Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Exp Optom ; 106(7): 769-776, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36375141

RESUMO

CLINICAL RELEVANCE: Horizontal fusional reserves are used in the diagnosis and monitoring of common vergence disorders, such as convergence insufficiency, which can cause asthenopia and impact near work. Infrared eyetracking technology shows promise for obtaining automated and objective measurements of fusional reserves, expanding options for screening, clinical testing, and at-home monitoring/vision training. BACKGROUND: Current clinical tests for fusional reserves rely on subjective judgements made by patients (for diplopia) and clinicians (for eye movements). This paper describes an objective and automated "digital fusion-range test" pilot-tested in adults without current eye disease or binocular vision anomalies. This test combines a consumer-grade infrared eyetracker, a dichoptic display, and custom analyses programs to measure convergence and divergence reserves. METHODS: Twenty-nine adult participants completed the study. Horizontal fusional reserves at 55 cm were measured using prism bars and with our computer-based digital fusion-range test. For the digital test, observers viewed dichoptic targets whose binocular disparity modulated over time (at speeds of 0.5, 1.0, or 2.0 Δ/s) while their eye movements were continuously recorded. Subjective reports of break and recovery (by keyboard button press) were compared to objective estimates extracted from eyetracking recordings (via automated analyses). RESULTS: Objective and subjective measures of break and recovery agreed closely. Clinically small (0.3-2Δ) but statistically significant (p < 0.012) differences were found between measurement types for divergence breaks/recoveries and convergence recoveries. No significant differences were found for convergence breaks (p = 0.11). Such differences are consistent with an average 0.91 (SD 1.66) seconds delay between objective break/recovery and subjective responses. The digital test produced comparable results to the standard clinical prism bar method. CONCLUSION: The digital fusion-range test supports an automated, reliable assessment of horizontal fusional reserves, which do not depend on subjective responses. This technology may prove useful in a variety of clinical and community-based settings.


Assuntos
Tecnologia de Rastreamento Ocular , Transtornos da Motilidade Ocular , Adulto , Humanos , Convergência Ocular , Transtornos da Motilidade Ocular/diagnóstico , Visão Binocular/fisiologia , Testes Visuais
2.
Clin Exp Optom ; 105(7): 680-686, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35021960

RESUMO

Traumatic brain injury (TBI) refers to the alteration of typical brain function that occurs following a blow to the head. Even a mild case of traumatic brain injury (mTBI) can lead to long-term impairment, so accurate and timely detection is vital. Visual symptoms are common following mTBI, so while it may seem to fall outside their typical scope of practice, optometrists are ideally qualified to assess the visual impacts and help with the diagnosis of mTBI. Given that mTBI is challenging to objectively diagnose and has no universally accepted diagnostic criteria, clinicians can lack confidence in diagnosing mTBI, and be hesitant in becoming involved in the management of such patients. The development of easily quantifiable techniques using eye tracking as an objective diagnostic tool provides practitioners with an easier pathway into the field, assigning numerical values to parameters which are difficult to assess using conventional optometric tests. As this evolving technology becomes increasingly integrated into optometric clinical settings, the potential for it to identify deficits accurately and reliably in patients following mTBI, and to monitor both their recovery and the effectiveness of potential treatments will increase. This paper provides an overview of clinical tests, relevant to optometrists, that can uncover oculomotor, attentional, and exteroceptive deficits following a mTBI, so that an optometrist with an interest in eye tracking can play a role in the detection and monitoring of mTBI symptoms.


Assuntos
Concussão Encefálica , Concussão Encefálica/diagnóstico , Movimentos Oculares , Tecnologia de Rastreamento Ocular , Humanos
3.
Cont Lens Anterior Eye ; 45(5): 101541, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34840070

RESUMO

PURPOSE: Extended screen time amongst youth is a pervasive global phenomenon, with wide-ranging implications for health and quality of life. Dry eye disease is increasingly reported as emerging in paediatric populations and is associated with modified blinking behaviour during extended screen time. This study sought to evaluate spontaneous blink rates, dry eye symptomology and screen use habits of young extended screen time users. METHODS: Attendees of a gaming convention in Auckland, NZ, completed a self-directed iPad-based survey on personal screen use habits and ocular symptoms using the 5-item Dry Eye Questionnaire (DEQ-5) and the Symptom Assessment in Dry Eye (SANDE) questionnaire. Blink rate was covertly and concomitantly recorded using the front-facing iPad camera and quantified by automated software. A validated, self-assessment blink test was administered as a proxy for tear film stability measurements. RESULTS: A total of 456 respondents (mean age ± SD: 24 ± 10 years, range: 13 - 75, 38% female) reported an average weekly screen time of 43.7 ± 24.4 h. DEQ-5 and SANDE scores were 10 ± 3 and 34 ± 19; 90% of respondents qualified as symptomatic for dry eye disease (DEQ-5 ≥ 6). Blink test results suggested a tear film stability < 10 s in 24% of cases. Poorer symptomology correlated with increased screen use, elevated blink rates and reduced proxy tear film stability (r = 0.15 to 0.22, all p < 0.01). CONCLUSION: Extended screen time in a young population was associated with blinking behaviour and symptomology consistent with patients with dry eye. Implementing routine clinical screening, educational interventions, and developing official guidance on safe screen use may help prevent an accelerated degradation of ocular surface health and quality of life in young people.


Assuntos
Síndromes do Olho Seco , Adolescente , Piscadela , Criança , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/metabolismo , Feminino , Humanos , Masculino , Qualidade de Vida , Tempo de Tela , Lágrimas/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...