Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 155
Filtrar
1.
Cochrane Database Syst Rev ; 5: CD013023, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780138

RESUMO

BACKGROUND: Peripheral arterial catheters (ACs) are used in anaesthesia and intensive care settings for blood sampling and monitoring. Despite their importance, ACs often fail, requiring reinsertion. Dressings and securement devices maintain AC function and prevent complications such as infection. OBJECTIVES: To evaluate the effectiveness of peripheral AC dressing and securement devices to prevent failure and complications in hospitalised people. SEARCH METHODS: We searched the Cochrane Wounds Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL Plus up to 16 May 2023. We also searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform up to 16 May 2023. SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing different dressing and securement devices for the stabilisation of ACs in hospitalised people. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials for inclusion, extracted data, and assessed risk of bias using Cochrane's RoB 1 tool. We resolved disagreements by discussion, or by consulting a third review author when necessary. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included five RCTs with 1228 participants and 1228 ACs. All included studies had high risk of bias in one or more domains. We present the following four comparisons, with the remaining comparisons reported in the main review. Standard polyurethane (SPU) plus tissue adhesive (TA) compared with SPU: we are very uncertain whether use of SPU plus TA impacts rates of AC failure (risk ratio (RR) 0.44, 95% confidence interval (CI) 0.20 to 0.98; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Neither study (165 participants) reported catheter-related bloodstream infections (CRBSI), thus we are very uncertain whether SPU plus TA impacts on the incidence of CRBSI (very low-certainty evidence). It is very uncertain whether use of SPU plus TA impacts AC dislodgement risk (RR 0.54, 95% CI 0.03 to 9.62; I² = 44%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts AC occlusion rates (RR 1.20, 95% CI 0.37 to 3.91; I² = 3%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts rates of adverse events with few reported events across groups (RR 0.89, 95% CI 0.09 to 8.33; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Bordered polyurethane (BPU) compared to SPU: we are very uncertain whether use of BPU impacts rates of AC failure (RR 0.67, 95% CI 0.21 to 2.13; 1 study, 60 participants; very low-certainty evidence). BPU may make little or no difference to CRBSI compared to SPU (RR 3.05, 95% CI 0.12 to 74.45; I² = not applicable as 1 study (60 participants) reported 0 events; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to the risk of AC dislodgement compared with SPU (RR 0.75, 95% CI 0.17 to 3.22; I² = 0%; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to occlusion risk compared with SPU (RR 0.80, 95% CI 0.60 to 1.07; I² = 0%; 2 studies, 572 participants; low-certainty evidence). It is very uncertain whether BPU impacts on the risk of adverse events compared with SPU (RR 0.33, 95% CI 0.01 to 7.87; 1 study, 60 participants; very low-certainty evidence). SPU plus sutureless securement devices (SSD) compared to SPU: we are very uncertain whether SPU plus SSD impacts risk of AC failure compared with SPU (RR 0.78, 95% CI 0.40 to 1.52; I² = 0%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain if SPU plus SSD impacts CRBSI incidence rate with no events in both groups (2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of dislodgement (RR 0.14, 95% CI 0.01 to 2.57; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of AC occlusion (RR 1.94, 95% CI 0.50 to 7.48; I² = 38%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain whether SPU plus SSD impacts on the risk of adverse events (RR 1.94, 95% CI 0.19 to 20.24; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). Integrated securement dressings compared to SPU: integrated securement dressings may result in little or no difference in risk of AC failure compared with SPU (RR 1.96, 95% CI 0.80 to 4.84; 1 study, 105 participants; low-certainty evidence); may result in little or no difference in CRBSI incidence with no events reported (1 study, 105 participants; low-certainty evidence); may result in little or no difference in the risk of dislodgement (RR 0.33, 95% CI 0.04 to 3.04; 1 study, 105 participants; low-certainty evidence), may result in little or no difference in occlusion rates with no events reported (1 study, 105 participants; low-certainty evidence), and may result in little or no difference in the risk of adverse events (RR 0.35, 95% CI 0.01 to 8.45; 1 study, 105 participants; low-certainty evidence). AUTHORS' CONCLUSIONS: There is currently limited rigorous RCT evidence available about the relative clinical effectiveness of AC dressing and securement products. Limitations of current evidence include small sample size, infrequent events, and heterogeneous outcome measurements. We found no clear difference in the incidence of AC failure, CRBSI, or adverse events across AC dressing or securement products including SPU, BPU, SSD, TA, and integrated securement products. The limitations of current evidence means further rigorous RCTs are needed to reduce uncertainty around the use of dressing and securement devices for ACs.


Assuntos
Bandagens , Infecções Relacionadas a Cateter , Cateterismo Periférico , Poliuretanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Infecções Relacionadas a Cateter/prevenção & controle , Viés , Falha de Equipamento
2.
Rev Paul Pediatr ; 42: e2023159, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38747843

RESUMO

OBJECTIVE: To perform the translation and adaptation of the Michigan Appropriateness Guide for Intravenous Catheters in Pediatrics (miniMAGIC) into Brazilian Portuguese. METHODS: Methodological study performed in five recommended stages: initial translations; synthesis of the translations; back translations; assessment of the back translations; expert committee assessment. The expert committee was composed of three registered nurses and two doctors who had a Master's and/or PhD degree, and an expertise in intravenous therapy and pediatric and neonatal care. To assess the semantic, idiomatic, experiential and conceptual adequacy, a Likert scale was applied, in which 1, "not equivalent"; 2, "inequivalent"; 3, "cannot assess"; 4, "quite equivalent"; 5, "totally equivalent". The terms mostly analyzed as negative in equivalence and with a lower than 20 score were reviewed and submitted to a new assessment, with the Delphi Technique until consensus was obtained. The results were stored in electronic spreadsheets and treated with concordance index, with a minimum acceptable result of 0.80. RESULTS: The content of all recommendations, named as miniMAGIC-Brasil, was validated by the expert committee after two stages of evaluation. All recommendations had an overall agreement index of 0.91. CONCLUSIONS: The miniMAGIC-Brazil guide was validated in respect to the adequacy of the translation after two steps.


Assuntos
Traduções , Humanos , Brasil , Criança , Guias de Prática Clínica como Assunto , Pediatria/normas
3.
Semin Oncol Nurs ; : 151618, 2024 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-38622044

RESUMO

OBJECTIVES: To identify the prevalence and type of central venous access device-associated skin complications for adult cancer patients, describe central venous access device management practices, and identify clinical and demographic characteristics associated with risk of central venous access device-associated skin complications. METHODS: A prospective cohort study of 369 patients (626 central venous access devices; 7,682 catheter days) was undertaken between March 2017 and March 2018 across two cancer care in-patient units in a large teaching hospital. RESULTS: Twenty-seven percent (n = 168) of participants had a central venous access device-associated skin complication. In the final multivariable analysis, significant (P < .05) risk factors for skin complications were cutaneous graft versus host disease (2.1 times greater risk) and female sex (1.4 times greater risk), whereas totally implanted vascular access device reduced risk for skin complications by two-thirds (incidence risk ratio 0.37). CONCLUSION: Central venous access device-associated skin complications are a significant, potentially avoidable injury, requiring cancer nurses to be aware of high-risk groups and use evidence-based preventative and treatment strategies. IMPLICATIONS FOR PRACTICE: This study has confirmed how common these potentially preventable injuries are. Therefore, the prevalence of these complications could be reduced by focusing on improvements in skin assessment, reductions in central venous access device dressing variation and improving clinician knowledge of this injury.

4.
JAMA Pediatr ; 178(5): 437-445, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38558161

RESUMO

Importance: Peripheral intravenous catheters (PIVCs) facilitate essential treatment. Failure of these essential devices is frequent and new securement strategies may reduce failure and improve patient outcomes. Objective: To evaluate clinical effectiveness of novel PIVC securement technologies for children to reduce catheter failure. Design, Setting, and Participants: A 3-arm, parallel group, superiority randomized clinical trial was conducted at 2 regional Australian hospitals from February 5, 2020, to January 14, 2022. Children aged 6 months to 8 years who were anticipated to require admission with a PIVC for at least 24 hours of in hospital treatment were eligible. Data were analyzed from May 25, 2022, to February 20, 2024. Interventions: Participants were randomly allocated in a 1:1:1 ratio to standard care, bordered polyurethane (Tegaderm [3M]), integrated securement dressing (SorbaView SHIELD [Medline]), and integrated securement dressing with tissue adhesive (Secureport IV). One catheter was studied per patient. Main Outcomes and Measures: Primary outcome was PIVC failure, defined as premature cessation of PIVC function for any reason prior to completion of planned treatment. Secondary outcomes were PIVC complications (any time dislodgement, occlusion, infiltration, partial dislodgement, extravasation, device leaking, phlebitis, pain), PIVC longevity, intervention acceptability (clinicians, participants, caregivers; 0-10 scale), and pain on removal (participants and caregivers; 0-10 scale relevant to age), adverse events, and health care costs. Results: A total of 383 patients (51% female; median age 36 [25th-75th percentiles, 22-72] months) were randomized 134 to standard care, 118 to integrated securement dressing, and 131 to integrated securement dressing with tissue adhesive. PIVC failure was lowest in integrated securement dressing with tissue adhesive (15 [12%]; adjusted hazard ratio [aHR], 0.47; 95% CI, 0.26-0.84) compared with integrated securement dressing (24 [21%]; aHR, 0.78; 95% CI, 0.47-1.28) and standard care (43 [34%]). Direct costs were significantly lower for integrated securement dressing with tissue adhesive (median, Australian dollars [A$], 312 [A$1 is equal to $0.65 US dollars]; IQR, A$302-A$380) and integrated securement dressing (median, A$303; IQR, A$294-A$465) compared with standard care (median, A$341; IQR, A$297-A$592; P ≤ .002) when considering the economic burden related to failure of devices. PIVC longevity and intervention acceptability were similar across all groups. Conclusions and Relevance: In this study, PIVCs secured with integrated securement dressings and tissue adhesive, in comparison with standard care, bordered polyurethane dressings, were associated with significantly reduced PIVC failure, for children admitted to hospital via the emergency department. Further research should focus on implementation in inpatient units where prolonged dwell and reliable intravenous access is most needed. Trial Registration: Australian New Zealand Clinical Trials Registry Identifier: ACTRN12619001026112.


Assuntos
Cateterismo Periférico , Falha de Equipamento , Humanos , Feminino , Masculino , Cateterismo Periférico/métodos , Cateterismo Periférico/instrumentação , Cateterismo Periférico/economia , Criança , Pré-Escolar , Lactente , Bandagens/economia , Austrália , Poliuretanos , Adesivos Teciduais/administração & dosagem
5.
J Adv Nurs ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38468151

RESUMO

BACKGROUND: Hospital-acquired pressure injuries (HAPIs) pose significant challenges in healthcare and cause increased patient suffering, longer hospital stays, and higher healthcare costs. Paediatric patients face unique risks, but evidence remains scarce. This study aimed to identify and describe HAPI admission incidence and severity predictors in a large Australian children's hospital. METHODS: This retrospective cohort study investigated all paediatric patients between January 2020 and December 2021 using a census approach. Demographic and clinical data including HAPI-related data were accessed from the incident monitoring and hospital administration databases. The incidence rate (per 1000 patient admissions) was calculated based on all admissions. Predictors of HAPI severity were identified using multivariable multinomial logistic regression. The study adhered to the STROBE guidelines for retrospective cohort studies. RESULTS: The HAPI incidence rate was 6.96 per 1000 patient admissions. Of the age groups, neonates had the highest HAPI incidence (15.5 per 1000 admissions). Critically ill children had the highest rate for admission location (12.8 per 1000 patient admissions). Most reported cases were stage I (64.2%). Age was associated with injury severity, with older paediatric patients more likely to develop higher-stage HAPIs. Additionally, Aboriginal and/or Torres Strait Islander patients had a higher HAPI severity risk. CONCLUSION: HAPI injuries in paediatric patients are unacceptably high. Prevention should be prioritized, and the quality of care improved in Australia and beyond. Further research is needed to develop targeted prevention strategies for these vulnerable populations. IMPLICATIONS FOR THE PROFESSION AND PATIENT CARE: This research emphasizes the need for standardized reporting, culturally sensitive care and tailored prevention strategies. IMPACT: The research has the potential to influence healthcare policies and practices, ultimately enhancing the quality of patient care. REPORTING METHOD: STROBE guidelines. NO PATIENT OR PUBLIC CONTRIBUTION: There was no patient or public contribution to the conduct of this study.

6.
Aust Crit Care ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38485556

RESUMO

BACKGROUND: Umbilical catheters are commonly inserted in newborns in the neonatal intensive care unit (NICU) yet are associated with serious adverse events (AEs) such as malposition, migration, infection, thrombosis, hepatic complications, cardiac effusion, and cardiac tamponade. There is a need to determine the incidence and risk factors for AEs to inform safe practice. OBJECTIVES: The objective of this study was to determine the incidence and risk factors for AEs (all-cause and individual types) associated with umbilical venous catheters (UVCs) and umbilical arterial catheters (UACs) in the NICU. METHODS: A retrospective cohort study was conducted in an Australian level-VI NICU over a 3-year period. Any newborn who had both a UVC and UAC insertion attempt was included. RESULTS: There were 236 neonates who had 494 catheters (245 UVCs and 249 UACs). Of these, 71% of UVCs (95% confidence interval [CI]: 65.6-76.9%; incidence rate: 181.1-237.3 per 1000 catheter days) and 43.8% of UACs (95% CI: 38-50.5%; incidence rate: 102.0-146.3 per 1000 catheter days) were associated with an AE. The most common AE was malposition on first X-ray for UVCs (60.1%, 95% CI: 55.1-67.3) and UACs (32.6%, 95% CI: 26.8-39.6). A dwell time of ≥7 days was a significant predictor of UAC failure (incidence risk ratio: 1.5, 95% CI: 1.1-2.1, p = 0.006) and migration of the UVC (incidence risk ratio: 3.5, 95% CI: 1.0-11.5, p = 0.043). CONCLUSION: Adverse events related to insertion occurred in a relatively high percentage of umbilical catheters placed. Increased dwell time remains a significant risk factor for catheter migration and overall failure. Practice change and consideration of risk factors for both individual and overall AE risk are necessary to reduce complications.

8.
J Clin Nurs ; 33(5): 1762-1776, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38413831

RESUMO

BACKGROUND: Healthcare consumers require diverse resources to assist their navigation of complex healthcare interactions, however, these resources need to be fit for purpose. AIM: In this study, we evaluated the utility, usability and feasibility of children, families and adults requiring long-term intravenous therapy using a recently developed mobile health application (App), intravenous (IV) Passport. DESIGN: Multi-site, parallel, multi-method, prospective cohort study. METHODS: A multi-site, multi-method study was carried out in 2020-2021, with 46 participants (20 adults, 26 children/family) reporting on their experiences surrounding the use of the IV Passport for up to 6 months. RESULTS: Overall, utility rates were acceptable, with 78.3% (N = 36) using the IV Passport over the follow-up period, with high rates of planned future use for those still active in the project (N = 21; 73%), especially in the child/family cohort (N = 13; 100%). Acceptability rates were high (9/10; IQR 6.5-10), with the IV Passport primarily used for documenting new devices and complications. Thematic analysis revealed three main themes (and multiple subthemes) in the qualitative data: Advocacy for healthcare needs, Complexity of healthcare and App design and functionality. CONCLUSION: Several recommendations were made to improve the end-user experience including 'how to' instructions; and scheduling functionality for routine care. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: The IV Passport can be safely and appropriately integrated into healthcare, to support consumers. IMPACT: Patient-/parent-reported feedback suggests the Intravenous Passport is a useful tool for record-keeping, and positive communication between patients/parents, and clinicians. REPORTING METHOD: Not applicable. PATIENT CONTRIBUTION: Consumers reported their experiences surrounding the use of the IV Passport for up to 6 months.


Assuntos
Telemedicina , Adulto , Criança , Humanos , Estudos Prospectivos , Telemedicina/métodos , Atenção à Saúde , Pais , Comunicação
9.
Hosp Pediatr ; 14(3): 180-188, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38404202

RESUMO

OBJECTIVES: This study aimed to describe how the current practice of peripherally inserted central catheter (PICC) use in hospitalized children aligns with the Michigan Appropriateness Guide for Intravenous Catheters (miniMAGIC) in Children recommendations, explore variation across sites, and describe the population of children who do not receive appropriate PICCs. METHODS: A retrospective study was conducted at 4 children's hospitals in the United States. Children with PICCs placed January 2019 to December 2021 were included. Patients in the NICU were excluded. PICCs were categorized using the miniMAGIC in Children classification as inappropriate, uncertain appropriateness and appropriate. RESULTS: Of the 6051 PICCs identified, 9% (n = 550) were categorized as inappropriate, 9% (n = 550) as uncertain appropriateness, and 82% (n = 4951) as appropriate. The number of PICCs trended down over time, but up to 20% of PICCs each year were not appropriate, with significant variation between sites. Within inappropriate or uncertain appropriateness PICCs (n = 1100 PICC in 1079 children), median (interquartile range) patient age was 4 (0-11) years, 54% were male, and the main reason for PICC placement was prolonged antibiotic course (56%, n = 611). The most common admitting services requesting the inappropriate/uncertain appropriateness PICCs were critical care 24%, general pediatrics 22%, and pulmonary 20%. Complications resulting in PICC removal were identified in 6% (n = 70) of inappropriate/uncertain PICCs. The most common complications were dislodgement (3%) and occlusion (2%), with infection and thrombosis rates of 1% (n = 10 and n = 13, respectively). CONCLUSIONS: Although the majority of PICCs met appropriateness criteria, a substantial proportion of PICCs were deemed inappropriate or of uncertain appropriateness, illustrating an opportunity for quality improvement.


Assuntos
Antibacterianos , Cateterismo Periférico , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Cateterismo Periférico/efeitos adversos , Catéteres , Criança Hospitalizada , Estudos Retrospectivos , Recém-Nascido , Lactente
10.
J Pediatr Nurs ; 76: 68-75, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38364591

RESUMO

PURPOSE: Children with chronic and complex health conditions frequently need intravenous devices. The current approach to intravenous device selection, insertion, and monitoring is inconsistent, and healthcare consumers are often negatively affected by siloed health information, and poor future planning. Despite child- and family-centred care being recognised as a pillar of paediatric nursing care, limited implementation for vascular access device planning and management is evident. DESIGN AND METHODS: To address this, we conducted a multi-phased approach to co-create, then evaluate, a mobile health (mHealth) application: IV Passport. Co-creation involved a prioritisation survey, followed by a Passport advisory panel consensus meeting. Following confirmation of the required content and features of the Passport, the mHealth application was designed and content validation achieved via survey. RESULTS: The prioritisation survey yielded recommendations for seven features (e.g., graphical presentations of current/past devices). Content for nine device types (e.g., totally implanted ports) was suggested, each with 10 related items (e.g., insertion site). Content items for device-associated complications, future vascular access plans, and educational resources were also suggested. Following design, the application was released through Apple and Android platforms; and adapted to a paper version. Content validation was established; 100% strongly agreed the application was easy to use; 80% agreed/strongly agreed that they would recommend the Passport to others. CONCLUSION: IV Passport embodies effective child- and family-centred care through consumer co-creation to empower patients and families manage vascular access devices. PRACTICE IMPLICATIONS: IV Passport remains active; and can be utilised across many healthcare settings and patient populations.


Assuntos
Telemedicina , Dispositivos de Acesso Vascular , Humanos , Criança , Aplicativos Móveis , Masculino , Feminino , Doença Crônica , Enfermagem Pediátrica
11.
Eur J Oncol Nurs ; 69: 102520, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38394934

RESUMO

PURPOSE: Central venous access devices play a crucial role in healthcare settings. However, there is concern regarding the high incidence of blockages occurring before the completion of treatments and existing guidelines for occlusion management are not consistently followed. To explore the decision-making and problem-solving process of occlusion management and identify enablers and barriers to implementing evidence for occlusion management in pediatric cancer care. METHODS: A qualitative design with individual semi-structured interviews. Participants were selected by purposeful sampling from a tertiary-referral pediatric facility, and semi-structured interviews were conducted. RESULTS: A total of 13 clinicians and 5 parents were interviewed. The thematic analysis revealed four main decision-making/problem-solving themes: 1) clinical reasoning and judgement for central venous access devices occlusion, 2) capability in central venous access devices occlusion management, 3) colleague collaboration in the escalation process and 4) lack of adequate support to manage the occlusion. This study identified positive and negative influences on the problem-solving process, including clinicians' psychological capabilities, social and physical resources, and beliefs about consequences. CONCLUSION: This study found that clinicians in pediatric cancer care were able to manage central venous access device occlusions using clinical reasoning and judgment skills, which may conflict with evidence-based practices. The study confirmed the importance of a team approach and prior experience in managing central venous access devices in pediatric oncology settings and identified potential conflicts between clinician decisions based on the patient's current and anticipated conditions and implementation of evidence-based practice. Improving documentation and providing visual aids could benefit clinicians' problem-solving processes.


Assuntos
Cateteres Venosos Centrais , Neoplasias , Humanos , Criança , Cateteres Venosos Centrais/efeitos adversos , Neoplasias/terapia , Oncologia , Pesquisa Qualitativa , Documentação
12.
Pediatrics ; 153(2)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38287882

RESUMO

CONTEXT: Central venous access device (CVAD) locks are routine interventions used to prevent and treat complications, such as infection, thrombosis, and catheter occlusion. OBJECTIVE: To compare and rank lock-solutions for prevention or treatment of complications in pediatrics. Design Systematic review and network meta-analysis. DATA SOURCES: Five databases and 2 clinical trial registries were searched. STUDY SELECTION: Published and unpublished randomized controlled trials that enrolled pediatric patients with a CVAD and compared the effectiveness of lock-solutions. DATA EXTRACTION: Data extraction was conducted by 2 reviewers. Odds ratio (OR) for prevention or treatment of CVAD-associated bloodstream infection (BSI), thrombosis, occlusion, CVAD-failure, and mortality were calculated, with point estimates ranking lock-solutions. RESULTS: Twenty-nine studies were included. Chelating agents and antibiotic locks given as prevention were associated with lower odds (OR: 0.11; 95% confidence interval [CI]: 0.02-0.67; moderate-quality; OR: 0.19; 95% CI: 0.05-0.79, high-quality, respectively) of CVAD-associated BSI compared with heparinized saline (reference). Preventative thrombolytic agents had lower odds (OR: 0.64, 95% CI: 0.44-0.93; low-quality) of CVAD occlusion, whereas ethanol had higher odds (OR: 2.84, 95% CI: 1.31-6.16; high-quality) compared with heparinized saline (reference). No lock solution had effects on thrombosis prevention or treatment, CVAD-failure, CVAD-associated BSI treatment failure, or mortality. LIMITATIONS: There was substantial uncertainty around the point estimates because of the limited number of studies for outcomes and study heterogeneity. More high-quality studies are needed to confirm the efficacy of lock solutions. CONCLUSIONS: Chelating agents and antibiotic locks may be effective for CVAD-associated BSI prevention in pediatrics. Thrombolytic agents can be an option for CVAD occlusion prevention, whereas ethanol may not be recommended.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateteres Venosos Centrais , Sepse , Trombose , Criança , Humanos , Antibacterianos , Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Quelantes , Etanol , Fibrinolíticos , Metanálise em Rede , Trombose/etiologia , Trombose/prevenção & controle
13.
BMC Nurs ; 23(1): 4, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38163877

RESUMO

BACKGROUND: Peripherally inserted central catheters (PICCs) are common vascular access devices inserted for adults undergoing intravenous treatment in the community setting. Individuals with a PICC report challenges understanding information and adapting to the device both practically and psychologically at home. There is a lack of research investigating the supportive care needs of individuals with a PICC to inform nursing assessment and the provision of additional supports they may require to successfully adapt to life with a PICC. The aim of this study was to identify the supportive care needs of adults with cancer or infection living with a PICC at home. METHOD: Qualitative, semi-structured interviews were used to identify supportive care needs of adults living with a PICC at home. Participants were recruited from cancer and infectious diseases outpatient units. Two researchers independently analysed transcripts using content analysis. RESULTS: A total of 15 participants were interviewed (30-87 years old). There were 5 males and 10 females interviewed, 9 participants had a cancer diagnosis and most lived in a metropolitan area. Many participants lived with a partner/spouse at home and three participants had young children. Participants identified supportive care needs in the following eight categories (i (i) Adapting daily life (ii) Physical comfort (iii) Self-management (iv) Emotional impact (v) Information content (vi) Understanding information (vii) Healthcare resources and (viii) Social supports. CONCLUSIONS: Adults living with a PICC at home report a broad range of supportive care needs. In addition to practical and information needs, health consumers may also require support to accept living with a device inside their body and to assume responsibility for the PICC. These findings may provide nurses with a greater understanding of individual needs and guide the provision of appropriate supports.

14.
Pediatr Res ; 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38200324

RESUMO

BACKGROUND AND AIMS: Invasive devices are widely used in healthcare settings; however, pediatric patients are especially vulnerable to invasive device-associated harm. This study aimed to explore invasive device utility, prevalence, harm, and clinical practice across three Australian pediatric tertiary hospitals. METHODS: In 2022-2023, a multi-center, observational, rolling-point-prevalence survey was conducted. Fifty-per-cent of inpatients were systemically sampled by random allocation. Patients with devices were then followed for up to 3-days for device-related complications/failures and management/removal characteristics. RESULTS: Of the 285 patients audited, 78.2% had an invasive device (n = 412 devices), with a median of 1 device-per-patient (interquartile range 1-2), with a maximum of 13 devices-per-patient. Over half of devices were vascular access devices (n = 223; 54.1%), followed by gastrointestinal devices (n = 112; 27.2%). The point-prevalence of all device complications on Day 0 was 10.7% (44/412 devices) and period-prevalence throughout the audit period was 27.7% (114/412 devices). The period-prevalence of device failure was 13.4% (55/412 devices). CONCLUSIONS: The study highlighted a high prevalence of invasive devices among hospitalized patients. One-in-ten devices failed during the audit period. These findings underscore the need for vigilant monitoring and improved strategies to minimize complications and enhance the safety of invasive devices in pediatric hospital settings. IMPACT: A high prevalence of invasive devices among hospitalized patients was reported. Of the 285 patients audited, almost 80% had an invasive device (total 412 devices), with a median of 1 device-per-patient and a maximum of 13 devices-per-patient. The most common devices used in pediatric healthcare are vascular access devices (n = 223; 54.1%), however, 16% (n = 36) of these devices failed, and one-third had complications. The point prevalence of all device complications at day 0 was 10.7% (44 out of 412 devices), with a period prevalence of 27.7% (114 out of 412 devices) throughout the audit period.

15.
J Adv Nurs ; 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38263365

RESUMO

AIM: This study aimed to estimate the proportion and rate of skin complications and mechanical dysfunction associated with indwelling invasive devices in paediatric healthcare. DESIGN: This systematic review is reported in accordance with Cochrane standards for randomized controlled trials and the Meta-analysis of Observation Studies in Epidemiology for cohort studies. DATA SOURCES: MEDLINE, CINAHL, Embase, Web of Science, Scopus, Cochrane CENTRAL, clinical trial registries, and unpublished study databases were searched. REVIEW METHODS: Cohort studies and trials published from January 2011 to June 2022, including (1) indwelling invasive devices, (2) paediatric participants admitted to a hospital, (3) reporting post-insertion device-associated skin complication and/or mechanical dysfunction, and (4) published in English, were included. Device-associated skin complication and mechanical dysfunction (infiltration, leakage, occlusion/blockage, dislodgement/malposition, breakage and others). Pooled proportion and incidence rate per 1000 device days are reported. RESULTS: This review synthesized 114 studies (30,782 devices; 1,635,649 device-days). Skin complications were reported in 40 studies, but none exclusively reported individual device-related pressure injuries. Mechanical dysfunctions were well-reported for central venous access devices, peripheral intravenous catheters, nasogastric/gastric tubes and peritoneal dialysis catheters but less for arterial catheters, extracorporeal membrane oxygenation and ventricular assist devices. CONCLUSIONS: This systematic review highlights the need for standardized definitions and reporting methods to better surveil and benchmark device-related complications, particularly for understudied device types. Device-related pressure injuries were not reported in any of the included studies, and all devices except for vascular access devices require standardized reporting of complications. IMPACT: Despite the widespread use of invasive devices, comprehensive data on their prevalence, utility, and associated paediatric complications is limited. This review identified prevalent skin complications, occlusions and dislodgments in children with devices, underscoring the need for standardized reporting to enhance surveillance and understanding of paediatric device-related complications. REPORTING METHOD: MOOSE (Meta-analyses Of Observational Studies in Epidemiology) Checklist. PATIENT OR PUBLIC CONTRIBUTION: No Patient or Public Contribution.

16.
J Hosp Med ; 19(1): 13-23, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38100201

RESUMO

BACKGROUND: Peripherally inserted central catheters (PICCs) and midline catheters are often placed by nurse-led vascular access teams (VATs). While some data regarding the effectiveness of these teams exists, less is known about their structure and function. OBJECTIVES: To examine the roles, functions, and composition of VATs related to the use and management of PICC and midline catheters. METHODS: A descriptive, multi-method study that included an online survey of 62 hospitals participating in a quality improvement consortium and qualitative interviews with 74 hospital-based clinicians in 10 sites. Interviews were recorded, transcribed, and analyzed using a rapid analysis and matrix approach. The survey, which contained closed-ended, categorical questions, was analyzed using frequencies and percentages. RESULTS: More than 77% (n = 48) of hospitals had an on-site VAT. The average team size was seven nurses; their primary function was device insertion. Interview findings revealed that teams varied in characteristics and functions. Interviewees described the broad role that teams play in device insertion, care and removal, and in educating/training hospital staff. However, we found that teams' role in decision making, particularly related to appropriate device selection, was limited and, in some cases, met with physician resistance. CONCLUSIONS: To realize the full benefit of VATs, changes in hospital culture, along with an increased willingness from physicians to integrate VAT nurses in decision making, may be needed. Future interventions aimed at engaging and empowering teams appear necessary.


Assuntos
Cateterismo Venoso Central , Cateterismo Periférico , Humanos , Cateteres de Demora , Cateterismo Periférico/métodos , Recursos Humanos em Hospital , Hospitais de Ensino
17.
Aust Crit Care ; 37(1): 34-42, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38142148

RESUMO

BACKGROUND: Endotracheal suction is used to maintain endotracheal tube patency. There is limited guidance to inform clinical practice for children with respiratory infections. OBJECTIVE: The objective of this study was to determine whether implementation of a paediatric endotracheal suction appropriate use guideline Paediatric AirWay Suction (PAWS) is associated with an increased use of appropriate and decreased use of inappropriate suction interventions. METHODS: A mixed-method, pre-implementation-post-implementation study was conducted between September 2021 and April 2022. Suction episodes in mechanically ventilated children with a respiratory infection were eligible. Using a structured approach, we implemented the PAWS guideline in a single paediatric intensive care unit. Evaluation included clinical (e.g., suction intervention appropriateness), implementation (e.g., acceptability), and cost outcomes (implementation costs). Associations between implementation of the PAWS guideline and appropriateness of endotracheal suction intervention use were investigated using generalised linear models. RESULTS: Data from 439 eligible suctions were included in the analysis. Following PAWS implementation, inappropriate endotracheal tube intervention use reduced from 99% to 58%, an absolute reduction (AR) of 41% (95% confidence interval [CI]: 25%, 56%). Reductions were most notable for open suction systems (AR: 48%; 95% CI: 30%, 65%), 0.9% sodium chloride use (AR: 23%; 95% CI: 8%, 38%) and presuction and postsuction manual bagging (38%; 95% CI: 16%, 60%, and 86%; 95% CI: 73%, 99%), respectively. Clinicians perceived PAWS as acceptable and suitable for use. CONCLUSIONS: Implementation of endotracheal tube suction appropriate use guidelines in a mixed paediatric intensive care unit was associated with a large reduction in inappropriate suction intervention use in paediatric patients with respiratory infections.


Assuntos
Respiração Artificial , Infecções Respiratórias , Criança , Humanos , Sucção/métodos , Intubação Intratraqueal/efeitos adversos , Cloreto de Sódio
18.
Int J Nurs Stud ; 151: 104673, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38142634

RESUMO

BACKGROUND: Peripheral intravenous catheters are the most frequently used invasive device in nursing practice, yet are commonly associated with complications. We performed a systematic review to determine the prevalence of peripheral intravenous catheter infection and all-cause failure. METHODS: The Cochrane Library, PubMed, CINAHL, and EMBASE were searched for observational studies and randomised controlled trials that reported peripheral intravenous catheter related infections or failure. The review was limited to English language and articles published from the year 2000. Pooled estimates were calculated with random-effects models. Meta-analysis of observation studies in epidemiology guidelines and the Cochrane process for randomised controlled trials were used to guide the review. Prospero registration number: CRD42022349956. FINDINGS: Our search retrieved 34,725 studies. Of these, 41 observational studies and 28 randomised controlled trials (478,586 peripheral intravenous catheters) met inclusion criteria. The pooled proportion of catheter-associated bloodstream infections was 0.028 % (95 % confidence interval (CI): 0.009-0.081; 38 studies), or 4.40 catheter-associated bloodstream infections per 100,000 catheter-days (20 studies, 95 % CI: 3.47-5.58). Local infection was reported in 0.150 % of peripheral intravenous catheters (95 % CI: 0.047-0.479, 30 studies) with an incidence rate of 65.1 per 100,000 catheter-days (16 studies; 95 % CI: 49.2-86.2). All cause peripheral intravenous catheter failure before treatment completion occurred in 36.4 % of catheters (95 % CI: 31.7-41.3, 53 studies) with an overall incidence rate of 4.42 per 100 catheter days (78,891 catheter days; 19 studies; 95 % CI: 4.27-4.57). INTERPRETATION: Peripheral intravenous catheter failure is a significant worldwide problem, affecting one in three catheters. Per peripheral intravenous catheter, infection occurrence was low, however, with over two billion catheters used globally each year, the absolute number of infections and associated burden remains high. Substantial and systemwide efforts are needed to address peripheral intravenous catheter infection and failure and the sequelae of treatment disruption, increased health costs and poor patient outcomes.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Periférico , Flebite , Sepse , Humanos , Flebite/etiologia , Infecções Relacionadas a Cateter/epidemiologia , Catéteres , Cateterismo Periférico/efeitos adversos , Sepse/complicações
19.
Hosp Pediatr ; 14(1): e25-e41, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38161187

RESUMO

CONTEXT: The risk of invasive device-related thrombosis and bleeding contributes to morbidity and mortality, yet their prevalence by device-types is poorly understood. OBJECTIVES: This study aimed to estimate pooled proportions and rates of thrombotic and bleeding complications associated with invasive devices in pediatric health care. DATA SOURCES: Medline, CINAHL, Embase, Web of Science, Scopus, Cochrane CENTRAL, clinical trial registries, and unpublished study databases were searched. STUDY SELECTION: Cohort studies and trials published from January 2011 to June 2022, including (1) indwelling invasive devices, (2) pediatric participants admitted to a hospital, (3) reporting thrombotic and bleeding complications, and (4) published in English, were included. DATA EXTRACTION: Meta-analysis of observational studies in epidemiology guidelines for abstracting and assessing data quality and validity were used. MAIN OUTCOMES AND MEASURES: Device-specific pooled thromboses (symptomatic, asymptomatic, unspecified) and bleeding (major, minor). RESULTS: Of the 107 studies, 71 (66%) focused on central venous access devices. Symptomatic venous thromboembolism in central venous access devices was 4% (95% confidence interval [CI], 3-5; incidence rate 0.03 per 1000 device-days, 95% CI, 0.00-0.07), whereas asymptomatic was 10% (95% CI, 7-13; incidence rate 0.25 per 1000 device-days, 95% CI, 0.14-0.36). Both ventricular assist devices (28%; 95% CI, 19-39) and extracorporeal membrane oxygenation (67%; 95% CI, 52-81) were often associated with major bleeding complications. CONCLUSIONS: This comprehensive estimate of the incidence and prevalence of device-related thrombosis and bleeding complications in children can inform clinical decision-making, guide risk assessment, and surveillance.


Assuntos
Trombose , Tromboembolia Venosa , Criança , Humanos , Anticoagulantes , Trombose/epidemiologia , Trombose/etiologia , Hemorragia/epidemiologia , Hemorragia/etiologia , Hemorragia/terapia , Atenção à Saúde
20.
Hosp Pediatr ; 14(1): e42-e56, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38161188

RESUMO

CONTEXT: Indwelling invasive devices inserted into the body for extended are associated with infections. OBJECTIVE: This study aimed to estimate infection proportion and rates associated with invasive devices in pediatric healthcare. DATA SOURCES: Medline, CINAHL, Embase, Web of Science, Scopus, Cochrane CENTRAL, clinical trial registries, and unpublished study databases were searched. STUDY SELECTION: Cohort studies and trials published from January 2011 to June 2022, including (1) indwelling invasive devices, (2) pediatric participants admitted to a hospital, (3) postinsertion infection complications, and (4) published in English, were included. DATA EXTRACTION: Meta-analysis of observational studies in epidemiology guidelines for abstracting and assessing data quality and validity were used. MAIN OUTCOMES AND MEASURES: Device local, organ, and bloodstream infection (BSIs) pooled proportion and incidence rate (IR) per-1000-device-days per device type were reported. RESULTS: A total of 116 studies (61 554 devices and 3 632 364 device-days) were included. The highest number of studies were central venous access devices associated BSI (CVAD-BSI), which had a pooled proportion of 8% (95% confidence interval [CI], 6-11; 50 studies) and IR of 0.96 per-1000-device-days (95% CI, 0.78-1.14). This was followed by ventilator-associated pneumonia in respiratory devices, which was 19% (95% CI, 14-24) and IR of 14.08 per-1000-device-days (95%CI, 10.57-17.58). CONCLUSIONS: Although CVAD-BSI and ventilator associated pneumonia are well-documented, there is a scarcity of reporting on tissue and local organ infections. Standard guidelines and compliance initiatives similar to those dedicated to CVADs should be implemented in other devices in the future.


Assuntos
Cateteres Venosos Centrais , Sepse , Criança , Humanos , Incidência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...