Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Appl Bacteriol ; 74(4): 421-7, 1993 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8486550

RESUMO

An enzyme-linked immunosorbent assay (ELISA) and a microwell fluorescent antibody (FA) direct count method have been developed for the monitoring of salmonellas in soil. Both methods have a minimum detection level of ca 10(6) cells per gram of soil. The FA direct count method gave a linear recovery for the inoculum range 10(6)-10(9) cells per gram of soil. When monitored by plate counts the survival of salmonellas was greater in a sterile than in a non-sterile soil. Evidence was found for the production of viable but non-culturable salmonellas in non-sterile soil; plate counts dropped rapidly with time, but FA direct counts and ELISA remained level. The salmonella cells became progressively smaller and rounder with time. Dead salmonella cells introduced into soil rapidly disappeared.


Assuntos
Salmonella/isolamento & purificação , Microbiologia do Solo , Contagem de Colônia Microbiana/métodos , Contagem de Colônia Microbiana/estatística & dados numéricos , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/estatística & dados numéricos , Estudos de Avaliação como Assunto , Imunofluorescência/estatística & dados numéricos , Salmonella/citologia , Salmonella/crescimento & desenvolvimento , Sensibilidade e Especificidade , Esgotos
2.
J Appl Bacteriol ; 74(2): 181-90, 1993 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8444648

RESUMO

A method that uses a cation-exchange resin (Chelex 100) and differential centrifugation for the extraction and detection of salmonellas in soil was developed. The extraction efficiencies of a range of materials were examined and Chelex plus polyethylene glycol was identified as the best combination. Shake speeds, shake times and differential centrifugation speeds were selected to give an optimum salmonella recovery. The Chelex method accurately enumerated 1 cell per 10 g of nonsterile soil within 24 h. Addition of glycerol to soil samples enabled storage at -70 degrees C for 85 d without significant decreases in salmonella numbers. The Oxoid Salmonella Rapid Test (SRT) could be used to pre-screen large numbers of soil samples for the presence of salmonellas, prior to analysis by the Chelex method. The SRT method detected Salmonella typhimurium at levels as low as 2.5 cells per 10 g of nonsterile soil.


Assuntos
Cromatografia por Troca Iônica/métodos , Salmonella typhimurium/isolamento & purificação , Salmonella/isolamento & purificação , Microbiologia do Solo , Centrifugação , Contagem de Colônia Microbiana , Criopreservação , Congelamento , Salmonella/crescimento & desenvolvimento , Salmonella typhimurium/crescimento & desenvolvimento , Sensibilidade e Especificidade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA