Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biosensors (Basel) ; 14(7)2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-39056597

RESUMO

Due to rapid industrialization, novel water-quality monitoring techniques for the detection of highly toxic and hazardous heavy metal ions are essential. Herein, a hybrid noble nanoparticle/DNAzyme electrochemical biosensor is proposed for the simultaneous and label-free detection of Pb2+ and Cr3+ in aqueous solutions. The sensor is based on the combination of a two-dimensional naked-platinum nanoparticle film and DNAzymes, whose double-helix configuration disassembles into smaller fragments in the presence of target-specific heavy metal ions. The electrochemical behavior of the fabricated sensor was investigated with non-faradaic electrochemical impedance spectroscopy (EIS), resulting in the successful detection of Pb2+ and Cr3+ well below their maximum permitted levels in tap water. So far, there has been no report on the successful detection of heavy metal ions utilizing the non-faradaic electrochemical impedance spectroscopy technique based on advanced nanomaterials paired with DNAzymes. This is also one of the few reports on the successful detection of chromium (III) via a sensor incorporating DNAzymes.


Assuntos
Técnicas Biossensoriais , DNA Catalítico , Espectroscopia Dielétrica , Metais Pesados , DNA Catalítico/química , Metais Pesados/análise , Nanopartículas Metálicas/química , Platina/química , Íons , Cromo/análise , Chumbo/análise , Nanopartículas/química , Técnicas Eletroquímicas
2.
Sensors (Basel) ; 23(18)2023 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-37765875

RESUMO

A hybrid noble nanoparticle/DNAzyme electrochemical biosensor is proposed for the detection of Pb2+, Cd2+, and Cr3+. The sensor takes advantage of a well-studied material that is known for its selective interaction with heavy metal ions (i.e., DNAzymes), which is combined with metallic nanoparticles. The double-helix structure of DNAzymes is known to dissociate into smaller fragments in the presence of specific heavy metal ions; this results in a measurable change in device resistance due to the collapse of conductive inter-nanoparticle DNAzyme bridging. The paper discusses the effect of DNAzyme anchoring groups (i.e., thiol and amino functionalization groups) on device performance and reports on the successful detection of all three target ions in concentrations that are well below their maximum permitted levels in tap water. While the use of DNAzymes for the detection of lead in particular and, to some extent, cadmium has been studied extensively, this is one of the few reports on the successful detection of chromium (III) via a sensor incorporating DNAzymes. The sensor showed great potential for its future integration in autonomous and remote sensing systems due to its low power characteristics, simple and cost-effective fabrication, and easy automation and measurement.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA