Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Hip Int ; 30(1_suppl): 26-33, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32907420

RESUMO

BACKGROUND: The goals of intertrochanteric hip fracture (IHF) treatment are stable fixation, early mobilisation and function restoration. If the attempt to reduce, stabilise and fracture healing utilising a femoral cephalomedullar nail (CMN) fails, options for subsequent attempts are limited. PURPOSE: Evaluate the clinical and radiographic outcomes of conversion total hip arthroplasty (THA) using a modular stem following a CMN failure. MATERIALS AND METHODS: We retrospectively reviewed a consecutive series of patients with an IHF between 2012 and 2014 to identify CMN patients that went on to the subsequent failure and conversion to THA utilising a modular femoral stem (MFS). In all cases, MP Reconstruction Prosthesis (Waldemar Link, Hamburg, Germany) was implanted. Primary clinical outcomes were assessed using Harris Hip Score (HSS) before conversion procedure, 3 months, 6 months and recent office visit post-conversion THA thereafter. The secondary outcome was to analyse intra and postoperative complications. Serial radiographs at each follow-up interval were assessed for clinical success or to confirm adverse events. RESULTS: 28 patients were included in the study; 17 were females. The average age was 72.7 years (SD ± 10.5); the average time from the index procedure to conversion THA was 12.6 months (SD ± 3.5). At baseline, average HHS was 42.1 (SD ± 3.6), improved to 80.7 (SD ± 5.1) at 3 months, 86.0 (SD ± 3.9) at 6-months which levelled off to 86.1 (SD ± 4.0) at final follow-up. There were 4 (14%) post-conversion complications: 2 dislocations, 1 superficial wound infection, 1 patient with symptomatic abductor deficiency. All 4 cases were conservatively treated successfully, the implants were retained, and the patients progressed without further issue. CONCLUSIONS: MFSs allow to successfully treat failed CMN and adverse variations in femoral anatomy with a device that will permit simultaneous correction of leg length, offset and version to relieve pain, restore function and create a durable prosthetic to host composite.


Assuntos
Artroplastia de Quadril/efeitos adversos , Fêmur/cirurgia , Fixação de Fratura/métodos , Fraturas do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/diagnóstico por imagem , Fraturas do Quadril/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Radiografia , Reoperação , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA