Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 99(21): e20049, 2020 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-32481272

RESUMO

RATIONALE: Rifabutin is a broad-spectrum antibiotic known to cause deposits on the corneal endothelium and lens. We report a patient in whom cataracts developed and progressive pigment deposits were seen on the corneal endothelium, lens, and iridocorneal angle. PATIENT CONCERNS: The patient was a 45-year-old woman who had been received long-term treatment with a combination of various anti-mycobacterial drugs for multidrug-resistant tuberculosis starting in 2004. Rifabutin was started in 2009, and she was referred to our department in 2017 for detailed ophthalmological examination. DIAGNOSES: Both eyes showed pigmented deposits over the entire corneal endothelium, the entire periphery of the iridocorneal angle, and the anterior surface of the lens. Mild cataracts were also diagnosed bilaterally. Pigment deposits on the anterior surface of the lens and the cataracts in both eyes gradually progressed. These lesions were assumed to be associated with long term rifabutin intake. INTERVENTIONS: Rifabutin intake was discontinued after progression of intraocular deposits, cataracts, and ERG deterioration. OUTCOMES: Visual acuity improved, although cataracts, deposits, and ERG deterioration remained. LESSONS: Rifabutin may induce not only corneal endothelial deposits, but also cataracts and iridocorneal angle deposits.


Assuntos
Antibacterianos/efeitos adversos , Catarata/induzido quimicamente , Doenças da Córnea/induzido quimicamente , Rifabutina/efeitos adversos , Antibacterianos/administração & dosagem , Feminino , Humanos , Pessoa de Meia-Idade , Rifabutina/administração & dosagem , Tuberculose Resistente a Múltiplos Medicamentos/tratamento farmacológico
2.
Cutan Ocul Toxicol ; 38(2): 156-160, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30404545

RESUMO

PURPOSE: In this study, we investigated the effects of commercially available multi-dose sodium hyaluronate 0.1% (Hyalein®; Santen, Osaka, Japan) containing 0.003% C12-benzalkonium chloride (BAC) on the Corneal epithelium and its degree of safety. METHODS: Japanese white male rabbits were divided into four groups. The corneas of each group exposed to one of the following solutions: sodium hyaluronate 0.1%, C12-BAC, C12, 14, 16-BAC Mixture, and Hank's Balanced Salt Solution (HBSS) (as control), respectively. Corneal transepithelial electrical resistance (TER) changes after 60 s of exposure to the above solutions were measured in living rabbits. TER reflects the barrier function of the epithelium. In addition, scanning electron microscopy was used to examine the acute effects of the above solutions on the integrity of the corneal epithelium of four groups. RESULTS: There was no significant decrease in the corneal TER after exposure of the cornea to Hyalein® eye drops as compared to HBSS control eyes. Also, BAC mixture solution and C12-BAC did not produce any significant decrease in the corneal TER as compared to HBSS control eyes. All the corneal epithelium exposed to Hyalein®, 0.003% C12-BAC and 0.003% BAC mixture exhibited a regular appearance of the superficial cells with a high density of microvilli. CONCLUSION: This study confirms that Hyalein® has no acute hazardous effect on corneal epithelium.


Assuntos
Compostos de Benzalcônio/toxicidade , Epitélio Corneano/efeitos dos fármacos , Ácido Hialurônico/toxicidade , Soluções Oftálmicas/toxicidade , Conservantes Farmacêuticos/toxicidade , Animais , Masculino , Coelhos
3.
Am J Ophthalmol Case Rep ; 13: 62-65, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30582074

RESUMO

PURPOSE: To report three cases of acute sterile corneal melt after cataract surgery. OBSERVATIONS: Case 1 was a 21-year-old male presenting with a corneal perforation of his right eye at 10 days after cataract surgery. Case 2 was a 67-year-old male who developed a corneal melt in his left eye at 15 days after cataract surgery. Case 3 was a 70-year-old female with a corneal melt of her left eye at 7 days after cataract surgery. None of the cases exhibited any signs of infection. Topical nonsteroidal anti-inflammatory drug use, dry eye, systemic autoimmune diseases, and/or a combination of these were present in patients who developed corneal melt after cataract surgery. CONCLUSIONS AND IMPORTANCE: Corneal melt cases can occur early after cataract surgery, thereby leading to corneal thinning and perforation.

4.
Jpn J Ophthalmol ; 62(4): 443-450, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29700642

RESUMO

PURPOSE: To investigate the corneal biomechanics in eyes with keratectasia following LASIK using a dynamic Scheimpflug analyzer. DESIGN: Case-Control study. METHOD: The subjects in the study included 12 eyes with keratectasia after LASIK (KE), 24 eyes with keratoconus (KC), 17 eyes without keratectasia after LASIK (LASIK), and 34 eyes with normal corneas (Normal). Corneal biomechanics of the four groups were evaluated using a dynamic Scheimpflug analyzer. RESULTS: Compared with Normal (7.06 ± 0.54), the radius at the highest concavity (radius, mm) of LASIK (5.96 ± 0.76), KE (4.93 ± 0.61) and KC (5.39 ± 1.02) were significantly small. The Deflection Amplitude (HCDLA, mm) of Normal (0.94 ± 0.07) was significantly lower than those of KE (1.11 ± 0.10) and KC (1.06 ± 0.16), and was not significantly different from that of LASIK (0.98 ± 0.07). There were significant differences between LASIK and KE in radius and HCDLA (P < 0.05), whereas KE and KC had no differences in these parameters. CONCLUSIONS: Corneal biomechanical features evaluated using the dynamic Scheimpflug analyzer suggest that biomechanical properties in eyes with keratectasia, keratoconus, and LASIK are different from those of normal eyes. Although the biomechanics in eyes with keratectasia differs from that in eyes with LASIK, it is similar to that in eyes with keratoconus.


Assuntos
Córnea/fisiopatologia , Doenças da Córnea/fisiopatologia , Topografia da Córnea/instrumentação , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Complicações Pós-Operatórias/fisiopatologia , Adulto , Fenômenos Biomecânicos , Córnea/patologia , Doenças da Córnea/diagnóstico , Doenças da Córnea/etiologia , Dilatação Patológica , Feminino , Humanos , Ceratocone/cirurgia , Masculino , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos
5.
Intern Med ; 57(12): 1783-1788, 2018 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-29321417

RESUMO

A 67-year-old Japanese man was diagnosed with granulomatosis with polyangiitis based on the presence of right maxillary sinusitis, proteinase 3 antineutrophil cytoplasmic antibody positivity, and right scleritis. A conjunctival biopsy specimen showed neutrophil-predominant infiltration around the vessels without granuloma. Because there was a risk of blindness, pulsed methylprednisolone and intravenous cyclophosphamide pulse therapy (IVCY) were started. However, it was ineffective, and peripheral ulcerative keratitis newly emerged. We promptly switched the treatment from IVCY to rituximab, and ophthalmologists performed amniotic membrane transplantation, which avoided blindness. The close and effective working relationship between physicians and ophthalmologists improved our patient's ocular prognosis.


Assuntos
Úlcera da Córnea/complicações , Úlcera da Córnea/tratamento farmacológico , Ciclofosfamida/uso terapêutico , Granulomatose com Poliangiite/complicações , Rituximab/uso terapêutico , Idoso , Humanos , Masculino , Metilprednisolona/uso terapêutico , Prognóstico
6.
Pharmacology ; 98(1-2): 56-61, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27078164

RESUMO

AIM: This study aimed to investigate acute corneal toxicity of commercially available diquafosol 3% ophthalmic solution (Diquas®), which contains C12 benzalkonium chloride (BAC) as a preservative. METHODS: Corneal transepithelial electrical resistance (TER) changes after a 60-second exposure to Diquas® (diquafosol 3% preserved with 0.0075% C12 BAC); 0.0075% C12 BAC and 0.0075% C12, C14, C16 BAC mixture were measured in living rabbits. Corneal damage was also examined by scanning electron microscopy (SEM). Hank's balanced salt solution (HBSS) was used as a control. RESULTS: Diquas® and 0.0075% C12 BAC did not produce any significant decrease in the corneal TER as compared to the HBSS control eyes. There was a significant decrease in the corneal TER after exposure of the cornea to the 0.0075% C12, C14, C16 BAC mixture (p < 0.01). SEM revealed that the superficial cells of the corneas exposed to the 0.0075% BAC mixture were damaged and exhibited degenerated microvilli. Conversely, the superficial cells of corneas exposed to Diquas® or 0.0075% C12 BAC appeared normal and had normal microvilli under SEM examinations. CONCLUSION: The acute corneal toxicity of Diquas® is less than that of the 0.0075% BAC mixture. Diquas® preserved with 0.0075% C12 BAC did not show acute corneal toxicity.


Assuntos
Compostos de Benzalcônio/toxicidade , Doenças da Córnea/induzido quimicamente , Soluções Oftálmicas/toxicidade , Polifosfatos/toxicidade , Conservantes Farmacêuticos/toxicidade , Nucleotídeos de Uracila/toxicidade , Animais , Doenças da Córnea/patologia , Epitélio Corneano/efeitos dos fármacos , Epitélio Corneano/patologia , Epitélio Corneano/ultraestrutura , Masculino , Microscopia Eletrônica de Varredura , Coelhos
7.
Curr Eye Res ; 41(10): 1326-1330, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27002346

RESUMO

PURPOSE: To investigate the corneal toxicity of three combined antiglaucoma topical eyedrops using transepithelial electrical resistance (TER) and scanning electron microscopy (SEM). METHODS: Corneal TER changes after a 60-s exposure to latanoprost/timolol with 0.02% benzalkonium chloride (BAC), travoprost/timolol with polyquaternium-1, and dorzolamide/timolol with 0.005% BAC were measured in living rabbits. Corneal damage was also examined by SEM. Hank's balanced salt solution (HBSS) was used as a control. RESULTS: There was a significant decrease in the corneal TER after exposure of the cornea to latanoprost/timolol with 0.02% BAC. Travoprost/timolol with polyquaternium-1 and dorzolamide/timolol with 0.005% BAC did not produce any significant decrease in the corneal TER as compared to HBSS control eyes. SEM revealed that superficial cells of corneas treated with latanoprost/timolol with 0.02% BAC were damaged and exhibited degenerated microvilli. Conversely, the superficial cells of corneas exposed to travoprost/timolol with polyquaternium-1 or dorzolamide/timolol with 0.005% BAC appeared normal and had normal microvilli under SEM examinations. CONCLUSION: The corneal toxicity of latanoprost/timolol with 0.02% BAC is greater than that of travoprost/timolol with polyquaternium-1 and dorzolamide/timolol with 0.005% BAC. Latanoprost/timolol contains 0.02% BAC, which may be responsible for the corneal toxicity.


Assuntos
Anti-Hipertensivos/toxicidade , Córnea/efeitos dos fármacos , Glaucoma/tratamento farmacológico , Administração Tópica , Animais , Anti-Hipertensivos/administração & dosagem , Córnea/fisiopatologia , Córnea/ultraestrutura , Modelos Animais de Doenças , Impedância Elétrica , Glaucoma/diagnóstico , Glaucoma/fisiopatologia , Masculino , Microscopia Eletrônica de Varredura , Soluções Oftálmicas/administração & dosagem , Soluções Oftálmicas/toxicidade , Coelhos
8.
Ocul Surf ; 14(1): 37-42, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26462410

RESUMO

PURPOSE: To evaluate acute corneal permeability changes after instillation of benzalkonium chloride (BAC) using a newly developed in vivo less invasive corneal transepithelial electrical resistance (TER) measurement method in animals and humans. METHODS: We previously developed an in vivo method for measuring corneal TER using intraocular electrodes in animals. This method can be used to precisely measure the decline of the corneal barrier function after instillation of BAC. To lessen the invasiveness of that procedure, we further refined the method for measuring the corneal TER by developing electrodes that could be placed on the surface of the cornea and in the conjunctival sac instead of inserting them into the anterior chamber. Corneal TER changes before and after exposure to 0.02% BAC were determined in this study using the new device in both rabbits and humans. RESULTS: There was a significant decrease in the corneal TER after exposure of the cornea to 0.02% BAC solution in both rabbits and humans (P<.01). The results of this new less invasive method agreed with those of formerly established anterior chamber methods in rabbit experiments. CONCLUSION: This new less invasive corneal TER measurement method enables us for the first time to measure TER of the human cornea, allowing safe and reliable investigation of the direct effect of different eye drop treatments on the corneal epithelium.


Assuntos
Compostos de Benzalcônio/farmacocinética , Permeabilidade da Membrana Celular/fisiologia , Epitélio Corneano/fisiopatologia , Animais , Impedância Elétrica , Epitélio Corneano/metabolismo , Masculino , Conservantes Farmacêuticos/farmacocinética , Coelhos
9.
Cutan Ocul Toxicol ; 35(2): 120-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26113030

RESUMO

PURPOSE: To investigate the corneal toxicity of Xalatan and three latanoprost generics using transepithelial electrical resistance (TER) and scanning electron microscopy (SEM). METHODS: Corneal TER changes after a 60-s exposure to Xalatan (latanoprost 0.005% preserved with 0.02% BAC), and latanoprost generics (Latanoprost PF BAC free, Latanoprost Nitten SB containing sodium benzoate and Latanoprost Towa containing 0.01% BAC with sodium chloride polysorbate 80 as additive) were measured in living rabbits. Corneal damage was also examined by SEM. Hank's balanced salt solution (HBSS) was used as a control. RESULTS: There was a significant decrease in the corneal TER after exposure of the cornea to Xalatan (p < 0.01) and all latanoprost generics (p < 0.01: Latanoprost PF, p < 0.05: Latanoprost Nitten SB, Latanoprost Towa) as compared to HBSS. All latanoprost generics showed less TER decrease in the corneal TER as compared to Xalatan (p < 0.01). SEM revealed that superficial cells of Xalatan-treated corneas were damaged and exhibited degenerated microvilli. Conversely, the superficial cells of corneas exposed to HBSS or all latanoprost generics appeared normal and had normal microvilli under SEM examinations. CONCLUSION: The corneal toxicity of Xalatan is greater than that of latanoprost generics. Xalatan contains 0.02% BAC, which may be responsible for the corneal toxicity.


Assuntos
Compostos de Benzalcônio/efeitos adversos , Medicamentos Genéricos/efeitos adversos , Epitélio Corneano/efeitos dos fármacos , Soluções Oftálmicas/efeitos adversos , Conservantes Farmacêuticos/efeitos adversos , Prostaglandinas F Sintéticas/efeitos adversos , Animais , Impedância Elétrica , Epitélio Corneano/fisiologia , Epitélio Corneano/ultraestrutura , Latanoprosta , Masculino , Microscopia Eletrônica de Varredura , Coelhos
10.
Artigo em Inglês | MEDLINE | ID: mdl-26291653

RESUMO

PURPOSE: To develop a device that is capable of easily measuring corneal transepithelial electrical resistance (TER) and changes in the corneal barrier function. METHODS: We had previously developed an in vivo method for measuring corneal TER using intraocular electrode. This method can be used to precisely measure the decline of the corneal barrier function after instillation of benzalkonium chloride (BAC). In order to lessen the invasiveness of that procedure, we further refined the method for measuring the corneal TER by developing electrodes that could be placed on the cornea and in the conjunctival sac instead of inserting them into the anterior chamber. TER was then calculated by subtracting the electrical resistance, which lacked the corneal epithelial input, from the whole electrical resistance that was measured between the electrodes. Slit lamp examination and scanning electron microscopy (SEM) were used to determine safety of the new device. Corneal TER changes after exposure to 0.02% BAC were determined using the new device as well as SEM and transmission electron microscopy (TEM). RESULTS: Slit lamp examination before and after exposure of rabbits' corneas to the sensor confirmed safety of the device. SEM examination revealed no difference of the corneal epithelium which exposed to the new device with normal corneas. SEM and TEM pictures revealed damaged microvilli and tight junctions after instillation of 0.02% BAC. TER change after treatment with 0.02%BAC was similar to those determined by the established anterior chamber method. CONCLUSION: We succeeded to develop a less invasive device for corneal TER measurement in vivo in animals. This new device may be applicable in the future for clinical use in humans.


Assuntos
Epitélio Corneano/fisiologia , Epitélio Corneano/ultraestrutura , Pletismografia de Impedância/instrumentação , Pletismografia de Impedância/métodos , Animais , Impedância Elétrica , Eletrodos , Fenômenos Eletrofisiológicos , Desenho de Equipamento , Masculino , Microscopia Eletrônica de Varredura , Soluções Oftálmicas/administração & dosagem , Coelhos , Lâmpada de Fenda
11.
Jpn J Ophthalmol ; 58(6): 483-9, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25190024

RESUMO

PURPOSE: To compare the corneal biomechanical properties of eyes that have undergone penetrating keratoplasty (PK), deep anterior lamellar keratoplasty (DALK), and Descemet stripping automated endothelial keratoplasty (DSAEK). METHODS: This case-control study comprised 20 post-PK eyes, 14 post-DALK eyes, 15 post-DSAEK eyes, and 50 normal control eyes. A dynamic Scheimpflug analyzer (the Corvis ST) was used to evaluate the corneal biomechanical properties including deformation amplitude (DA) and radius at the highest concavity (R hc). RESULTS: In post-PK eyes, the mean DA was 1.20 ± 0.13 mm, which was significantly higher than those of the control eyes (1.07 ± 0.09) and the post-DSAEK eyes (1.08 ± 0.12). The DA (1.18 ± 0.18) in the post-DALK eyes was significantly higher than in the control eyes. The R hc in the post-PK (6.34 ± 0.37 mm), -DALK (6.04 ± 1.22), and -DSAEK (6.44 ± 0.58) eyes was significantly smaller than in the control eyes (7.57 ± 0.78). CONCLUSIONS: The dynamic Scheimpflug analyzer provides a method to obtain new biomechanical information on the cornea such as the DA and R hc, and these parameters differed among eyes that had undergone 3 different types of corneal surgery. Abnormalities in these parameters after the different corneal transplantation techniques may indicate larger deviations in the stress-strain reaction of the cornea and more uncertainty in the intraocular pressure measurements than in normal eyes.


Assuntos
Córnea/fisiopatologia , Doenças da Córnea/cirurgia , Transplante de Córnea , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Elasticidade/fisiologia , Ceratoplastia Penetrante , Adulto , Idoso , Fenômenos Biomecânicos , Estudos de Casos e Controles , Doenças da Córnea/fisiopatologia , Técnicas de Diagnóstico Oftalmológico/instrumentação , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
12.
Am J Ophthalmol ; 156(3): 543-547.e1, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23688711

RESUMO

PURPOSE: To evaluate subfoveal choroidal thickness in patients with central retinal vein occlusion (CRVO) using enhanced depth imaging optical coherence tomography. DESIGN: Retrospective observational study. METHODS: We measured bilateral subfoveal choroidal thickness, averaged for 100 scans, in 36 patients (mean age, 66 ± 15 years; 26 women and 10 men) with unilateral CRVO by using the enhanced depth imaging methods of the Spectralis optical coherence tomography system. Twenty-two patients were treated with intravitreal bevacizumab (1.25 mg/0.05 mL), and subfoveal choroidal thickness was measured before and after treatment. Statistical analysis was performed to compare subfoveal choroidal thickness of CRVO and fellow eyes and to compare subfoveal choroidal thickness before and after intravitreal bevacizumab. RESULTS: Mean subfoveal choroidal thickness measured in 36 eligible eyes of 36 patients was 257.1 ± 83.2 µm, which was significantly greater than that in fellow eyes (222.6 ± 67.8 µm; P < .01, paired t test). There was strong correlation between CRVO eyes and fellow eyes (r = 0.79, P < .01). Mean subfoveal choroidal thickness after intravitreal bevacizumab was 227.7 ± 65.1 µm, which was significantly thinner than that before intravitreal bevacizumab therapy (266.9 ± 79.0 µm; P < .01, paired t test). CONCLUSIONS: Subfoveal choroidal thickness of CRVO eyes was significantly greater than that of fellow eyes and decreased significantly after intravitreal bevacizumab treatment. Enhanced depth imaging optical coherence tomography can be used to evaluate choroidal involvement in CRVO and may assist noninvasive diagnosis and management of this disease.


Assuntos
Corioide/patologia , Oclusão da Veia Retiniana/diagnóstico , Tomografia de Coerência Óptica , Adulto , Idoso , Idoso de 80 Anos ou mais , Inibidores da Angiogênese/uso terapêutico , Anticorpos Monoclonais Humanizados/uso terapêutico , Bevacizumab , Corantes , Feminino , Angiofluoresceinografia , Humanos , Verde de Indocianina , Injeções Intravítreas , Masculino , Pessoa de Meia-Idade , Oftalmoscopia , Oclusão da Veia Retiniana/tratamento farmacológico , Estudos Retrospectivos , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...