adulto , Idoso , Análise de Variância , Feminino , Veia Femoral , Fluoroscopia/métodos , Seguimentos , Humanos , Veias Jugulares , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo
17.
Clin Anat ; 22(2): 236-42, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19172661

RESUMO

The purpose of this study was to determine renal arterial anatomy and gender differences in adults without renovascular disease using multidetector computed tomography angiography (MDCTA). MDCTA datasets of 399 patients were retrospectively reviewed. Measurements of the aortorenal diameters, the angulation of the renal ostia and pedicles as well as the distance between the origins of the renal arteries were measured. Differences in measurements between genders were tested for statistical significance using analysis of variance (ANOVA) and Pearson's Chi-Square tests. A total of 798 renal arteries were available for analysis in 207 female (mean age = 52.91 years) and 192 male patients (mean age = 53.04 years). Female patients were found to have smaller aortae (at the level of the right renal ostium) and bilateral renal arteries than males (mean aortic diameter M/F = 18.33/15.89 mm, mean right renal artery ostial diameter M/F = 5.06/4.59 mm, mean left ostial renal diameter M/F = 5.14/4.66 mm) (p < .001). There was no statistical significance for the renal ostia level in relation to the vertebrae and the majority of renal arteries originated at the L1 and L2 levels. The longitudinal distance between right and left renal artery ostia ranged from 0 to 32 mm (mean = 4,6 mm, median = 5mm). The mean anteroposterior orientation of the right renal ostia was M/F = 29.45 degrees/28.20 degrees , and M/F = -7.96 degrees/-11.14 degrees for left renal artery ostia. The mean anteroposterior orientation of the right renal pedicle was M/F = 41.37 degrees/44.34 degrees and M/F = 42.31 degrees/43.95 degrees for the left pedicle. There are some differences in normal renal arterial anatomy between genders. Normal renal arterial information is useful not only for planning and performing of endovascular and laparoscopic urologic procedures, but also for medical device development.


Assuntos
Angiografia/métodos , Artéria Renal/anatomia & histologia , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/anatomia & histologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais , Adulto Jovem
18.
Diagn Interv Radiol ; 14(1): 57-60, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18306147

RESUMO

Pseudocyst development is a common complication of chronic pancreatitis. Endoscopic cystogastrostomy is an alternative to percutaneous drainage of pancreatic pseudocysts. Endoscopic ultrasound (EUS) guidance is thought to decrease the procedural risk by identifying and avoiding intervening vasculature. With EUS guidance, extreme care should be exercised to identify large gastric vessels in the path of the puncture. Preoperative imaging should be closely scrutinized for the presence of these vessels. In cases of hemorrhage, balloon tamponading is a rapid way to provide temporary control, allowing transfer of the patient for angiographic embolization. We present a case of arterial hemorrhage due to inadvertent puncture of a hypertrophied right gastric artery following EUS-guided cystogastrostomy, which was successfully treated with temporary balloon occlusion and coil embolization.


Assuntos
Hemorragia Gastrointestinal/diagnóstico , Gastrostomia/efeitos adversos , Pseudocisto Pancreático/cirurgia , Diagnóstico Diferencial , Embolização Terapêutica , Endoscopia/efeitos adversos , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Pseudocisto Pancreático/diagnóstico por imagem , Pseudocisto Pancreático/patologia , Complicações Pós-Operatórias , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção/efeitos adversos
19.
Semin Intervent Radiol ; 24(3): 279-87, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21326469

RESUMO

Aortic endograft placement is evolving into the standard of care for treatment of patients with anatomically suitable thoracic aortic aneurysms. Application of this technique and these devices in other thoracic aortic pathology, such as traumatic pseudoaneurysms, symptomatic type B aortic dissections, penetrating ulcers, and even mycotic aneurysms, appears to be promising. We report a case in which a stent graft was used to treat a post-traumatic pseudoaneurysm of the thoracic aorta. The case was complicated by delayed collapse of the endograft, which led to hypoperfusion of the extremities, kidneys, and intestines. Reestablishment of endograft patency and distal reperfusion was achieved by placement of two balloon-expandable stents within the endograft. Potential factors leading to the development of this complication are discussed.

20.
Semin Intervent Radiol ; 24(3): 288-95, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21326470

RESUMO

Mechanical thrombectomy devices are increasingly being used in selected patients with acute venous thromboembolic disease to rapidly decrease thrombus burden and establish venous patency. Hemolysis and hemoglobinuria secondary to red blood cell fragmentation is known to occur after the use of these devices. In this article we describe a case in which a 16-year-old female patient developed acute renal failure after use of a mechanical thrombectomy device for treatment of symptomatic iliocaval venous thrombosis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...