Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38703164

RESUMO

BACKGROUND: In patients with persistent atrial fibrillation (PerAF), antiarrhythmic drugs (AADs) are considered a first-line rhythm-control strategy, whereas catheter ablation is a reasonable alternative. OBJECTIVES: This study sought to examine the prevalence, patient characteristics, and clinical outcomes of patients with PerAF who underwent catheter ablation as a first or second-line strategy. METHODS: This multicenter observational study included consecutive patients with PerAF who underwent first-time ablation between January 2020 and September 2021 in 9 medical centers in the United States. Patients were divided into those who underwent ablation as first-line therapy and those who had ablation as second-line therapy. Patient characteristics and clinical outcomes were compared between the groups. RESULTS: A total of 2,083 patients underwent first-time ablation for PerAF. Of these, 1,086 (52%) underwent ablation as a first-line rhythm-control treatment. Compared with patients treated with AADs as first-line therapy, these patients were predominantly male (72.6% vs 68.1%; P = 0.03), with a lower frequency of hypertension (64.0% vs 73.4%; P < 0.001) and heart failure (19.1% vs 30.5%; P < 0.001). During a mean follow-up of 325.9 ± 81.6 days, arrhythmia-free survival was similar between the groups (HR: 1.13; 95% CI: 0.92-1.41); however, patients in the second-line ablation strategy were more likely to continue receiving AAD therapy (41.5% vs 15.9%; P < 0.001). CONCLUSIONS: A first-line ablation strategy for PerAF is prevalent in the United States, particularly in men with fewer comorbidities. More data are needed to identify patients with PerAF who derive benefit from an early intervention strategy.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38499825

RESUMO

BACKGROUND: Cardioneuroablation has been emerging as a potential treatment alternative in appropriately selected patients with cardioinhibitory vasovagal syncope (VVS) and functional AV block (AVB). However the majority of available evidence has been derived from retrospective cohort studies performed by experienced operators. METHODS: The Cardioneuroablation for the Management of Patients with Recurrent Vasovagal Syncope and Symptomatic Bradyarrhythmias (CNA-FWRD) Registry is a multicenter prospective registry with cross-over design evaluating acute and long-term outcomes of VVS and AVB patients treated by conservative therapy and CNA. RESULTS: The study is a prospective observational registry with cross-over design for analysis of outcomes between a control group (i.e., behavioral and medical therapy only) and intervention group (Cardioneuroablation). Primary and secondary outcomes will only be assessed after enrollment in the registry. The follow-up period will be 3 years after enrollment. CONCLUSIONS: There remains a lack of prospective multicentered data for long-term outcomes comparing conservative therapy to radiofrequency CNA procedures particularly for key outcomes including recurrence of syncope, AV block, durable impact of disruption of the autonomic nervous system, and long-term complications after CNA. The CNA-FWRD registry has the potential to help fill this information gap.

5.
Catheter Cardiovasc Interv ; 102(7): 1357-1363, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37735946

RESUMO

OBJECTIVES: We sought to produce a simple scoring system that can be applied at clinical visits before transcatheter aortic valve replacement (TAVR) to stratify the risk of permanent pacemaker (PPM) after the procedure. BACKGROUND: Atrioventricular block is a known complication of TAVR. Current models for predicting the risk of PPM after TAVR are not designed to be applied clinically to assist with preprocedural planning. METHODS: Patients undergoing TAVR at the University of Colorado were split into a training cohort for the development of a predictive model, and a testing cohort for model validation. Stepwise and binary logistic regressions were performed on the training cohort to produce a predictive model. Beta coefficients from the binary logistic regression were used to create a simple scoring system for predicting the need for PPM implantation. Scores were then applied to the validation cohort to assess predictive accuracy. RESULTS: Patients undergoing TAVR from 2013 to 2019 were analyzed: with 483 included in the training cohort and 123 included in the validation cohort. The need for a pacemaker was associated with five preprocedure variables in the training cohort: PR interval > 200 ms, Right bundle branch block, valve-In-valve procedure, prior Myocardial infarction, and self-Expandable valve. The PRIME score was developed using these clinical features, and was highly accurate for predicting PPM in both the training and model validation cohorts (area under the curve 0.804 and 0.830 in the model training and validation cohorts, respectively). CONCLUSIONS: The PRIME score is a simple and accurate preprocedural tool for predicting the need for PPM implantation after TAVR.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estimulação Cardíaca Artificial , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Estudos Retrospectivos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
6.
Ann Noninvasive Electrocardiol ; 28(5): e13073, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37515396

RESUMO

BACKGROUND: The use of a Left Ventricular Assist Device (LVAD) in patients with advanced heart failure refractory to optimal medical management has progressed steadily over the past two decades. Data have demonstrated reduced LVAD efficacy, worse clinical outcome, and higher mortality for patients who experience significant ventricular tachyarrhythmia (VTA). We hypothesize that a novel prophylactic intra-operative VTA ablation protocol at the time of LVAD implantation may reduce the recurrent VTA and adverse events postimplant. METHODS: We designed a prospective, multicenter, open-label, randomized-controlled clinical trial enrolling 100 patients who are LVAD candidates with a history of VTA in the previous 5 years. Enrolled patients will be randomized in a 1:1 fashion to intra-operative VTA ablation (n = 50) versus conventional medical management (n = 50) with LVAD implant. Arrhythmia outcomes data will be captured by an implantable cardioverter defibrillator (ICD) to monitor VTA events, with a uniform ICD programming protocol. Patients will be followed prospectively over a mean of 18 months (with a minimum of 9 months) after LVAD implantation to evaluate recurrent VTA, adverse events, and procedural outcomes. Secondary endpoints include right heart function/hemodynamics, healthcare utilization, and quality of life. CONCLUSION: The primary aim of this first-ever randomized trial is to assess the efficacy of intra-operative ablation during LVAD surgery in reducing VTA recurrence and improving clinical outcomes for patients with a history of VTA.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Taquicardia Ventricular , Humanos , Coração Auxiliar/efeitos adversos , Estudos Prospectivos , Qualidade de Vida , Fatores de Risco , Eletrocardiografia , Arritmias Cardíacas , Taquicardia Ventricular/etiologia , Resultado do Tratamento
7.
Cardiol Clin ; 41(3): 429-448, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37321693

RESUMO

Systemic diseases can cause heart block owing to the involvement of the myocardium and thereby the conduction system. Younger patients (<60) with heart block should be evaluated for an underlying systemic disease. These disorders are classified into infiltrative, rheumatologic, endocrine, and hereditary neuromuscular degenerative diseases. Cardiac amyloidosis owing to amyloid fibrils and cardiac sarcoidosis owing to noncaseating granulomas can infiltrate the conduction system leading to heart block. Accelerated atherosclerosis, vasculitis, myocarditis, and interstitial inflammation contribute to heart block in rheumatologic disorders. Myotonic, Becker, and Duchenne muscular dystrophies are neuromuscular diseases involving the myocardium skeletal muscles and can cause heart block.


Assuntos
Artrite Reumatoide , Cardiopatias , Distrofias Musculares , Miocardite , Humanos , Distrofias Musculares/complicações , Arritmias Cardíacas , Bloqueio Cardíaco/complicações , Miocárdio , Miocardite/complicações , Artrite Reumatoide/complicações , Cardiopatias/etiologia
8.
JACC Clin Electrophysiol ; 9(8 Pt 1): 1404-1408, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37227346

RESUMO

The authors sought to evaluate a method for improving radiofrequency (RF) lesion durability using doxorubicin encased in heat-sensitive liposomes (HSL-dox). Using a porcine model, RF ablations were performed in the right atrium after systemic infusion of either HSL-dox or saline control given immediately before mapping and ablation. Lesion geometry was measured with voltage mapping immediately postablation and after 2 weeks of survival. After 2 weeks, lesions demonstrated less regression in scar area in HSL-dox-exposed animals compared with control animals. We demonstrate improved RF lesion durability in animals treated with HSL-dox, and the cardiotoxic effect was more pronounced after RF applications with higher power and longer duration.


Assuntos
Temperatura Alta , Lipossomos , Suínos , Animais , Miocárdio , Doxorrubicina/uso terapêutico , Átrios do Coração
9.
J Am Heart Assoc ; 12(9): e028483, 2023 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-37119087

RESUMO

Background Rhythm management is a complex decision for patients with atrial fibrillation (AF). Although clinical trials have identified subsets of patients who might benefit from a given rhythm-management strategy, for individual patients it is not always clear which strategy is expected to have the greatest mortality benefit or durability. Methods and Results In this investigation 52 547 patients with a new atrial fibrillation diagnosis between 2010 and 2020 were retrospectively identified. We applied a type of artificial intelligence called tabular Q-learning to identify the optimal initial rhythm-management strategy, based on a composite outcome of mortality, change in treatment, and sustainability of the given treatment, termed the reward function. We first applied an unsupervised learning algorithm using a variational autoencoder with K-means clustering to cluster atrial fibrillation patients into 8 distinct phenotypes. We then fit a Q-learning algorithm to predict the best outcome for each cluster. Although rate-control strategy was most frequently selected by treating providers, the outcome was superior for rhythm-control strategies across all clusters. Subjects in whom provider-selected treatment matched the Q-table recommendation had fewer total deaths (4 [8.5%] versus 473 [22.4%], odds ratio=0.32, P=0.02) and a greater reward (P=4.8×10-6). We then demonstrated application of dynamic learning by updating the Q-table prospectively using batch gradient descent, in which the optimal strategy in some clusters changed from cardioversion to ablation. Conclusions Tabular Q-learning provides a dynamic and interpretable approach to apply artificial intelligence to clinical decision-making for atrial fibrillation. Further work is needed to examine application of Q-learning prospectively in clinical patients.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/terapia , Fibrilação Atrial/tratamento farmacológico , Antiarrítmicos/uso terapêutico , Estudos Retrospectivos , Inteligência Artificial , Cardioversão Elétrica
10.
J Cardiovasc Electrophysiol ; 34(4): 880-887, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36682068

RESUMO

INTRODUCTION: Esophageal injury is a well-known complication associated with catheter ablation. Though novel methods to mitigate esophageal injury have been developed, few studies have evaluated temperature gradients with catheter ablation across the posterior wall of the left atrium, interstitium, and esophagus. METHODS: To investigate temperature gradients across the tissue, we developed a porcine heart-esophageal model to perform ex vivo catheter ablation on the posterior wall of the left atrium (LA), with juxtaposed interstitial tissue and esophagus. Circulating saline (5 L/min) was used to mimic blood flow along the LA and alteration of ionic content to modulate impedance. Thermistors along the region of interest were used to analyze temperature gradients. Varying time and power, radiofrequency (RF) ablation lesions were applied with an externally irrigated ablation catheter. Ablation strategies were divided into standard approaches (SAs, 10-15 g, 25-35 W, 30 s) or high-power short duration (HPSD, 10-15 g, 40-50 W, 10 s). Temperature gradients, time to the maximum measured temperature, and the relationship between measured temperature as a function of distance from the site of ablation was analyzed. RESULTS: In total, five experiments were conducted each utilizing new porcine posterior LA wall-esophageal specimens for RF ablation (n = 60 lesions each for SA and HPSD). For both SA and HPSD, maximum temperature rise from baseline was markedly higher at the anterior wall (AW) of the esophagus compared to the esophageal lumen (SA: 4.29°C vs. 0.41°C, p < .0001 and HPSD: 3.13°C vs. 0.28°C, p < .0001). Across ablation strategies, the average temperature rise at the AW of the esophagus was significantly higher with SA relative to HPSD ablation (4.29°C vs. 3.13°C, p = .01). From the start of ablation, the average time to reach a maximum temperature as measured at the AW of the esophagus with SA was 36.49 ± 12.12 s, compared to 16.57 ± 4.54 s with HPSD ablation, p < .0001. Fit to a linear scale, a 0.37°C drop in temperature was seen for every 1 cm increase in distance from the site of ablation and thermistor location at the AW of the esophagus. CONCLUSION: Both SA and HPSD ablation strategies resulted in markedly higher temperatures measured at the AW of the esophagus compared to the esophageal lumen, raising concern about the value of clinical intraluminal temperature monitoring. The temperature rise at the AW was lower with HPSD. A significant time delay was seen to reach the maximum measured temperature and a modest increase in distance between the site of ablation and thermistor location impacted the accuracy of monitored temperatures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Animais , Suínos , Temperatura , Fibrilação Atrial/cirurgia , Átrios do Coração , Esôfago/lesões , Ablação por Cateter/métodos
11.
Heart Rhythm O2 ; 4(3): 193-199, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36569386

RESUMO

Background: There are limited data on trends in nationwide cardiac electrophysiology (EP) procedures in the United States before and during the global COVID-19 pandemic. Objective: We aimed to understand contemporary EP procedural trends and how the COVID-19 pandemic impacted them. Methods: Trends were obtained from publicly reported Centers for Medicare and Medicaid Services data from 2013 to 2020 (latest available). Rates of catheter-based EP procedures (EP studies and ablations) and cardiac implantable electronic device (CIED) procedures were analyzed. All procedural rates were calculated per 100,000 Medicare beneficiaries (year specific). Procedure physician subspecialty was also reported. Results: From 2013 to 2019, annual rate of all cardiac EP procedures increased from 817.91 to 1089.68 per 100,000 beneficiaries. Catheter-based EP procedures increased from 323.73 to 675.01, while CIED rates decreased from 494.18 to 414.67. While all ablation procedures increased over time, relative proportion of ablation procedures being pulmonary vein isolation (PVI) increased (9.9% of ablations in 2013, to 18.2% in 2019). In 2020, rates of both catheter-based EP procedures and CIED procedures decreased; however, PVI share of ablation continued to increase in 2020 comprising 25.2% of ablation procedures. Conclusion: Rates of EP procedures have increased among Medicare beneficiaries, with catheter-based procedures now eclipsing CIEDs. Additionally, a greater proportion of catheter-based EP procedures are PVI, but they still represent a minority of all ablations. In 2020, rates of EP procedures were attenuated, yet the proportion of PVI ablations increased to over one-fourth of ablation procedures. These data have important implications for the EP workforce.

12.
Circ Cardiovasc Interv ; 15(12): e012183, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36472194

RESUMO

BACKGROUND: Left atrial appendage occlusion is an important alternative to anticoagulation in select patients with nonvalvular atrial fibrillation. Trends in real-world device sizing and associated short-term complications have not been characterized. METHODS: Using the National Cardiovascular Data Left Atrial Appendage Occlusion (NCDR LAAO) Registry, patients who underwent left atrial appendage occlusion with a Watchman 2.5 device from January 1, 2016, to June 30, 2020, were identified. Patients were stratified by device size based on left atrial appendage orifice size, and categorized as receiving a device that was undersized, oversized, or per manufacturer recommendation. Relationships between device sizing and short-term outcomes, including pericardial effusion, device embolism, and significant leak, were assessed. RESULTS: Of the 68 456 patients, 6539 (10.5%) of patients received undersized devices, 17 791 (26.0%) according to manufacturer recommendations, and 44 126 (64.4%) received an oversized device. The 27-mm device was most commonly deployed [21 736 (31.8%)], whereas the smallest and largest devices (21 and 33 mm) were least commonly deployed [7695 (11.2%) and 9077 (13.3%), respectively]. Compared with manufacturer recommended sizing, there was no difference in the odds of pericardial effusion for either undersized (1.048 [95% CI' 0.801-1.372]; P=0.733) or oversized (1.101 [95% CI' 0.933-1.298]; P=0.254) devices. Similarly, relative to manufacturer recommended sizing, the odds of a composite adverse outcome of device migration or embolization and significant peridevice leak at 45 days were similar among undersized devices (1.030 [95% CI' 0.735-1.444]; P=0.863) and favorable for oversized devices (0.701 [95% CI' 0.561-0.876]; P=0.002) devices, primarily driven by lower odds of leak. Selection of oversized devices increased significantly over the study period (from 60.3% in 2016 to 66.0% in 2020; P<0.001). CONCLUSIONS: Among patients undergoing left atrial appendage occlusion with the first-generation Watchman device, receipt of oversized devices was common and increased over time. The high prevalence of oversizing was associated with lower odds of significant leak or device embolization without increased odds of other adverse events.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Derrame Pericárdico , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/diagnóstico por imagem , Derrame Pericárdico/epidemiologia , Derrame Pericárdico/etiologia , Resultado do Tratamento , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Sistema de Registros , Acidente Vascular Cerebral/etiologia , Cateterismo Cardíaco/efeitos adversos
13.
Ther Adv Infect Dis ; 9: 20499361221141772, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36506697

RESUMO

Approximately 300,000 people in the United States are estimated to have Chagas' disease, with cardiac manifestations including arrhythmias occurring in 20%-30% of patients. We report a patient diagnosed with Chagas' cardiomyopathy after presenting in ventricular tachycardia. This patient was asymptomatic before her presentation with recurrent episodes of ventricular tachycardia, which motivated us to screen her since she was an immigrant from an endemic Chagas region. This manuscript highlights some of the characteristic cardiac magnetic resonance imaging (MRI) and electrophysiology findings present in patients with Chagas' cardiomyopathy. We also detail the management of patients with Chagas' cardiomyopathy who have suffered from ventricular tachycardia.

14.
Circ Cardiovasc Qual Outcomes ; 15(11): e009352, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36378770

RESUMO

BACKGROUND: Shared decision making (SDM) is gaining importance in cardiology, including Centers for Medicare & Medicaid Services (CMS) reimbursement policies requiring documented SDM for patients considering primary prevention implantable cardioverter defibrillators. The DECIDE-ICD Trial (Decision Support Intervention for Patients offered implantable Cardioverter-Defibrillators) assessed the implementation and effectiveness of patient decision aids (DAs) using a stepped-wedge design at 7 sites. The purpose of this subanalysis was to qualitatively describe electrophysiology clinicians' experience implementing and using the DAs. METHODS: This included semi-structured individual interviews with electrophysiology clinicians at participating sites across the US, at least 6 months following conversion into the implementation phase of the trial (from June 2020 through February 2022). The interview guide was structured according to the RE-AIM (Reach, Effectiveness, Adoption, Implementation and Maintenance [implementation evaluation model]) framework, assessing clinician experiences, which can impact implementation domains, and was qualitatively assessed using a mixed inductive/deductive method. RESULTS: We completed 22 interviews post-implementation across all 7 sites. Participants included both physicians (n=16) and other clinicians who counsel patients regarding treatment options (n=6). While perception of SDM and the DA were positive, participants highlighted reasons for uneven delivery of DAs to appropriate patients. The CMS mandate for SDM was not universally viewed as associating with patients receiving DA's, but rather (1) logistics of DA delivery, (2) perceived effectiveness in improving patient decision-making, and (3) match of DA content to current patient populations. Remaining tensions include the specific trial data used in DAs and reconciling timing of delivery with when patients are actively making decisions. CONCLUSIONS: Clinicians charged with delivering DAs to patients considering primary prevention implantable cardioverter defibrillators were generally supportive of the tenets of SDM, and of the DA tools themselves, but noted several opportunities to improve the reach and continued use of them in routine care. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique Identifier: NCT03374891.


Assuntos
Técnicas de Apoio para a Decisão , Desfibriladores Implantáveis , Idoso , Humanos , Tomada de Decisões , Tomada de Decisão Compartilhada , Medicare , Participação do Paciente , Estados Unidos
15.
JACC Case Rep ; 4(18): 1180-1185, 2022 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-36213880

RESUMO

We describe a rare complication of esophago-pericardial fistula after epicardial ventricular tachycardia ablation. Echocardiogram revealed evidence of pneumopericardium and additional imaging studies confirmed esophageal leak with evidence of fistula formation requiring prompt surgical repair. (Level of Difficulty: Intermediate.).

17.
Circ Arrhythm Electrophysiol ; 15(10): e011110, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36166690

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a novel energy modality for treatment of cardiac arrhythmias. The impact of electrode-tissue proximity on lesion formation by PFA has not been conclusively assessed. The objective of this investigation was to evaluate the effects of electrode-tissue proximity on cardiac lesion formation with a biphasic, bipolar PFA system. METHODS: PFA was delivered on the ventricular epicardial surface in an isolated porcine heart model (n=8) via a 4-electrode prototype catheter. An offset tool was designed to control the distance between electrodes and target tissue; deliveries were placed 0 mm (0 mm offset), 2 mm (2 mm offset), and 4 mm away from the tissue (4 mm offset). Lesions were assessed using tetrazolium chloride staining. Numerical models for the experimental setup with and without the offset tool validated and supported results. RESULTS: Cardiac lesion dimensions decreased proportional to the distance between epicardial surface and electrodes. Lesion depth averaged 4.3±0.4 mm, 2.7±0.4 mm, and 1.3±0.4 mm for the 0, 2, and 4 mm and lesion width averaged 9.4±1.1 mm, 7.5±0.8 mm and 5.8±1.4 mm for the 0, 2, and 4 mm offset distances, respectively. Numerical modeling matched ex vivo results well and predicted lesion creation with and without the offset tool. CONCLUSIONS: Using a biphasic, bipolar PFA system resulted in cardiac lesions even in the 0 mm offset distance case. The relationship between lesion depth and offset distance was linear, and the deepest lesions were created with 0 mm offset distance, that is, with electrodes in contact with tissue. Therefore, close electrode-tissue proximity increases the likelihood of achieving transmural lesions by maximizing the electric field penetration into the target tissue.


Assuntos
Ablação por Cateter , Suínos , Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cloretos , Eletrodos , Ventrículos do Coração/cirurgia , Coração
19.
JACC Clin Electrophysiol ; 8(7): 843-853, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35643806

RESUMO

BACKGROUND: Unipolar electrograms (UniEGMs) are commonly used to annotate earliest local activation of focal arrhythmias. However, their utility in guiding premature ventricular contractions (PVCs) ablation may be limited when the PVC source is less superficial. OBJECTIVES: The authors sought to compare bipolar electrograms (BiEGMs) vs UniEGMs in guiding successful ablation of right ventricular outflow tract (RVOT) vs intramural outflow tract (OT) PVCs. The authors hypothesized that: 1) earliest bipolar local activation time (LATBi) would better guide mapping and ablation, vs UniEGM dV/dt (LATUni) or QS morphology; and 2) LAT differences using bipolar vs unipolar EGMs (ΔLATBi-Uni) would be greater for intramural OT than RVOT PVCs. METHODS: Consecutive patients undergoing successful PVC ablation 2017 to2020 requiring only RVOT or RVOT+left ventricular OT (RVOT+LVOT) ablation were retrospectively analyzed. BiEGMs and UniEGMs at successful ablation sites were compared. RESULTS: Of 70 patients, 50 required RVOT-only, and 20 required RVOT+LVOT ablation for acute and long-term PVC suppression. Mean ΔLATBi-Uni was lower for RVOT vs RVOT+LVOT groups (9.3 ± 6.4 ms vs 17.4 ± 9.9 ms; P < 0.01). QS UniEGM was seen in 78% of RVOT, compared with 53% of RVOT+LVOT patients (P < 0.016). RVOT+LVOT sites most frequently included the posteroseptal RVOT and adjacent LVOT (73%), and 43% lacked a QS unipolar EGM. ΔLATBi-Uni ≥15 ms best distinguished sites in which RVOT-only vs RVOT+LVOT ablation achieved acute PVC suppression (area under the curve: 0.77). CONCLUSIONS: Earliest BiEGM activation guides successful ablation of OT PVCs better than UniEGM-guided analysis, especially when an intramural PVC source is present.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Estudos Retrospectivos , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Complexos Ventriculares Prematuros/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...