Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 151(4): 621-5, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22923244

RESUMO

In Europe, a network for biological dosimetry has been created to strengthen the emergency preparedness and response capabilities in case of a large-scale nuclear accident or radiological emergency. Through the RENEB (Realising the European Network of Biodosimetry) project, 23 experienced laboratories from 16 European countries will establish a sustainable network for rapid, comprehensive and standardised biodosimetry provision that would be urgently required in an emergency situation on European ground. The foundation of the network is formed by five main pillars: (1) the ad hoc operational basis, (2) a basis of future developments, (3) an effective quality-management system, (4) arrangements to guarantee long-term sustainability and (5) awareness of the existence of RENEB. RENEB will thus provide a mechanism for quick, efficient and reliable support within the European radiation emergency management. The scientific basis of RENEB will concurrently contribute to increased safety in the field of radiation protection.


Assuntos
Proteção Radiológica , Liberação Nociva de Radioativos , Defesa Civil , Emergências , Europa (Continente) , Humanos , Liberação Nociva de Radioativos/prevenção & controle
2.
Appl Radiat Isot ; 55(4): 493-503, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11545502

RESUMO

The EUROMET project 428 examines efficiency transfer results for Ge gamma-ray spectrometers when the efficiency is known for a reference point source geometry. For this, different methods are used, such as Monte Carlo simulation or semi-empirical computation. The exercise compares the application of these methods to the same selected experimental cases to determine the usage limitations versus the requested accuracy. For carefully examining these results and trying to derive information for improving the computation codes, this study was limited to a few simple cases. The first part concerns the simplest case of geometry transfer, i.e., using point sources for 3 source-to-detector distances: 2, 5 and 20 cm; the second part deals with transfer from point source geometry to cylindrical geometry with three different matrices. The general conclusion is that the deviations between the computed results and the measured efficiencies are mostly within 10%. The quality of the results is rather inhomogeneous and shows that these codes cannot be used directly for metrological purposes. However, most of them are operational for routine measurements when efficiency uncertainties of 5-10% can be sufficient.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA