Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Sci Rep ; 13(1): 14089, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37640771

RESUMO

Left ventricular (LV) myocardial mass is important in the evaluation of cardiac remodeling and requires accurate assessment when performed on linear measurements in two-dimensional echocardiography (Echo). We aimed to compare the accuracy of the Devereaux formula (DEV) and the Teichholz formula (TEICH) in calculating LV myocardial mass in Echo using cardiac magnetic resonance (CMR) as the reference method. Based on preceding mathematical calculations, we identified primarily LV size rather than wall thickness as the main source of bias between DEV and TEICH in a retrospective derivation cohort (n = 1276). Although LV mass from DEV and TEICH were correlated with CMR, TEICH did not show a proportional bias as did DEV (- 2 g/m2 vs. + 22 g/m2). This could be validated in an independent prospective cohort (n = 226) with symptomatic non-ischemic heart failure. DEV systematically overestimated LV mass in all tiers of LV remodeling as compared to TEICH. In conclusion, the TEICH method accounts for the changes in LV geometry with increasing LV mass and thus better reflects the different pattern of LV remodeling than the DEV method. This has important clinical implications, as TEICH may be more appropriate for use in clinical practice, rather than DEV, currently recommended.


Assuntos
Insuficiência Cardíaca , Coração , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Miocárdio
3.
Korean Circ J ; 53(5): 331-343, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37161747

RESUMO

BACKGROUND AND OBJECTIVES: The prognostic implication of right atrial (RA) and left atrial (LA) size for an immediate success of direct current cardioversion (DCCV) in atrial fibrillation (AF) remains unclear. This study aimed to compare RA and LA size for the prediction of DCCV success. METHODS: Between 2012 and 2018, 734 consecutive outpatients were screened for our prospective registry. Each eligible patient received a medical history, blood analysis, and transthoracic echocardiography with a focus on indexed RA (iRA) area and LA volume (iLAV) prior to DCCV with up to three biphasic shocks (200-300-360 J) or additional administration of amiodarone or flecainide to restore sinus rhythm. RESULTS: We enrolled 589 patients, and DCCV was in 89% (n=523) successful. Mean age was 68 ± 10 years, and 40% (n=234) had New York heart association class >II. A prevalence of the male sex (64%, n=376) and of persistent AF (86%, n=505) was observed. Although DCCV success was associated with female sex (odds ratio [OR], 1.88; 95% confidence interval [CI], 1.06-3.65), with absence of coronary heart disease and normal left ventricular function (OR, 2.24; 95% CI, 1.26-4.25), with short AF duration (OR, 1.93; 95% CI, 1.05-4.04) in univariable regression, only iRA area remained a stable and independent predictor of DCCV success (OR, 0.27; 95% CI, 0.12-0.69; area under the curve 0.71), but not iLAV size (OR, 1.16; 95% CI, 1.05-1.56) in multivariable analysis. CONCLUSIONS: iRA area is superior to iLAV for the prediction of immediate DCCV success in AF.

4.
J Cardiovasc Electrophysiol ; 34(1): 44-53, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36259713

RESUMO

BACKGROUND: Renal denervation (RDN) can reduce cardiac sympathetic activity maintained by arterial hypertension (aHT). Its potential antiarrhythmic effect on rhythm outcome in patients with multi-drug resistant aHT undergoing catheter ablation for atrial fibrillation (AF) is unclear. METHODS: The RDN+AF study was a prospective, randomized, two-center trial. Patients with paroxysmal or persistent AF and uncontrolled aHT (mean systolic 24-h ambulatory BP > 135 mmHg) despite taking at least three antihypertensive drugs were enrolled. Patients were 1:2 randomized to either RDN+AF ablation or AF-only ablation. Primary endpoint was freedom from any AF episode > 2 min at 12 months assessed by implantable loop recorder (ILR) or 7d-holter electrocardiogram. Secondary endpoints included rhythm outcome at 24 months, blood pressure control, periprocedural complications, and renovascular safety. RESULTS: The study randomized 61 patients (mean age 65 ± 9 years, 53% men). At 12 months, RDN+AF patients tended to have a greater decrease in ambulatory BPs but did not reach statistical significance. No differences in rhythm outcome were observed. Freedom from AF recurrence in the RDN+AF and AF-only group measured 61% versus 53% p = .622 at 12 months and 39% versus 47% p = .927 at 24 months, respectively. Periprocedural complications occurred in 9/61 patients (15%). No patient died. CONCLUSION: Among patients with multidrug-resistant aHT and paroxysmal or persistent AF, concomitant RDN+AF ablation was not associated with better blood pressure control or rhythm outcome in comparison to AF-only ablation and medical therapy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Hipertensão , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Estudos Prospectivos , Resultado do Tratamento , Hipertensão/diagnóstico , Hipertensão/cirurgia , Simpatectomia/efeitos adversos , Ablação por Cateter/efeitos adversos , Recidiva
5.
Heart Rhythm O2 ; 3(5): 553-559, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36340492

RESUMO

Background: Interventional cardiac magnetic resonance (iCMR) has been established as a radiation-free alternative compared to standard fluoroscopy-guided catheter ablation for cavotricuspid isthmus (CTI)-dependent atrial flutter to image anatomy, structural alterations, and further catheter guidance. Objective: The purpose of this study was to explore the safety, feasibility, and efficacy of CTI ablations performed completely in the iCMR suite using active catheter imaging. Methods: Consecutive patients underwent iCMR-guided catheter ablation for CTI-dependent atrial flutter. Procedures were performed in a 1.5-T magnetic resonance (MR) imaging unit with MR-conditional ablation catheters. Catheter guidance was achieved using active catheter imaging via integrated MR receive tip coils. Acute success, periprocedural complications, and short-term follow-up were collected for further analysis. Results: All patients (N = 15; 73% male; median age 70 years; interquartile range [67-82]) achieved acute procedural success without any complication. Median procedural time was 43 minutes [33-58] with median radiofrequency delivery time of 18 minutes [12-26]. Postprocedural lesion visualization scanning was completed in a median of 32 minutes [10-42]. None of the patients with 6-month follow-up had atrial flutter recurrence. Conclusion: In the iCMR suite, CTI-dependent atrial flutter ablation could be achieved safely using active catheter imaging without any complication. It further allows detailed anatomic visualization of the CTI, intraprocedural lesion visualization, and exclusion of pericardial effusion.

6.
Biomarkers ; 27(3): 293-298, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35138209

RESUMO

BACKGROUND: An excessive inflammatory reaction after acute myocardial infarction (AMI) is known to be harmful. New anti-inflammatory therapies are required. PURPOSE: This study assessed the predictive role of early CRP in patients with STEMI. METHODS: A total of 1003 patients with STEMI were analysed. A total of 180 patients with proven infection were excluded. CRP after 12, 24 and 48 h after pain onset were evaluated. RESULTS: Of 823 patients, 103 (12.5%) died within one year after AMI. The deceased patients showed higher CRP, even after already 12 h (6 vs. 13 mg/l, p < .001), 24 h (13 vs. 25 mg/l, p < .001) and after 48 h (40 vs. 92 mg/l, p < .001). A CRP of ≥8 mg/l, 12 h after AMI, was found in 45% and was independently associated with long-term mortality (OR: 2.7, p = .03), after 24 h: CRP ≥ 18 mg/l in 44% (OR: 2.5, p = .03), after 48 h: CRP ≥ 53 mg/l in 44% (OR 1.9, p = .03). Early CRP values correlated strongly with the later maximum value of CRP (p < .001). CONCLUSIONS: Already early CRP values are accurate for risk-prediction following AMI. By identifying patients who are beginning to develop an excessive inflammatory response, it may be possible to identify those who benefit from anti-inflammatory therapies.


Assuntos
Infarto do Miocárdio , Infarto do Miocárdio com Supradesnível do Segmento ST , Biomarcadores , Proteína C-Reativa/análise , Humanos , Inflamação , Infarto do Miocárdio/diagnóstico , Prognóstico
7.
NEJM Evid ; 1(11): EVIDoa2200141, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38319851

RESUMO

Low-Voltage Myocardium Ablation Trial of Persistent AFWe investigated ablation approaches in 324 patients with persistent AF by comparing ablation with PVI alone and PVI plus individualized SM. Patients had electrocardiogram recordings over 12 months of observation. Recurrent AF was documented in 50% of PVI only and 35% of PVI+SM patients. AEs occurred in six PVI+SM versus three PVI-alone patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Miocárdio , Recidiva , Resultado do Tratamento
8.
Front Neurosci ; 15: 667011, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34267622

RESUMO

Animal brains still outperform even the most performant machines with significantly lower speed. Nonetheless, impressive progress has been made in robotics in the areas of vision, motion- and path planning in the last decades. Brain-inspired Spiking Neural Networks (SNN) and the parallel hardware necessary to exploit their full potential have promising features for robotic application. Besides the most obvious platform for deploying SNN, brain-inspired neuromorphic hardware, Graphical Processing Units (GPU) are well capable of parallel computing as well. Libraries for generating CUDA-optimized code, like GeNN and affordable embedded systems make them an attractive alternative due to their low price and availability. While a few performance tests exist, there has been a lack of benchmarks targeting robotic applications. We compare the performance of a neural Wavefront algorithm as a representative of use cases in robotics on different hardware suitable for running SNN simulations. The SNN used for this benchmark is modeled in the simulator-independent declarative language PyNN, which allows using the same model for different simulator backends. Our emphasis is the comparison between Nest, running on serial CPU, SpiNNaker, as a representative of neuromorphic hardware, and an implementation in GeNN. Beyond that, we also investigate the differences of GeNN deployed to different hardware. A comparison between the different simulators and hardware is performed with regard to total simulation time, average energy consumption per run, and the length of the resulting path. We hope that the insights gained about performance details of parallel hardware solutions contribute to developing more efficient SNN implementations for robotics.

10.
Europace ; 23(9): 1400-1408, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-33693595

RESUMO

AIMS: To characterize the association of phasic left atrial (LA) transport function and LA fibrosis guided by multimodality imaging containing cardiac magnetic resonance imaging (CMR) feature tracking and bipolar voltage mapping. METHODS AND RESULTS: Consecutive patients presenting for first-time ablation of atrial fibrillation (AF) were prospectively enrolled. Each patient underwent CMR prior to the ablation procedure. LA phasic indexed volumes (LA-Vi) and emptying fractions (LA-EF) were calculated and CMR feature tracking guided LA wall motion analysis was performed. LA bipolar voltage mapping was carried out in sinus rhythm to find areas of low voltage as a surrogate for fibrosis and arrhythmogenesis. One hundred and sixty-eight patients were enrolled. Low-voltage areas (LVAs) were present in 70 patients (42%). Contrary to LA volume, CMR based LA-EF [odds ratio (OR) 0.88, 95% confidence interval (CI) 0.80-0.96, P = 0.005] and LA booster pump strain rate (SR) (OR 0.98, 95% CI 0.97-0.99, P = 0.001) significantly predicted presence and extent of LVA in multivariate logistic regression analysis for patients scanned in SR. In receiver operating characteristic analysis, LA-EF <40% carried a sensitivity of 83% and specificity of 76% (area under the curve 0.8; 95% CI 0.71-0.89) to predict presence of LVA. For patients scanned in AF only minimal LA-Vi on CMR (OR: 1.06; 95% CI: 1.02-1.10; P = 0.002) predicted presence of LVA. CONCLUSION: For patients scanned in SR LA-EF and LA booster pump SR are closely linked to the presence and extent of LA LVA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Fibrose , Átrios do Coração/cirurgia , Humanos , Espectroscopia de Ressonância Magnética
11.
Europace ; 22(12): 1812-1821, 2020 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-32830233

RESUMO

AIMS: Atrial fibrillation (AF) and heart failure (HF) often coexist. Catheter ablation has been reported to restore left ventricular (LV) function but patients benefit differently. This study investigated the correlation between left atrial (LA) fibrosis extent and LV ejection fraction (LVEF) recovery after AF ablation. METHODS AND RESULTS: In this study, 103 patients [64 years, 69% men, 79% persistent AF, LVEF 33% interquartile range (IQR) (25-38)] undergoing first time AF ablation were investigated. Identification of LA fibrosis and selection of ablation strategy were based on sinus rhythm voltage mapping. Continuous rhythm monitoring was used to assess ablation success. Improvement in post-ablation LVEF was measured as primary study endpoint. An absolute increase in post-ablation LVEF ≥10% was defined as 'Super Response'. Left atrial fibrosis was present in 38% of patients. After ablation LVEF increased by absolute 15% (IQR 6-25) (P < 0.001). Left ventricular ejection fraction improvement was higher in patients without LA fibrosis [15% (IQR 10-25) vs. 10% (IQR 0-20), P < 0.001]. An inverse correlation between LVEF improvement and the extent of LA fibrosis was found (R2 = 0.931). In multivariate analysis, the presence of LA fibrosis was the only independent predictor for failing LVEF improvement [odds ratio 7.2 (95% confidence interval 2.2-23.4), P < 0.001]. Echocardiographic 'Super Response' was observed in 55/64 (86%) patients without and 21/39 (54%) patients with LA fibrosis, respectively (P < 0.001). CONCLUSION: Presence and extent of LA fibrosis predict LVEF response in HF patients undergoing AF ablation. The assessment of LA fibrosis may impact prognostic stratification and clinical management in HF patients with AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Feminino , Fibrose , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
13.
J Cardiovasc Electrophysiol ; 31(4): 885-894, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32037614

RESUMO

BACKGROUND: Left atrial substrate modification targeting low voltage zones (LVZ) is an ablation strategy that-in addition to pulmonary vein (PV) isolation-tries to eliminate arrhythmogenic mechanisms harbored in such tissue. Electrophysiological findings at reablation include (a) PV reconnection, (b) reconnection over previous substrate ablation, and (c) de-novo LVZ. OBJECTIVE: To study, prevalence and contribution of these arrhythmogenic electrophysiological entities in patients with atrial fibrillation (AF) recurrences. METHODS: Consecutive patients with highly symptomatic AF undergoing index and reablation were included (n = 113). In all patients' PV reconnection, reconnection over previous substrate ablation and spontaneous de-novo LVZ were quantitatively assessed and integrated into an individual reablation strategy. Follow-up was based on continuous device monitoring. RESULTS: At re-do procedure, 45 out of 113 (39.8%) patients showed PV reconnection as the only electrophysiological abnormality. Reconduction over previous lines was the only electrophysiological abnormality in 8 out of 113 (7.1%) patients. Spontaneous de-novo LVZ was the only electrophysiological abnormality in 12 out of 113 (10.6%) patients. Combined findings of PV reconnection, line reconduction, and/or spontaneous de-novo LVZ were seen in 40 out of 113 (35.4%) patients. No detectable electrophysiological abnormality was observed in 8 out of 113 (7.1%) patients. In univariate analysis, none of the tested electrophysiological characteristics independently predicted the outcome after re-do. CONCLUSIONS: In patients undergoing reablation, we could show that reconduction over previous substrate ablation as well as the development of new low voltage areas are frequent findings besides classical PV reconnection-without a clear leading cause for recurrences. These findings impact reablation strategies as well as the strategic focus during index procedures.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
14.
Circ J ; 83(3): 595-603, 2019 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-30662022

RESUMO

BACKGROUND: Left ventricular (LV) torsion is a key parameter in cardiac function and predicts functional capacity (FC) more appropriately than LV ejection fraction (EF). We sought to investigate LV torsion as a marker of hospitalization for worsening heart failure (HF) in non-ischemic dilated cardiomyopathy (DCM) patients. Methods and Results: The 91 outpatients with newly diagnosed DCM (53±13 years, 20% female) were evaluated with 3D speckle-tracking imaging and followed up for 12 months; 43 healthy sex- and age-matched volunteers served as controls. LV torsion, LVEF, right ventricular function, LV global longitudinal (GLS) and circumferential (GCS) strain values, peak oxygen uptake (peak V̇O2) from FC and B-type natriuretic peptide levels were measured at baseline. Peak V̇O2correlated successively with LV torsion, diastolic filling and GCS (r=0.70, -0.52 and -0.41, P<0.01) disclosing the central role of LV torsion. During follow-up (median 272 days), 24 (26%) cardiac events occurred. A reduced LV torsion (<0.59 degrees/cm) predicted cardiac events similar to a reduced peak V̇O2(<19 mL/kg/min) (unadjusted hazard ratio 6.41 and 5.90, P<0.001). LV torsion provided a significant incremental value over right ventricular function and peak V̇O2(C-index: 0.85, P=0.02). CONCLUSIONS: The results demonstrated a clear relation between LV torsion and disease severity, suggesting that LV torsion has additional prognostic relevance in DCM patients.


Assuntos
Cardiomiopatia Dilatada/diagnóstico , Ecocardiografia/métodos , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Fenômenos Biomecânicos , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/fisiopatologia , Estudos de Casos e Controles , Ecocardiografia Tridimensional/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico
15.
Europace ; 20(FI_3): f312-f320, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29688326

RESUMO

Aims: To study device performance, arrhythmia recurrence characteristics, and methods of outcome assessment using a novel implantable cardiac monitor (ICM) in patients undergoing ablation for atrial fibrillation (AF). Methods and results: In 419 consecutive patients undergoing first-time catheter ablation for symptomatic paroxysmal (n = 224) or persistent (n = 195) AF an ICM was injected at the end of the procedure. Telemedicine staff ensured full episode transmission coverage and manually evaluated all automatic arrhythmia episodes. Device detection metrics were calculated for ≥2, ≥6, and ≥10 min AF detection durations. Four methods of outcome assessment were studied: continuous recurrence analysis, discontinuous recurrence analysis, AF-burden analysis, and analysis of individual rhythm profiles. A total of 43 673 automatic AF episodes were transmitted over a follow-up of 15 ± 6 months. Episode-based positive predictive values changed significantly with longer AF detection durations (70.5% for ≥2 min, 81.8% for ≥6 min, and 85.9% for ≥10 min). Patients with exclusive short episode recurrences (≥2 to <6 min) were rare and their arrhythmia detection was clinically irrelevant. Different methods of outcome assessment showed a large variation (46-79%) in ablation success. Individual rhythm characteristics and subclinical AF added to this inconsistency. Analysis of AF-burden and individual rhythm profiles were least influenced and showed successful treatment in 60-70% of the patients. Conclusion: We suggest AF detection duration >6 min and AF burden >0.1% as a standardized outcome definition for AF studies to come in the future.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia Ambulatorial/métodos , Frequência Cardíaca , Telemedicina/métodos , Telemetria/métodos , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Equipamentos para Diagnóstico , Eletrocardiografia Ambulatorial/instrumentação , Desenho de Equipamento , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Recidiva , Telemedicina/instrumentação , Telemetria/instrumentação , Fatores de Tempo , Resultado do Tratamento
16.
Open Heart ; 5(1): e000733, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29531762

RESUMO

Objectives: Non-ischaemic dilated cardiomyopathy (DCM) is characterised by a highly variable disease progression. Stress echocardiography and cardiopulmonary exercise testing (CPET) are beneficial in risk assessment, but are labour intensive. Repetitive squatting and standing without weights is a simple exercise (EX). The aim of this study was to investigate the prognostic role of left ventricular (LV) contractile recruitment (CR) after a simple EX of repetitive squatting through three-dimensional (3D) echocardiography. Methods: Patients with DCM (LV ejection fraction (EF)<50%, n=68) and age-matched healthy volunteers (n=25) received a 3D echocardiographic evaluation of LV EF before and after 30 repetitions of squatting-standing EX. CR was defined by the change of LV EF (Δ>4%). Patients were followed up prospectively (2 years) for cardiac death and deteriorating heart failure. Results: During follow-up, 14 cardiac events occurred (21%) with six deaths and eight severe heart failure deteriorations. A poor CR after squatting EX differentiated DCM patients with cardiac events during follow-up as accurately as a reduced peak oxygen consumption (peak VO 2<20 mL/kg/min) (sensitivity: 0.97 and 0.95). Both had a significant incremental diagnostic value over clinical (age, dyspnoea and natriuretic peptide level) or resting echocardiographic parameters (E/E' ratio, LV EF and end-diastolic LV volume) to predict cardiac events (global χ2: 16.0 vs 5.3; 19.5 vs 6.1; P<0.01 for all). Conclusions: The presence of LV CR after EX of repetitive squatting without weights can stratify risk and predict cardiac events in patients with DCM as correct as CPET.

17.
Circ Arrhythm Electrophysiol ; 11(2): e005748, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29439000

RESUMO

BACKGROUND: Until today, catheter interventional mapping and ablation of atrial fibrillation (AF) has been limited to the right and left atrial endocardium. We report feasibility, electrophysiological findings, and clinical outcome using a combined endo-/epicardial catheter approach for mapping and ablation of AF. METHODS AND RESULTS: Fifty-nine patients with permanence of pulmonary vein isolation and further symptomatic recurrences of paroxysmal AF, persistent AF, or atrial tachycardia underwent reablation using biatrial endo-/epicardial mapping and ablation. Identification of arrhythmia substrates and selection of ablation strategy were based on sinus rhythm voltage mapping. Using continuous monitoring and a 3-month blanking period, freedom from AF/atrial tachycardia ≥2 minutes was defined as primary end point. In all patients, endo-/epicardial mapping and ablation was feasible using standard technologies of catheter access, 3-dimensional mapping, and radiofrequency ablation. Epicardial mapping and ablation did not add procedural risks. Exclusively epicardial low voltage substrates were found in 14% of the patients. For the first time, novel epicardial conduction abnormalities located in the epicardial fiber network were described in human AF patients (19% of the cohort). Epicardial ablation was needed in 80% of the patients. Over 23±10 months of follow-up freedom from arrhythmia recurrences measured 73%. CONCLUSIONS: Catheter-based endo-/epicardial mapping and ablation of AF was feasible and safe. Epicardial mapping provided new insights into AF mechanisms. Epicardial ablation increased transmurality of ablation lesions. Clinical outcome in this cohort of complex AF patients was favorable, indicating potential further development of current AF treatment.


Assuntos
Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Endocárdio/cirurgia , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Pericárdio/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Estudos de Viabilidade , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
18.
Europace ; 20(3): 459-465, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28073885

RESUMO

Aims: It is hypothesized that inflammation could promote structural and electrical remodelling processes in atrial fibrillation (AF). Atrial infiltration of monocytes and granulocytes has been shown to be dependent on CD11b expression. The aim of this study was to investigate whether treatment of AF by pulmonary vein isolation (PVI) may lead to reduced inflammation, as indicated by a decrease of CD11b expression on monocytes and granulocytes. Methods and results: Flow-cytometric quantification analysis and determination of systemic inflammatory markers of peripheral blood were performed in 75 patients undergoing PVI 1 day before and 6 months after PVI. The extent of activation of monocytes and granulocytes was measured by quantifying the cell adhesion molecule CD11b. The mean expression of CD11b on monocytes (20.9 ± 2.5 vs. 10.2 ± 1.4; P < 0.001) and granulocytes (13.9 ± 1.6 vs. 6.8 ± 0.5; P < 0.001), as well as the relative count of CD11b-positive monocytes (P < 0.05) and CD11b-positive granulocytes (P < 0.01) were significantly reduced when comparing the identical patients before and 6 months after PVI. Systemic inflammatory parameters showed only a declining tendency after 6 months. Patients with unsuccessful PVI and ongoing AF on the day of follow-up showed no decrease in CD11b expression. Conclusions: A significant reduction of CD11b expression on monocytes and granulocytes, as a sign of reduced cellular inflammation, was achieved by treatment of AF using PVI. These data strongly support that AF is not only a consequence of but also a cause for inflammatory processes, which, in turn, may contribute to atrial remodelling.


Assuntos
Fibrilação Atrial/cirurgia , Antígeno CD11b/metabolismo , Ablação por Cateter , Granulócitos/metabolismo , Mediadores da Inflamação/metabolismo , Monócitos/metabolismo , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/imunologia , Fibrilação Atrial/metabolismo , Fibrilação Atrial/fisiopatologia , Remodelamento Atrial , Antígeno CD11b/imunologia , Ablação por Cateter/efeitos adversos , Regulação para Baixo , Feminino , Granulócitos/imunologia , Frequência Cardíaca , Humanos , Mediadores da Inflamação/imunologia , Masculino , Pessoa de Meia-Idade , Monócitos/imunologia , Veias Pulmonares/fisiopatologia , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
Front Neurorobot ; 11: 2, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28179882

RESUMO

Combined efforts in the fields of neuroscience, computer science, and biology allowed to design biologically realistic models of the brain based on spiking neural networks. For a proper validation of these models, an embodiment in a dynamic and rich sensory environment, where the model is exposed to a realistic sensory-motor task, is needed. Due to the complexity of these brain models that, at the current stage, cannot deal with real-time constraints, it is not possible to embed them into a real-world task. Rather, the embodiment has to be simulated as well. While adequate tools exist to simulate either complex neural networks or robots and their environments, there is so far no tool that allows to easily establish a communication between brain and body models. The Neurorobotics Platform is a new web-based environment that aims to fill this gap by offering scientists and technology developers a software infrastructure allowing them to connect brain models to detailed simulations of robot bodies and environments and to use the resulting neurorobotic systems for in silico experimentation. In order to simplify the workflow and reduce the level of the required programming skills, the platform provides editors for the specification of experimental sequences and conditions, environments, robots, and brain-body connectors. In addition to that, a variety of existing robots and environments are provided. This work presents the architecture of the first release of the Neurorobotics Platform developed in subproject 10 "Neurorobotics" of the Human Brain Project (HBP). At the current state, the Neurorobotics Platform allows researchers to design and run basic experiments in neurorobotics using simulated robots and simulated environments linked to simplified versions of brain models. We illustrate the capabilities of the platform with three example experiments: a Braitenberg task implemented on a mobile robot, a sensory-motor learning task based on a robotic controller, and a visual tracking embedding a retina model on the iCub humanoid robot. These use-cases allow to assess the applicability of the Neurorobotics Platform for robotic tasks as well as in neuroscientific experiments.

20.
Circ J ; 81(4): 529-536, 2017 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-28123150

RESUMO

BACKGROUND: LV twist has a key role in maintaining left ventricular (LV) contractility during exercise. The purpose of this study was to investigate LV torsion instead of twist as a surrogate marker of peak oxygen uptake (peak V̇O2) assessed by cardiopulmonary exercise testing (CPET) in patients with non-ischemic dilated cardiomyopathy (DCM).Methods and Results:We evaluated 45 outpatients with DCM (50±12 years, 24% females) with 3D speckle-tracking electrocardiography prior to CPET. LV torsion, LV ejection fraction (EF), LV diastolic function, LV global longitudinal (GLS) and circumferential (GCS) strain were quantified. A reduced functional capacity (FC) was defined as a peak V̇O2<20 mL/kg/min. LV torsion correlated most strongly with peak V̇O2(r=0.76, P<0.001). LV torsion instead of twist was an independent predictor of peak V̇O2(B: 0.59 to 0.71, P<0.001) in multivariable analyses. Impaired LV torsion <0.61 degrees/cm was able to predict a reduced FC with higher sensitivity and specificity (0.91 and 0.81; area under the curve (AUC): 0.88, P<0.001) than LV EF, GLS or GCS (AUC 0.64, 0.63 and 0.66; P<0.05 for differences in AUC). CONCLUSIONS: Peak V̇O2correlated more strongly with LV torsion than with LV diastolic function, LV EF, GLS or GCS. LV torsion had high accuracy in identifying patients with a reduced FC.


Assuntos
Cardiomiopatia Dilatada/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Adulto , Área Sob a Curva , Teste de Esforço/métodos , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio/fisiologia , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Torção Mecânica , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...